close

Enter

Log in using OpenID

(Low-E #2) + Kuru Hava + Renksiz Float Cam

embedDownload
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
4 (#2) - 12 - 4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
4 - 12 - 4
29 (-1; -4) dB
1,6 W / (m 2K)
NPD
0,79/0,12/0,12
0,51/0,25/0,25
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
4 (#2) - 16 - 4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
4 - 16 - 4
29 (-1; -4) dB
1,3 W / (m 2K)
NPD
0,79/0,12/0,12
0,51/0,25/0,25
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 12 - 4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 12 - 4
32 (-2; -4) dB
1,6 W / (m 2K)
NPD
0,78/0,12/0,11
0,50/0,23/0,25
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 16 - 4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 16 - 4
32 (-2; -4) dB
1,3 W / (m 2K)
NPD
0,78/0,12/0,11
0,50/0,23/0,25
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 12 - 5, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 12 - 5
32 (-2; -4) dB
1,6 W / (m 2K)
NPD
0,77/0,12/0,11
0,49/0,23/0,23
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 16 - 5, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 16 - 5
32 (-2; -4) dB
1,3 W / (m 2K)
NPD
0,77/0,12/0,11
0,49/0,23/0,23
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 12 - 6, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 12 - 6
31 (-1; -4) dB
1,6 W / (m 2K)
NPD
0,77/0,12/0,11
0,48/0,23/0,22
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (#2) - 16 - 6, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
NPD
NPD
NPD
NPD
NPD
NPD
NPD
Resistance against sudden temperature changes
and temperature differentials
NPD
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
6 - 16 - 6
31 (-1; -4) dB
1,3 W / (m 2K)
NPD
0,77/0,12/0,11
0,48/0,23/0,22
Author
Document
Category
Uncategorized
Views
0
File Size
1 059 KB
Tags
1/--pages
Report inappropriate content