SensaLite First step to comfort and energy saving with intelligent luminaires Introduction Thorn’s Indoor Lighting Controls portfolio is grouped into three distinct usage types 3 2 1 1 SensaLite features Thorn luminaires with built-in sensors, and remote sensors, offering standard presence detection, daylight linking and infra-red control. SensaLite is the first step to comfort and energy saving, and is used for small office applications, simple classrooms, corridors etc. • The simplest products are switching presence detectors and photocells, called SwitchLite • RotaryDIM offers precise manual control via a wall plate • SensaDigital covers both features: Daylight-linked dimming, presence detection and manual override via an infra-red hand held controller 2 2 ControLiteDIM is used for mid-sized projects (1 room): The portfolio consists of modules for creating scene setting, enabling daylight linking and integrating presence detection. It is easy to commission by the contractor. When wiring the system, the luminaires are allocated to the switches, scene plates and presence detectors. 3 SensaLink features Thorn luminaires with built-in sensors and remote sensors offering presence detection, daylight linking and infra red control, scene setting and the possibility to link sensors. It provides a linked lighting management system for larger-sized projects and those requiring greater levels of comfort. SensaLite Performance, Efficiency, Comfort How does SensaLite support the Thorn PEC strategy? Performance: SensaLite enables you to set the right light level at the right place and at the right time. Efficiency: SensaLite is the perfect tool to provide an efficient light. Depending on the chosen product, it enables you to dim the luminaires, link the luminaires to your presence and link them to the incoming daylight to achieve energy saving. Therefore light is only provided when you need it and in the quantity that you require. One of the SensaLite products, SensaDigital, provides an additional feature: it continually adjusts its light output and energy input. This maintains illuminance over the entire period, saving the energy that conventional systems waste and fulfilling the objectives of many international and local lighting standards. Comfort: Manual dimming and presence detection are features of SensaLite making your light very comfortable. Additionally SensaLite is very easy to install and to set up. With maintaining the illuminance level over the entire period using SensaDigital (part of the SensaLite portfolio), you will always have the same light level that you require. SwitchLite SensaLite portfolio SensaDigital RotaryDIM Where to use SensaLite? Typical applications include: • Small offices, simple classrooms and other applications looking for energy saving with presence and daylight-linked luminaires or luminaire groups, • Infrequently entered areas requiring presence-linked switching of luminaires, e.g. corridors, staircases and storerooms, • Or small applications requiring intuitive and precise manual dimming of luminaires, e.g. in restaurants and bars. Examples are: Application ➦ Function Presence detection Daylight-link Dimming and Switching School & Education (class rooms) Single Offices • • • • • • Board & Seminar rooms Sport & Leisure Retail • • • Health Industry • • • • • • • • Corridors, staircases, toilets, store rooms • 3 Overview and portfolio selection guide SensaLite offers numerous beneficial functions. The three product ranges provide a variety of features – so you can easily decide what’s best for your application: RotaryDIM SwitchLite SensaDigital Response to presence/absence • • Switching response to incoming daylight • Functions Dimming response to incoming daylight Precise dimming • • Maintained illuminance level • Local override IR handheld controller • Momentary action switch • Parameter setting for tailor-made functionality Manually • IR programmer • Installation integrated in luminaire • ceiling mounted wall mounted • • corner mounted 4 • • • Response to presence/ absence Switching response to incoming daylight A presence-linked sensor responds to occupancy, and will switch the lighting On and Off when you enter or leave the room. The sensor incorporates an adjustable ON time delay after the last detected movement. It then switches Off the lighting. SwitchLite SensaDigital Dedicated photocells switch the luminaires On or Off in response to changes in the ambient light level. You can use these products as the daylight dependent On/ Off switch for the luminaires or in conjunction with a wall switch. These products come with an adjustable light level. SwitchLite Some sensors offer you a socalled semi-automatic mode (absence detection), where you will switch On the lighting manually (via a switch or handheld controller), and the detector will automatically switch Off the lighting after the room has been vacated. SensaDigital Dimming response to incoming daylight Sensors with dimming facility automatically adjust the light level in response to the daylight. You decide which light level the controlling sensor should maintain through the day, and if the sensor should switch the lighting Off if there is enough daylight. SensaDigital Precise dimming Local override Accurate dimming even over very long lead distances can be achieved by using digital dimming commands, i.e. controlling electronic ballasts with digital interfaces like DSI (“Digital Serial Interface”). • Some systems offer you an infra-red handheld controller to override sensors that are responding to the incoming daylight – especially convenient in larger office applications, where you want to change the lighting allocated to your desk only. A digital rotary dimmer, with DSI output, can be used as a control device. RotaryDIM • Alternatively you can use a momentary action switch for changing the light level and to switch the light On and Off. The switch is mounted onto the wall next to the entrance of the room, and therefore ideal for smaller and single offices SensaDigital RotaryDIM SwitchLite SensaDigital • Sensors incorporating switching photocells allow you to set the light level that must be reached before the controlling device switches the light Off or keeps it Off. • Sensors responding to presence/ absence enable you to set the time duration that the device switches Off the luminaires after detecting the last movement. You are able to configure these settings manually at the product. SwitchLite Other portfolios use an infra-red programming tool to re-programme a wide range of parameters, and to set the regulating light level. This is particularly useful as you are able to change the parameters without touching the installation. It is therefore fast, hassle-free and Maintenance non-disruptive to the room users: The programming is done remotely and hence can be operated from the ground. Light level, time delay to switch Off, start-up level, fading, operation mode etc. can be set. SensaDigital Required normal illumuminance Energy savings through dimming of surplus capacity Maintained illuminance level Light levels reduce over time due to lamp age and dirty optics. Conventional installations provide more light than is necessary to ensure that the right level is met as depreciation occurs. This results in energy wastage and unnecessary cost. Being intelligent, some SensaLite products continually adjust their light output and energy input. This maintains illuminance over the entire period, saving the energy that conventional systems waste and fulfilling the objectives of many international and local lighting standards. SensaDigital Illuminance in accordance with age and soiling of lamp Illuminance Parameter setting for tailor-made functionality The default settings supplied are appropriate for most applications, however you have the facility to adapt SensaLite to your needs: Maintenance interval maximum length of the DSI wire between sensor heads and luminaires can be 12m, and between digital rotary dimmers and luminaires 50m, using standard mains wiring 2 x 1.5mm² with solid or stranded conductors, e.g. H05VV-U (harmonised standard 300/500V cable, PVC insulated and sheathed, with solid conductors) SensaDigital RotaryDIM Easy installation The SensaLite products are easy to install: • Products switching mains are connected to the luminaires with standard mains wiring. SwitchLite • For the connection of dimming products, incorporating a DSI output, to the DSI dimmable luminaires, you use a 2-pole polarity-free DSI wire. The SensaLite – how to find the right product: Dimming? yes no day light linked? day light linked on/off? no yes no yes presence-linked? yes SensaDigital presence-linked? no RotaryDIM yes SwitchLite PIR presence-linked? no SwitchLite Photocells yes SwitchLite PIR+MW no no controls 5 RotaryDIM: benefits and application Some applications merely require the ability to dim luminaires manually, e.g. bars, restaurants, hotel lobbies and waiting rooms in hospital areas. Thorn’s unique Digital Rotary Dimmer enables you to change the light level of a luminaire group incorporating up to 20 DSI ballasts – by simply turning the knob. This way of dimming is highly intuitive – as you change the light level in the way you are used to do it, at home or in lecture rooms. Note: All standard Thorn DSI dimmable luminaires can be controlled via RotaryDIM: look for Thorn luminaires containing �HFD’ in the descriptions of the relevant luminaire ordering guides. Precise Dimming Providing a DSI output, RotaryDIM ensures accurate dimming even over long wiring distances due to the use of digital dimming commands. All luminaires (incorporating up to 20 DSI ballasts) will be precisely on the same light level. DSI L N Wiring 6 RotaryDIM SwitchLite SensaDigital Easy installation You just connect the Thorn standard DSI dimmable luminaires (incorporating up to 20 DSI ballasts) to the DSI output of RotaryDIM. The DSI connection is polarity-free. Additionally you connect both the luminaires and the dimmer to the mains and it works! RotaryDIM application example A bar featuring three suspended pendant luminaires over the tables, and five over the bar, e.g. with compact fluorescent lamps and DSI ballast. Requirement: Bar and guest area should be manually dimmable (separately from each other). Solution: two RotaryDIM units are used. DSI DSI Mains RotaryDIM luminaires } DSI control wires up to 50m, using standard mains wiring 2 x 1.5mm² with solid or stranded conductors, e.g. H05VV-U*, polarity free standard mains wiring * harmonised standard 300/500V cable, PVC insulated and sheathed, with solid conductors 7 SwitchLite: benefits and application If you do not need to dim luminaires, due to their applications, but you still want to save energy by linking the lighting to presence and/or daylight, you use SwitchLite. This provides a level of simple automation when only a switching mains supply is provided to the luminaires: • SwitchLite Presence Detectors detect movement and switch luminaires On or Off in response to occupancy. Some of them also include a built-in photocell to respond to light levels if required. The SwitchLite portfolio includes Passive infrared (PIR) detectors as well as Microwave detectors. Different mounting options and detection ranges adapt to the needs of different applications, like simple offices, corridors, stair cases, utility rooms, toilets and store rooms. • SwitchLite Photocells switch the luminaires On or Off in response to changes in the ambient light level. You can use them as the daylight dependent On/Off switches for your luminaires or in conjunction with a wall switch. These photocells are ideal for controlling luminaires next to windows and in general for applications with higher daylight levels, e.g. atriums, shop windows, or in installations where due to safety reasons the lighting has to be switched on as soon as it is beginning to get dark, e.g. in public buildings, staircases and corridors. Ceiling mounted PIR Presence Detector with built-in photocell The SwitchLite MRE SLD recessed PIR Presence Detector provides energy saving by switching On/Off in response to room occupancy and daylight levels. It controls standard luminaires employing either wound gear or high frequency fixed output ballasts. The detector can be converted to a surface mounted version by using the mounting attachment kit SwitchLite KIT MSF accessory. The detector covers up to 7 metres diameter at a 2.8m mounting height. • The minimum ambient light level can be adjusted to ensure luminaires are switched On when you enter the room and daylight is insufficient, or when you are present and the daylight is getting insufficient, but also to ensure luminaires remain switched Off when you enter and there is enough daylight. No-one present. Lights off. You enter the room. Insufficient daylight. Lights switch on. You are present. Insufficient daylight. Lights on. You remain present. Sufficient daylight. Lights stay on. No-one present. Insufficient daylight. Lights off. No-one present. Sufficient daylight. Lights off. • Additionally you can also bring the minimum ambient light level to a point at which daylight has no effect: in effect allowing the product to work as a presence detector only. • Furthermore the product provides a highly flexible time delay (adjustable between 10s and 30min), before switching luminaires Off after you have left the room. Recessed and surface mounted SwitchLite PIR presence detector. L /OUT L N 2.8m 5 - 7m L Wiring 8 N Detection pattern RotaryDIM SwitchLite SensaDigital Wall/corner mounted PIR Presence Detector with built-in photocell For application such as corridors, staircases, storerooms or washrooms you use the SwitchLite SLD LONG RANGE wall mounted PIR presence detector: This is a wall/corner mounted unit with 110° coverage and up to 12 metre detection range. When occupancy is detected lights are switched On, and they are switched Off after a time delay has elapsed when no-one is present. You can adjust the time delay between 4 and 32 minutes to suit the type of activity being carried out. This detector offers you a built-in photocell that can be used to keep lights Off or to switch them Off whenever sufficient daylight is present - you can disable this feature if not required. Wall mounted Microwave Presence Detector No-one present. Lights off. You approach the staircase. Lights switch on. The SwitchLite SLDM is part of the SwitchLite range and is intended for general use, e.g. for corridors, warehouse racking and halls. The sensor detects movement using a highly sensitive microwave detector. This works by emitting low power microwave signals and measuring the reflections as the signals bounce off moving objects. The product is optimised for wall mounting applications to give detection over long distances (up to 30m), and in areas without thin walls or partitions (e.g. with glass). When a movement is detected the load is turned On. When an area is no longer occupied the load will switch Off after a time out period that you can adjust between 15s and 30min. The unit also has an integral sensitivity adjustment, enabling you to change the detection range from 30m down to 1m. The detector has no external lenses giving the unit additionally the appearance of a standard accessory blank plate, which is very useful in public applications like schools etc. Sufficient daylight. Lights switch off or remain switched off. No-one present. Lights off. You enter the corridor. Lights switch on. Wall mounted Microwave presence detector. 30m Wall/corner mounted long range PIR presence detector N 12m L' L N Com N/O L N L' L' L L 6m N Wiring Detection pattern Wiring Detection pattern 9 Photocells SwitchLite Photocells, which can be recessed or surface mounted, switch the luminaires On or Off in response to changes in the ambient light level. You can use these products as the daylight dependent On/Off switch for the luminaires or in series with a wall switch. Suitable for classrooms, public buildings, lobbies, reception areas etc., with an adjustable light level from 50 up to 1500lx. Sufficient daylight. Photocells controlling the luminaires nearest the window turn light off. Insufficient daylight. Lights on. L N L' L' L Wiring 10 Recessed and surface mounted SwitchLite PIR presence detector Wiring N RotaryDIM SwitchLite SensaDigital SwitchLite application example A doctor’s practice comprising reception area, waiting room, surgery and attached corridor: • The reception area is switched according to the daylight level using a photocell in series with a standard mains switch. Once the ambient light level is below 300lx the light is switched Off. • For the waiting room a corner mounted PIR presence detector is used to detect everybody entering the room and to switch the light On when required. The detector switches the light Off or keeps it switched Off as soon as the minimum ambient light level reaches the set 300lx. It also switches the luminaires automatically Off 8min after the last patient has left the room. • The light in the surgery responds to presence – two ceiling mounted PIR presence detectors are employed. The minimum ambient light levels are set to 500lx. If somebody enters the room and daylight is sufficient, the light remains switched Off. If the daylight is insufficient they will switch the luminaires On and will keep them switched On even if daylight gets sufficient. They also switch the luminaires Off automatically 15min after the last person has left the room. SwitchLite Photocell Mains SwitchLite PIR Presence detectors SwitchLite Long Range PIR Presence detector SwitchLite Micrwave Presence detector Mains Switch Corridor Reception Waiting Room Surgery Luminaires Mains switch SwitchLite PIR SwitchLite Photocell SwitchLite Long Range PIR SwitchLite Microwave Standard mains wiring • The corridor being 20m long, with no windows, thin or glass walls is, therefore, an ideal application for a Microwave presence detector. It switches the corridor lighting On as soon somebody enters (either through the building or via the practice) and switches Off 5min after the last detection. 11 SensaDigital: benefits and application SensaDigital responds to presence/absence by switching, and to daylight by dimming: Entering an area causes the lighting to come to a preprogrammed level. The luminaires automatically adjust depending on the natural light present. Thorn was among the first companies to offer intelligent luminaires: MenloSoft SR with built-in MiniSensaDigital head • The so called SensaDigital Luminaires incorporate a miniature sensor capable of controlling electronic gears, transformers and phase dimmers via a DSI signal. • The benefit of a SensaDigital Luminaire lies in the fact that it works as soon as you take it out of the box and install it to the ceiling. You can still switch the luminaire Off via a standard mains switch, which also means you do not have to change an existing installation. • �Mother-daughter’ or �master-slave’ arrangements are possible as well, where you connect further luminaires (�daughters’) to the DSI output of the SensaDigital Luminaire (�mother’). The maximum number of ballasts incorporated in all controlled luminaires must not exceed 4, and all luminaires should be in the detection zone of the MiniSensaDigital head (diameter 5m at nominal mounting height 2m). HFS HFD HFD HFD Remote SensaDigital sensor heads enable you to control a group of luminaires: instead of having a �mother-daughter’ arrangement as described above, these remote sensor heads are mounted to the ceiling and control a luminaire group incorporating up to 8 DSI ballasts each. These luminaires should be in the detection zone of the sensor head (diameter 6m at nominal mounting height 2.4m). You have the choice between recessed mounted versions that are suitable for unobtrusive installation in suspended ceilings, or surface mounted versions for all other types of ceilings. Recessed SensaDigital head Note: All standard Thorn DSI dimmable luminaires can be controlled via remote SensaDigital heads: look for Thorn luminaires containing “HFD” in the Ordering Guide descriptions. Optional �Mother-daughter’ luminaire arrangement (max. 4 ballasts in total) Surface mounted remote SensaDigital head HFD HFD HFD HFD 2m 5m Sensor connected to luminaire group (max. 8 ballasts in total) Detection pattern 2.5m Note: See relevant luminaire Ordering Guides for Thorn SensaDigital luminaires (containing �HFS’ in their descriptions). �Daughter’ luminaires for connection to the SensaDigital Luminaires, are the standard DSI dimmable ones (containing �HFD’ in their descriptions). 6m Detection pattern N L D1 nc T DSI L D2 N S SwitchDIM DSI D1 D2 Wiring recessed version 12 Wiring surface mounted version RotaryDIM SwitchLite SensaDigital Switching response to presence/absence You have the choice between two operation modes automatic and semi-automatic: Set to the automatic mode, the sensor will detect you entering and leaving the room, and will switch On and Off the lighting accordingly. If you choose the semi-automatic mode, you will switch On the lighting manually (via a switch or the SensaDigital handheld controller), and the detector will switch the lighting Off automatically after you have left the room. The sensor’s Off time delay after the last detected movement can be configured (between 5 and 60min). Instead of switching Off the lighting abruptly, SensaDigital also enables the lighting to be smoothly faded out. No-one present. Lights off. You enter the room. Lights switch on. You are present. Insufficient daylight. Lights on. You remain present. Sufficient daylight. Lights dim. Dimming response to incoming daylight SensaDigital automatically adjusts the light level in response to the daylight. You decide which light level SensaDigital should maintain through the day, and if the sensor should switch the lighting Off if there is enough daylight. You remain present. Bright daylight. Lights dimmed to minimum. 13 Local override • Just use the SensaDigital infra-red handheld controller SENSA SENRC to override SensaDigital – very convenient especially in office applications, where you can change the lighting allocated to your desk only. • If you use the recessed mounted version of the remote SensaDigital head you have the additional possibility to override SensaDigital, using a standard momentary action switch (mounted next to the room entry). Its functions are On/Off (short press alternating) and brighter/dimmer (long press alternating). How it works: + (short press) = On + (long press) = brighter − (short press) = Off − (long press) = dimmer Parameter setting for tailormade functionality The default settings supplied are appropriate for most applications, however you have the facility to re-programme a wide range of parameters, and to set the regulating light level, using the SensaDigital infra-red programming tool SENSA SENP. A particularly useful feature is that you are able to change the parameters without touching the installation. It is, therefore fast, hassle-free and non-disruptive to room users: The programming is carried out remotely and hence can be operated from the ground. Light level, time delay to switch Off, start-up level, fading, operation mode (auto or semiauto) etc. can be set. 14 RotaryDIM SwitchLite SensaDigital Maintained illuminance level Maintenance Required normal illumuminance Energy savings through dimming of surplus capacity Solicitor’s practice comprising the solicitor’s single office and the partners’ group office: • The lighting in both offices is presence-linked and dimmed according to the incoming daylight. The specified illuminance level is 500lx and has to be maintained. Furthermore the lighting is faded to Off 10min after the last detection. Illuminance SensaDigital maintains illuminance over the entire period, saving the energy that conventional systems waste by providing more light than necessary to ensure the right light level until the lamps are changed and the luminaire is cleaned. Therefore SensaDigital is the right tool to fulfill the objectives of many international and local lighting standards regarding light level and energy consumption. SensaDigital application example Illuminance in accordance with age and soiling of lamp Maintenance interval The group office uses two remote SensaDigital heads each controlling two recessed fittings each. The heads are operated in semi-automatic mode, that means the light has to be switched On manually (a manual override is provided by two momentary action switches), but is switched Off after detecting absence. • The single office uses two suspended luminaires in a �mother-daughter’ arrangement, one incorporating a MiniSensaDigital head, the other connected to it via DSI. Additionally an infra-red handheld controller enables manual override. Mains DSI DSI DSI Partners’ group office Solicitor's single office SensaDigital remote heads (recessed mounted version) Infra-red handheld controller Luminaire with integrated MiniSensaDigital head Momentary action swithches conntected to remote head DSI control wires up to 50m, using standard mains wiring 2x 1.5mm² with solid or stranded conductors, e.g. H05VV-U*, polarity free * harmonised standard 300/500V cable, PVC insulated and sheathed, with solid conductors Standard mains wiring Luminaire 15 Product details and Ordering guides ROTARYDIM RDMR 96218669 RotaryDIM Rotary digital dimmer to control the light level of all luminaires connected to its DSI output: brighter or dimmer. Digitally enabled luminaires (incorporating up to 20 DSI ballasts in total) can be controlled by simply and ergonomically turning the knob. 1 Gang plate, white. To be mounted into UK standard back box (not supplied) for sinking in (min. box depth 30mm) or dry-line plaster board walls. Input voltage 230V, 50Hz, 1 DSI output, terminals 2x 2.5mm². Degree of protection IP20, permitted ambient temperature 0...+30°C. SWITCHLITE MRE SLD 96218677 Recessed PIR Presence Detector providing energy saving (on/off switching) in response to room occupancy and daylight levels, controlling standard luminaires containing wound gear or high frequency ballasts. Suitable for indoor use only. To switch from more than one position two or more units are wired in parallel. Covers up to 7 metres diameter at a 2.8m mounting height. Minimum ambient light level and time delay before switching luminaires off (10s to 30min) adjustable. Fits into 64mm diameter hole in suspended ceilings. Supply voltage 230...240V, 50Hz. Switching capacity 8A resistive, 6A capacitive or inductive, 8 HF electronic ballasts, or 3A with compact fluorescent lamps. SWITCHLITE KIT MSF 96218678 To be used with SWITCHLITE MRE SLD recessed PIR presence detector (96 218 677) for surface mounting applications. Fixing centres either 50 or 60mm. Sensor head pushed into kit and secured wih screw. Dimensions 76mm diameter, height 65mm. SWITCHLITE SLD LONG RANGE 96012710 Compact self-contained PIR passive infra-red movement detector with built-in photo-cell and switching relay. Wall/corner mounted unit with 110° coverage and up to 12m detection range, mounting height 2.2m. Supplied with an integral mounting bracket. Time delay adjustable (4, 8, 16 or 32min). Built in photo-cell adjustable (50...1500lx or off). Supply voltage 220...240V, 50Hz. Switching capacity standard 8A inductive or resistive, or 8HF electronic ballasts. 16 SwitchLite SWITCHLITE MRE SLDD 96006665 SwitchLite Ceiling mounted, self-contained recessed photo-cell unit switching lighting OFF when sufficient daylight is present. Can be used as ON/OFF daylight dependant switch or in series with wall switch. Adjustment controls for photo-cell (50 to 1500lx +-10% or off) and time delays (at least 30s to respond to light level change, or 5s in test mode) located behind the removable front cover lens. Fully recessed unit. Supplied with 2 metre flying lead for connection, requiring 42…45mm diameter mounting hole, minimum void depth 150mm. Supply voltage 230...249V, 50Hz. Switching capacity Standard 8A inductive or resistive or 8HF electronic ballasts. Permitted ambient temperature -10...+35°C. Protection type IP20. Protection class SC2. SWITCHLITE MSF SLDD 96006666 Ceiling mounted, self-contained surface photo-cell unit switching lighting OFF when sufficient daylight is present. Can be used as ON/OFF daylight dependant switch or in series with wall switch. Adjustment controls for photocell (50 to 1500lx +-10% or off) and time delays (at least 30s to respond to light level change, or 5s in test mode) located behind the removable front cover lens. Surface mounted version. Terminal block (2.5mm²) for mains connection and switched live, distance between two drilling holes for mounting 60mm. Supply voltage 230...249V, 50Hz. Switching capacity Standard 8A inductive or resistive or 8HF electronic ballasts. Permitted ambient temperature -10...+35°C. Protection type IP20. Protection class SC2. SWITCHLITE SLDM 96019208 Sensor detecting movement using a highly sensitive microwave detector, optimised for wall mounting applications to give detection over long distances (up to 30m, diameter 6m), with integral sensitivity adjustment (1…30m). Adjustable time out period (15s…30min). No external lenses. To switch from more than one position two or more units are wired in parallel. Recommended mounting height 1.2…1.5m. Microwave radiation lower than 6% of the ANSI IEEE C95.1-1991 recommendation. On maximum sensitivity this unit is extremely sensitive to movement and may detect through thin walls or partitions (e.g. glass). Flush mounted into UK standard steel back box (depth 25mm) or cavity wall box (depth 32mm), or surface mounted into plastic surface mount box (depth 25mm). Supply voltage 230...249V, 50Hz. Switching capacity 10A resistive, 8A resistive or inductive, 5A capacitive or inductive, 8 HF electronic ballasts, or 3A with compact fluorescent lamps. 17 SENSA MRE SEND DSI 96211279 Recessed PIR detector and photocell, responds to presence/absence and to light by dimming or switching off, can control luminaires incorporating up to 8 DSI ballasts. Supplied with a 2m flying lead. Can be used in conjunction with an On/Off switch. Additional input for momentary action switch for manual override (dim/brighten, switch On/Off). Suitable for flush fitting to a suspended ceiling (max. height 3m, max. thickness 54mm, hole diameter 50mm, ceiling void 125mm). Detection zone radius 6m at 2.4m ceiling height. Sensor line 2-wire digital polarity-free, max. length 12m. Photocell: adjusted when commissioned. Degree of protection IP40. Dimensions � 65mm, height 115mm. SENSA MSF SEND DSI 96013491 Surface PIR detector and photocell, responds to presence/absence and to light by dimming or switching off, can control luminaires incorporating up to 8 DSI ballasts. Can be used in conjunction with an On/Off switch. The housing may be secured to a hard surface or a UK standard BESA box. The unit fits into the housing with a simple bayonet action. Detection zone radius 6m at 2.4m ceiling height. Sensor line 2-wire digital polarityfree, max. length 12m. Photocell: adjusted when commissioned. Degree of protection IP43. Dimensions � 100mm, height 72mm. Luminaires with built-in MiniSensaDigital head To see which standard THORN luminaires are SensaDigital ones, look for “HFS” in the descriptions of the relevant luminaire Ordering Guides. SENSA SENRC 96004175 Hand held Infra-red controller provides the user with local override facility, allows to select preferred light levels for particular tasks, and to switch the light on and off. Two button controller with On/raise and Off/lower function, key assignment: – Short press to turn off, long press to dim, + Short press to turn on, long press to brighten. Supply voltage 1.8-3.6V (2 type AAA batteries), range 2.5m. Dimensions 120 x 56 x 22 mm. Weight 24g. 18 SensaDigital SENSA SENP 96004189 SensaDigital Infra-red programming tool, used to set up SensaDigital heads. Programming is done remotely and therefore can be operated from the ground. Light Level, time delay to switch off, start-up level, fading, operation mode (auto or semi-auto) etc. can be set. 12 �dip’ switches select the required options. The large white button is pressed to programme the head to the new requirements. Three red buttons set the light level up, down and store. A green LED indicates transmission (when depressing �store’ or �press to programme’). Power supply 2 LiMn 3V batteries type CR2032 (included). Dimensions 78 x 56 x 19 mm. Weight 50g. Ordering Guide Description SAP code Rotary Digital DSI Dimmer ROTARYDIM RDMR 96218669 Description SAP code SwitchLite Presence Detectors SWITCHLITE MRE SLD SWITCHLITE KIT MSF 96218677 96218678 SwitchLite Long Range PIR Presence Detector SWITCHLITE SLD LONG RANGE 96012710 SwitchLite Microwave Presence Detector SWITCHLITE SLDM 96019208 SwitchLite Photocells SWITCHLITE MRE SLDD SWITCHLITE MSF SLDD 96006665 96006666 Description SAP code SensaDigital Remote Heads SENSA MRE SEND DSI SENSA MSF SEND DSI 96211279 96013491 SensaDigital Programming Tool SENSA SENP 96004189 SensaDigital Hand Held Controller SENSA SENRC 96004175 19 Lighting people and places Thorn Lighting Limited UK Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE UK Sales desk Orders/Stock Enquiries Tel: 08701 610 610 Fax: 08701 610 611 Project Enquiries: Tel: 08701 610 710 Fax: 08701 610 711 Ireland 320 Harold’s Cross Road, Dublin 6W Tel: (353) 1 4922 877 Fax: (353) 1 4922 724 E-mail: [email protected] Outdoor Lighting Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE Tel: 020 8732 9829 Fax: 020 8732 9825 E-mail: [email protected] Spare Parts Tel: 0191 301 3131 Fax: 0191 301 3038 E-mail: [email protected] International Sales Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE Tel: 020 8732 1915 Fax: 020 8732 1911 E-mail: [email protected] Thorn Lighting Ltd Dubai Al Shoala Building, Office 301, Block E, PO Box 1200, Deira, Dubai, UAE Tel: (971) 4 2940181 Fax: (971) 4 2948838 E-mail: [email protected] Thorn Gulf LLC Al Shoala Building, Office 301/2, Block E, PO Box 1200, Deira, Dubai, UAE Tel: (971) 4 2948938 Fax: (971) 4 2948838 E-mail: [email protected] Other Offices in: Australia, Austria, China, Czech Republic, Denmark, France, Hong Kong, Italy, New Zealand, Norway, Poland, Russia, Singapore, Sweden and UAE www.thornlighting.co.uk Technical Support Tel: 0870 600 8111 Fax: 0191 301 3907 E-mail: [email protected] Brochureline Answering Service Brochures on specific products/ranges Tel: 020 8732 9898 Fax: 020 8732 9899 E-mail: [email protected] Thorn Lighting is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. The right is reserved to change specifications without prior notification or public announcement. All goods supplied by the company are supplied subject to the company’s General Conditions of Sale, a copy of which is available on request. All measurements are in millimetres and weights in kilograms unless otherwise stated. Publication No: 399(GB) Publication Date: 03/07 Member of The Lighting Industry Federation ISO 9001:2000 Reg: 2916/0 Manufacturing & Distribution
© Copyright 2024 Paperzz