TOP900-TLX
Wireless Outdoor Lighting Controller
(136.41 Connector Compliant)
The Lumewave TOP900 TLX wireless smart lighting
controller brings a new level of savings and control to
outdoor lighting.
The module mounts to the new ANSI 136.41 twist-lock photocell connector installed
by the fixture manufacturer or during fixture retrofit, and allows up to 4 low voltage
control wires to pass through into the fixture housing for connection to the lamp
driver and motion sensor .
The versitile Top900 can operate with LED and eHID ballasts, plasma and
induction light sources. The Top900 also provides feedback to users regarding the
condition of lamps, ballasts, energy usage, power quality, and the exact location of
the fixture.
Fixtures can be addressed and grouped for unified on/off, high-low stepped
dimming with off, tri-level stepped dimming with off, or 0-10 volt linear dimming
operation. The TOP900 provides adjustable photocell thresholds as well as a time
of day and astronomical clock with up to 9 time-of-day actions for additional
savings.
The LumeStar front-end software makes it simple to group fixtures and set
operational parameters. In addition, valuable indicators report the health and
status of the fixture, including any failures, energy consumption, and power quality,
These indicators are relayed back based on a schedule by the user. This saves the
time and cost of work crews driving from location to location looking for outages
and day burners, and increases safety by reducing the risk of a burned out light not
being reported. Work orders are automatically generated for the customer.
The Lumewave Controllers automatically selects network and channels to insure
interference-free oper-ation. Gateways are highly reliable with a range of 5 miles
(base station, antenna dependent) and networks may have an unlimited number of
devices on them. A minimum of one gateway is required per site.
3 Gateway Interfaces are available:
1. USB
2. Ethernet
3. Cellular
www.echelon.com
Control HID, LED, LEP and
Induction lamps
• Control Profiles and interfaces
• Power to fixture on/off
• Bi-level with OFF
• 0 -10V (sink) dimming control with
0V turning fixture power Off
• Dimming control in .1V increments
• Control Events & Schedules
• Weekday & weekend schedules
• Special event schedule
• Schedule up to 9 control events/
day
• Scheduled events based on time of
day and/or astronomical time
• Schedule use of motion sensors and
photocell
Electrical Specifications
Wireless Specifications
•C
onnects to new ANSI 136.41
connector
• Wireless Standard: IEEE 802.15.4
• 345J Surge Protection
• Channels: 10
•C
ustom Zero Crossing circuit to
protect relay contacts from sudden
in-rush currents
•N
o need to penetrate fixture to pull
wires
•O
perating Voltage: 120 –277Vac
50/60Hz
•O
perating Temperature: -40C to
+70C
• Fixture Power Contact: 1000W, 10A
• Dimming: 0-10V (Sink)
•Failsafe: Power ON, Lamp High,
0-10V = 100%
• Operating Frequency: 902—928Mhz
•RF power: Adjustable to +24dbm
(250mw)
• Antenna: Internal/external 1/4 wave
monopole
• Range: Gateway Base to TOP900 = 2
miles (LOS)
• Range: TOP 900 to TOP900 @ 25’
AGL (LOS) 1 mile
• Range Extender: TOP 900 can be
used as a repeater
• Encryption AES 128bit
Low Voltage Control Wiring
• Motion detector input
1. Violet + 0-10V (Sink)
• Real-time commands and overrides
• Photocell daytime override
2. Gray - 0-10V (Ground)
* Power Metering (Revenue Grade)
3. Orange +12V DC for Motion Sensor
• Data Logging
•T
ilt sensor for knock-down alert
(Optional)
• Failure detection and reporting
• Real-time Clock w/battery backup
• Photocell thresholds synchronization
•P
rogrammable Time of day and/or
Astronomical time control events
and schedules
• Motion detector input
• Emergency call button input
• Over the air flashing (program
updates)
• 0-10V Dimming
• Distributed
process - Event
schedules executed at unit. No need
for gateway to be on line
•R
eal-time overrides of all control
functions
•R
eal-time (demand incident)
overrides of all schedules
4. Brown Motion Detector Input
Line Voltage Wiring
• Line L1 (Black)
• Common L2 (White)
• Switched Power (Red)
** Requires fixture to be supplied with
ANSI 136.41 twistlock connector with
either 2 or 4 low voltage control wires
© 2014 Echelon, LonWorks, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other
countries.IzoT is a trademark of Echelon Corporation. Content subject to change without notice.