SABATO 28 MARZO 2015 ore 8,30-12,00

FRM093E000.OTT
Manuale connessioni Weintek verso PLC
Elsist
ELSIST S.r.l.
Sistemi in elettronica
Via G. Brodolini, 15 (Z.I.)
15033 CASALE M.TO
ITALY
Internet: http://www.elsist.it
Email: [email protected]
TEL. (39)-0142-451987
FAX (39)-0142-451988
INDICE
1ELSIST MODBUS RTU/ASCII............................................................................................................................... 2
1.1HMI Setting:..................................................................................................................................................... 2
1.2PLC Setting...................................................................................................................................................... 2
1.3Device address................................................................................................................................................ 2
1.4Wiring Diagrams.............................................................................................................................................. 2
2ELSIST TCP/IP...................................................................................................................................................... 6
2.1HMI Setting:..................................................................................................................................................... 6
2.2PLC Setting...................................................................................................................................................... 6
2.3Device address................................................................................................................................................ 6
2.4Wiring Diagrams.............................................................................................................................................. 6
MNL178B100
Pag. 1/6
Manuale connessioni Weintek verso PLC Elsist
1
ELSIST MODBUS RTU/ASCII
Supported devices: SlimLine & Netsyst controllers RS232/485
Website: www.elsist.it
1.1
HMI SETTING:
Parameters
PLC type
PLC I/F
Baud rate
Data bits
Parity
Stop bits
PLC sta. nr
1.2
Recommended
SlimLine/Netsyst III RTU
RS232/RS485
115200
8
Even
1
1
PLC SETTING
Communication mode
1.3
Options
Notes
SlimLine/Netsyst III RTU/ASCII
RS232/RS485
9600/19200/38400/57600/115200
7,8
Even, Odd, None
1, 2
0-254 (255 Broadcast)
Modbus RTU (ASCII protocol option)
DEVICE ADDRESS
Bit/Word
Device type
Format
Range
B
%MX
DDDDD
0 - 65535
B
%MW_Bit
DDDDDdd
000 - 6553515
W
%MW
DDDDD
0 - 65535
1.4
Memo
0x01 Read coil
0x05 write single coil
0x03 Read holding register
0x06 write single register
0x03 Read holding register
0x10 write multiple registers
WIRING DIAGRAMS
Elsist SlimLine/Netsyst controllers Modbus RTU/ASCII
eMT3000 series
COM1 RS232
9P D-Sub Female
2 RX
3 TX
5 GND
COM3 RS232
9P D-Sub Female
8 RX
7 TX
5 GND
COMx RS232
RJ45 Male
6 TXD
5 RXD
4 GND
CMT/mTV series
COM1 RS232
9P D-Sub Female
2 RX
3 TX
5 GND
MNL178B100
COMx RS232
RJ45 Male
6 TXD
5 RXD
4 GND
Pag. 2/6
Manuale connessioni Weintek verso PLC Elsist
MT8000iE series (except MT8050iE)
COM1 RS232
9P D-Sub Female
2 RX
3 TX
5 GND
COMx RS232
RJ45 Male
6 TXD
5 RXD
4 GND
MT6050/8050 iP series and iE Series
COM1
RS232
9P D-Sub Female
9 RX
6 TX
5 GND
COMx RS232
RJ45 Male
6 TXD
5 RXD
4 GND
eMT3000 series
COM1 RS485 2W
9P D-Sub Male
1 Data2 Data+
5 GND
COM3 RS485 2W
9P D-Sub Female
6 Data9 Data+
5 GND
RS485 2W
3-Way TB
2 D1 D+
3 GND
1
MNL178B100
3
Pag. 3/6
Manuale connessioni Weintek verso PLC Elsist
CMT/mTV series
COM2 RS485 2W
9P D-Sub Female
7 Data6 Data+
5 GND
COM3 RS485 2W
9P D-Sub Female
4 Data1 Data+
5 GND
RS485 2W
3-Way TB
2 D1 D+
3 GND
1
3
MT8000iE series
COM1 RS485 2W
9P D-Sub Female
1 Data2 Data+
5 GND
COM3 RS485 2W
9P D-Sub Female
7 Data8 Data+
9 GND
RS485 2W
3-Way TB
2 D1 D+
3 GND
1
3
MT6050/8050iP series
COM1 RS485 2W
9P D-Sub Female
1 Data2 Data+
5 GND
COM3 RS485 2W
9P D-Sub Female
7 Data8 Data+
5 GND
RS485 2W
3-Way TB
2 D1 D+
3 GND
1
MNL178B100
3
Pag. 4/6
Manuale connessioni Weintek verso PLC Elsist
2
ELSIST TCP/IP
Supported devices: SlimLine & Netsyst controllers Ethernet TCP/IP
Website: www.elsist.it
2.1
HMI SETTING:
Parameters
PLC type
PLC I/F
Port no.
PLC sta. nr
2.2
Recommended
SlimLine/Netsyst III Eth
Ethernet
502
1
Notes
0-254 (255 Broadcast)
PLC SETTING
Communication mode
2.3
Options
Modbus TCP/IP
DEVICE ADDRESS
Bit/Word
Device type
Format
Range
B
%MX
DDDDD
0 - 65535
B
%MW_Bit
DDDDDdd
000 - 6553515
W
%MW
DDDDD
0 - 65535
2.4
Memo
0x01 Read coil
0x05 write single coil
0x03 Read holding register
0x06 write single register
0x03 Read holding register
0x10 write multiple registers
WIRING DIAGRAMS
Direct connection (crossover cable)
HMI RJ45 Male
1 TX+
2 TX3 RX+
4 BD4+
5 BD46 RX7 BD3+
8 BD3-
MNL178B100
Wire color
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
PLC RJ45 Male
3 RX+
6 RX1 TX+
4 Not Used
5 Not Used
2 TX7 Not Used
8 Not Used
Pag. 5/6
Manuale connessioni Weintek verso PLC Elsist
Through a hub/switch (pin-to-pin cable)
HMI RJ45 Male
1 TX+
2 TX3 RX+
4 BD4+
5 BD46 RX7 BD3+
8 BD3-
MNL178B100
Wire color (T568B)
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
PLC RJ45 Male
1 TX+
2 TX3 RX+
4 Not Used
5 Not Used
6 RX7 Not Used
8 Not Used