c-pro 3 series

c-pro 3 series
Programmable controllers
c-pro 3 is a range of programmable
controllers, I/O expansions and remote
user interfaces for applications in
refrigeration and air conditioning sectors.
Controllori programmabili
The controllers and the I/O expansions
have a considerable number of inputs and
outputs; they allow to realize a flexible,
modular and expandable control devices
network.
The remote user interfaces can easily
be integrated both in residential and
commercial environments; at their front
it is possible to apply the CPVP plates or
the plates belonging to the “Living” and
the “Light” series by BTicino.
Some of them incorporate a temperature
and humidity sensor (which survey can be
transmitted via BUS); others can work in
“commander” mode (getting the control
devices to serve the commands coming
from the interface).
The variety of available communication
ports (RS-485, CAN and USB) and
supported communication protocols make
easier the integration of the devices in
systems.
The application software can be realized
through the UNI-PRO 3 development
e n v i r o n m e n t f o r p r o g ra m m a b l e
controllers.
1
| Programmable controllers
Compatibile con
c-pro 3 è una gamma di controllori
programmabili, di espansioni di I/O e di
interfacce utente remote per applicazioni
appartenenti al settore della refrigerazione
e dell’aria condizionata.
I controllori e le espansioni di I/O
dispongono di un considerevole numero
di ingressi e di uscite; consentono di
realizzare una rete flessibile, modulare
ed espandibile di dispositivi di controllo.
Le interfacce utente remote sono
facilmente integrabili sia in ambienti
residenziali che commerciali; al loro
frontale è possibile applicare le placche
CPVP o le placche appartenenti alla serie
“Living” e alla serie “Light” BTicino.
Alcune di esse incorporano un sensore di
temperatura e di umidità (il cui rilievo può
essere trasmesso via BUS); altre possono
funzionare in modalità “commander”
(facendo servire ai dispositivi di controllo
le richieste provenienti dall’interfaccia).
La varietà di porte di comunicazione
disponibili (di tipo RS-485, CAN e USB) e
di protocolli di comunicazione supportati
favoriscono l’integrazione dei dispositivi
in sistemi.
Il software applicativo può essere
realizzato con l’ambiente di sviluppo per
controllori programmabili UNI-PRO 3.
Where | Dove
TOP
PLUS
Flexibility, modularity and expandability.
Flessibilità, modularità ed espandibilità.
1
Air handling units.
2
Heat pumps.
3
Chillers.
Unità trattamento aria.
Advantages | Vantaggi
Variety of control devices with a considerable number of inputs and outputs.
Varietà di dispositivi di controllo con un considerevole numero di ingressi e di uscite.
Variety of communication ports (RS-485, CAN and USB) and supported communication protocols,
to make easier the integration of the devices in systems.
Varietà di porte di comunicazione (di tipo RS-485, CAN e USB) e di protocolli di comunicazione
supportati, per favorire l’integrazione dei dispositivi in sistemi.
Easy integration of the remote user interfaces both in residential and commercial environments.
Facile integrazione delle interfacce utente remote sia in ambienti residenziali che commerciali.
Pompe di calore.
Main features | Caratteristiche principali
Models in built-in or blind version.
Modelli in versione built-in o cieca.
Control devices in standard size 4 or 10 DIN modules.
Dispositivi di controllo in formato standard 4 o 10 moduli DIN.
Control devices OEM oriented.
Dispositivi di controllo finalizzati agli OEM.
Chiller.
Control devices with integrated unipolar stepper electronic expansion valves driver.
Dispositivi di controllo con driver per valvole di espansione elettroniche di tipo stepper unipolare
integrato.
Remote user interfaces with colour touch-screen TFT graphic display.
Interfacce utente remote con visualizzatore grafico TFT touch-screen a colori.
Remote user interfaces with temperature and humidity sensor incorporated (which survey can
be transmitted via BUS).
Interfacce utente remote con sensore di temperatura e di umidità incorporato (il cui rilievo può
essere trasmesso via BUS).
Controllori programmabili |
2
Technical features | Caratteristiche tecniche
Programmable controllers
Controllori programmabili
Version | Versione
blind | cieca
built-in LED (4+4 digits custom display) | built-in LED (display custom da 4+4 digit)
built-in LCD (122 x 32 pixel single colour LCD graphic display)
built-in LCD (visualizzatore grafico LCD monocolore da 122 x 32 pixel)
built-in LCD (128 x 64 pixel single colour LCD graphic display)
built-in LCD (visualizzatore grafico LCD monocolore da 128 x 64 pixel)
Dimensions | Dimensioni
DIN modules | moduli DIN
Connections | Connessioni
Micro-Fit connectors | connettori Micro-Fit
removable clamp connection terminal blocks | morsettiere estraibili a molla
removable screw connection terminal blocks | morsettiere estraibili a vite
The programmable controllers are available in the
standard size 4 or 10 DIN modules and in different
versions (blind, built-in LED or built-in LCD).
Installation is on DIN rail, into a control panel.
I controllori programmabili sono disponibili nel formato
standard 4 o 10 moduli DIN e in diverse versioni (cieca,
built-in LED o built-in LCD).
L’installazione è prevista su guida DIN, in un quadro
di controllo.
Power supply | Alimentazione
12 VAC not isolated | 12 VAC non isolata
24 VAC/DC not isolated | 24 VAC/DC non isolata
24 VAC/DC isolated | 24 VAC/DC isolata
Analog inputs | Ingressi analogici
NTC
NTC/0-20 mA/4-20 mA
PTC/NTC/Pt 1000
PTC/NTC/Pt 1000/0-20 mA/4-20 mA/0-5 V ratiometric/0-10 V
PTC/NTC/NTC type 2/NTC type 3/Pt 1000/0-20 mA/4-20 mA/0-5 V ratiometric/0-10 V
Digital inputs (for NO/NC contact) | Ingressi digitali (per contatto NA/NC)
non optoisolated free of voltage contacts | contatti puliti non optoisolati
optoisolated 24 VAC/DC 50/60 Hz contacts | contatti a 24 VAC/DC 50/60 Hz optoisolati
optoisolated 24 VAC/DC 2 KHz contacts | contatti a 24 VAC/DC 2 KHz optoisolati
Analog outputs | Uscite analogiche
PWM
PWM/0-10 V
0-10 V
0-20 mA/4-20 mA/0-10 V
Digital outputs (electromechanical relays; res. A @ 250 VAC)
Uscite digitali (relè elettromeccanici; A res. @ 250 VAC)
3 A SPST
3 A SPDT
5 A SPST
5 A SPDT
8 A SPST
8 A SPDT
Digital outputs (command for solid state relay) | Uscite digitali (comando per relè allo stato solido)
24 VAC/DC, 0.6 mA max
Communication ports | Porte di comunicazione
non optoisolated TTL, for programming | TTL non optoisolata, di programmazione
non optoisolated MODBUS slave RS-485 | RS-485 MODBUS slave non optoisolata
non optoisolated MODBUS master/slave RS-485 | RS-485 MODBUS master/slave non optoisolata
non optoisolated CANBUS CAN | CAN CANBUS non optoisolata
non optoisolated USB | USB non optoisolata
Other features | Altre caratteristiche
real time clock | orologio
alarm buzzer | buzzer di allarme
integrated unipolar stepper electronic expansion valves driver
driver per valvole di espansione elettroniche di tipo stepper unipolare integrato
3
Notes | Note
(1) the PWM analog output is not independent
but works in the same way to another one |
l’uscita analogica non è indipendente ma
funziona allo stesso modo di un’altra.
| Programmable controllers
Available options | Opzioni disponibili
None | Nessuna.
•
•
•
•
•
EPM4DXP
EPM4BXP
EPM4D
•
EPM4B
EPH4BXP
•
EPH4DXP
EPH4B
•
EPK3DEV
•
c-pro 3 hecto c-pro 3 hecto+ c-pro 3 mega c-pro 3 mega+
EPK3DSR
EPK3BEV
•
EPK3DXP
EPK3BSR
•
c-pro 3 kilo+
EPK3BXP
EPK3L
EPK3B
•
EPU2LEV
•
c-pro 3 kilo
EPU2LSR
EPU2BEV
•
EPU2LXP
EPU2BSR
•
c-pro 3 micro+
EPU2BXP
EPU2L
EPU2B
c-pro 3 micro
•
•
•
4
4
4
4
4
4
4
4
•
•
•
4
4
4
4
4
4
4
4
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
3
3
6
6
6
6
6
6
•
•
4
4
4
10
10
10
10
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
3
3
5
5
12
12
3
3
3
5
5
5
3
3
7
7
7
7
7
7
3
3
7
7
7
7
7
7
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
2
2
2
2
2
2
1
1
2
2
2
2
2
2
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1
2
2
2
2
5
5
7
7
1 (1)
1 (1)
1
1
2
2
5
5
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
•
•
•
•
•
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
•
•
•
•
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
•
•
•
•
•
•
•
•
•
1
•
2
2
2
3
3
5
5
4
4
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
•
•
•
•
•
•
•
2
2
1
1
1
2
2
5
2
1
2
•
•
•
•
Controllori programmabili |
4
Technical features | Caratteristiche tecniche
I/O expansions
Espansioni di I/O
Version | Versione
blind | cieca
Dimensions | Dimensioni
DIN modules | moduli DIN
Connections | Connessioni
Micro-Fit connectors | connettori Micro-Fit
removable clamp connection terminal blocks | morsettiere estraibili a molla
removable screw connection terminal blocks | morsettiere estraibili a vite
Power supply | Alimentazione
12 VAC not isolated | 12 VAC non isolata
24 VAC/DC not isolated | 24 VAC/DC non isolata
The I/O expansion are available in the standard size 4
DIN modules and in blind version.
Installation is on DIN rail, into a control panel.
Le espansioni di I/O sono disponibili nel formato
standard 4 moduli DIN e in versione cieca.
L’installazione è prevista su guida DIN, in un quadro
di controllo.
24 VAC/DC isolated | 24 VAC/DC isolata
Analog inputs | Ingressi analogici
NTC
PTC/NTC/Pt 1000
PTC/NTC/Pt 1000/0-20 mA/4-20 mA/0-5 V ratiometric/0-10 V
Digital inputs (for NO/NC contact) | Ingressi digitali (per contatto NA/NC)
non optoisolated free of voltage contacts | contatti puliti non optoisolati
optoisolated 24 VAC/DC 50/60 Hz contacts | contatti a 24 VAC/DC 50/60 Hz optoisolati
optoisolated 24 VAC/DC 2 KHz contacts | contatti a 24 VAC/DC 2 KHz optoisolati
Analog outputs | Uscite analogiche
PWM
PWM/0-10 V
0-10 V
0-20 mA/4-20 mA/0-10 V
Digital outputs (electromechanical relays; res. A @ 250 VAC)
Uscite digitali (relè elettromeccanici; A res. @ 250 VAC)
3 A SPST
3 A SPDT
5 A SPST
5 A SPDT
8 A SPST
8 A SPDT
Digital outputs (command for solid state relay) | Uscite digitali (comando per relè allo stato solido)
24 VAC/DC, 0.6 mA max
Communication ports | Porte di comunicazione
non optoisolated TTL, for programming | TTL non optoisolata, di programmazione
non optoisolated CANBUS CAN | CAN CANBUS non optoisolata
non optoisolated USB | USB non optoisolata
Notes | Note
(1) the PWM analog output is not independent
but works in the same way to another one |
l’uscita analogica non è indipendente ma
funziona allo stesso modo di un’altra.
5
| Programmable controllers
Available options | Opzioni disponibili
None | Nessuna.
•
•
•
•
•
•
•
MODBUS
master/slave
RS-485 port
•
•
DI1
DI3
DI2
DI5
DI4
COM
AO1
AO3
AO2
AI5
AI6
+5V
analog inputs 7... 9,
digital inputs 6... 9 and
analog outputs 4... 6
1
ON
DI9
•
DI8
•
COM
•
DI7
•
DI6
•
GND
•
A/+
•
1 2
ON
RS-485 port
and CAN port
line termination
GND
4
AI4
4
AO6
4
+12V
4
AI1
4
AI3
4
analog inputs 1... 6,
digital inputs 1... 5 and
analog outputs 1... 3
USB port
AI2
4
V@
4
power supply,
MODBUS slave
RS-485 port and
CANBUS CAN port
AI9
•
AO5
•
AO4
•
AI7
•
AI8
•
GND
•
V@
EPH4EXP
•
Programmable controllers
Controllori programmabili
A/+
EPH4E
•
Connections
Connessioni
CAN +
EPK3ESR
c-pro 3
EXP hecto+
EPK3EXP
c-pro 3
EXP hecto
EPK3E
c-pro 3
EXP kilo+
EPU2ESR
c-pro 3 EXP kilo
EPU2EXP
c-pro 3
EXP micro+
EPU2E
c-pro 3
EXP micro
RS-485 port
line termination
•
•
•
•
•
•
EPU2BXP
c-pro 3 micro+
K8
K9
1
3
3
CO8
NO8
NC8
CO9
digital output 8
5
1
2
2
2
2
1
2
2
2
2
2
2
7
7
7
NO2
CO
1/2
NO3
NO4
NO5
CO
3/4/5
digital outputs 1... 5
2
2
power supply and
CANBUS CAN port
7
5
analog inputs 1... 6,
digital inputs 1... 5 and
analog outputs 1... 3
USB port
1 2
ON
CAN port
line termination
2
5
DI9
DI8
COM
DI7
DI6
AO6
AO5
AO4
AI7
EPU2EXP
GND
1
analog inputs 7... 9,
digital inputs 6... 9 and
analog outputs 4... 6
AI9
7
2
NO1
I/O expansions
Espansioni di I/O
V@
7
CO
6/7
DI1
2
2
NO7
digital outputs 6 and 7
V@
1
2
1 (1)
AI8
2
NO6
K5
DI3
2
K4
DI2
2
K3
DI5
2
K2
DI4
2
K1
COM
2
K7
AO3
2
K6
5
AO2
7
AI5
7
AI6
3
NC9
AO1
7
A/+
7
CAN +
3
NO9
digital output 9
AI4
6
+5V
3
6
GND
3
3
AI3
3
6
AI2
3
6
+12V
3
3
AI1
3
c-pro 3 EXP micro+
K8
1
2
CO8
1
1
1
1
1
1
1
1
1
1
1
1
K6
K7
NO6
NO7
CO
6/7
digital outputs 6 and 7
NC9
K1
K2
NO1
NO2
CO
1/2
K3
K4
K5
NO3
NO4
NO5
CO
3/4/5
digital outputs 1... 5
Remote user interfaces
Interfacce utente remote
USB port
+
5
4
+
EPV4CBR
Vcolor
3
2
gnd
RS-485 port and CAN port
line termination
1
+
power
supply
1
NO9
CANBUS CAN
port
1
CO9
digital output 9
1 2
1
NC8
7
6
Controllori programmabili |
MODBUS
RS-485 port
1
NO8
digital output 8
ON
2
K9
6
Technical features | Caratteristiche tecniche
EPV4TBR
EPV3RBR
EPV4RBR
EPV4CBR
Vcolor
EPV3TBR
Vroom
EPV4GBR
Vtouch
EPV3GBR
Remote user interfaces
Interfacce utente remote
Vgraph
•
•
•
•
•
•
•
Operating mode | Modalità di funzionamento
browser | browser
•
commander (1) | commander (1)
Display | Visualizzatore
128 x 64 pixel single colour LCD graphic display
visualizzatore grafico LCD monocolore da 128 x 64 pixel
•
•
240 x 140 pixel single colour touch-screen LCD graphic
display | visualizzatore grafico LCD touch-screen monocolore
da 240 x 140 pixel
•
•
•
•
320 x 240 pixel colour touch-screen TFT graphic display
visualizzatore grafico TFT touch-screen a colori da 320 x 240
pixel
•
Power supply | Alimentazione
The remote user interfaces are available with different
typologies of display (LCD, touch-screen LCD or touchscreen TFT).
Installation is by panel or by wall (in flush box belonging
to the “506e” series by BTicino or in CPVW00 wall
mounting support).
Le interfacce utente remote sono disponibili con diverse
tipologie di visualizzatore (LCD, LCD touch-screen o
TFT touch-screen).
L’installazione è prevista a pannello o a muro (in scatola
da incasso appartenente alla serie “506e” BTicino o in
supporto per installazione a parete CPVW00).
12-24 VAC/24 VDC isolated | 12-24 VAC/24 VDC isolata
•
•
•
24 VAC/DC not isolated | 24 VAC/DC non isolata
•
•
•
•
Incorporated sensors | Sensori incorporati
temperature | di temperatura
•
•
humidity | di umidità
•
•
1
1
Communication ports | Porte di comunicazione
non optoisolated TTL, for programming
TTL non optoisolata, di programmazione
1
1
1
1
non optoisolated MODBUS master/slave RS-485
RS-485 MODBUS master/slave non optoisolata
non optoisolated CANBUS CAN
CAN CANBUS non optoisolata
1
1
1
1
1
1
1
non optoisolated USB | USB non optoisolata
1
1
Other features | Altre caratteristiche
real time clock | orologio
•
•
•
•
•
•
•
alarm buzzer | buzzer di allarme
•
•
•
•
•
•
•
Notes | Note
(1) or getting the control devices to serve the
commands coming from the interface | ovvero
facendo servire ai dispositivi di controllo le
richieste provenienti dall’interfaccia.
Available options | Opzioni disponibili
None | Nessuna.
For other models please contact the EVCO sales network | Per ulteriori modelli contattare la rete vendita EVCO.
7
| Programmable controllers
Dimensions
mm (in)
| Dimensioni
mm
Programmable controllers and I/O expansions
Controllori programmabili ed espansioni di I/O
10 DIN modules
71.0 (2.795)
179.0 (7.047)
128.0 (5.039)
4 DIN modules
60.0 (2.362)
Remote user interfaces
Interfacce utente remote
48.5 (1.909)
81.5 (3.208)
118.0 (4.645)
118.0 (4.645)
70.0 (2.755)
104.0 (4.094)
71.5 (2.814)
41.8 (1.645)
58.0 (2.283)
53.5 (2.106)
26.7
(1.051)
111.0 (4.370)
Vtouch
30.0
(1.181)
Vgraph and Vroom
23.0
(0.905)
118.0 (4.645)
Vcolor
Controllori programmabili |
8
How | Come
Programmable controllers and I/O expansions
Controllori programmabili ed espansioni di I/O
frontal plate
placca frontale
wall
Remote user interfaces
| Interfacce utente remote
muro
Installation by panel | Installazione a pannello.
remote user interface
interfaccia utente remota
screw
vite
Installation by wall (in flush box belonging to the “506e” series by
flush mounting box
belonging to the
“506e” series by BTicino
BTicino)
| Installazione
scatola
da incasso a muro
della serie “506e” BTicino
(in scatola da incasso appartenente alla serie “506e” BTicino).
Installation by wall (in CPVW00 wall mounting support) | Installazione a muro (in supporto per installazione a parete CPVW00).
9
| Programmable controllers
Accessories | Accessori
Connecting cables
Cavi di connessione
0810500018/0810500020
Programming kit
Kit di programmazione
EVIF20TUXI
4 GB USB flash drive
Chiave USB da 4 GB
EVUSB4096M
Using the cables it is possible to program the controller
(as long as it has the USB communication port).
Cable 0810500018 is 2.0 m (6.561 ft) long; cable
0810500020 is 0.5 m (1.640 ft) long.
Using the kit it is possible to program the controller (as
long as it has the TTL communication port).
Using the flash drive it is possible to upload and
download the controller configuration parameters (as
long as it has the USB communication port).
Attraverso i cavi è possibile programmare il controllore
(a condizione che questi disponga della porta di
comunicazione di tipo USB).
Il cavo 0810500018 è lungo 2,0 m (6,561 ft); il cavo
0810500020 è lungo 0,5 m (1,640 ft).
Attraverso il kit è possibile programmare il controllore
(a condizione che questi disponga della porta di
comunicazione di tipo TTL).
Attraverso la chiave è possibile eseguire l’upload e il
download dei parametri di configurazione del controllore
(a condizione che questi disponga della porta di
comunicazione di tipo USB).
Programming key
Chiave di programmazione
EVKEY10
Non optoisolated RS-485/USB
serial interface | Interfaccia seriale
RS-485/USB non optoisolata
EVIF20SUXI
Splitter RJ45 M/2 RJ45 F
Accoppiatore RJ45 M/2 RJ45 F
0810500016
Using the key it is possible to upload and download the
controller configuration parameters (as long as it has
the TTL communication port).
Using the interface it is possible to connect the controller
to the Parameters Manager software set-up system.
Using the splitter it is possible to connect the controller
c-pro 3 hecto, c-pro 3 hecto+, c-pro 3 mega and
c-pro 3 mega+ to a RS-485 devices network reducing
the wiring work to a minimum.
Attraverso la chiave è possibile eseguire l’upload e il
download dei parametri di configurazione del controllore
(a condizione che questi disponga della porta di
comunicazione di tipo TTL).
Attraverso l’interfaccia è possibile collegare il controllore
al sistema software di set-up Parameters Manager.
Attraverso l’accoppiatore è possibile collegare il
controllore c-pro 3 hecto, c-pro 3 hecto+, c-pro 3
mega e c-pro 3 mega+ a una rete di dispositivi di
tipo RS-485 riducendo le opere di cablaggio al minimo.
Serial probes
Sonde seriali
EPV3P/EPV4P (Vprobe)
Cut phase speed regulator for singlephase fans
Regolatore di velocità a taglio di fase
per ventilatori monofase
EVDFAN1
Frontal plates
Placche frontali
CPVP
Using the probes it is possible to read the temperature
and humidity value and transmit it via BUS.
Using the regulator it is possible to change the fan speed.
The drive signal is PWM; the maximum working current
is 5 A.
Using the plates it is possible to integrate the remote
user interface both in residential and commercial
environments.
Attraverso il regolatore è possibile variare la velocità
del ventilatore.
Il segnale di comando è di tipo PWM; la massima
corrente operativa è di 5 A.
Attraverso le placche è possibile integrare l’interfaccia
utente remota sia in ambienti residenziali che
commerciali.
Attraverso le sonde è possibile rilevare il valore della
temperatura e dell’umidità e trasmetterlo via BUS.
Power supply
Alimentazione
Code | Codice
12-24 VAC/24 VDC isolated
12-24 VAC/24 VDC isolata
EPV3P
24 VAC/VDC not isolated
24 VAC/DC non isolata
EPV4P
Colour | Colore
Code | Codice
white | bianco
CPVP00
black | nero
CPVP01
Controllori programmabili |
10
Wall mounting support
Supporto per l’installazione a parete
CPVW00
Using the support it is possible to mount the remote user
interface reducing the mounting work to a minimum.
Attraverso il supporto è possibile installare l’interfaccia
utente remota riducendo le opere di installazione al
minimo.
11
| Programmable controllers
Gasket
Guarnizione
0027000007
Connecting kits
Kit di collegamento
CJAV
Using the gasket it is possible to guarantee the remote
user interface an IP65 protection rating when it is
panel mounted.
Using the kits it is possible to wire the controller and
the I/O expansion.
Attraverso la guarnizione è possibile garantire all’interfaccia utente remota un grado di protezione IP65
quando questa è installata a pannello.
Attraverso i kit è possibile cablare il controllore e l’espansione di I/O.
Device | Dispositivo
Code | Codice
c-pro 3 micro
CJAV18+CJAV19
c-pro 3 micro+
CJAV18+CJAV19
c-pro 3 kilo
CJAV18+CJAV20
c-pro 3 kilo+
CJAV18+CJAV20
c-pro 3 hecto
CJAV15
c-pro 3 hecto+
CJAV15
c-pro 3 mega
CJAV16
c-pro 3 mega+
CJAV21
c-pro 3 EXP micro
CJAV18+CJAV19
c-pro 3 EXP micro+
CJAV18+CJAV19
c-pro 3 EXP kilo
CJAV18+CJAV20
c-pro 3 EXP kilo+
CJAV18+CJAV20
c-pro 3 EXP hecto
CJAV15
c-pro 3 EXP hecto+
CJAV15
Overview drawing c-pro 3 series | Vista d’insieme serie c-pro 3
CPVP
Frontal plates
Placche frontali
c-pro 3 EXP micro+
I/O expansion
Espansione di I/O
CPVW
Wall mounting support
Supporto per l'installazione a parete
EVDRIVE03
Electronic expansion valves driver
Driver per valvole di espansione elettroniche
0027000007
Gasket
Guarnizione
Vprobe
Vcolor
Serial probes
Remote user interface
Interfaccia utente remota Sonde seriali
CANBUS CAN
CAN CANBUS
ECTSF
Safety transformers
Trasformatori di sicurezza
CJAV19
Connecting kit
Kit di collegamento
Dado
Ethernet gateway
Gateway Ethernet
Power supply
Alimentazione
Plant monitoring and supervision system (via Web) CloudEvolution
Sistema di monitoraggio e di supervisione di impianti (via Web) CloudEvolution
MODBUS slave RS-485
RS-485 MODBUS slave
0810500018/0810500020
Connecting cables
Cavi di connessione
USB
USB
MODBUS master RS-485
RS-485 MODBUS master
Personal Computer with UNI-PRO 3 installed
Personal Computer con UNI-PRO 3 installato
EVIF20SUXI
RS-485/USB serial interface
Interfaccia seriale RS-485/USB
USB
USB
Personal Computer with Parameters Manager installed
Personal Computer con Parameters Manager installato
Third part
devices
Dispositivi di
terze parti
EVTP, EVHP, EVPT
Temperature probes, humidity transducers, pressure transducers
Sonde di temperatura, trasduttori di umidità, trasduttori di pressione
EVUSB4096M
4 GB USB flash drive
Chiave USB da 4 GB
USB
USB
Devices by EVCO
Dispositivi EVCO
CJAV19
Connecting kit
Kit di collegamento
Analog inputs
Ingressi analogici
Programming key
Chiave di programmazione
CJAV19
Connecting kit
Kit di collegamento
Digital inputs
Ingressi digitali
EVDFAN1
Cut phase speed regulator
Regolatore di velocità a taglio di fase
Analog outputs
Uscite analogiche
CJAV18
Connecting kit
Kit di collegamento
CJAV18
Connecting kit
Kit di collegamento
Integrated unipolar stepper electronic expansion valves driver
Driver per valvole di espansione elettroniche di tipo stepper unipolare integrato
Digital outputs
Uscite digitali
Controllori programmabili |
12