Meridian Healthcare medical diagnostics and equipment www.meridianhealthcare.it D-10™ Hemoglobin Testing System This fully automated system combines diabetes monitoring and β-thalassemia testing on a single platform ♦ Fully automated system ♦ Direct Testing in whole blood ♦ Touch screen and automatic sample barcode ♦ Simple and efficient operation for clinical laboratories ♦ Select programs for fast HbA 1c or HbA 2 /F ♦ NGSP certification ORDERING INFORMATION: Code No. Product Pack-size 220-0220 D10 Hemoglobin Testing System 1 unit Analizzatore Automatico D-10 Hemoglobin Testing System per il dosaggio in HPLC dell’ HbA 1c e la β-talassemia. ♦ Analizzatore totalmente automatico ♦ Utilizzo provetta primaria e barcode campioni ♦ Touch screen e stampante termica ♦ Reagenti liquidi e pronti all’uso ♦ Calibratori e colonna inclusi nel kit ♦ Eccellente precisione e dosaggio delle varianti emoglobiniche ♦ Certificazione NGSP Meridian Healthcare official authorized distributor BIO-RAD Meridian Healthcare srl Tel: +39 095 419 88 60 - +39 095 725 68 69 Fax: +39 095 725 44 54 mail: [email protected] [email protected] Patient report Bio-Rad D-10 S/N: #DA5A427320 Sample ID: Injection date Injection #: 8 Rack #: --- Peak table - ID: Peak A1a A1b LA1c/CHb-1 A1c P3 A0 A2 Total Area: DATE: 03/17/2010 TIME: 01:30 PM Software version: 3.50-A1 03/17/2010 12:55 PM Method: HbA2/F Rack position: 4 R.time 0.20 0.28 0.62 0.78 1.48 1.74 3.18 1311157 Concentration: % A1c 5.7 % A2 1.9 Height 3118 3333 2684 5812 6671 217753 1291 Area 10927 24777 20392 57214 65236 1109573 23040 Area % 0.8 1.9 1.6 5.7 5.0 84.6 1.9 Patient report Bio-Rad D-10 S/N: #DA5A427320 Sample ID: Injection date Injection #: 11 Rack #: --- Peak table - ID: Peak A1b F LA1c/CHb-1 A1c P3 A0 A2 Total Area: DATE: 04/08/2010 TIME: 11:33 AM Software version: 3.50-A1 04/08/2010 11:15 AM Method: HbA2/F Rack position: 1 R.time 0.28 0.46 0.66 0.81 1.46 1.68 3.17 2011138 Concentration: %F 2.2 % A1c 4.4 % A2 3.0 Height 5094 7881 2268 6348 8287 316904 3047 Area 43494 46364 16877 62495 76309 1710047 55553 Area % 2.2 2.2 0.8 4.4 3.8 85.0 3.0 Patient report Bio-Rad D-10 S/N: #DA5A427320 Sample ID: Injection date Injection #: 9 Rack #: --- Peak table - ID: Peak A1a A1b F LA1c/CHb-1 A1c P3 A0 A2 Total Area: DATE: 03/17/2010 TIME: 01:29 PM Software version: 3.50-A1 03/17/2010 01:02 PM Method: HbA2/F Rack position: 5 R.time 0.21 0.28 0.42 0.61 0.74 1.45 1.66 3.01 3682584 Concentration: %F < 0.8 % A1c 5.1 % A2 2.8 Height 7278 8865 6416 5975 14938 13545 517145 4019 Area 23731 43845 37120 35474 145953 153043 3140113 103306 Area % 0.6 1.2 < 0.8 1.0 5.1 4.2 85.3 2.8
© Copyright 2024 Paperzz