S.Giusta 11_12 Aprile 2015

Number
KIP-079059/01
Replace
-
Issued
01-08-2013
Scope
PV Certification
Expiry date
31-07-2014
Contract Number
KIP PV 230
Report n.
110900887
Page
1 of 2
Factory Inspection Certificate
License holder:
Lenus Solar S.r.l.
Via Giotto 5 - 39100 Bolzano (BZ), Italy
Production site:
1)
2)
Revolution 6 Incorporated Khrystyna Johnson
U.L. Kochanowskiego 30/25 - 33-100 Tarnów, Poland
Solvis d.o.o.
Gospodarska zona Brezje bb, P.O.B. 113
HR-42000 Varazdin, Croatia
Production site ref. nr:
KIP PV 230 001
KIP PV 230 003
Products:
Models:
PV modules
Lenus Premium Power AMXXXP and AMXXXM
Lenus Premium Power R-IN XXXP
(XXX suffix indicates rated power)*
During the periodic inspection of the production site(s) according to “DT Ki – 0409”,
were checked the production steps, verifying that the technical characteristics of the products, listed
above, comply with the type approval certification in according to the standards IEC (EN) 61215:2005,
IEC (EN) 61730-1:2004** and IEC (EN) 61730-2:2004.
Laboratory tests have been performed by Laboratory tests have been performed by:
Laboratory Testing of the panels, which are performed by an accredited laboratory in accordance to EN
ISO/IEC 17025: 2005 – see annex.
The products are fully produced in the EU territory and therefore are in compliance with the
requirements for the ‘Made in EU’ of the Italian law ‘V Conto Energia per il Fotovoltaico’ – D.M. 5
Luglio 2012 and application rules: GSE August 2012 paragraph 4.4.
Production steps:
Production capacity:
Module serial number
sequence:
Kiwa Italia S.p.a.
Sede Legale:
Via Goffredo Mameli, 20
20129 Milano
Sede Amministrativa e operativa:
Via Treviso, 32/34
31020 San Vendemiano (TV)
www.1kiwa.com
Complete Production:
string, assembling, lamination and electrical test
Site 1: Maximum 30 MW/year
Site 2: Maximum 30 MW/year
On Product ID label: (Lenus Premium Power AMXXXP;
AMXXXM; Lenus Premium Power R-IN XXXP)
Site 1: Module serial number below the bar code:
26YYMMXXXXXXX
26: production site encoded by 26 (KIP PV 230 001)
YY: year of production
MM: month of production
XXXXXXX: unique production serial number from
0000001 to 9999999
Site 2: Module serial number below the bar code:
231XXXXXXXXXX
231: production site encoded by 231 (KIP 230 003)
XXXXXXXXXX: unique production serial number
Bouke Meekma
Kiwa
Member of the IECEE CB scheme
KIP PV 230 001
KIP PV 230 003
Number
KIP-079059/01
Replace
-
Issued
01-08-2013
Scope
PV Certification
Expiry date
31-07-2014
Contract Number
KIP PV 230
Report n.
110900887
Page
2 of 2
Annex
Extended models*
(Types extended for similarity without need of re-testing according to IECEE “Retesting
Guideline”)
Model name
Lenus Premium Power:
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXP
AMXXXM
AMXXXM
AMXXXM
AMXXXM
R-INXXXP
R-INXXXP
R-INXXXP
R-INXXXP
Cell
number
Cell size
(mm)
Cell
technology
Rated power
(Wp)
60
54
50
48
40
36
24
18
12
60
48
36
36
60
36
24
12
156x156
156x156
156x156
156x156
156x156
156x156
156x156
156x156
156x156
156x156
156x156
156x156
125x125
156x156
156x156
156x156
156x156
Poly
Poly
Poly
Poly
Poly
Poly
Poly
Poly
Poly
Mono
Mono
Mono
Mono
Poly
Poly
Poly
Poly
From 210 to 260 with 5 steps
From 180 to 220 with 5 steps
From 175 to 205 with 5 steps
From 160 to 205 with 5 steps
From 140 to 165 with 5 steps
From 110 to 155 with 5 steps
From 90 to 100 with 5 steps
From 65 to 75 with 5 steps
From 45 to 50 with 5 steps
From 210 to 275 with 5 steps
From 170 to 215 with 5 steps
From 125 to 160 with 5 steps
From 80 to 100 with 5 steps
From 200 to 245 with 5 steps
From 110 to 150 with 5 steps
From 90 to 100 with 5 steps
From 45 to 50 with 5 steps
Bouke Meekma
Kiwa
Laboratory tests have been performed by: Eurotest Laboratori S.r.l. (EA accredited lab. nr. 0192)
report nr. PVC01 CDO 09C463002, PVQ01-25638-130010, PS101-25638-130010, PS102-25638-130010,
PVQ02-25638-130010, PS201-25638-130010, PS202-25638-130010;
Eurofins Modulo Uno testing laboratory (EA accredited lab. nr. 0085) report nr. M1.09.FVOL.500/37423Rev1,
M1.10.FVOL.0645/41130.
**Remarks: test and documental review performed according to the standard IEC 61730-1:2004 only for PV modules
manufactured by Solvis d.o.o. (site 2).