MIC-L/H Feed Throat Tenperature Controller for Molding Machine Summary MIC-L MIC is the cooling unit for material port of injection- molding machine which realized stable temperature control and high safety. The cooling water connection of primary side is unnecessary in the air-cooled type which takes utility into consideration. Temp Display/ Setting: Temp Controller: Features The cooling water is unnecessary for air-cooling type. The water supply utility can be removed and the energy saving is possible. Moreover, equipment itself is designed for energy saving. Heating & Cooling PID Control K Input: Energy Saving Digital Display/ Setting Memory: SV1 SV2 Timer: 0 99hrs. 59min.(Turns ON After Setting) 7 Segments Indication: (Cord Indication) Operation Status, Alarm (Reverse Phase, Insufficient Water, Overwork of Pump, Overheating, Under Heating, Sensor Failure) Stabilization of molding quality Quiet noise and without water leakage trouble There is not water leakage for using a canned pump. Also, there is a little equipment noise. Stable temperature control precision The material biting insert becomes improving when making the material inlet temperature for injection machine be stable and the molding quality is stable. In precise molding, the material inlet temperature affects to material measuring precision. And the material is PA, LCP, etc. It is possible to perform software control for cooling control with air-cooling. Compact Setup in the injection machine is easy because the mechanism is simple and compact. In case of the small mold, it is possible to using as the mold temperature controller. In the area of general mold temperatures in range of 60°C~70°C, demonstrates capable cooling functions It doesn't fit the thin mold of cooling pipe because the drain pressure is low. Also, it isn't possible to cool less than the room temperature. Installs to low place of equipment ambient temperature. Pump Performance Curves 9 Lift 8 7 6 60Hz 5 New patent application about the cooling method for air-cooling: Japan 1 50Hz 4 3 Model Medium Clamp Force for Injection-Molding Machine MIC-L MIC-H Cooling Type (Ambient Temperature +10~90°C) 2 1 0 10 20 Flow Rate (L/min) 30 40 Primary side water supply is unnecessary! Without Water Supply Mizuirazu (Non-Water) Supply the circulation medium (Clean water With anti-rust) only once. Hopper on Injection-Moldeing Machine MIC-L/H Feed Throat Tenperature Controller for Molding Machine Constant supply is unnecessary to clean cooling tower water, etc. Cylinder Section Outer Dimension MIC-L/H D Unit:mm D1 W D2 Temperature Controller MIC-L/H Cleaning Tower H Standard Specifications Unit MIC-L MIC-H V Voltage Apparent Power VA Breaker Capacity A 1Phase Operational Temperature Range Medium Equipment Ambient Temperature+10 Clean Water 90 Antirust Water Control Temperature-Ambient Temperature Cooling Capacity kW kW kW kW kW kW Heater kW Capacity Pump Maximum Flow Rate Cooling Fan Temperature Controller Output kW Output W Temperature Sensing Element Heat Exchanger Aluminum Material Volume L Medium Level Low/Overheat Alarm(H Type Only) Alarm Output Dry Breaker Points Pipe Diameter Medium Feed Port Medium Return Port Drain Port Medium Refueling Port Product Weight kg Options Standard Hose Set NOTE Leakage Breaker General Alarm Output Remorte ON/OFF Input 1 Required water quality: Add the antirust to the equivalent grade of Japan Refrigeration and Air-condition Industry Standard for make-up water (With least PH6 to 8 calcium, silica, chlorine, iron content.) Recommends Matsui antirust. 2 In heat overload exceeding cooling capacity, it isn’t possible to perform temperature control. 3 Uses in maximum flow rate. The flow rate decreases when installing a valve in the middle of a pipeline. Therefore, don’t set the valves. 4 The outer dimensions doesn't include pipe and reserve tank. The pipe port sometimes changes with the convenience of customer. Temperature Controller Model Power Supply
© Copyright 2026 Paperzz