NXE1 Series w w w.m urata-p s.com Isolated 1W Single Output SM DC/DC Converters Isolation Capacitance mA % % mVp-p mVp-p % % pF kHrs 5 200 7.8 10 28 50 65 69 8 6384 MTTF2 Efficiency (Typ) V 5 Efficiency (Min) Output Ripple & Noise (Max) Load Regulation (Typ) V NXE1S0505MC Output Current Output Ripple & Noise (Typ) ・ ・Patents pending Load Regulation (Max) FEATURES Output Voltage Order Code1 Nominal Input Voltage SELECTION GUIDE ・ ・Lower Profile INPUT CHARACTERISTICS ・ ・UL60950 Recognition pending Parameter Conditions Min. Typ. Max. Units Continuous operation, 5V input types 4.5 ・ ・UL60601 Recognition pending Voltage range Reflected ripple current 5.0 7.5 5.5 15 V mA p-p ・ ・3kVDC Isolation “Hi Pot Test” ISOLATION CHARACTERISTICS ・ ・Substrate Embedded Transformer Parameter Conditions Min. Typ. Max. Units Isolation voltage Resistance Flash tested for 1 second Viso= 1000VDC 3000 10 ・ ・Automated Manufacture ・ ・Industry Standard Footprint ・ ・Momentary Short Circuit Protection VDC GΩ GENERAL CHARACTERISTICS Parameter Conditions Switching frequency All output types Min. Typ. Max. 120 Units kHz OUTPUT CHARACTERISTICS PRODUCT OVERVIEW The NXE1 series is a new range of low cost, lower profile, fully automated manufacture surface mount DC/DC converters. The NXE1 series automated manufacturing process with substrate Embedded Transformer, offers increased product reliability and repeatability of performance in a halogen free, iLGA inspectable package. The NXE1 series, industry standard footprint is compatible with existing designs. Parameter Conditions Rated power Voltage set point accuracy Line regulation TA=-40° C to 85° C See tolerance envelope High VIN to low VIN Min. Typ. Max. Units 1.0 W 1.1 1.2 % /% Typ. Max. Units 85 125 ° C TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage Product temperature rise above ambient Cooling All output types -40 -50 All output types Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXE1S05 types For full details go to www.murata-ps.com/rohs w w w.m urata-p s.com 7V 1. Components are supplied in tape and reel packaging, please refer to package specification section. 2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load. C, nominal input voltage and rated output current unless otherwise specified. All specifications typical at TA= 25° All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 1 of 6 NXE1 Series Isolated 1W Single Output SM DC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’& ‘Isolation Test Voltage’are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXE1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NXE1 series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXE1 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. RoHS COMPLIANCE, MSL AND PSL INFORMATION This series is compatible with RoHS soldering systems and is also backward compatible with Sn/Pb soldering systems. The pin termination finish on this product series is Gold with nickel pre-plate. w w w.m urata-p s.com All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 2 of 6 NXE1 Series Isolated 1W Single Output SM DC/DC Converters TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. NXE1S0505MC Output Voltage 10% 5% 3% -4% 10 100 75 50 25 Output Load Current (% ) EFFICIENCY VS LOAD NXE1S0505MC 80 70 Efficiency (%) 60 50 40 NXE1S0505MC 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) TEMPERATURE DERATING GRAPH NXE1S0505MC Output Power (W) 1.5 1.0 0.5 0 -40 w w w.m urata-p s.com 85° C Safe Operating Area 100 50 0 Ambient Temperature (° C) 150 All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 3 of 6 NXE1 Series Isolated 1W Single Output SM DC/DC Converters APPLICATION NOTES Advisory Notes Minimum Load The NXE1 series is not hermetically sealed, customers should ensure that parts are fully dried before input power application. The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5% . The NXE1 has been tested to the following standards, which should not be exceeded for shock and vibration: BS EN 60068-2-64:2008 (Vibration Broadband Random) BS EN 60068-2-27:2009 (Mechanical Shock) Capacitive Loading & Start Up Typical start up times for this series, with a typical input voltage rise time of 2.2μ s and output capacitance of 10μ F, are shown in the table below. The product series will start into a capacitance of 47μ F with an increased start time, however, the maximum recommended output capacitance is 10μ F. Typical Start-Up Wave Form NXE1S0505MC Start-up time μ S 330 Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L L, μ H NXE1S0505MC w w w.m urata-p s.com Inductor SMD Through Hole Capacitor C, μ F Power Source DC C Load DC All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 4 of 6 NXE1 Series Isolated 1W Single Output SM DC/DC Converters PACKAGE SPECIFICATIONS Mechanical Dimensions Pin Connections 12.70 [0.500] (7.62 [0.300]) SMA PICKUP POINT Pin Function 1 3 7 8 14 -Vin +Vin -Vout + Vout NA NA - Not available for electrical connection. S 4.80 [0.189] MAX SEATING PLANE SMA PICKUP POINT 0.1 (0.004) S x5 PINS 2.54 [0.100] (TOP OF PCB) [ ] 3.40 0.134 2.80 0.110 1 3 7 7.37 [0.290] 10.41 [0.410] 14 8 7.62 [0.300] 2.54 [0.100] All dimensions in mm ±0.25mm (inches ±0.01). All pins on a 2.54 (0.1) pitch and within ±0.25 (0.01) of true position. Weight: 1 g Recommended Footprint Details 7.62 [0.300] x5 PLACES 2.30 [0.091] 9.40 [0.370] x5 PLACES 1.00 [0.039] 2.54 [0.100] w w w.m urata-p s.com All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 5 of 6 NXE1 Series Isolated 1W Single Output SM DC/DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS TAPE OUTLINE DIMENSIONS 22.3 [0.876] MIN [ ] 3°MAX Ø332 [13.071] MAX OR Ø180 [7.087] MAX Ø13.50 Ø 0.531 12.80 0.504 13.3 [0.525]# ] 0.6 0.024 MAX 0.3 0.012 ] 30.40 [1.197] MAX # DIRECTION OF UNREELING Ø1.5+-0.1 0.0 0.004 ] [Ø0.059 +-0.000 1.50 [0.059] MIN ## 16.0 [0.630] 11.0 [0.433]# Ø1.5 [Ø0.059] MIN 2.0 [0.079] 3°MAX Ø20.20 [Ø0.795] MIN 4.0 [0.157] COVER TAPE 1.75 [0.069] 11.5 [0.453] 24.0 [0.945] MAX 5.0 [0.197] REEL PACKAGING DETAILS LEADER SECTION 400 [15.748] MIN GOODS ENCLOSURE SECTION TRAILER SECTION 160 [6.299] MIN 100 [3.937] MIN Product Orientation Pin 1, located nearest to carrier drive sprocket. Reel Quantity: 7” - 420 13” -1000 Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED w w w.m urata-p s.com /sup p ort This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2014 Murata Power Solutions, Inc. All enquiries: www.murata-ps.com/support KDC_ NXE1.A01 Page 6 of 6 Murata Power Solutions社(MPS社)製品の取り扱い上の注意 1.製品の運搬時、電子部品等に力を加えたり、力が加わる様な作業をしないで下さい。 2.以下のような環境条件では絶縁劣化を引き起こす危険性がありますので、設置及び保管しないでください。 ・ 本仕様書の規格外の高温,高湿の保存や直射日光の当たるところ。 ・ 腐食性ガス雰囲気(Cl2、H2S、NH3、SO2、NOX等)。 ・ 水、油、有機溶剤等の液体がかかるところ。 ・ 塵埃の多いところ。 ・ その他、上記に準ずるところ。 3.低分子シロキサン(ジメチルポリシロキサン)含有率の高いシリコンゴム、シリコンボンド等の使用により、ボリウ ムやポテンショメータ摺動子やスイッチ類の接点の接触不良が発生する場合があります。低分子シロキサン含 有率は0.1%以下のものをご使用ください。 4.製品に使用されている個々の部品は、周囲温度により、その信頼性と寿命(MTBF)は極端に短くなります。当 データシートに定められている温度条件の範囲内で使用してください。 お願い 1. 本データシートは特に規定しない限り、電源単体での品質を規定するものです。ご使用に際しては御社製品 に実装された状態で必ず評価、確認をして下さい。 2. 当製品に万が一異常や不具合が生じた場合でも、2次災害防止の為に、完成品に適切なフェールセーフ機 能を必ず付加して下さい。 3. 当データシートに記載の製品について、その故障や誤動作が人命又は財産に危害を及ぼす恐れがある等の 理由により、高信頼性が要求される以下の用途でのご使用をご検討の場合、又は、当データシートに記載され た用途以外でのご使用をご検討の場合は、必ず事前に弊社営業部又は最寄りの営業所までご連絡下さい。 ①航空機器 ②宇宙機器 ③海底機器 ④発電所制御機器 ⑤防災/防犯機器 ⑥交通用信号機器 ⑦ 輸送機器(自動車、列車、船舶等) ⑧医療機器 ⑨情報処理機器 ⑩その他上記機器と同等の機器 4. 記載内容について、改良のため予告なく変更することや、供給を停止することがございますので、ご注文に際 してはご確認下さい。記載内容にご不明の点がございましたら、弊社営業部までお問い合わせ下さい。 5. 製品によっては、お守りいただかないと発煙、発火等に至る可能性のある定格や注意(保管・使用環境、定格 上の注意、実装上の注意、取扱上の注意)を記載しておりますので、必ずご覧下さい。 6. 当データシートに記載の製品の使用もしくは当データシートに記載の情報の使用に際して、当社もしくは第三 者の知的財産権その他の権利にかかわる問題が発生した場合は、当社はその責を負うものではありません。ま た、これらの権利の実施権の許諾を行うものではありません。 7. 当データシートの製品が、「外国為替及び外国貿易法」に定める規制貨物等に該当するものについては、輸 出する場合、同法に基づく輸出許可が必要です。 8. MPS 社の製造工程では、モントリオール議定書で規制されているオゾン層破壊物資(ODS)は一切使用しており ません。
© Copyright 2024 Paperzz