ZL-LTB16-24 16-Point Sensor Input Module Installation Instructions P1 P2 WARNING: We recommend installing up to a 4 Amp fast-blow fuse such as AGC4 or similar in series with the power supply as an extra safety measure. P4 P3 Power Groups Power Groups PLC Input Group 1 *For power requirements, see the Voltage Range listed in the PLC I/O chart below. Power* TB3 P1 1 P2 9 1 PLC Input Group 2 P1 19 9 18 10 P4 19 27 P1 P3 27 P3 TB1 3-wire DC Sensors PLC Input Group To PLC Common PLC Input Group To PLC Common To PLC Inputs To PLC Inputs P3 PLC Input Group 2 18 10 P2 P4 P4 24 1 PLC Input Group 1 P2 TB4 12 Cable Connector 13 Power* TB2 2-wire Sensors and Switches Typical Internal Circuit Sinking PLC Input Group Common Reference Point Sourcing PLC Input Group To PLC Inputs To PLC Common To PLC Inputs To PLC Common 10K Black Add External Jumper Black Common Reference Point Add External Jumper Common Reference Point Cable Connector Blue Blue P2, P4 Power (-) P2, P4 Power (-) Brown P1, P3 Power (+) Terminal Block Brown Internal Jumpers Add External Jumper Blue P2, P4 Power (-) Internal Jumpers Internal Jumpers NPN Sensor DL05/06 DL205 DL305 DL405 CLICK P3000 I/O Module Voltage Range Input Current Per Point (mA) D0-16ND3 D2-16ND3-2 D3-16NE3 D4-16ND2 D4-16ND2F D4-16NE3 C0-16ND3 C0-16NE3 P3-16ND3 20-28VDC 20-28VDC 4-30VAC/VDC 0.2-26.4VDC 10.2-26.4VDC 10.2-26.4VAC/ VDC 24VDC 24VAC/VDC 12-24VDC Internal Jumpers 2.52” [64.0mm] P1 P2 TB3 1 2 4mA @ 24VDC 6mA @ 24VDC 16mA @ 24VDC 3.8mA @ 12VDC, 8.3mA @ 24VDC 3.8mA @ 12VDC, 8.3mA @ 24VDC 3.8mA @ 12VAC/VDC, 8.3mA @ 24VAC/VDC 4mA @ 24VDC 3.4mA @ 24VAC/VDC 5mA @ 12VDC, 11mA @ 24VDC D1 D2 D3 1 13 D4 D5 D6 D7 0 1 2 1 R2 3 4 5 6 10 P2 P2 P2 P2 P2 P2 P2 P2 P2 9 9 7 1 C 10 11 12 13 14 15 16 17 10 18 18 P4 P4 P4 P4 P4 P4 P4 P4 P4 27 19 35nn DIN RAIL TB2 1 C P4 P3 2 D8 P1 D9 D10 D11 D12 D13 D14 D15 D16 TB1 3.42” [86.8mm] TB4 12 24 R1 27 P1 P1 P1 P1 P1 P1 P1 P1 P1 19 P3 P3 P3 P3 P3 P3 P3 P3 P3 Note: P3000 refers to the Productivity3000 line of Programmable Automation Controllers Specifications Description* Maximum Voltage UL Voltage Range** Nominal Current per Input Maximum Current per Input Maximum Current per Power Group (P1, P2, P3, or P4) Surrounding Temperature Range Approvals LED Indicator Circuit Terminal Block Contacts Wire Range (Rated Cross Section)** Wire Strip Length Screw Torque Connector Type Dimensions (WxHxD) Cable/Wire Clearance Mounting Restrictions Brown P1, P3 Power (+) Programmable Controller Comparison Table Family Blue Common Reference Point P2, P4 Power (-) P1, P3 Power (+) P1, P3 Power (+) PNP Sensor Brown Common Reference Point Add External Jumper 16-point, 24 volt Sensor Input Module with LEDS 50VAC/VDC (-10%/+20%) 0-30VAC/VDC (-10%/+20%) I/O module max. input current per point plus 2mA for LED indicator 500mA 4A 32 to 140°F (0 to 60°C) File # E200031 UL, cUL, Class 1, Division 2, Groups A,B,C,D Hazardous Locations, CE, EN 61131-2:2007 2mA @ 24VDC per LED Copper alloy, tin-lead plated 12-24AWG Solid or Stranded Copper Conductor (2.5mm²) 0.24-0.27” (6-7mm) 4.4 in-lbs (0.5 Nm) Molex Micro-Fit 3.0, 24 pin connector Example: Receptacle 43020-2400 Pins 43031 Series, Male 4.41” x 3.42” x 2.47” (112mm x 86.8mm x 62.8mm) 0.5 ” (12.7mm) Required None *Connecting cables are for internal wiring only. **Use Class 2 power supply. Use conductors rated 60°/75°C. 4.41” [112.0mm] 2.47” [62.8mm] Terminal Block Insertion Point Opening Dimension 0.098" [2.5 mm] 0.114" [2.9 mm] Pin and Terminal Assignments PLC Input Group 1 Connector Pin 1, 2, 13, 14 3 4 5 6 15 16 17 18 TB4 1(P2) 2(P1) Terminal 1 2 3 4 5 6 7 8 9 TB1 10 thru 18 19 thru 27 PLC Input Group 2 Connector Pin 7, 8, 19, 20 9 10 11 12 21 22 23 24 TB3 1(P3) 2(P4) Terminal 1 2 3 4 5 6 7 8 9 TB2 19 thru 27 10 thru 18 16-Point Sensor Input Module Installation Instructions Apply ZIPLink Labels (Supplied with the module) 1 Find correct label and remove from sheet PE UP Note: Upper designation R PE UP R PE UP R R PE UP PE UP ZL-LTB16-24 DIN Rail Installation and Removal To install ZIPLink module, insert upper tab into DIN rail. Note: For cable/wire clearance requirements see specifications. R R PE UP 2 Apply label to designated position Upper Click Rotate until firmly seated Choose I/O module type |C|1|2|3|4|5|6|7 and locked on DIN rail. To remove ZIPLink module, insert screwdriver between Tab 1 and module. Tab Pry up 1 to release clip from DIN rail. WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect.com® we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. 3505 Hutchinson Road, Cumming GA 30040 1-800-633-0405 www.automationdirect.com Copyright 2010, AutomationDirect.com Incorporated/All Rights Reserved Worldwide Tab 2 Repeat for Tab 2. ZIPLink Cable Removal 2 Pull connector from socket. 1 Push tab on raised tip and hold. HAZARD WARNING A. THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2/ZONE 2, GROUPS A, B, C AND D OR NON-HAZARDOUS LOCATIONS ONLY. B. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2/ZONE 2. C. WARNING – EXPLOSION HAZARD – DO NOT CONNECT OR DISCONNECT CONNECTORS OR OPERATE SWITCHES WHILE CIRCUIT IS LIVE UNLESS THE AREA IS KNOWN TO BE NON-HAZARDOUS. D. ALL MODULES USED WITH ACCESSORIES MUST USE R/C (ECBT2) MATING PLUG FOR ALL APPLICABLE MODELS. ALL MATING PLUGS SHALL HAVE SUITABLE RATINGS FOR DEVICE. 8/5/2010 Document # ZL-LTB16-24 Rev4
© Copyright 2026 Paperzz