a unique solution for home automation

Heating
Lighting and sockets
Number of independent zones
21
Number of switching circuits
32
Combination of various zone types
YES
Elements
Up to 4000 VA AC, 384 W DC
Controlled by schedules
YES
Control method
Relay 230V 16 A
Outside thermometer
1
Number of dimmer circuits
10
Outside temperature from the Internet
YES
Elements
According to input power, max 250 W
Weather forecast
YES
Control method
Dimmer
Adjustable hysteresis
YES
Number of LED dimmer circuits
10
Calibration of thermometers
YES
Elements
According to input power, max 250 W
Control of the heat source
YES
Control method
Dimmer
Heating modes
5
Number of RGB dimmer circuits
6
Elements
According to input power, max 250 W
Control method
Dimmer
Controlled by schedules
YES
Zone types (according to radiators used)
Hot-water radiator
Maximum number in one zone
1
Control method
Proportional servo-valve
Temperature measuring
Servo-valve built-in thermometer
Hot-water floor heating
Maximum number in one zone
4
Control method
Bistable thermal head
230 V or 24 V
Temperature measuring
Wall bus thermometer
Floor temperature monitoring
Floor temperature sensor
Electric convection heating
4
logy is not strictly given. The design should be the shortest and
connected to buses in individual rooms. The bus solution
Delayed switch off
YES
easiest possible. Elements are either connected directly to the
benefits from economic wiring and higher security due to the
Switching according to lighting intensity
YES
switchboard or to concealed boxes in rooms depending on what
fact that all elements are fed by safe low voltage.
Ventilation and heat recovery
Number of recuperation units
1
Control method 1
Paul, Nilan – fluent 2× 0 - 10 V DC
Control method 2
Others – three steps
with relay logic
Relay 230 V 16 A
Bypass control – cooling
YES
Wall thermometer
Anti-rime protection
YES
Control according to CO2 content
YES
Control according to air humidity
YES
Controlled by schedules
YES
Ventilation modes
5
Relay 230 V 16 A
Temperature measuring
Wall bus thermometer
Floor temperature monitoring
Floor temperature sensor
Security
Balanced PIR/Magnet inputs
16
Max PIRs per input
4
Max magnets per input
10
Number of zones
7
Zone types
Intruder, fire, meteo, technical
Tamper detection
YES
Inside/Outside siren
2
Keyboards with card readers
1
Accumulator backup
YES (the whole system)
GSM communicator
YES
Notification of events
SMS, e-mail
Shading
Number of blind or shutter circuits
16
Elements
Up to 4000 VA AC, 384 W DC
Slats tilting
YES
Reading the blind/shutter position
YES
Combining blinds and shutter
YES
Controlled by schedules
YES
Controlled according to outside temp.
YES
Controlled garage door
YES
Controlled entry gate
YES
Controlled according to lighting intensity
YES
Raising in strong wind
YES
Intelligent control switches
Number of switches
42
Number of switch buttons
4
Functions of switch buttons
Short & long pressing
Controlled elements
Lights, sockets, blinds, shutters
Mapping switch elements
Unlimited
letak-hh-a3-a4-08-13-EN.indd 1
servo heads, lighting and socket switches, dimmers) may be
Lighting modes
Temperature measuring
Control method
and action elements controlling the appliances (e.g. heating
8
Control method
Up 4000 VA AC, 384 W DC
HAIDY Home bus is of the CIB type and may be wired or wire-
Light scenes
Up to 4000 VA AC, 384 W DC
Elements
reading elements (e.g. switches, temperature and CO2 sensors)
less; a combination of both systems is also possible. Bus topo-
Elements
Electric floor heating
The HAIDY Home solution is a modular bus system. The
is more convenient in terms of installation. Both control and
A UNIQUE SOLUTION FOR
HOME AUTOMATION
Energy measurement
Measurement of el. power consumption
YES
Measurement of gas consumption
YES
Measurement of water consumption
YES
Measurement of el. power production
YES
Number of measured circuits
8
Combination of various meters
Unlimited
Statistical data
YES
Reaction to exceeded limits
8× relay control
Notification of exceeded limits
SMS, e-mail
Wireless elements
Number of switches
16
Number of controlled lights
16
Number of controlled radiators
10
Number of floor heating zones
10
Number of electric heating zones
10
Number of wireless thermometers
10
Used communication frequency
868 MHz
Maximum range within a building
30 m
SMS control
Heating control
YES
Lighting control
YES
Blind/Shutter control
YES
Security control
YES
Web interface
Number of simultaneously connected
devices
6
Recommended browsers
Mozilla Firefox, Chrome, Opera,
Safari, IE 8 and higher
Display weather forecast
YES
HAIDY a.s. | U Hellady 697/4 | 140 00 Praha 4 | Czech Republic
phone: +420 234 676 333 | fax: +420 234 676 120
email: [email protected] | www.haidyhome.cz
28.1.2014 14:31:16
Controlled heating
allows independent tem-
perature regulation in individual heating zones
(rooms). There are four heating zone types that you
can operate through HAIDY Home: hot-water radiators, hot-water floor heating, electric convectional
heating (convector heaters, electric radiators) and electric floor
HAIDY Home connects what
seemed to have been incompatible
– advanced functions, easy
control and low price.
heating (heating mats).
21
independent
hea-
ting zones; various zone
types may be combined
at random. Each heating
zone may include one
or more heating units.
• Economic heating control
The only exceptions are
• Comfortable lighting control
including dimming
the hot-water radiators
where each radiator is
• Electronic security equipment
with fire signalling
an independent heating
zone. A wall thermo-
• Safe control of sockets and appliances
• Central control of blinds and shutters
ximum utilisation of all provided elements. Due to the wireless
connection, the HAIDY Home solution may be used for new buil-
The wireless control may only be used to control individual
very useful and suitably complete the Departure mode. All lights
may also be operated. However, in such cases it is necessary to
elements. Equipment such as lights, sockets and electric ra-
according to their location, e.g. ground floor, attic and garage, or
may also be turned on or off from the homepage of the web con-
keep the heat recovery control unit, and HAIDY Home controls
diators require strong electric feeding. This solution therefore
trol interface.
the heat recovery through this control unit. The functions are
anticipates that the controlled appliances have their own electric
tectors, fire detectors, or in any other structure as the user wishes.
similar to those described above. The difference is that the
power supply which may then be controlled by the wireless
The zones may be set as permanently active, e.g. fire detectors or
ventilation intensity may not be continuously adjustable, but
switching element.
according to the detector type, e.g. windows security, motion de-
guarding valuable items and art. Each input may be temporarily
The control of blinds and shutters
is dealt with within the control of other shading
elements and drives, such as the garage door or
Five ventilation modes are available for heat recovery – Low,
Security alarm may be activated on the wall keyboard by
entry gates. Up to 16 independent circuits are
Standard, Comfort, Holiday and Vacation. The intensity of ven-
entering the code, by a contactless card, by a Departure button
available. Each circuit may be set by the user – if it
tilation for each mode may be set as you require. The modes
or from a web application. Security is always deactivated and the
operates the blinds, shutters, garage door or the gate. Each circuit
may then be activated either manually or automatically by me-
alarm status cancelled by the magnetic card or by the code ente-
may then be assigned one or more switches to control it. It also
ans of schedules. The day schedule may include up to six time
red on the keyboard or in the web application. Security activation
works the other way round – one switch may be assigned more
intervals to which you can assign one of the Low, Standard or
may be interlinked with the Departure mode when, after entering
than one blind circuit; any combination is possible. Up to 42 swit-
Comfort modes. Vacation applies to the whole day and is suitable
the code, the house is set to a Low, lights and defined sockets are
ches may be used not only to control the blinds and shutters but
especially for long-term absences. The special Holiday mode
switched off and automatic pull-down of blinds may be activated.
also the lights or sockets.
sets the Sunday program for the day for which it is set and
Control of lights and sockets
allows the use of all lamps, including their
Pulling up and down is controlled for blinds; for shutters the system moreover controls the tilting of slats. Due to the fact that the
multi-functional switches are equipped with four buttons that
the energy inlet to the house and by important
actual temperature in the
well as up-to-date LED and RGB may be opera-
it is very easy to use one
zone (room). In the case
ted. Sockets may also be controlled, including their dimming. Up
switch to control, for
boiler. Measuring may occur at up to 8 places.
of electric floor heating,
to 42 independent circuits are available. For each of the circuits
example, the blind and
The system allows the measuring of both consumption and
the heat may also be controlled by the temperature within the
the user may define whether it is a socket or a light one. Each cir-
light in one room.
generation, and so may be used to monitor the photovoltaic system,
floor structure, which is especially useful for floors with coverings
cuit may be assigned one or more switches to control the circuit.
that shall not be exposed to high temperatures.
It also works the other way round – one switch may be assigned
Just like the heating, the
more than one light circuit; any combination is possible. Up to 42
blinds and shutters may
for example.
Standard, Comfort, Holiday and Vacation. Temperatures for each
also to lower and raise the blinds and shutters.
schedules, which is use-
whole
system
may
be
controlled
both
manually
and automatically. Manual operation is possible either by wall-installed switches or through a computer, tablet or mobile phone. Automatic control is provided
either by schedules or upon
inputs from sensors.
Price
HAIDY Home is so variable and modular that anyone
can choose exactly the configuration that suits them
the best. End user cost for
a three bedroom house
is about 4700 EUR.
Customer
investment
in
such system will return
through
ful for shading at certain
mode and each zone may be set as you require. The modes may
energy
savings
then be activated either manually or automatically by means of
8 light scenes may be used, where a scene is a common setting
pre-defined
schedules. The day schedule may include up to six time intervals
for any required group of lights. The lights may also be con-
example, or to simulate
for which you can assign one of the Low, Standard or Comfort
trolled upon the intensity of lighting (the light turns on if the
somebody‘s
modes. Vacation applies to the whole day and is suitable espe-
lighting intensity drops
Blinds and shutters may
cially for long-term absences. The special Holiday mode sets the
below a certain level,
also be controlled ac-
Sunday program for the day for which it is set and is used as an
e.g. at dusk). Lights may
cording to outside light
exception to regular schedules. Czech public holidays are predefi-
be switched on just for
intensity or the outside
ned and activated automatically; four others may be set by user.
a period of time which
temperature. The shutters may be pulled up in the case of strong
is suitable to illuminate
wind. The raising or lowering of all blinds may also be managed
the staircases and corri-
directly from the homepage of the web control application or by
dors where the light may
any switch to which the function is assigned.
Security alarm
safeguards the house or flat
against not only intruders but also fire. PIR motion
detectors and magnetic contacts in windows and
doors are able to detect forced entry to the building; smoke and increased temperature sensors
warn of the fire hazard. The control unit is backed up by an
accumulator therefore the system stays active even during
a power failure. An inside or outside siren sounds the alarm. Each
event is saved in the history and important events are notified
by SMS or email. Communication with Alarm Receiving Centre is
also supported.
times,
for
presence.
turn off after, for example 5 minutes. Lights and
sockets – just like the
le in several design and colour variants. Each switch is equipped
with four buttons and each of the buttons distinguishes between
Here is a setting example for a four-button switch controlling
lights and shutters: left pair of buttons controls the light; pressing
the top left button turns the light on, pressing the bottom left
button turns the light off; a long press on the top right button
lifts the shutter, a long press on the bottom right button lowers
the shutter; a short press on one of the right buttons stops the
used for statistical ana-
shutter motion and tilts the slats to one side or other.
lysis and information on
consumption, but also
for reactions to defined
events. If a defined energy consumption level is
exceeded, an action may
be taken. For example, if
the defined water consumption is significantly exceeded, the water
inlet may be stopped;
or if the photovoltaic
system provides sufficient output, a specified
appliance may be swit-
Ventilation and heat recovery control
ched on. The events may
also be notified by SMS or email.
heating – may be contro-
offers advanced intelligent heat recovery control con-
lled by schedules, which
trol. For some types of heat recovery, HAIDY Home
allow, for example, a
is able to fully replace the heat recovery control con-
simulation of somebo-
trol unit. The customer therefore does not have to
HAIDY Home wherever it is not possible to use
dy‘s presence, outdoor
acquire the control unit from the heat recovery manufacturer. This
cabling. It may be in the case of previously finished
lighting or disconnection
applies to Paul or Nilan heat recovery systems, for example. Moreo-
buildings or places where the cabling cannot be
installed for technical reasons (e.g. switches on
The wireless solution
allows the use of
of certain socket circuits
ject to the configuration
The system offers 16 independent circuits to connect PIRs or
in defined times. The schedule provides six time intervals for each
rol or ventilation based on CO2 content or humidity. Another benefit
glass partitions). Wireless operation may be provided for mul-
and operating conditions.
magnetic contacts. Up to 10 magnetic contacts and 4 PIR moti-
day. One of three light modes – On, Off and Control according to
is the possibility to easily switch heat recovery to a cooling mode or
ti-functional switches, the switching of lights and sockets and
on detectors may be connected to each circuit, which also allows
light intensity - may then be selected for each of the intervals.
to activate the anti-rime protection.
for all types of heating zones.
letak-hh-a3-a4-08-13-EN.indd 2
ches follows that of traditional switches. The switches are availab-
Measurements may be
ver, HAIDY Home adds functions such as automatic schedule cont-
in about 3-6 years, sub-
through multi-functional wall switches. The design of these swit-
and logically arranged.
long and short pressing,
Control
elements and provides all required settings.
Lighting, sockets, blinds and shutters may also be controlled
rol elements is significantly reduced; the control is very intuitive
onal bulb lights, fluorescent or halogen lamps as
also be controlled by
or mobile phone, allows control of all system
and blinds or shutters. That way, the number of necessary cont-
zone
the
application, accessible from a computer, tablet
measure electricity, water and
can distinguish between
measuring
offer several ways
to control individual appliances. The software
rol several lights in one room or to combine the control of lights
dimming. The lamps may be of any type – traditi-
switches may be used not only to control the lights or sockets but
The
Energy meters
The control elements
long and short presses. Such a switch is typically used to cont-
meter is located in each
Five heating modes are available for each heating zone – Low,
operated by anyone who is able to use a mobile phone.
is used as an exception to regular schedules.
gas consumption. They are usually situated at
dings and reconstructions as well as for older houses and flats.
Control of HAIDY Home is so easy and intuitive it can be
runs in levels defined by the heat recovery control unit.
appliances such as the heat pump or electric
• Intelligent ventilation
and recuperation control
The functions may be mutually interconnected to ensure ma-
heat recovery units controlled by other methods, such as Atrea,
put out of operation by means of the bypass function.
There may be up to
HAIDY Home solution offers:
Group functions that enable the switching off of all lights are also
one or more of the 6 security zones. The zones may be divided
tamper detection. Individual inputs may be freely assigned to