Setting Guide ver. 1.00 CONTENT 1. Set up 1.1 Initialize 1.2 Smart Monitor Installation 1.3 Smart Monitor Functions SET-UP 2. Measure 2.1 General setting Paper / Plastic / Non-shiny Metal GENERAL 2.2 Black (dark color) material Rubber / Paint BLACK 2.3 Shiny material Mirror / Shiny Metal SHINY 2.4 Half clear material PCB / Glue HALF CLEAR 3.1 Multi-Task Mode MULTI TASK 3.2 Communication by Hyper Terminal HYPER TERMINAL 3.3 ZS-MDC / ZS-DSU MDC DSU 3. Special CLEAR 2.5 Clear material Glass / Liquid SET-UP GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 1. SET UP SET-UP SET- 1.1 Initialize By Smart Monitor GENERAL (1) (2) BLACK SHINY (3) HALF CLEAR By Controller CLEAR MULTI TASK (1) Change FUN MODE (2) Push “right” button (3) Push “3” button (4) Push “2” button (5) Push “1” button (6) Push “1” button HYPER TERMINAL MDC DSU 1 SET-UP SET- 1.2 Smart Monitor Installation Software install to PC GENERAL (1) Double click “setup.exe” -> Installer starts BLACK SHINY HALF CLEAR CLEAR (2) Check “Accept” MULTI TASK HYPER TERMINAL MDC DSU 2 (3) You can change install folder (Please remember the folder location! ) USB driver installation (2) Windows will find new hardware GENERAL (1) Connect ZS to the PC with USB SET-UP SET- 1.2 Smart Monitor Installation BLACK (3) Select “Assign by user” SHINY HALF CLEAR MDC DSU * Sometimes not happen HYPER TERMINAL (7) Wait few second then you see “new hardware found” again! * MULTI TASK (5) Select “usb” folder in “SmartMonitor ZS3” (6) Finish installing USB driver. CLEAR (4) Check “Assign folder” (8) Do the same process from 3 to 6. 3 SET-UP SET- 1.2 Smart Monitor Installation Trouble shooting (1) Check COM port Number GENERAL (1) Right click at my computer (2) Choose “Property” BLACK SHINY (3) HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 4 (5) (4) (3) Click Hardware TAB (4) Click “Device Manager” (5) Check COM port number Trouble shooting (2) Smart Monitor shows “Error” (2) Right click at the “SpecialCharacter.ini” BLACK (3) Select “Property” GENERAL (1) Go to Smart Monitor installed folder SET-UP SET- 1.2 Smart Monitor Installation SHINY HALF CLEAR CLEAR (4) Remove “Read-only” check (7) Save file HYPER TERMINAL (6) Re-write as following MULTI TASK (5) Open “SpecialCharacter.ini” file MDC DSU 5 SET-UP SET- 1.2 Smart Monitor Installation Trouble shooting (3) Manual USB driver installation GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 6 (1) Go to Smart Monitor installed folder (2) See “usb” folder (3) Run “setup.exe” SET-UP SET- 1.3 Smart Monitor Functions Graph GENERAL BLACK (3) (5) (1) SHINY HALF CLEAR (4) (2) CLEAR (2) Check “plot” mark (4) Push “Auto-scale” HYPER TERMINAL (3) Push “START” and then push “STOP” soon MULTI TASK (1) Push “Graph edit” button (5) Push “START” again MDC DSU * It is not possible to change setting in plotting process 7 SET-UP SET- 1.3 Smart Monitor Functions Logging (simple logging setting) GENERAL BLACK (2) (1) SHINY (3) HALF CLEAR (4) (5) CLEAR (1) Start trigger setting “None” (2) End trigger setting “None” MULTI TASK HYPER TERMINAL MDC DSU 8 (3) Sampling interval “100ms” (4) Elapsed time “20s” or more (5) Push “Standby” and start logging 2. MEASURE BLACK *To set Regular position: Set the angle which LD-Power becomes minimum. GENERAL Regular Reflection Type : Regular Diffuse Reflection Type : Diffuse ( normal ) : Regular ( glass, mirror, shiny ) SET-UP 2.1 General Setting SHINY HALF CLEAR CLEAR *Be careful with the head direction MULTI TASK HYPER TERMINAL MDC DSU 9 SET-UP Controller Setting Change for customers request ( speed, resolution ) GENERAL Sampling time Hi-speed standard Hi-reso 110us 500us 2ms Hi-sens 4ms BLACK Check the “measurement cycle”(sampling time) SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 10 If LD-power is always 80%, you should change Measurement Mode. Set the sensor head setting To measure actual value, PLEASE DO SCALING ! e.g. 2 point scaling 2. Push scaling button GENERAL 1. Function settings SET-UP Scaling BLACK SHINY HALF CLEAR 3. Choose “Actual Scaling” MULTI TASK Enter real value ( point 2 ) CLEAR Enter real value ( point 1 ) 4. Push scaling HYPER TERMINAL MDC DSU 11 SET-UP GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 12 2.2 Black material SET-UP Sensor Head Setting Regular Reflection Type : Regular Diffuse Reflection Type : Diffuse GENERAL Controller Setting BLACK Change for customers request ( speed, resolution ) If customer doesn’t care sampling speed, set “Hi-sens”. SHINY HALF CLEAR Set the sensor head setting CLEAR MULTI TASK HYPER TERMINAL MDC DSU 13 Trouble shooting SET-UP CASE : “Incident Level 0”,”LD power 80%” GENERAL 1. Change “Sensor Head Setting” to Regular to get more incident level. *To set Regular position: Set the angle which LD-Power becomes minimum. BLACK 2. Change “Gain Setting” to bigger. *”incident gain setting” Bigger value causes worse resolution. SHINY HALF CLEAR Set the sensor head setting CLEAR MULTI TASK HYPER TERMINAL MDC DSU 14 Increase the Gain Setting value until LD power is lower than 80%. 1(small) to 5(high gain) 2.3 Shiny material Set the angle which LD-Power becomes minimum. Change for customers request ( speed, resolution ) BLACK Controller Setting GENERAL Sensor Head setting is very important at MIRROR ! Please set exact position. Regular Reflection Type : Regular Diffuse Reflection Type : Regular *To set Regular position : SET-UP Sensor Head Setting SHINY CLEAR Change to “Mirror” HALF CLEAR Set the sensor head setting MULTI TASK HYPER TERMINAL MDC DSU 15 Trouble shooting SET-UP CASE : “ERROR” ( 2 peaks on the area ) GENERAL 1. Set “Measure Area” Or change “Measuring Object” to GLASS. *ZS can measure “some peaks” only GLASS mode. ERROR BLACK SHINY HALF CLEAR CLEAR 2 peaks MULTI TASK (2) HYPER TERMINAL MDC DSU 16 (1) (3) Set Measure Area 2.4 Half clear material SET-UP Sensor Head Setting Regular Reflection Type : Regular Diffuse Reflection Type : Diffuse GENERAL Controller Setting BLACK Change for customers request ( speed, resolution ) SHINY CLEAR Change to “PCB” HALF CLEAR Set the sensor head setting MULTI TASK HYPER TERMINAL MDC DSU 17 Trouble shooting SET-UP CASE1 : “Incident Level 0”,”LD power 80%” GENERAL 1. Change “Sensor Head Setting” to Regular to get more incident level. *To set Regular position : Set the angle which LD-Power becomes minimum. BLACK 2. Change “Gain Setting” to bigger. *”incident gain setting” Bigger value causes worse resolution. SHINY HALF CLEAR Set the sensor head setting CLEAR MULTI TASK HYPER TERMINAL MDC DSU 18 Increase the Gain Setting value until LD power is lower than 80%. 1(small) to 5(high gain) Trouble shooting 1. Set “Measure Area”. *ZS can measure “some peaks” only GLASS mode. GENERAL ERROR SET-UP CASE2 : “ERROR” ( 2 peaks on the area ) BLACK SHINY HALF CLEAR CLEAR 2 peaks MULTI TASK (2) HYPER TERMINAL (3) Set Measure Area MDC DSU (1) 19 Trouble shooting SET-UP CASE3 : Strange Value ( during peaks ) 1. Set “Measure Area”. *ZS assumes continuous peaks as 1 peak. So, measuring value is calculated as the center of the peak. GENERAL BLACK SHINY HALF CLEAR CLEAR During peaks MULTI TASK (2) HYPER TERMINAL MDC DSU 20 (1) (3) Set Measure Area 2.5 Clear material Set the angle which LD-Power Controller Setting GENERAL Sensor Head setting is very important at GLASS ! Please set exact position. Regular Reflection Type : Regular Diffuse Reflection Type : Regular *To set Regular position : SET-UP Sensor Head Setting becomes minimum. BLACK Change for customers request ( speed, resolution ) SHINY CLEAR Change to “Glass” Or “Glass Thickness” Or “Glass Gap” HALF CLEAR Set the sensor head setting MULTI TASK HYPER TERMINAL MDC DSU 21 Trouble shooting SET-UP “GLASS” CASE1 : Reflection level of first surface is too small GENERAL 1. Change “Adjustment … incident level” to the “First surface” *ZS controls LD-power to stable seeing “peak of all incident level” as default setting. BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 22 Change settings Trouble shooting SET-UP “GLASS” CASE2 : To measure another surface GENERAL 1. Change “Measure Area” e.g. to measure 2nd peak BLACK SHINY HALF CLEAR CLEAR MULTI TASK (2) HYPER TERMINAL (3) Set Measure Area MDC DSU (1) 23 Trouble shooting SET-UP “GLASS” CASE3 : LD-Power is not stable 1. Change “Laser Intensity” to “Fixed”. GENERAL 2. Write “Emitted Light Amount” to stabilize Incident Level. *target “Incident Level” 1000 (If Hi-speed, 280) BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 24 Change settings White value Trouble shooting GENERAL 1. Do “Scaling”. *ZS needs to do “scaling” because it doesn’t know the transmittance of glass. SET-UP “GLASS THICKNESS” “GLASS GAP” CASE1 : Strange Value ( too small, too big ) e.g. 2 point scaling 2. Push scaling button BLACK 1. Function settings SHINY HALF CLEAR CLEAR 3. Choose “Actual Scaling” 4. Push scaling MULTI TASK Enter real value ( point 2 ) HYPER TERMINAL Enter real value ( point 1 ) MDC DSU 25 Trouble shooting SET-UP “GLASS THICKNESS” “GLASS GAP” CASE2 : Too thin to measure. GENERAL 1. Change “Back ground level before add” *This value means changing ground level. BLACK SHINY HALF CLEAR 60 CLEAR MULTI TASK HYPER TERMINAL MDC DSU 26 Set value 110 = 50(default) + 60 Trouble shooting SET-UP “GLASS THICKNESS” “GLASS GAP” CASE3 : 2nd Reflection is too small Method1. Change reference peak to “second surface”. GENERAL BLACK SHINY HALF CLEAR CLEAR Method2. Change to “fixed” LD-power and set bigger LD-power. MULTI TASK HYPER TERMINAL MDC DSU 27 SET-UP Method3. 2 area measurement : * 2nd area’s LD-power is automatically changed GENERAL 1. Change these setting as following ( You can choose “Glass Thickness” or “Glass Gap” BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 28 2. Check box ON 7. Check box OFF 3. Push “Area Teach” 5. Set “Start and End pos.” 6. Push “set measure Area” 4. Set area only to 2nd peak 3. SPECIAL SET-UP 3.1 Multi-Task mode Controller Setting GENERAL BLACK SHINY HALF CLEAR Multi-Task mode “ON” CLEAR MULTI TASK HYPER TERMINAL MDC DSU 29 SET-UP GENERAL Task1 : Peak Task2 : Bottom BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 30 Peak Bottom Task3 : Calculation “Task1 – Task2” = STEP 3.2 Communication by Hyper Terminal BLACK Change COM setting to “NORMAL” at Function mode. FUN mode > system > com > mode GENERAL ZS pre-setting (ZS-H doesn’t need to be set) SET-UP * We don’t use “Compoway/F protocol” * We use HyperTerminal as example * Please use “capital character” ( not “m” but “M”) SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 31 Hyper Terminal Setting SET-UP GENERAL (1) Change ZS to RUN mode (2) Connect ZS to PC with USB cable (3) Boot Hyper Terminal (4) Name any name BLACK SHINY HALF CLEAR (5) Change COM setting to certain number CLEAR MULTI TASK HYPER TERMINAL MDC DSU 32 This number depends on the PC (6) Set these value SET-UP 8 GENERAL 38400 **(default setting) None BLACK 1 None SHINY HALF CLEAR CLEAR ** ONLY need to set for RS-232C connection. You can change speed MAX 115200 bps. This case you have to change controller setting also. MULTI TASK HYPER TERMINAL MDC DSU 33 (7) Change property SET-UP GENERAL Property BLACK SHINY HALF CLEAR CLEAR Check these 3 marks MULTI TASK HYPER TERMINAL MDC DSU 34 File ASCII setup SET-UP (8) Try to type “M(return)”. so you will get measurement value. GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 35 Command Explanation SET-UP These are some of important commands. M : get measurement data DATAGET : get setting information DATASET : set setting information GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 36 These are some of important parameters. Command Examples MDC CH1 LDC CH2 LDC CH3 LDC CH4 SET-UP CH0 LDC GENERAL ** CH information comes after “Data.No” or “Task.No” BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL (1) Get measurement value from CH0 Task1 M00 (2) Get measurement value from CH2 Task2 M12 (3) Get measurement value from CH4 Task4 M34 (4) Check CH0 measurement mode DATAGET 0 0 0 (5) Check CH1 measurement mode DATAGET 0 0 1 (6) Change CH3 measurement mode to Hi-Speed DATASET 0 0 2 3 ( It takes around 10sec) (7) Check CH4 Average number DATAGET 43 2 4 (8) Change CH1 Average number to 4096 DATASET 43 2 12 1 MDC DSU 37 SET-UP GENERAL BLACK SHINY HALF CLEAR CLEAR MULTI TASK HYPER TERMINAL MDC DSU 38 3.3 ZS-MDC / ZS-DSU Case 1 : Thickness measurement SET-UP ZS-MDC GENERAL BLACK MDC LDC LDC 0CH 1CH 2CH SHINY HALF CLEAR Set input data. CLEAR MULTI TASK MDC DSU Set reference thickness. HYPER TERMINAL Set ”Calculation”, “Thickness”, parameters 39 SET-UP ZS-MDC Case 2 : gap measurement GENERAL BLACK MDC LDC LDC 0CH 1CH 2CH SHINY HALF CLEAR Set input data. CLEAR MULTI TASK HYPER TERMINAL MDC DSU 40 Set ”Calculation”, “Step”, parameters *We can’t use Smart monitor ZERO for ZS-DSU. GENERAL BLACK -SETTING ORDER EXAMPLE 1. SOURCE 2. START TRIGGER 3. END TRIGGER 4. SAMPLE (sampling) > LOGGING ! SET-UP ZS-DSU SHINY HALF CLEAR -To use log data 1 ( CF card > PC ) 1. Remove CF memory card and get data 2. Use CSVconverter 3. Open csv file CLEAR MULTI TASK -To use log data 2 ( USB ) Send compoway/F command to a controller HYPER TERMINAL MDC DSU 41
© Copyright 2026 Paperzz