Type PC1 Load Cell Lastcell PC1

FLINTEC
...the right weigh
Lastcell PC1
Type PC1 Load Cell
En produkt från Flintec
IP 67
Flintec load cells are designed to meet the most stringent
accuracy requirements. Certifications have been obtained
from Weights & Measures Authorities, worldwide.
The PC1 platform load cells are available in the capacities 6 kg
to 200 kg and include Accuracy Classifications GP, C3, C3 MI 6
and C4 according to OIML R 60; NTEP nmax=4500.
They offer stainless steel construction and improved potting,
making them suitable for use in tough industrial environments.
Designed to withstand shock and fatigue loading.
The off center load performance according OIML allows a
maximum platform size of 600 x 600 mm.
The version PC1B is available with M10 thread in the capacities
50 kg, 75 kg and 100 kg.
The PC1 / PC1B is available for use in hazardous areas zone
1, 2 (gas) and 21, 22 (dust) according to EEx ia IIC T6...T4
T150°C ATEX.
www.flintab.se
Kabelvägen 4 • 553 02 Jönköping
E 23
Tfn 036-31 42 00 • Fax 036-18 50 79
07/03
1/2 [email protected]
www.flintec.net
APPROVED
Important Features
• Capacity: 6 kg to 200 kg.
• High accuracy.
• Stainless steel construction.
• Protection IP 67 (IP 54 for 6 kg and 10 kg).
• Maximum platform size 600 x 600 mm.
• Integral mounting spacer.
• W&M certified for 4000 intervals.
• Factory mutual approved.
Option
• Explosion protection zone 1, 2, 21 and 22
ATEX.
Lastcell PC1
FLINTEC
...the right weigh
Maximum capacity (=Emax)
Rated Output (=RO)
Accuracy class according to OIML R 60
Maximum number of verification intervals (n)
Minimum load cell verification interval (vmin)
Combined error
Creep error (30 minutes) / DR
Temperature effect on minimum dead load output
Temperature effect on sensitivity
Excitation voltage
Zero balance
Input resistance
Output resistance
Insulation resistance (100 V DC)
Compensated temperature range
Operating temperature range
Safe load limit
Ultimate load
Safe side load
Maximum platform size; loading according OIML
Maximum off center distance at maximum capacity
Load cell material
Sealing
Protection according DIN 40.050
kg
mV/V
%RO
%RO
%RO/°C
%/°C
V
%RO
M
°C
°C
%Emax
%Emax
%Emax
mm
mm
6 / 10 / 15 / 30 / 50 / 75 / 100 / 200
6 / 10 / 15 / 30
2 ± 5%
(GP)
C3
C3 MI 6
C4
n.a.
3000
3000
4000
n.a.
Emax/8000
Emax/8000
Emax/8000
± 0.040
± 0.015
± 0.012
± 0.012
± 0.060
± 0.016
± 0.008
± 0.012
± 0.0040
± 0.00085
± 0.00085
± 0.00085
± 0.0020
± 0.0010
± 0.0010
± 0.0008
5...15
±1.0
390 ± 10
330 ± 25
5000
–10...+40
–20...+65
200
300
100
375x375 for 6...15 kg / 450x450 for 30 kg / 600x600 for other capacities
200
stainless steel 17-4 PH (1.4548)
potted
IP 67 **
** Attention: Maximum capacity 6 kg and 10 kg only available with protection IP 54
Dimensions
150
32
19
40
1.5
6
19
10
100
19
M6* (4x)
25
6...100 kg
38 25.4
All dimensions in mm. Dimensions and specifications are subject to change without notice.
PC1:
Mounting bolts M6 8.8; torque 10 Nm. Torque value assumes oiled threads.
* Unified thread 1/4-20 UNC is available.
PC1B: Mounting bolts M10 8.8; torque 50 Nm (50/75/100 kg). Torque value assumes oiled threads.
E 23
07/03
2/2
Wiring
• The load cell is provided with a shielded,
4 conductor cable (AWG 24).
• Cable length:
3 m.
• Cable diameter: 5 mm.
• The shield is connected to the load cell body.
+ Input
(green)
+ Output
(white)
– Input
(black)
– Output
(red)
Shield
(yellow)
2004-04-05
200 kg
Vi förbehåller oss rätten att ändra tekniska och/eller kommersiella
delar av detta dokument utan föregående avisering.
M6* (8x)
Flintab AB
www.flintec.net
Distriktskontor:
Kabelvägen Huvudkontor:
4 553 02 JÖNKÖPING
Tel 036-31 42 00 www.flintab.se
[email protected]
Flintab AB, Kabelvägen 4 • 553 02 Jönköping
Tfn 036-31 42 00 • Fax 036-18 50 79
www.flintab.se • [email protected]
MALMÖ
ESKILSTUNA
SUNDSVALL
040 - 18 10 30
016 - 13 76 20
060 - 58 05 20
GÖTEBORG 031 - 48 00 25
STOCKHOLM 016 - 13 76 20
Utgåva 2013-04-22. Mått i mm där ej annat anges. Vi förbehåller oss rätten att ändra tekniska och/eller kommersiella delar av detta dokument utan föregående avisering.
PC1 Specifications