Greening - the full lifecycle Going the extra mile Low Carbon ICT Conference at Oxford University’s Saїd Business School Oxford, 19th March 2008 Juergen Heidegger 1 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved 2 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved The challenge Steadily growing quantities of scrap IT EU legislation: WEEE and RoHS Energy prices increasing Infrastructure costs for powering and cooling data centers are rising faster than the procurement costs for new servers Customer expectations: Environmentally harmless production Environmentally conscious products Without additional expense Data Center Energy Efficiency and Productivity, The Uptime Institute, 2007 3 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Integrated approach to environmental protection Customer Recycling & disposal Employees Production Competence Responsibility Development Supplier Product use Legal requirements ISO 14001-certified environmental management system includes all employees and suppliers. 4 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Where we invent and build – Excellent quality made in Europe Environmentally conscious production and logistics Input most modern Europe's manufacturing facilities for PCs and servers Output Customizing and Manufactured-to-order products components, materials Inbound logistics and sourcing Reduced packaging Sea freight when possible 5 Supplier selection, contracts, audits, information, … Jürgen Heidegger Green IT Production Outbound logistics Saving energy and water Optimal packaging Reducing hazardous materials, waste, wastewater and emissions Direct shipments to customers In-house mainboard development and production Bulk-packaging for large accounts Lead-free soldering (years before RoHS) © Fujitsu Siemens Computers 2008 All rights reserved Installation “once-for-many“ Build Management Customization Services Client System OS Module HDD Driver Module Fujitsu Siemens Computer Factory Customer Module 6 Jürgen Heidegger Green IT Onsite Installation Customer Applications Operating System Drivers © Fujitsu Siemens Computers 2008 All rights reserved Customer LAN Distribution From Engineering to production: just a 3 minute-walk Volume production Test center Server production Systemboard production Product Management R&D Warehouse Consignment Stock 7 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 Mass Customization All rights reserved Boost Energy Efficiency Energy-efficient Business Clients Maximize Battery Life ECO Button PC running 8 hours / day Avoid unnecessary power consumption with an integrated ECO Button to maximize battery life (LIFEBOOK P7230). Power Management Integration Reduce energy consumption by ~15 percent with integrated Power Management (LIFEBOOK S6410). Display Switched Monitor Outlet off by the system unit resulting in reduced energy consumption through the switched monitor outlet (ESPRIMO E5925). Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 CO2 Emissionen kg/a 120 90 Display is powered through and switched 8 Up to 50% CO2 savings achievable All rights reserved 60 30 0 Standard PC Green PC* Green PC/PM* •Green PC: ESPRIMO E5615 •PM = Power Management Worlds first green PC for consumers Very low energy consumption, in all modes 80W in active mode, ~27% less* 50W in idle mode, ~20% less* 3,5W in energy saving mode Halogen free mainboard Very low noise emission Below 30 db Environmentally conscious packaging Fully recyclable Fujitsu Siemens Computers green power management … and Zero Watt standby display * compared to a standard PC 9 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved SCALEO Li 2405 green edition Data Center and Infrastructure Complexity Explosion of Servers & Applications Web Architecture Total number of servers installed increased by factor 100 in one decade Number of servers/processors per rack increased by factor 10 in ten years Client/Server Mainframe Power and thermal waste per server increased by factor 5 in ten years Future single cabinet is 20 kW = 3 fireplaces A few big servers 10 Jürgen Heidegger Servers begin to proliferate Green IT More servers More applications More users © Fujitsu Siemens Computers 2008 All rights reserved 1m² of floor space = 20 households in a year How to cope with the Green IT challenges? Boost Energy Efficiency in IT Infrastructures Increase use of energy efficient components Reduce consumption through efficient systems Usage of cooling optimized systems Optimize Infrastructures Consolidation Virtualization Automation Transition from a static to a dynamic IT environment Optimize Data Management Information Lifecycle Management Boost Energy Efficiency in Cooling Infrastructures Management of cooling airflow in racks / data centers 11 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Increase use of energy efficient components Power optimized server PRIMERGY RX300 S3 Distribution of power consumption 14% Fan 12% PSU 22% PSU 33% Energy saved 11% MoBo 14% CPU 8% Memory 23% CPU 18% HDD 14% Fan 11% Memory 11% MoBo 7% HDD Standard system: (SPECint_rate_base 148) Energy optimized system: (SPECint_rate_base 148) E5335 CPU, 8x 1GB RAM, 6x HDD 3,5“ 15K L5335 CPU, 4x 2GB RAM, 6x HDD 2,5“ 10K Using different components results in reduced energy and cooling costs. 12 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Reduce energy consumption through efficient systems TX120 - The most energy efficient server Lowest energy consumption 163 Watts active power fully equipped Latest Dual-Core Intel® Xeon® UP processor 3070/3040 Hot-plug 2.5-inch SAS HDD Further power reduction possible (Celeron® processor with 35W) Lowest noise 28 decibels (dB) in idle mode 31 decibels (dB) in operation Smallest footprint Compact chassis: 99 x 340 x 399 mm (WxHxD) Tower server A real server Raid1 & hot-plug HDD, ECC memory, Server processor, Server Operating System, full Server Management 13 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved How to cope with the Green IT challenges? Boost Energy Efficiency in IT Infrastructures Increase use of energy efficient components Reduce consumption through efficient systems Usage of cooling optimized systems Optimize Infrastructures Consolidation Virtualization Automation Transition from a static to a dynamic IT environment Optimize Data Management Information Lifecycle Management Boost Energy Efficiency in Cooling Infrastructures Management of cooling airflow in racks / data centers 14 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Virtualization A Perfect Combination: Blades & Virtual Machines Gupta DB 2 Proxy 100% 50% 0% 50% 0 100% % 15 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Exchange 2003 Linux NT Domain DHCP WebEx Web Oracle Sphere Active NT App Directory Server Siebel Lotus Notes W2K App Automation Monitoring and controlling server power ServerView power management Power monitoring Power control On / off Restart Power consumption control Best performance Lowest power 16 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Service-oriented Infrastructure – energy efficient consumption ISV SOA Platform Service 1 Service 2 Service 3 SOA Service Management Dynamic Resource Management Compute Pool Storage Pool Network services Dynamic Data Center 17 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Integrated Integrated Service Level Management Transition from a static to a dynamic IT environment Flexible Energy Consumption through Dynamic IT Solutions (e.g. FlexFrame for Oracle) Energy cost savings “FlexFrame for Oracle” (concrete customer scenario) All Oracle services are managed by the Control Center 140000 120000 100000 -70% 80000 Euro Servers are only switched on / off due to requirement to avoid energy waste (e.g. idle mode) Energy efficient N:1 redundancy concept Shared storage systems (higher disk utilization supports energy efficiency) 122030 60000 40000 20000 35237 0 A service oriented infrastructure significantly reduces energy consumption 18 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved How to cope with the Green IT challenges? Boost Energy Efficiency in IT Infrastructures Increase use of energy efficient components Reduce consumption through efficient systems Usage of cooling optimized systems Optimize Infrastructures Consolidation Virtualization Automation Transition from a static to a dynamic IT environment Optimize Data Management Information Lifecycle Management Boost Energy Efficiency in Cooling Infrastructures Management of cooling airflow in racks / data centers 19 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Optimize Data Management Information Lifecycle Management (ILM) Mapping information to storage resources appropriate for its value Mission critical data should be stored on the high performance and secure SAS disks None critical data can be stored on the cheap and power efficient SATA disks Tape is the most energy and cost efficient way to store data Systems FibreCAT SX - supports power-efficient SATA drives and uses long-lasting capacitor instead of batteries CentricStor – Virtual Tape Library Dual target approach (disk and/or tape within one system) Managed tape storage needs less power than comparable disk solutions 20 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Tape consumes less energy than disk Disk storage system (15 disk controllers, 105 expansion units, SATA disks, 9 racks) Tape library (1 LTO tape library, 4 LTO 3 FC tape drives, 683 LTO 3 cartridges) Capacity 672 TB 672 TB List price 1.250.059 € 193.464 € Floor space 65,3 square feet 10,4 square feet Energy costs 81.334 € 3.140 € SATA disk systems have nearly 26 times higher energy costs than tape systems SATA disk system acquisition cost are about 6.5 times the cost of tape systems The cost to power and cooling equipment must be part of the TCO CentricStor makes tape fit for ILM and allows dramatic energy savings 21 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Storage giant from 1971 Werner Girbardt from the Ernst-Moritz-Arndt-University Greifswald, Germany displays an over 30 years old disk from Telefunken. The weight was 10 kg and the storage capacity was 2 MB. Newest disks today offer capacities up to 1 TB. (500.000 times as much) 22 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved New technology saves energy FibreCAT S80 Announced Capacity Power consumption Watt / TB Energy costs / year FibreCAT SX80 (SATA) FibreCAT SX80 (SAS) 01.3.2002 01.02.2006 01.02.2006 4,1 TB* 56 FC disk (73 GB) 4,5 TB** 6 SATA disks (750 GB) 4,2 TB** 14 SAS disks (300 GB) 3.257 W 295 W 666 W 795 65,56 158,57 2.853,13 € 258,42 € 583,42 € Save real money by using state of the art storage technology * max capacity **capacity to compare, max capacity 42TB(SATA)/16,8TB(SAS) 23 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved How to cope with the Green IT challenges? Boost Energy Efficiency in IT Infrastructures Increase use of energy efficient components Reduce consumption through efficient systems Usage of cooling optimized systems Optimize Infrastructures Consolidation Virtualization Automation Transition from a static to a dynamic IT environment Optimize Data Management Information Lifecycle Management Boost Energy Efficiency in Cooling Infrastructures Management of cooling airflow in racks / data centers 24 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Energy efficient cooling The flexible and future-proven Cool-safe™ System design Separate air tunnels Automatic controlled large fans PRIMECENTER Liquid Cooling Rack – reliable and energy-efficient water-cooled rack solution for highest cooling requirements Optimize cooling infrastructure Careful management of the air flow in racks and in the data center Constant matching of the cooling system of current operating needs Use of low-loss UPS systems 25 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved The mistakes people make Not using the On/Off switch Not implementing technologies to automate switching off unwanted systems Not fully decommissioning old machines Having separate development and testing systems Underutilisation of systems or full redundancy Bad airflow for cooling Leaving PC’s on over night “ready for the morning” Expanding on-line storage instead of offline backups – Lack of Information Lifecycle management 26 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Cost / Benefit of Green IT Activities High 1) Execute quick wins Improve efficiency of existing assets Revamp architecture and infrastructure Green Contribution Turn off unused equipment Implement thin-client systems Improve data center airflow Virtualize and Implement PC and server consolidate servers power management Upgrade power supplies Optimize data center cooling Virtualize and Simplify data consolidate storage center cabling Low 1) Low 27 Upgrade servers Jürgen Heidegger Resource intensity Green IT © Fujitsu Siemens Computers 2008 All rights reserved Forrester, Creating The Green IT Action Plan, Oct. 2007 High Fujitsu Siemens Computers’ environmental pioneering and social commitment has long tradition 1988: Taking back old IT equipment 1992: Guideline set for environmentally conscious design 1993: First ‘Green PC’ in the market 1994: First IT manufacturer to receive Blue Angel eco-label 2002: First ‘green’ mainboard 2005: Joining the U.N. Global Compact 2006: PRIMERGY - Intelligent Power Management 2007: First “Green Server” PRIMERGY TX120 2007: Energy Star 4.0 Compliance 28 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved “Greener Computing” Energy efficient IT systems Energy efficient IT solutions Energy efficient IT infrastructures For a better business For a better planet 29 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved Thank you. 30 Jürgen Heidegger Green IT © Fujitsu Siemens Computers 2008 All rights reserved
© Copyright 2026 Paperzz