Evaluation of a New Automated Method for Lactic Acid Bacteria Enumeration in Food Products Using the TEMPO® System Grégory Devulder, Cidem Ilter, Audrey Maingue. RESULTS INTRODUCTION 1/10 dilution Decimal dilutions DILUTIONS Result agreement for within range between TEMPO and the reference method 1mL Pour ~15 mL MRS (De Man, Rogosa and Sharpe) Analysis: The comparison in terms of enumeration (T-test, bias and regression) was performed on within range data: this means that for both methods, the log decimal transformation is possible. The analysis of below and above range was performed using the rate of agreement results. Distribution of food products tested by category: # Matrices tested at 35°C Sample Type Bakery Miscellaneous * 17 Dairy 53 Poultry Meat 83 Prepared food Environment 9 Vegetables / Cereals Fish and seafood 60 Number of generated results * Delicatessen, Pet food, Dressing, etc… # Matrices tested at 35°C 96 28 52 54 1276 (452 products) PREPARATION # data % agreement Within range 451 91.1 (411) Below/above range 805 98.1 (790) 1256 95.6 (1201) INCUBATION MATERIALS AND METHODS 40-48h - 35°C - aerobic conditions 72h - 35°C - anaerobic conditions READING Total The bias (mean of the log difference) is -0.11 [-0.05 ; -0.16] with a confidence interval at 95% close to 0. 1256 within range and below above range results were used for the comparison. We observed a rate of agreement of 91.1% and 98.1% for within range and below above range respectively and a global rate of agreement higher than 95% on all food categories. No significant difference was observed regarding the different categories of food products tested. Log TEMPO vs Log Reference The TEMPO LAB method presents important advantages compared to the reference method: The enumeration of Lactic Acid Bacteria is often fastidious and time consuming due to the high number of dilutions. The use of the TEMPO system allows an enumeration range of 3.7 log with the same card which decreases significantly the number of dilutions: one card for 3 plates. The incubation of TEMPO card is performed aerobically compared to the MRS method or PetrifilmTM which are incubated in anaerobic conditions. The incubation time is 40-48h compared to 72 hours for the reference method allowing time saving for the result and space saving in the incubator. CONCLUSION Results obtained with the TEMPO LAB parameter were not statistically significantly different than those obtained by plate count on MRS agar, showing a satisfactory agreement between both methods. TEMPO LAB method can be considered as an effective rapid alternative method for the enumeration of lactic acid bacteria in food products offering significant advantages to the reference method. 8 DISCUSSION 6 The linear regression : y=0.22 + 0.93x shows a coefficient of correlation of 0.94. 4 At 35°C, TEMPO LAB shows equivalent results to the Compendium method with a global rate of agreement close to 96%. A slight tendency for under enumeration is observed on all food categories. Some under enumeration could explained by the presence of yeasts on MRS. It is sometimes recommended to add sorbic acid to the MRS medium if there is a risk of yeast contamination (ex ISO 15214). The performance are comparable or better than performance observed for the comparison between PetrifilmTM and the reference method which shows a slight over enumeration. Log (TEMPO LAB) Reference method: Rehydrated MRS medium was prepared according to manufacturer’s instructions. The pH of the medium was adjusted to 5.5 after autoclaving using sterile glacial acetic acid to obtain the pH-modified agar. Inoculated plates in duplicate were incubated anaerobically at 35°C for 72 ± 3 hours. TEMPO method: TEMPO LAB is a method for Lactic Acid Bacteria enumeration, based on the familiar format of the TEMPO MPN procedure. The method uses a new selective dehydrated culture medium and an enumeration card containing 48 wells across 3 different dilutions for the automatic determination of the MPN. Filled cards were incubated aerobically at 35°C for 40-48 hours. Alternative method (PetrifilmTM): PetrifilmTM Method was performed according to manufacturer’s instructions. The MRS broth used as diluent is Difco Lactobacilli MRS broth 288130, pH 6.5 adjusted to 5,7 after autoclaving with sterile glacial acetic acid. Inoculated Aerobic Count Plate were incubated anaerobically at 35°C for 48 ± 3 hours. On 1276 results (452 different matrices), • 18 eliminated reference results due to incoherence between successive dilutions. • 2 eliminated TEMPO results due to difficulties for the system to interpret the card 2 In this study, we compared the new TEMPO LAB enumeration method to the Compendium method for the microbiological examination of foods: MRS agar incubated at 35°C anaerobically for 72 ± 3 hours. At the same time, the 3MTM PetrifilmTM method was compared to the reference method on a subset of data. 1 mL or 0.1 mL 0 Whereas Lactic Acid Bacteria (LAB) are considered beneficial in the manufacture of fermented products they can also act as spoilage organisms, which shorten product shelf life and degrade product quality. Traditional methods for enumerating LAB in food products involve time-consuming plating techniques. Sample Type P3-46 bioMérieux SA, Marcy-l'Etoile, France 0 2 4 6 8 Log (Reference) Result agreement for within range between PetrifilmTM and the reference method The same analysis was performed on 216 food products to compare PetrifilmTM and the reference method: # data % agreement Within range 102 84.3 (86) Below/above range 114 93.0 (106) 216 88.9 (192) Total The bias (mean of the log difference) is +0.24 [0.07 ; - 0.41] with a confidence interval at 95% close to 0.
© Copyright 2026 Paperzz