Fabrications, Safety NBS & Lighting Solutions Specification Kingspan Day-Lite Architectural Horizontal KS1000 DLAWP NBS Specification NBS: Project: Date: H43 METAL COMPOSITE PANEL CLADDING / COVERING To be read with preliminaries / general conditions. TYPE OF CLADDING SYSTEM 127A POLYCARBONATE TRANSLUCENT WALL CLADDING TO WALLS Drawing reference(s): _________ Supports: Kingspan Multibeam cold rolled cladding rails. Bearing width: Intermediate: Minimum 60mm, Vertical joint: Minimum 130mm. Manufacturer and reference: Kingspan Insulated Panels, horizontally-laid translucent polycarbonate wall light system for standard internal and external environments. Profile reference: Kingspan Day-Lite Architectural, KS1000 DLAWP, integrating with AWP insulated wall panel. - Material: Co-extruded, multi-wall polycarbonate rigid thermoplastic wall light. Kingspan Day-Lite products fully satisfy the requirements of the National Building Regulations achieving Euro Class B internally and National Class AA and Euro Class BROOF(t4) externally. Kingspan Day-Lite Architectural achieves a classification of B-s2,d0 when tested to EN 13501-1: 2007.Cover width: 1000mm, multi-wall polycarbonate thickness 38mm. - Panel thickness: 80mm (38mm polycarbonate + aluminium extrusion, depth to suit adjacent panel thickness). - Colours: Kingspan Day-Lite. Male / female joint sealant: - Factory applied weather seal set in rebate. - Kingspan AWP filler and low modulus polycarbonate compatible seal, site applied at the end of each panel where flashings pass over the joint. - Bridging seal across panel joint in line with AWP filler and internal air seal to be polycarbonate compatible non-setting gun-grade sealant. Vertical joints: - Type: Option A with recessed top-hat flashing and insert with 4mm diameter butyl rubber sealant. - Colours: Kingspan Day-Lite, as per external face of panels. - PIR insulation board. - Vertical panel joint to have VJ2 EPDM 95mm x 10mm self-adhesive air seal bubble gasket applied to vertical supporting steelwork and lapped over drip flashing. Fasteners: As determined by clause 220A. Number and location: - For wall light: As determined by clause 197A, but with each wall lite fixed to each support using not less than one fastener at panel ends and two fasteners at intermediate supports, located through tongue section, as recommended by cladding manufacturer. - For panel bearers: Fix each one using two fasteners. - For vertical top-hat fix to vertical support at 500mm centres. Accessories: - Profile fillers as clause 300A. - Panel bearers, maximum 1500mm centres, located in positions recommended by cladding manufacturer to support the bottom row of horizontally laid Kingspan Day-Lite Architectural wall lights. NBS Specification Thermal transmittance (U-value) of 1.3W/m²K calculated using the method required by the Building Regulations Part L2 (England and Wales) and Building Standards Section 6 (Scotland). - Manufacturers 25 year structural and thermal guarantee required. - Air leakage rate of 3m3/hr/m2 at 50Pa, based on the assumption that the full building envelope is constructed using Kingspan panels. Other requirements: - Internal face of Kingspan Day-Lite Architectural to be air sealed along the full length by an unbroken 6mm diameter bead of polycarbonate compatible gun grade sealant - Factory made pre-formed corner Kingspan Day-Lite Architectural. - Manufacturers 25 year product guarantee to be available on project completion and be fully transferrable for future changes of building ownership. - PVC barrier tape applied between aluminium spacer and cold rolled cladding rails to prevent a bi-metallic corrosion. - Panels manufactured under the following ISO standards: ISO 9001 (Quality), ISO 14001 (Environmental), OHSAS 18001 (Health & Safety) and ISO 50001 (Energy). - Cladding contractor to attend a product training course at Kingspan Insulated Panels. 197A ATTACHMENT Determine the number and location of cladding fasteners recommended by the cladding manufacturer to resist wind loads calculated in accordance with BS 6399: Part 2 Standard Method and BS 5427: Part 1. Calculate wind loads on roof and wall cladding appropriate to location, exposure, roof height, building shape and size in accordance with BS 6399: Part 2 Standard Method and BS 5427: Part 1. - Basic wind speed (Vb): ___ m/s - Altitude factor (Sa): ___ - Direction factor (Sd): ___ - Seasonal factor (Ss): 1 - Probability factor (Sp): 1 - Terrain and building factor (Sb): ___ - External and internal size effect factors (Ca): 1 - External pressure coefficients (Cpe): As determined from BS 6399: Part 2, clauses 2.4 and 2.5. - Internal pressure coefficients (Cpi): As determined from BS 6399: Part 2, clause 2.6. - Dominant opening: _________ 220A FASTENERS Recommended manufacturer: to be confirmed by architect / cladding sub-contractor. Wall light fasteners: Self-drilling, self-tapping screws with bonded washers. - Type(s), size(s) and drilling capacity: As recommended by fastener manufacturer to suit type and thickness of supports, and thickness of cladding panels. - Screw material: Grade 304 Austenitic Stainless Steel. - Washer material: Non-ferrous. - Washer size: 16 mm diameter. - Heads: Hexagon head. Fasteners for vertical joint flashings / trims: As panel fasteners. Fasteners for panel bearers: As panel fasteners but with 15mm diameter washers. Flashing fasteners: Ejot 5.2mm Bulb-Tite rivet or similar. NBS Specification 275 CONTINUITY THERMAL INSULATION PIR insulation board. Placement: Secure and continuous with cladding / covering insulation. 300A PROFILE FILLERS GENERALLY: Drawing reference(s): _________ Manufacturer and reference: Kingspan Insulated Panels. Material: Polyethylene foam. Colour: White. Fixing: Seal the perimeter edges of the filler to abutting components using a polycarbonate compatible gun grade sealant. Locate where shown on drawings and wherever necessary to close off behind the ends of the wall lights against supports, at wall light ends only. 310A PURPOSE MADE COLD FORMED METAL ACCESSORIES – EXTERNAL Drawing reference(s): _________ Material / finish: As per external face of cladding. Thickness: 0.63mm Colour: To match external face of cladding. Workmanship as section Z11. Fixing: Stitch to external face of panels at 450mm centres using Ejot 5.2mm Bulb-Tite rivet Sealing: Single line of 4mm diameter butyl rubber sealant Class A, ref: NFRC TB36 and a 6mm bead of polycarbonate compatible gun grade sealant, site applied between flashing and panel. 311A PURPOSE MADE COLD FORMED METAL ACCESSORIES – INTERNAL Drawing reference(s): _________ Material / finish: As internal face of cladding. Thickness: 0.4mm. Colour: White. Workmanship as section Z11. Fixing: Stitch to internal face of wall light at max. 450mm centres using Ejot 5.2mm Bulb-Tite rivet. Sealing: Single line of 6mm bead of polycarbonate compatible gun grade sealant, site applied between flashing and panel. End laps to be air sealed with Film backed Butyl tape / PremSeal SWRPIO or similar, or gun grade sealant. Kingspan Limited Sherburn, Malton, North Yorkshire, YO17 8PQ t: +44 (0) 1944 712444 f: +44 (0) 1944 710830 www.kingspanpanels.co.uk Registered Office at Greenfield Business Park No.2, Greenfield, Holywell, Flintshire, N. Wales CH8 7GJ. Company Reg. No. 1037468 06/2015
© Copyright 2026 Paperzz