TABmaster Model 6715

TABmaster Model 6715
Instruction Manual
Be sure to read this manual thoroughly before using the instrument ,
fully understand and pay attention to each cautions mentioned.
Please well-keeping this manual for long time service reference.
01003
14.10
CONTENTS
Product Configuration..................................................................................................................... 3
Caution........................................................................................................................................... 5
1. Introduction ................................................................................................................................ 7
1.1. Features............................................................................................................................. 7
1.2. Specifications ..................................................................................................................... 7
2. Outlook & Structure .................................................................................................................... 8
2.1. Base structure .................................................................................................................... 8
2.2. Micromanometer ............................................................................................................... 9
3. Settubg up................................................................................................................................... 9
3.1. Capture Hood .................................................................................................................... 9
3.2. Velocity Grid.....................................................................................................................10
3.3. Pitot tube .......................................................................................................................... 11
3.4. Micromanometer .............................................................................................................. 11
3.5. Shoulder Strap.................................................................................................................. 11
4. Operating Instruction .................................................................................................................12
4.1. Power supply ....................................................................................................................12
4.2. Start On / Power Off .........................................................................................................12
4.3. Keypad operation..............................................................................................................13
5. Function test...............................................................................................................................14
5.1. User Interface ...................................................................................................................14
5.2. Single Mode ......................................................................................................................15
5.3. Average Mode ...................................................................................................................15
5.4. Back Pressure Mode ..........................................................................................................15
6. Menu setting...............................................................................................................................16
6.1. General setting..................................................................................................................17
6.1.1. Date ........................................................................................................................17
6.1.2. Time .......................................................................................................................17
6.1.3. Auto Off..................................................................................................................17
6.1.4. Backlighting............................................................................................................18
6.1.5. Communication.......................................................................................................18
6.2. Test setting........................................................................................................................19
1
6.2.1. Tools .......................................................................................................................19
6.2.2. ID application .........................................................................................................20
6.2.3. Test Mode ...............................................................................................................20
6.2.5. Data record .............................................................................................................21
6.2.6. Standard/Actual test ................................................................................................21
6.2.7. Compensation factor ...............................................................................................22
7 Error and Troubleshooting...........................................................................................................23
8 Warranty and Service ..................................................................................................................24
8.1. Product Warranty.............................................................................................................24
8.2. After service......................................................................................................................24
2
Product Configuration.
6715 Standard:
Item.
Qt’y
Micromanometer Model 6700
Instrument Base
1
Fabric Hood: 2ft×2ft
1
Carrying case
1
Portable handle
1
Frames
1
Poles
4
Communication cable
1
Calibration certificate
1
CD-Rom(Manual and software inside)
1
Quick-Guide
1
1
6715 Optional Parts:
Item.
Specifications
Spare hood 2x2ft
Spare hood 2x4ft
Spare hood 1x4ft
Spare hood 3x2ft
Spare hood 3x3ft
Spare hood 500x500mm
Poles
Up to 3.4m with capture hood
Capture Hood Stand
Communication cable
Printer
AC adapter
DC5V
International plug adapter
Carrying case
Velocity Grid
Pitot tube (2.3 x 200mm)
Pitot tube (4 x 300mm)
Pitot tube (8 x 500mm)
Pressure tubing
2*250cm
3
6700 Standard:
Item.
Qt’y
Micromanometer Model 6700
1
Carrying case
1
Pressure tubing
2
Communication cable
1
Calibration certificate
1
CD-Rom(Manual and software inside)
1
Quick-Guide
1
6700 Optional Parts:
Item.
Specifications
Velocity Grid
Pitot tube (2.3 x 200mm)
Pitot tube (4 x 300mm)
Pitot tube (8 x 500mm)
Pressure tubing
2*250cm
Shoulder Strap
Printer
AC adapter
DC5V
International plug adapter
Communication cable
4
Caution.
The symbols for warning mentioned in this manual are defined below:
〔symbols classifications〕
Danger: To Prevent Serious Injury or Death
Wa rnings in this classifi cation indi cate a danger tha t ma y resul t in serious injury or dea th if not observed .
Caution: To Prevent Damage to the Product
Wa rnings in this classifica tion indi ca te a risk of damage to the product tha t ma y void the product wa rranty if not
observed.
〔 Description of Symbols〕
△ This s ymbol indi ca tes a condi tion tha t requi res caution (including danger). The subject of ea ch cauti on is
illustra ted inside the triangle .
This s ymbol indica tes a prohibi tion. Do not take the prohibi ted a ction shown inside or nea r this s ymbol .
● This symbol indicates a mandatory action. A specific action is given near the symbol.
WARNING
○
Never bring the fabri c hood to a flammable gas
a tmosphere.
Heated forbidden
Disassemble
…
otherwise, the hea t ma y cause a fi re or explosion.
○
Do not disassembl y or refi t the instrument.
…
otherwise, ma y cause the electri c shock or a fi re.
○
Using properl y under the instruction manual.
…
otherwise, ma y cause sensor da maged or an electri c shock even a fire.
○
If abnormal smells, noises or s moke occur, or if liquid enters the ins trument, pull out
prohibition
Using properly
the AC adapter and remove the batteries immedia tel y. Then send i t to the
maintena nce Dept. of KANOMAX for after servi ce.
Using properly
…
or, there is possible of an electri c shock or a fi re or instrument malfunction.
○
Do not expose the fabri c hood, base and the ins trument
noumenon in the rain.
…
Forbidden
otherwise, ma y cause an electri c shock, an fire and an
person injure.
5
CAUTION
Using properly
○
Alwa ys unplug when the instrument not in use.
…
Failure to do so ma y cause an electri c shock, an fire or ci rcui t da mage.
○
Remove the ba tteries when s tori ng the instrument for a l ong period. Do not lea ve
the exhaused batteries in the ba ttery compa rement and exchange the ba ttereis on
time.
Using properly
Using properly
…
Failure to do so ma y cause the batteries leakage and the ins trument dama ge.
○
Ma tching the correct AC adapter outwa rd as reqes ted.
…
or ma y ca use the ins trument dama ge.
○
Do not wipe the ins trument wi th a vola tile sol vent.
…
the body ma y deform or deteri ora te. Use a soft dry cl oth to remove stains . If stains
persist, soak the cloth in a neutral detergent a nd wipe the i nstrument with the soft
Forbidden
cloth. Never use vola tile sol vents such as thinner or benzene .
○
Do not use or lea ve the ins trument in a high
temperature, high humidi ty or dus ty envi ronment. Do
not lea ve the instrument under di rect sunlight.
…
Forbidden
otherwise, the instrument ma y not function properl y
out of the speci fied opera ting condi tions or the inside
components damaged.
○
Never dropping the uni t or pla cing hea vy objects on i t
…
It ma y cause damage or malfunction to the ins trument
Forbidden
6
1. Introduction
TABmaster Model 6715 is a kind of intelligent test instrument with multi functional of airflow test, velocity
test and micro-Differential pressure test. It’s widely used in air flow and velocity testing of air - conditioning,
HAVC system and other places, especially for the high precision micro differential pressure test.
1.1. Features

3.5 inch true color LCD.

Available measuring the air flow, velocity, temperature and humidity at the same time.

Two kinds of tests are available of in flowing and exhaust flowing.

Back pressure compensation.

Ultra-large Storage capacity: 8000 records

Blue tooth communication makes remote monitoring and data transferring available.

Light weight, compact configuration for easy carrying.

Data printing or transferring to the computer.
1.2. Specifications
Items
Specifications
Test range
40~4300 m3 /h
Accuracy
±3% of readings ± 8m3 /h(>85m3 /h)
Resolution
Test range
1 m /h
0.15~40 m/s(Pitot Tube)、0.15~15 m/s(Velocity Grid)
Accuracy
±3% of readings ±0.05m/s(>0.25m/s)
Resolution
0.01m/s
Test range
-2500~2500 Pa
Accuracy
±0.25% of readings ±1Pa
Resolution
0.001 Pa
Test range
0~60℃
Accuracy
±0.5℃
Resolution
0.1℃
Test range
0~100%RH
Accuracy
±3%RH(10~90%RH)
Resolution
0.1%RH
Test range
70~130 kPa
Accuracy
±2% of readings
Resolution
0.1 kPa
Air flow
Air velocity
Differential
pressure
Temperature
Humidity
Absolute
pressure
3
Operation Temp.
0~60℃(non condensing )
Storage Temp.
-20~70℃(non condensing)
Power Source
4 pcs of AA-size buttery ( approx. 9hrs available)or DC5V Adapter
Weight
3.6kg approx.
7
2. Outlook & Structure
Frame
Poles
Pi vot
Wi ndow
Fabri c
Hood
Ins trument
Base
Mi cromanometer
2.1. Base structure
1.Outlook
Potable handle
Mi cromanometer
Ba ck pressure
ON/OFF
Adjus t handle
Base buttom
Test handle
2.Internal view
3.Grid
Ba ck pressure plate
Testing
Poles
point
Grid
8
2.2. Micromanometer
Displa y LCD
Keypad
Cover lock
Front view
Power on/off
Ai r port (+)
Ba ttery Compa rtment Cover
Ba ck
Mini USB Port
Ai r port (-)
Top view
Bottom view
3. Settubg up
3.1. Capture Hood
1.Fabric Hood & basement
、
(1)
(2)
(3)
(4)
Note:
1)
Make sure the elastic band of the fabric hood is placed exactly as shown (Figure(3)) to ensure a good fit.
The elastic band must lineup with the top lip of the base as shown. If you don’t line it up correctly, the
hood might slide off the base when you insert the poles.
2)
Use the 4 positioning holes on the base stitching as a guide to ensure the hood fully wraps around the
base..
2.Frame Poles
9
Note: The poles always cross in an “X” shape when assembling. To remove the poles, simply reverse the steps.
3.Potable handle
①
②
Note: Release the poles and portable handle when packing in the carring case to avoid case damaged.
4.Micromanometer & basement
(+)
Note: 1)Correct install the micromanometer to the base with the same S/N No.
2)Do not cross- insert the Air pines just refer to the figure as above.
3.2. Velocity Grid
Air velocity testing can be achieved when micromanometer work together with the velocity Grid.
10
(-)
Grid
Ha ndle
(+)(-)
Note: Mounting angle between the Grid and handle can be adjusted as request.
3.3. Pitot tube
Air flow and velocity testing can be achieved when micromanometer work together with Pitot tube.
Sta ti c pressure
port
Testing point
(+)(-)
3.4. Micromanometer
Differential pressure testing can be achieved by using the micromanometer.
Device
under test
(+)(-)
3.5. Shoulder Strap
When testing by Velocity Grid、Pitot tube、Micromanometer as the tool, for convenient view and easy
operation, the shoulder strap can be fit for using.
11
4. Operating Instruction
4.1. Power supply
1.Power by AC adapter. AC adapter will be as the priority power supply when the AC adapter and batteries are
all available using.
The specification of the AC adapter is:
1)AC adapter for the master
I/P:AC 110-240V 50/60HZ
O/P:DC 5V/2A。
2)AC adapter for Capture Hood
2.Power by battery

4 AA-size batteries can be used for a power supply.

Press the compartment cover lock (refer to figure indicating ①/②), and then slide the cover off to open
the battery compartment。

Put 4 AA-size batteries in and make certain the batteries are correctly oriented.

New alkaline battery or rechargeable Ni-MH battery can be used. Never mix battery types, or battery
leakage or damage to the instrument may occur.

Replace the compartment cover (refer to figure ③). The compartment cover will be automatically locked.
①
③
②

When power is supplied with batteries, the current charge value will be displayed on the upper of the LCD.
When the batteries run out of power, the instrument will turn off.
Power off
Note:
1) Do not test with low battery power.
2) Do not mixing use full power battery with low power ones for ensure testing well.
3) Change the batteries in time when power shows low for ensure testing well.
4.2. Start On / Power Off
12
POWER
2014 / 03 / 20
13 : 10
ID:
Ready
Atmos:
20.5
START
℃
01
m3/h
99.0 kPa
30.7 %RH
SAVE
MENU
Cycle:
001
Mode:
Single
1. Start On
Press button【POWER】for 2 seconds for start On, displaying “ KANOMAX” then enter into the
interface.
2. Power Off
Press【POWER】for 2 seconds, shut down and power off.
4.3. Keypad operation
Keypad panel includes control buttons, back-pressure switch and LCD adjusting keys.
1. Control buttons:
UP/SAVE
SET/MENU/OK
START/STOP/
BACK/EXIT/ESC
DOWN
START/STOP
SAVE
UP:Value increasing or Cursors upward moving.
SAVE:Save the current test results
SET:Store changes or enter into the selected option’s next level interface
MENU:On the main screen holding this down for 2 seconds will enter into the main “MENU”
OK:In the “General Setting ”, pressing for 2 seconds will save the date or time ;
While in the “Record Processing”, pressing for 2 seconds will delete saved data.
START:Begin a measurement in main menu
STOP:Stop a measurement in main menu
BACK:Cancel or end an operation or return to the previous screen
EXIT:Return to the main menu
ESC:Stop printing when printing
DOWN::Value decreasing or Cursors downward moving
2. Back pressure switch for on/off
Note :
1) If you are not in the back pressure mode, shut down the back pressure plate and lock the
switch to avoid testing errors.
2) If the airflow is greater than 1500m3 /h (883CFM), testing in back-pressure Mode is
recommended according to testing procedures.
13
testing
Ba ck pressure
On
Ba ck pressure
Off
3.LCD adjusting
Note :
1)Please switching the handle slow gently during LCD adjusting.
2)Stop turning when reach to the bound, for avoiding over turning and handle falling down.
5. Function test
Besides the airflow test, if along with other optional products, test air velocity and micro -differential
pressure is available.
5.1. User Interface
Testing information, parameter settings and the testing conditions will be displayed on the main interface.
J
A
2014 / 03 / 20
Ready
Atmos:
E
I
ID:
B
C
D
13 : 10
20.5
℃
START
m /h
99.0
30.7
SAVE
01
H
001
G
3
kPa
%RH
MENU
Cycle:
Mode:
Single
F
A. Date and time —— real-time display the current date and time
B. Testing data display —— airflow 、air velocity 、differential pressure and etc.
C. Tools icon —— working tools display
D. Testing condition —— temperature 、humidity or absolute pressure displaying according to the
14
working tools.
E. Keypad —— current status indicating and the grey state is not available.
F. Testing mode —— display the current testing mode
G. Cycle—— recorded Cycle quantity
H. ID—— current ID quantity
Power supply —— AC adapter or batteries
Blue tooth status —— when blue tooth working, the icon display or no icon display with closed.
I.
J.
5.2. Single Mode
2014 / 03 / 20
2014 / 03 / 20
13 : 10
2014 / 03 / 20
13 : 10
ID:
ID:
Ready
Atmos:
20.5
℃
01
m3/h
99.0 kPa
30.7 %RH
SAVE
START
MENU
m3/h
Cycle:
001S TART
Atmos:
20.5
Mode:
℃
Atmos:
001
20.5
Mode:
℃
99.0 kPa
30.7 %RH
SAVE
START
Single
MENU
2. Testing
1. Ready for testing
01
m3/h
Cycle:
99.0 kPa
30.7 %RH
SAVE
STOP
Single
ID:
32
01
Waiting...
13 : 10
Cycle:
001
Mode:
Single
MENU
3. tes t output
待测状态
Note:
1) START: Left-button for the Micromanometer or instrument base
2) After testing start for about 8s with stably measuring,output displaying the test data and testing wind
direction.
3) Testing stop when finish outputting.
4) Press SAVE for data record with adding 1 to the Cycle value.
5) Same testing method with the capture hood when using the Velocity Grid、Pitot、Micromanometer.
5.3. Average Mode
2014 / 03 / 20
13 : 10
2014 / 03 / 20
Ready
Atmos:
20.5
℃
99.0 kPa
30.7 %RH
SAVE
START
ID:
01
m3/h
MENU
2014 / 03 / 20
13 : 10
ID:
Cycle:
001
Mode:
Avg
Waiting...
S TART Atmos:
20.5
STOP
1.Ready for tes ting
℃
m3/h
99.0 kPa
30.7 %RH
SAVE
32
01
MENU
Cycle:
Atmos:
001
20.5
Mode:
Avg
℃
STOP
ID:
m3/h
99.0 kPa
30.7 %RH
SAVE
MENU
Cycle:
001
Mode:
Avg
13 : 10
31
01
3. test output
2. Testing
2014 / 03 / 20
13 : 10
STOP
Atmos:
20.5
STOP
℃
ID:
01
m3/h
99.0 kPa
30.7 %RH
SAVE
Cycle:
001
Mode:
MENU
4. testing stop
Note:
1) START: Left-button for the Micromanometer or instrument base.
2) After testing start for about 8s with stably measuring , output displaying the test data for the first time.
3) Go on the testing with frequency of 1s for data updating.
4) The continuously outputting is as the average data and be related with the “AvgTime” set by user. More
larger of the value of“AvgTime” will get more stable of the testing data.
5) If auto-save function On, testing data will be recorded automatically according to the setting “AutoSave”
and value of “Cycle” will be added automatically.
6) Press “STOP”, testing stop. And “STOP” will be as the Left-button for the Micromanometer or instrument
base.
7) Same testing method with the capture hood when using the Velocity Grid、Pitot、Micromanometer.
5.4. Back Pressure Mode
15
Avg
In order to reduce the measure error of the pressure loss,which causing from the hood to the system and
get the more real air flow, we suggest testing under the Back Pressure Mode when air flow more than 1500
m3/h.
2014 / 03 / 20
2014 / 03 / 20
13 : 10
Atmos:
20.5
℃
m3/h
SAVE
START
Cycle:
99.0 kPa
30.7 %RH
ID:
01
Waiting...
S TART
Atmos:
001
20.5
Mode:
STOP
B.P
MENU
1.Ready for tes ting
2014 / 03 / 20
℃
m3/h
99.0 kPa
30.7 %RH
SAVE
20.5
℃
20.5
Mode:
START
B.P
MENU
2014 / 03 / 20
m3/h
SAVE
Cycle:
001
Ready
S TART
B.P
℃
99.0 kPa
30.7 %RH
SAVE
001
Mode:
B.P
MENU
4. s wi tch on Back-Pressure Pla te
2014 / 03 / 20
13 : 10
ID:
20.5
℃
01
SAVE
START
Ready
Cycle:
99.0 kPa
30.7 %RH
MENU
B.P
Cycle:
ID:
Atmos:
Mode:
01
m3/h
13 : 10
m3/h
001
13 : 10
5. testing ready
2000
MENU
Cycle:
3. Ba ck-pressure On promoting
99.0 kPa
30.7 %RH
SAVE
START
6. testing
2014 / 03 / 20
Atmos:
20.5
Mode:
MENU
℃
01
m3/h
ID:
01
99.0 kPa
30.7 %RH
STOP
Atmos:
001
ID:
Atmos:
Open Flap !
Cycle:
2. Testing
13 : 10
Waiting...
13 : 10
ID:
01
Ready
2014 / 03 / 20
13 : 10
ID:
Atmos:
001
20.5
Mode:
8. shut off the pla te
99.0 kPa
30.7 %RH
SAVE
START
B.P
7. test output
℃
01
m3/h
Cycle:
001
Mode:
MENU
B.P
9. testing ready
Note:
1) START: Left-button for the Micromanometer or instrument base.
2) After testing start for about 8s , indicating
“Open Flap”. It’s time for switching on the Back-Pressure Plate
as needed.
3) When Back-Pressure Plate opened On, tip of “Open Flap” disappear.
4) Press START for about 8s, testing stop, real airflow outputting with back pressure compensation.
5) Press SAVE for testing data record and the meanwhile, value Cycle added 1.
6) When select Velocity Grid、Pitot tube、Micromanometer for testing, Back-Pressure compensation will be
not available.
6. Menu setting
when stop for ready, press
2014 / 03 / 20
for 2s for enter into the menu.
MENU
13 : 10
ID:
Ready
Atmos:
20.5
START
℃
99.0
30.7
SAVE
UP
01
m3/h
kPa
%RH
MENU
2s
General Setting
DOWN
Cycle:
001
Mode:
Test Setting
Avg
1)Basi c setting
SET
2)Test setting
OK
3)Working tool displayi ng below
EXIT
16
(1)2 opti onal settings :
6.1. General setting
UP
General Setting
DOWN
SET
Test Setting
(1)Basic setting:
1)Date
2)Time
3)Auto Shut
4)Backlight
5)Communicate
General Setting
MENU
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
UP
2014 / 03 / 20
13 : 10
Off
High
DOWN
SET
OK
OK
EXIT
BACK
6.1.1. Date
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
General Setting
UP
1.
2.
3.
4.
5.
DOWN
SET
Date
Time
Auto Shut
Backlight
Communicate
UP
2014 / 04 / 01
13 : 10
Off
High
DOWN
(1) press
or
for data modify.
(2)press
, for sele cting Year/Month/day.
(3)Press
for 2s for save settings.
SET
OK
OK
BACK
BACK
(4)Press
for quit.
2s
General Setting
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
20 14 / 03 / 20
13 : 10
Off
High
UP
1.
2.
3.
4.
5.
DOWN
SET
Date
Time
Auto Shut
Backlight
Communicate
UP
2014 / 04 / 01
13 : 10
Off
High
DOWN
SET
OK
OK
BACK
BACK
6.1.2. Time
General Setting
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
UP
DOWN
SET
1.
2.
3.
4.
5.
Data
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
15 : 15
Off
High
UP
(1)Press
DOWN
(2)Press
SET
or
for data modify.
for hour/minute selection.
(3)Press
for 2s for save settings.
OK
OK
(4)Press
BACK
for quit.
BACK
2s
General Setting
General Setting
1.
2.
3.
4.
5.
Data
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
UP
DOWN
SET
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
15 : 15
Off
High
2s
UP
DOWN
或
(2)按
键,时/分选项循环移动。
(3)长按
键进行数值更改。
键 2s,保存设置。
SET
OK
OK
(1)按
(4)按
键,退出设置。
BACK
BACK
6.1.3. Auto Off
When instrument not in use, it will be turn off automatically according to Auto-Off time setting to avoid
power waste.
17
General Setting
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
UP
DOWN
SET
1.
2.
3.
4.
5.
Data
Time
Auto Shut
Backlight
Communicate
OK
2014 / 03 / 20
13 : 10
Off
10 min
20 min
30 min
60 min
General Setting
Data
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
10 min
20 min
30 min
60 min
(1)Press
or
for options cha nge.
(2)Press
for save settings .
(3)Press
for quit.
DOWN
SET
OK
BACK
BACK
1.
2.
3.
4.
5.
UP
(3)按
键,退出设置。
General Setting
UP
DOWN
SET
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
10 min
High
UP
DOWN
SET
OK
OK
BACK
BACK
6.1.4. Backlighting
Adjust the LCD lighting according to the environmental brightness for the best viewing. And meanwhile, the
lower the brightness, the less battery power will be needed.
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
General Setting
UP
DOWN
SET
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
OK
2014 / 03 / 20
13 : 10
Off
Low
Normal
High
BACK
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
Low
Normal
High
(1)Press
or
for options cha nge.
SET
OK
(2)Press
for save settings .
(3)Press
for quit.
BACK
General Setting
General Setting
1.
2.
3.
4.
5.
UP
DOWN
UP
DOWN
SET
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
Low
UP
DOWN
SET
OK
OK
BACK
BACK
6.1.5. Communication
Communicate with PC, printer and Bluetooth are available. Data transfer or remote monitoring is available
by selecting communicating way.
Note:
1)PC communication means to save the testing record to the computer. And the communication cable and
software reserved for data-fetching are necessary for using together. Refer to the << Manuel for Data
fetching Software>> .
2)For printing out the testing record, the optional printer and cables for special are necessary. Printer baud
rate is set to 19200 bps and Do not change it. Refer to the << Manuel for RD series Mini printer >> .
3)Bluetooth make the remote control and data monitoring available by Hand phone. And our APP software is
necessary for using together. Refer to the << Manuel for TAB Mobile>>.
4)Shut off the switch when not use the Bluetooth communication for improving battery life.
18
General Setting
1.
2.
3.
4.
5.
Date
Time
Auto Shut
Backlight
Communicate
2014 / 03 / 20
13 : 10
Off
High
UP
DOWN
SET
OK
BACK
Communicate
Computer
UP
1. Computer
2. Printer
3. Bluetooth
Off
UP
Comfirm the Connection
DOWN
Waiting...
SET
SET
OK
OK
BACK
BACK
Print
Communicate
UP
1. Computer
2. Printer
3. Bluetooth
DOWN
Off
UP
1. Print By IDs
2. Print By Cycles
DOWN
DOWN
SET
SET
OK
OK
BACK
BACK
Communicate
Communicate
UP
1. Computer
2. Printer
3. Bluetooth
Off
UP
1. Computer
2. Printer
3. Bluetooth
DOWN
DOWN
On
SET
SET
OK
OK
BACK
BACK
5)If other settings need to be changed when Bluetooth successful communication, you need to shutdown
Bluetooth firstly then enter the menu to change other settings.
2014 / 03 / 20
Just as below shown:
2014 / 03 / 20
13 : 10
13 : 10
ID:
ID:
32
Atmos:
20.5
℃
99.0 kPa
30.7 %RH
SAVE
START
32
01
m3/h
OFF
Cycle:
2s
001
Atmos:
20.5
Mode:
℃
Avg
99.0 kPa
30.7 %RH
SAVE
START
01
m3/h
MENU
Cycle:
001
Mode:
Avg
6.2. Test setting
Test Setting
MENU
UP
General Setting
DOWN
SET
Test Setting
OK
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
EXIT
6.2.1. Tools
19
Test settings:
UP
RunAvg
DOWN
SET
Act
1.000
OK
BACK
1)Select Tool
2)Test ID
3)Test Mode
4)Unit
5)Data Record
6)Standard/Actual testing
7)Compensation factor
The TABmaster model 6715 is an instrument for airflow, air temperature, and relative humidity
measurements. The optional accessories (Velocity Grid, Pitot tube, and Micromanometer) expand the
parameters that the instrument can measure. Refer to the Chapter 3 and 5 for details.
Test Setting
1.
2.
3.
4.
5.
6.
7.
Select Tool
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
SET
Act
1.000
(1)Press
SET
3. Pitot
OK
OK
BACK
or
for options cha nge.
DOWN
2. Velocity Grid
4. Pressure
P
(2)Press
for save settings .
(3)Press
for quit.
BACK
Test Setting
Select Tool
UP
1. Capture Hood
DOWN
2. Velocity Grid
SET
3. Pitot
OK
4. Pressure
UP
1. Capture Hood
P
BACK
1.
2.
3.
4.
5.
6.
7.
Tools
TABmaster
Velocity Grid
Pitot tube
Micromanomete r
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
SET
Act
1.000
OK
Test item
Air flow / Temperature / RH
Air velocity
velocity
Micro-differe ntial pressure
BACK
6.2.2. ID application
Test Setting
1.
2.
3.
4.
5.
6.
7.
Test ID
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
01
1. Select ID
2. Add New ID
No
SET
Act
1.000
Total ID:
OK
20
UP
(1) Test ID is up to 20.
DOWN
(2) Set different Test ID for the di fferent tool .
SET
(3) 100 data records can be stored in a single
OK
BACK
ID
BACK
6.2.3. Test Mode
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
Single
DOWN
SET
Act
1.000
1. Select Tool
2. Test ID
3. Test Mode
Avg Time:
Auto Save:
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
OK
DOWN
SET
OK
BACK
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
UP
Single
RunAvg
B.Prees
Act
1.000
DOWN
SET
OK
BACK
1.
2.
3.
4.
5.
6.
7.
RunAvg
03 Sec
Off
10 Sec
20 Sec
30 Sec
60 Sec
DOWN
SET
OK
BACK
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
SET
Act
1.000
20
the more s table the testing value will
be as spikes in ai rflow will be avera ged
out over time.
(2)“Auto Sa ve” is a time interval for
UP
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
SET
Test Setting
1. Select Tool
2. Test ID
3. Test Mode
Avg Time:
Auto Save:
testi ng; the longer the ti me peri od,
DOWN
BACK
BACK
UP
Single
RunAvg
B.Prees
Act
1.000
RunAvg
03 Sec
Off
OK
Test Setting
1.
2.
3.
4.
5.
6.
7.
(1)”Avg Ti me” is as a peri od for
UP
OK
BACK
automa tic da ta recording during testing.
6.2.4. Units
Unit
Test Setting
1.
2.
3.
4.
5.
6.
7.
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
m3/h
CFM
l/s
lbs
1. Airflow
2. Atoms
3. Temperature
DOWN
SET
Act
1.000
UP
(1)Press
or
for options cha nge.
(2)Press
for save settings .
(3)Press
for quit.
DOWN
SET
OK
OK
BACK
BACK
Unit
Unit
CFM
kPa
℃
1. Airflow
2. Atoms
3. Temperature
UP
m3/h
kPa
℃
1. Airflow
2. Atoms
3. Temperature
DOWN
UP
DOWN
SET
SET
OK
OK
BACK
BACK
6.2.5. Data record
Test Setting
1.
2.
3.
4.
5.
6.
7.
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
SET
OK
Act
1.000
BACK
Test ID: 01
Data Record
Cycle:
Total: 20
UP
UP
1. Display the Record
2. Delete the Record
Max:
DOWN
m3/h
0
DOWN
Min :
0
m3/h
Avg:
0
m3/h
SET
SET
OK
OK
Press [SET] See Cycle Data
BACK
Data Record
01
Total: 01
AirFlow:
Atmos :
Temp:
Humidity:
Std/Act:
Time:
0 m3/h
101.3 kPa
21.1 ℃
35.8 %RH
Std
2014 / 03 / 18
13 : 10 : 18
BACK
UP
DOWN
SET
OK
BACK
Delete
1. Display the Record
2. Delete the Record
UP
DOWN
SET
OK
UP
No
1. Delete All
2. Delete IDs
Select ID: 01
3. Delete Cycles
Select ID: 01
Select Cycle: 001
DOWN
No
SET
No
OK
BACK
BACK
Note:
1) Browsing or deleting test data in current testing tools is available for allowed.
2) Data exporting by communication function and deleting the non-valid data in time for the effective
storage space.
3) Pressing
for 2 seconds will delete saved data.
6.2.6. Standard/Actual test
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
UP
RunAvg
DOWN
SET
Act
1.000
OK
BACK
1.
2.
3.
4.
5.
6.
7.
Test Setting
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
DOWN
SET
Act
Std
21
OK
BACK
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
UP
RunAvg
DOWN
SET
Std
1.000
OK
BACK
Note:
1) Standard Test (Std): in the condition of atmosphere 101.3kPa and temperature 21.1℃.
2) Actual Test(Act): in actual condition with the compensation for the atmosphere and temperature.
3) No Std/Act selection when in Micromanometer testing.
4) When doing actual testing under Velocity Matrix and pitot tube, manually input the current
temperature is needed for the compensation.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
Temperature
Test Setting
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
8.
Refer to the figures as below:
UP
RunAvg
DOWN
SET
Act
1.000
23.5 ℃
OK
BACK
1.
2.
3.
4.
5.
6.
7.
8.
UP
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
Temperature
RunAvg
1.
2.
3.
4.
5.
6.
7.
8.
DOWN
SET
Act
1.000
25.0 ℃
OK
BACK
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
Temperature
UP
RunAvg
DOWN
SET
Act
1.000
25.0 ℃
OK
BACK
6.2.7. Compensation factor
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
UP
RunAvg
DOWN
SET
Act
1.000
OK
BACK
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
1.
2.
3.
4.
5.
6.
7.
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
Select Tool
Test ID
Test Mode
Unit
Data Record
Std/Act
K factor
RunAvg
SET
Act
1.010
(1)Press
or
for options cha nge.
(2)Press
for save settings .
(3)Press
for quit.
DOWN
OK
BACK
Test Setting
Test Setting
1.
2.
3.
4.
5.
6.
7.
UP
UP
RunAvg
DOWN
SET
Act
1.000
OK
BACK
UP
RunAvg
DOWN
SET
Act
1.010
OK
BACK
Note:
1) Under Capture Hood and Velocity Grid testing, K factor is used for testing data compensation in
order to get more accuracy result. And the testing range will be 0.500~1.500.
Note: K factor will affect the accuracy of measurement, so, it’s necessary for having the test bench for
standard reference and using with caution.
For example:
If the Capture Hood is as the selected testing tool, testing value by Model 6715 is 1000m3 /h,
the standard airflow is 1020m3 /h,at this point, K factor= standard value/testing value =1.020,input
this K factor to correct the accuracy of the measurement by Model 6715.
2) Under Pitot tube testing, K factor is the factory standard coefficient and each pitot with its own
independent factor.
3) No K factor setting under the micromanometer testing.
22
7 Error and Troubleshooting
Symptom
No display when power On
Possible causes
Corrective action
incorrect specification of the AC
Check and refer to Chapter4.1
Adapter
in Manuel
Check and refer to Chapter4.1
Battery installation error
in Manuel
Low or dead battery power
Display “Connect Error”
Display “DATA Error”
Press “START” but no response
Testing record can not be saved
New ID can not be added
Replace the batteries
Connection cable loss with the
base
Back-Pressure
mode
using
incorrect
Reseat the connect cable
Refer to Chapter 5.4 in Manuel
Low battery charge
Replace new batteries
Back Pressure Plate opened On
Shut off the plate
Over-limit Cycle
current ID
Add new ID or delete some
data
quantity in
ID over-limit
Delete some ID
Current ID is without “Cycle”
Using the current ID
Unmatched printer
Printing unreadable code
Wrong baud rate setting
23
Using our special optional
printer supplied by us.
Reset referring to the Printer
Manuel
8 Warranty and Service
8.1. Product Warranty
The limited warranty set forth below is given by KANOMAX GROUP COMPANIES with respect to the
KANOMAX brand capture hood and other accessories (hereafter referred to as “PRODUCT”) purchased
directly from KANOMAX GROUP COMPANIES or from an authorized distributor.
Your PRODUCT, when delivered to you in new condition in its original container, is warranted against defects
in materials or workmanship as follows: for a period of one (1) year from the date of original purchase, defective
parts or a defective PRODUCT returned to KANOMAX GROUP COMPANIES, as applicable, and proven to be
defective upon inspection, will be exchanged for a new or comparable rebuilt parts, or a refurbished PRODUCT as
determined by KANOMAX GROUP COMPANIES. Warranty for such replacements s hall not extend the original
warranty period of the defective PRODUCT.
This limited warranty covers all defects encountered in normal use of the PRODUCT, and does not
apply in the following cases:
(1) Use of parts or supplies other than the PRODUCT sold by KANOMAX GROUP COMPANIES, which cause
damage to the PRODUCT or cause abnormally frequent service calls or service problems.
(2) If any PRODUCT has its serial number or date altered or removed.
(3) Loss of damage to the PRODUCT due to abuse, mishandling, alternation, improper packaging by the
owner, accident, natural disaster, electrical current fluctuations, failure to follow operation,
maintenance or environmental instructions prescribed in the PRODUCT's operation manual provided by
KANOMAX GROUP COMPANIES, or service performed by other than KANOMAX GROUP COMPANIES.
NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, APPLIES TO THE PRODUCT AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED
WARRANTY STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED
ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCT SHALL BIND KANOMAX GROUP
COMPANIES. KANOMAX GROUP COMPANIES SHALL NOT BE LIABLE FOR LOSS OF STORAGE CHARGES, LOSS
OR CORRUPTION OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY
THE USE OR MISUSE OF, OR INABILITY TO USE, THE PRODUCT, REGARDLESS OF THE LEGAL THEORY ON
WHICH THE CLAIM IS BASED, AND EVEN IF KANOMAX GROUP COMPANIES HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST KANOMAX GROUP
COMPANIES BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY KANOMAX
GROUP COMPANIES AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, THE
OWNER ASSUMES ALL RISK AND LIABILITY FOR LOSS, DAMAGE OF, OR INJURY TO THE OWNER AND THE
OWNER'S PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OF, OR
INABILITY TO USE, THE PRODUCT NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF KANOMAX G ROUP
COMPANIES. THIS LIMITED WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN THE ORIGINAL
PURCHASER OF THE PRODUCT, OR THE PERSON FOR WHOM IT WAS PURCHASED AS A GIFT, AND STATES THE
PURCHASER'S EXCLUSIVE REMEDY.
8.2. After service
 When you have a problem with your instrument, please check out the “Common Trouble Shooting”
section first.


If that does not help, please contact your local distributor, or contacts on the last page.
During the warranty period, we will repair at no charge a product that proves to be defective due to
material or workmanship under normal use. (See Section 14.1 Warranty)
 All return shipping charges are the responsibility of the customer.
24

Repair after warranty expiration:

Upon request, we will repair the instrument at the customer’s expense, if the instrument’s
performance is found to be recoverable by providing the repair.
 Replacement parts are available for a minimum period of five (5) years after termination of production.
This storage period of replacement parts is considered as the period during which we can provide
repair service. For further information, please contact your local distributor, or contacts on the last page.
When making an inquiry, please provide the following information :
* PRODUCT NAME
---------* Model No.
---------* Serial No.
---------* Description of the problem : ---------* Data of Purchase: Day, Month and Year
25
Kanomax Group Companies
■ Americas, Europe, Mid-East, Africa, Oceania
KANOMAX US A, INC.
219 US Highway. 206, Andover, New Jers ey 07821
TEL: 1-800-247-8887(USA ) / 1-973-786-6386
FAX: 1-973-786-7586
URL: www.kanomax -usa.com
E-Mail: [email protected]
■ Japan & Asia
KANOMAX JAPAN, INC.
2-1 Shimizu Suit a City, Osaka Japan 565 -0805
TEL: 81-6-6877-0183
FAX: 81-6-6879-2080
URL: www.kanomax.co.jp
E-Mail: [email protected]
■ China
Shenyang Kano Scientific Instrument Co., Ltd.
#2610,51 Wulihe Street Heping District, Shenyang City, PRC
TEL: 86-24-23845309
FAX: 86-24-23898417
URL: http://www.kanomax.com.cn/
E-Mail: [email protected]