TABmaster Model 6715 Instruction Manual Be sure to read this manual thoroughly before using the instrument , fully understand and pay attention to each cautions mentioned. Please well-keeping this manual for long time service reference. 01003 14.10 CONTENTS Product Configuration..................................................................................................................... 3 Caution........................................................................................................................................... 5 1. Introduction ................................................................................................................................ 7 1.1. Features............................................................................................................................. 7 1.2. Specifications ..................................................................................................................... 7 2. Outlook & Structure .................................................................................................................... 8 2.1. Base structure .................................................................................................................... 8 2.2. Micromanometer ............................................................................................................... 9 3. Settubg up................................................................................................................................... 9 3.1. Capture Hood .................................................................................................................... 9 3.2. Velocity Grid.....................................................................................................................10 3.3. Pitot tube .......................................................................................................................... 11 3.4. Micromanometer .............................................................................................................. 11 3.5. Shoulder Strap.................................................................................................................. 11 4. Operating Instruction .................................................................................................................12 4.1. Power supply ....................................................................................................................12 4.2. Start On / Power Off .........................................................................................................12 4.3. Keypad operation..............................................................................................................13 5. Function test...............................................................................................................................14 5.1. User Interface ...................................................................................................................14 5.2. Single Mode ......................................................................................................................15 5.3. Average Mode ...................................................................................................................15 5.4. Back Pressure Mode ..........................................................................................................15 6. Menu setting...............................................................................................................................16 6.1. General setting..................................................................................................................17 6.1.1. Date ........................................................................................................................17 6.1.2. Time .......................................................................................................................17 6.1.3. Auto Off..................................................................................................................17 6.1.4. Backlighting............................................................................................................18 6.1.5. Communication.......................................................................................................18 6.2. Test setting........................................................................................................................19 1 6.2.1. Tools .......................................................................................................................19 6.2.2. ID application .........................................................................................................20 6.2.3. Test Mode ...............................................................................................................20 6.2.5. Data record .............................................................................................................21 6.2.6. Standard/Actual test ................................................................................................21 6.2.7. Compensation factor ...............................................................................................22 7 Error and Troubleshooting...........................................................................................................23 8 Warranty and Service ..................................................................................................................24 8.1. Product Warranty.............................................................................................................24 8.2. After service......................................................................................................................24 2 Product Configuration. 6715 Standard: Item. Qt’y Micromanometer Model 6700 Instrument Base 1 Fabric Hood: 2ft×2ft 1 Carrying case 1 Portable handle 1 Frames 1 Poles 4 Communication cable 1 Calibration certificate 1 CD-Rom(Manual and software inside) 1 Quick-Guide 1 1 6715 Optional Parts: Item. Specifications Spare hood 2x2ft Spare hood 2x4ft Spare hood 1x4ft Spare hood 3x2ft Spare hood 3x3ft Spare hood 500x500mm Poles Up to 3.4m with capture hood Capture Hood Stand Communication cable Printer AC adapter DC5V International plug adapter Carrying case Velocity Grid Pitot tube (2.3 x 200mm) Pitot tube (4 x 300mm) Pitot tube (8 x 500mm) Pressure tubing 2*250cm 3 6700 Standard: Item. Qt’y Micromanometer Model 6700 1 Carrying case 1 Pressure tubing 2 Communication cable 1 Calibration certificate 1 CD-Rom(Manual and software inside) 1 Quick-Guide 1 6700 Optional Parts: Item. Specifications Velocity Grid Pitot tube (2.3 x 200mm) Pitot tube (4 x 300mm) Pitot tube (8 x 500mm) Pressure tubing 2*250cm Shoulder Strap Printer AC adapter DC5V International plug adapter Communication cable 4 Caution. The symbols for warning mentioned in this manual are defined below: 〔symbols classifications〕 Danger: To Prevent Serious Injury or Death Wa rnings in this classifi cation indi cate a danger tha t ma y resul t in serious injury or dea th if not observed . Caution: To Prevent Damage to the Product Wa rnings in this classifica tion indi ca te a risk of damage to the product tha t ma y void the product wa rranty if not observed. 〔 Description of Symbols〕 △ This s ymbol indi ca tes a condi tion tha t requi res caution (including danger). The subject of ea ch cauti on is illustra ted inside the triangle . This s ymbol indica tes a prohibi tion. Do not take the prohibi ted a ction shown inside or nea r this s ymbol . ● This symbol indicates a mandatory action. A specific action is given near the symbol. WARNING ○ Never bring the fabri c hood to a flammable gas a tmosphere. Heated forbidden Disassemble … otherwise, the hea t ma y cause a fi re or explosion. ○ Do not disassembl y or refi t the instrument. … otherwise, ma y cause the electri c shock or a fi re. ○ Using properl y under the instruction manual. … otherwise, ma y cause sensor da maged or an electri c shock even a fire. ○ If abnormal smells, noises or s moke occur, or if liquid enters the ins trument, pull out prohibition Using properly the AC adapter and remove the batteries immedia tel y. Then send i t to the maintena nce Dept. of KANOMAX for after servi ce. Using properly … or, there is possible of an electri c shock or a fi re or instrument malfunction. ○ Do not expose the fabri c hood, base and the ins trument noumenon in the rain. … Forbidden otherwise, ma y cause an electri c shock, an fire and an person injure. 5 CAUTION Using properly ○ Alwa ys unplug when the instrument not in use. … Failure to do so ma y cause an electri c shock, an fire or ci rcui t da mage. ○ Remove the ba tteries when s tori ng the instrument for a l ong period. Do not lea ve the exhaused batteries in the ba ttery compa rement and exchange the ba ttereis on time. Using properly Using properly … Failure to do so ma y cause the batteries leakage and the ins trument dama ge. ○ Ma tching the correct AC adapter outwa rd as reqes ted. … or ma y ca use the ins trument dama ge. ○ Do not wipe the ins trument wi th a vola tile sol vent. … the body ma y deform or deteri ora te. Use a soft dry cl oth to remove stains . If stains persist, soak the cloth in a neutral detergent a nd wipe the i nstrument with the soft Forbidden cloth. Never use vola tile sol vents such as thinner or benzene . ○ Do not use or lea ve the ins trument in a high temperature, high humidi ty or dus ty envi ronment. Do not lea ve the instrument under di rect sunlight. … Forbidden otherwise, the instrument ma y not function properl y out of the speci fied opera ting condi tions or the inside components damaged. ○ Never dropping the uni t or pla cing hea vy objects on i t … It ma y cause damage or malfunction to the ins trument Forbidden 6 1. Introduction TABmaster Model 6715 is a kind of intelligent test instrument with multi functional of airflow test, velocity test and micro-Differential pressure test. It’s widely used in air flow and velocity testing of air - conditioning, HAVC system and other places, especially for the high precision micro differential pressure test. 1.1. Features 3.5 inch true color LCD. Available measuring the air flow, velocity, temperature and humidity at the same time. Two kinds of tests are available of in flowing and exhaust flowing. Back pressure compensation. Ultra-large Storage capacity: 8000 records Blue tooth communication makes remote monitoring and data transferring available. Light weight, compact configuration for easy carrying. Data printing or transferring to the computer. 1.2. Specifications Items Specifications Test range 40~4300 m3 /h Accuracy ±3% of readings ± 8m3 /h(>85m3 /h) Resolution Test range 1 m /h 0.15~40 m/s(Pitot Tube)、0.15~15 m/s(Velocity Grid) Accuracy ±3% of readings ±0.05m/s(>0.25m/s) Resolution 0.01m/s Test range -2500~2500 Pa Accuracy ±0.25% of readings ±1Pa Resolution 0.001 Pa Test range 0~60℃ Accuracy ±0.5℃ Resolution 0.1℃ Test range 0~100%RH Accuracy ±3%RH(10~90%RH) Resolution 0.1%RH Test range 70~130 kPa Accuracy ±2% of readings Resolution 0.1 kPa Air flow Air velocity Differential pressure Temperature Humidity Absolute pressure 3 Operation Temp. 0~60℃(non condensing ) Storage Temp. -20~70℃(non condensing) Power Source 4 pcs of AA-size buttery ( approx. 9hrs available)or DC5V Adapter Weight 3.6kg approx. 7 2. Outlook & Structure Frame Poles Pi vot Wi ndow Fabri c Hood Ins trument Base Mi cromanometer 2.1. Base structure 1.Outlook Potable handle Mi cromanometer Ba ck pressure ON/OFF Adjus t handle Base buttom Test handle 2.Internal view 3.Grid Ba ck pressure plate Testing Poles point Grid 8 2.2. Micromanometer Displa y LCD Keypad Cover lock Front view Power on/off Ai r port (+) Ba ttery Compa rtment Cover Ba ck Mini USB Port Ai r port (-) Top view Bottom view 3. Settubg up 3.1. Capture Hood 1.Fabric Hood & basement 、 (1) (2) (3) (4) Note: 1) Make sure the elastic band of the fabric hood is placed exactly as shown (Figure(3)) to ensure a good fit. The elastic band must lineup with the top lip of the base as shown. If you don’t line it up correctly, the hood might slide off the base when you insert the poles. 2) Use the 4 positioning holes on the base stitching as a guide to ensure the hood fully wraps around the base.. 2.Frame Poles 9 Note: The poles always cross in an “X” shape when assembling. To remove the poles, simply reverse the steps. 3.Potable handle ① ② Note: Release the poles and portable handle when packing in the carring case to avoid case damaged. 4.Micromanometer & basement (+) Note: 1)Correct install the micromanometer to the base with the same S/N No. 2)Do not cross- insert the Air pines just refer to the figure as above. 3.2. Velocity Grid Air velocity testing can be achieved when micromanometer work together with the velocity Grid. 10 (-) Grid Ha ndle (+)(-) Note: Mounting angle between the Grid and handle can be adjusted as request. 3.3. Pitot tube Air flow and velocity testing can be achieved when micromanometer work together with Pitot tube. Sta ti c pressure port Testing point (+)(-) 3.4. Micromanometer Differential pressure testing can be achieved by using the micromanometer. Device under test (+)(-) 3.5. Shoulder Strap When testing by Velocity Grid、Pitot tube、Micromanometer as the tool, for convenient view and easy operation, the shoulder strap can be fit for using. 11 4. Operating Instruction 4.1. Power supply 1.Power by AC adapter. AC adapter will be as the priority power supply when the AC adapter and batteries are all available using. The specification of the AC adapter is: 1)AC adapter for the master I/P:AC 110-240V 50/60HZ O/P:DC 5V/2A。 2)AC adapter for Capture Hood 2.Power by battery 4 AA-size batteries can be used for a power supply. Press the compartment cover lock (refer to figure indicating ①/②), and then slide the cover off to open the battery compartment。 Put 4 AA-size batteries in and make certain the batteries are correctly oriented. New alkaline battery or rechargeable Ni-MH battery can be used. Never mix battery types, or battery leakage or damage to the instrument may occur. Replace the compartment cover (refer to figure ③). The compartment cover will be automatically locked. ① ③ ② When power is supplied with batteries, the current charge value will be displayed on the upper of the LCD. When the batteries run out of power, the instrument will turn off. Power off Note: 1) Do not test with low battery power. 2) Do not mixing use full power battery with low power ones for ensure testing well. 3) Change the batteries in time when power shows low for ensure testing well. 4.2. Start On / Power Off 12 POWER 2014 / 03 / 20 13 : 10 ID: Ready Atmos: 20.5 START ℃ 01 m3/h 99.0 kPa 30.7 %RH SAVE MENU Cycle: 001 Mode: Single 1. Start On Press button【POWER】for 2 seconds for start On, displaying “ KANOMAX” then enter into the interface. 2. Power Off Press【POWER】for 2 seconds, shut down and power off. 4.3. Keypad operation Keypad panel includes control buttons, back-pressure switch and LCD adjusting keys. 1. Control buttons: UP/SAVE SET/MENU/OK START/STOP/ BACK/EXIT/ESC DOWN START/STOP SAVE UP:Value increasing or Cursors upward moving. SAVE:Save the current test results SET:Store changes or enter into the selected option’s next level interface MENU:On the main screen holding this down for 2 seconds will enter into the main “MENU” OK:In the “General Setting ”, pressing for 2 seconds will save the date or time ; While in the “Record Processing”, pressing for 2 seconds will delete saved data. START:Begin a measurement in main menu STOP:Stop a measurement in main menu BACK:Cancel or end an operation or return to the previous screen EXIT:Return to the main menu ESC:Stop printing when printing DOWN::Value decreasing or Cursors downward moving 2. Back pressure switch for on/off Note : 1) If you are not in the back pressure mode, shut down the back pressure plate and lock the switch to avoid testing errors. 2) If the airflow is greater than 1500m3 /h (883CFM), testing in back-pressure Mode is recommended according to testing procedures. 13 testing Ba ck pressure On Ba ck pressure Off 3.LCD adjusting Note : 1)Please switching the handle slow gently during LCD adjusting. 2)Stop turning when reach to the bound, for avoiding over turning and handle falling down. 5. Function test Besides the airflow test, if along with other optional products, test air velocity and micro -differential pressure is available. 5.1. User Interface Testing information, parameter settings and the testing conditions will be displayed on the main interface. J A 2014 / 03 / 20 Ready Atmos: E I ID: B C D 13 : 10 20.5 ℃ START m /h 99.0 30.7 SAVE 01 H 001 G 3 kPa %RH MENU Cycle: Mode: Single F A. Date and time —— real-time display the current date and time B. Testing data display —— airflow 、air velocity 、differential pressure and etc. C. Tools icon —— working tools display D. Testing condition —— temperature 、humidity or absolute pressure displaying according to the 14 working tools. E. Keypad —— current status indicating and the grey state is not available. F. Testing mode —— display the current testing mode G. Cycle—— recorded Cycle quantity H. ID—— current ID quantity Power supply —— AC adapter or batteries Blue tooth status —— when blue tooth working, the icon display or no icon display with closed. I. J. 5.2. Single Mode 2014 / 03 / 20 2014 / 03 / 20 13 : 10 2014 / 03 / 20 13 : 10 ID: ID: Ready Atmos: 20.5 ℃ 01 m3/h 99.0 kPa 30.7 %RH SAVE START MENU m3/h Cycle: 001S TART Atmos: 20.5 Mode: ℃ Atmos: 001 20.5 Mode: ℃ 99.0 kPa 30.7 %RH SAVE START Single MENU 2. Testing 1. Ready for testing 01 m3/h Cycle: 99.0 kPa 30.7 %RH SAVE STOP Single ID: 32 01 Waiting... 13 : 10 Cycle: 001 Mode: Single MENU 3. tes t output 待测状态 Note: 1) START: Left-button for the Micromanometer or instrument base 2) After testing start for about 8s with stably measuring,output displaying the test data and testing wind direction. 3) Testing stop when finish outputting. 4) Press SAVE for data record with adding 1 to the Cycle value. 5) Same testing method with the capture hood when using the Velocity Grid、Pitot、Micromanometer. 5.3. Average Mode 2014 / 03 / 20 13 : 10 2014 / 03 / 20 Ready Atmos: 20.5 ℃ 99.0 kPa 30.7 %RH SAVE START ID: 01 m3/h MENU 2014 / 03 / 20 13 : 10 ID: Cycle: 001 Mode: Avg Waiting... S TART Atmos: 20.5 STOP 1.Ready for tes ting ℃ m3/h 99.0 kPa 30.7 %RH SAVE 32 01 MENU Cycle: Atmos: 001 20.5 Mode: Avg ℃ STOP ID: m3/h 99.0 kPa 30.7 %RH SAVE MENU Cycle: 001 Mode: Avg 13 : 10 31 01 3. test output 2. Testing 2014 / 03 / 20 13 : 10 STOP Atmos: 20.5 STOP ℃ ID: 01 m3/h 99.0 kPa 30.7 %RH SAVE Cycle: 001 Mode: MENU 4. testing stop Note: 1) START: Left-button for the Micromanometer or instrument base. 2) After testing start for about 8s with stably measuring , output displaying the test data for the first time. 3) Go on the testing with frequency of 1s for data updating. 4) The continuously outputting is as the average data and be related with the “AvgTime” set by user. More larger of the value of“AvgTime” will get more stable of the testing data. 5) If auto-save function On, testing data will be recorded automatically according to the setting “AutoSave” and value of “Cycle” will be added automatically. 6) Press “STOP”, testing stop. And “STOP” will be as the Left-button for the Micromanometer or instrument base. 7) Same testing method with the capture hood when using the Velocity Grid、Pitot、Micromanometer. 5.4. Back Pressure Mode 15 Avg In order to reduce the measure error of the pressure loss,which causing from the hood to the system and get the more real air flow, we suggest testing under the Back Pressure Mode when air flow more than 1500 m3/h. 2014 / 03 / 20 2014 / 03 / 20 13 : 10 Atmos: 20.5 ℃ m3/h SAVE START Cycle: 99.0 kPa 30.7 %RH ID: 01 Waiting... S TART Atmos: 001 20.5 Mode: STOP B.P MENU 1.Ready for tes ting 2014 / 03 / 20 ℃ m3/h 99.0 kPa 30.7 %RH SAVE 20.5 ℃ 20.5 Mode: START B.P MENU 2014 / 03 / 20 m3/h SAVE Cycle: 001 Ready S TART B.P ℃ 99.0 kPa 30.7 %RH SAVE 001 Mode: B.P MENU 4. s wi tch on Back-Pressure Pla te 2014 / 03 / 20 13 : 10 ID: 20.5 ℃ 01 SAVE START Ready Cycle: 99.0 kPa 30.7 %RH MENU B.P Cycle: ID: Atmos: Mode: 01 m3/h 13 : 10 m3/h 001 13 : 10 5. testing ready 2000 MENU Cycle: 3. Ba ck-pressure On promoting 99.0 kPa 30.7 %RH SAVE START 6. testing 2014 / 03 / 20 Atmos: 20.5 Mode: MENU ℃ 01 m3/h ID: 01 99.0 kPa 30.7 %RH STOP Atmos: 001 ID: Atmos: Open Flap ! Cycle: 2. Testing 13 : 10 Waiting... 13 : 10 ID: 01 Ready 2014 / 03 / 20 13 : 10 ID: Atmos: 001 20.5 Mode: 8. shut off the pla te 99.0 kPa 30.7 %RH SAVE START B.P 7. test output ℃ 01 m3/h Cycle: 001 Mode: MENU B.P 9. testing ready Note: 1) START: Left-button for the Micromanometer or instrument base. 2) After testing start for about 8s , indicating “Open Flap”. It’s time for switching on the Back-Pressure Plate as needed. 3) When Back-Pressure Plate opened On, tip of “Open Flap” disappear. 4) Press START for about 8s, testing stop, real airflow outputting with back pressure compensation. 5) Press SAVE for testing data record and the meanwhile, value Cycle added 1. 6) When select Velocity Grid、Pitot tube、Micromanometer for testing, Back-Pressure compensation will be not available. 6. Menu setting when stop for ready, press 2014 / 03 / 20 for 2s for enter into the menu. MENU 13 : 10 ID: Ready Atmos: 20.5 START ℃ 99.0 30.7 SAVE UP 01 m3/h kPa %RH MENU 2s General Setting DOWN Cycle: 001 Mode: Test Setting Avg 1)Basi c setting SET 2)Test setting OK 3)Working tool displayi ng below EXIT 16 (1)2 opti onal settings : 6.1. General setting UP General Setting DOWN SET Test Setting (1)Basic setting: 1)Date 2)Time 3)Auto Shut 4)Backlight 5)Communicate General Setting MENU 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate UP 2014 / 03 / 20 13 : 10 Off High DOWN SET OK OK EXIT BACK 6.1.1. Date General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High General Setting UP 1. 2. 3. 4. 5. DOWN SET Date Time Auto Shut Backlight Communicate UP 2014 / 04 / 01 13 : 10 Off High DOWN (1) press or for data modify. (2)press , for sele cting Year/Month/day. (3)Press for 2s for save settings. SET OK OK BACK BACK (4)Press for quit. 2s General Setting General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 20 14 / 03 / 20 13 : 10 Off High UP 1. 2. 3. 4. 5. DOWN SET Date Time Auto Shut Backlight Communicate UP 2014 / 04 / 01 13 : 10 Off High DOWN SET OK OK BACK BACK 6.1.2. Time General Setting General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High UP DOWN SET 1. 2. 3. 4. 5. Data Time Auto Shut Backlight Communicate 2014 / 03 / 20 15 : 15 Off High UP (1)Press DOWN (2)Press SET or for data modify. for hour/minute selection. (3)Press for 2s for save settings. OK OK (4)Press BACK for quit. BACK 2s General Setting General Setting 1. 2. 3. 4. 5. Data Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High UP DOWN SET 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 15 : 15 Off High 2s UP DOWN 或 (2)按 键,时/分选项循环移动。 (3)长按 键进行数值更改。 键 2s,保存设置。 SET OK OK (1)按 (4)按 键,退出设置。 BACK BACK 6.1.3. Auto Off When instrument not in use, it will be turn off automatically according to Auto-Off time setting to avoid power waste. 17 General Setting General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High UP DOWN SET 1. 2. 3. 4. 5. Data Time Auto Shut Backlight Communicate OK 2014 / 03 / 20 13 : 10 Off 10 min 20 min 30 min 60 min General Setting Data Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off 10 min 20 min 30 min 60 min (1)Press or for options cha nge. (2)Press for save settings . (3)Press for quit. DOWN SET OK BACK BACK 1. 2. 3. 4. 5. UP (3)按 键,退出设置。 General Setting UP DOWN SET 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 10 min High UP DOWN SET OK OK BACK BACK 6.1.4. Backlighting Adjust the LCD lighting according to the environmental brightness for the best viewing. And meanwhile, the lower the brightness, the less battery power will be needed. General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High General Setting UP DOWN SET 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate OK 2014 / 03 / 20 13 : 10 Off Low Normal High BACK Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off Low Normal High (1)Press or for options cha nge. SET OK (2)Press for save settings . (3)Press for quit. BACK General Setting General Setting 1. 2. 3. 4. 5. UP DOWN UP DOWN SET 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off Low UP DOWN SET OK OK BACK BACK 6.1.5. Communication Communicate with PC, printer and Bluetooth are available. Data transfer or remote monitoring is available by selecting communicating way. Note: 1)PC communication means to save the testing record to the computer. And the communication cable and software reserved for data-fetching are necessary for using together. Refer to the << Manuel for Data fetching Software>> . 2)For printing out the testing record, the optional printer and cables for special are necessary. Printer baud rate is set to 19200 bps and Do not change it. Refer to the << Manuel for RD series Mini printer >> . 3)Bluetooth make the remote control and data monitoring available by Hand phone. And our APP software is necessary for using together. Refer to the << Manuel for TAB Mobile>>. 4)Shut off the switch when not use the Bluetooth communication for improving battery life. 18 General Setting 1. 2. 3. 4. 5. Date Time Auto Shut Backlight Communicate 2014 / 03 / 20 13 : 10 Off High UP DOWN SET OK BACK Communicate Computer UP 1. Computer 2. Printer 3. Bluetooth Off UP Comfirm the Connection DOWN Waiting... SET SET OK OK BACK BACK Print Communicate UP 1. Computer 2. Printer 3. Bluetooth DOWN Off UP 1. Print By IDs 2. Print By Cycles DOWN DOWN SET SET OK OK BACK BACK Communicate Communicate UP 1. Computer 2. Printer 3. Bluetooth Off UP 1. Computer 2. Printer 3. Bluetooth DOWN DOWN On SET SET OK OK BACK BACK 5)If other settings need to be changed when Bluetooth successful communication, you need to shutdown Bluetooth firstly then enter the menu to change other settings. 2014 / 03 / 20 Just as below shown: 2014 / 03 / 20 13 : 10 13 : 10 ID: ID: 32 Atmos: 20.5 ℃ 99.0 kPa 30.7 %RH SAVE START 32 01 m3/h OFF Cycle: 2s 001 Atmos: 20.5 Mode: ℃ Avg 99.0 kPa 30.7 %RH SAVE START 01 m3/h MENU Cycle: 001 Mode: Avg 6.2. Test setting Test Setting MENU UP General Setting DOWN SET Test Setting OK 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor EXIT 6.2.1. Tools 19 Test settings: UP RunAvg DOWN SET Act 1.000 OK BACK 1)Select Tool 2)Test ID 3)Test Mode 4)Unit 5)Data Record 6)Standard/Actual testing 7)Compensation factor The TABmaster model 6715 is an instrument for airflow, air temperature, and relative humidity measurements. The optional accessories (Velocity Grid, Pitot tube, and Micromanometer) expand the parameters that the instrument can measure. Refer to the Chapter 3 and 5 for details. Test Setting 1. 2. 3. 4. 5. 6. 7. Select Tool UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN SET Act 1.000 (1)Press SET 3. Pitot OK OK BACK or for options cha nge. DOWN 2. Velocity Grid 4. Pressure P (2)Press for save settings . (3)Press for quit. BACK Test Setting Select Tool UP 1. Capture Hood DOWN 2. Velocity Grid SET 3. Pitot OK 4. Pressure UP 1. Capture Hood P BACK 1. 2. 3. 4. 5. 6. 7. Tools TABmaster Velocity Grid Pitot tube Micromanomete r UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN SET Act 1.000 OK Test item Air flow / Temperature / RH Air velocity velocity Micro-differe ntial pressure BACK 6.2.2. ID application Test Setting 1. 2. 3. 4. 5. 6. 7. Test ID UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN 01 1. Select ID 2. Add New ID No SET Act 1.000 Total ID: OK 20 UP (1) Test ID is up to 20. DOWN (2) Set different Test ID for the di fferent tool . SET (3) 100 data records can be stored in a single OK BACK ID BACK 6.2.3. Test Mode Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor Single DOWN SET Act 1.000 1. Select Tool 2. Test ID 3. Test Mode Avg Time: Auto Save: Select Tool Test ID Test Mode Unit Data Record Std/Act K factor OK DOWN SET OK BACK Select Tool Test ID Test Mode Unit Data Record Std/Act K factor UP Single RunAvg B.Prees Act 1.000 DOWN SET OK BACK 1. 2. 3. 4. 5. 6. 7. RunAvg 03 Sec Off 10 Sec 20 Sec 30 Sec 60 Sec DOWN SET OK BACK UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN SET Act 1.000 20 the more s table the testing value will be as spikes in ai rflow will be avera ged out over time. (2)“Auto Sa ve” is a time interval for UP Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. SET Test Setting 1. Select Tool 2. Test ID 3. Test Mode Avg Time: Auto Save: testi ng; the longer the ti me peri od, DOWN BACK BACK UP Single RunAvg B.Prees Act 1.000 RunAvg 03 Sec Off OK Test Setting 1. 2. 3. 4. 5. 6. 7. (1)”Avg Ti me” is as a peri od for UP OK BACK automa tic da ta recording during testing. 6.2.4. Units Unit Test Setting 1. 2. 3. 4. 5. 6. 7. UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg m3/h CFM l/s lbs 1. Airflow 2. Atoms 3. Temperature DOWN SET Act 1.000 UP (1)Press or for options cha nge. (2)Press for save settings . (3)Press for quit. DOWN SET OK OK BACK BACK Unit Unit CFM kPa ℃ 1. Airflow 2. Atoms 3. Temperature UP m3/h kPa ℃ 1. Airflow 2. Atoms 3. Temperature DOWN UP DOWN SET SET OK OK BACK BACK 6.2.5. Data record Test Setting 1. 2. 3. 4. 5. 6. 7. UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN SET OK Act 1.000 BACK Test ID: 01 Data Record Cycle: Total: 20 UP UP 1. Display the Record 2. Delete the Record Max: DOWN m3/h 0 DOWN Min : 0 m3/h Avg: 0 m3/h SET SET OK OK Press [SET] See Cycle Data BACK Data Record 01 Total: 01 AirFlow: Atmos : Temp: Humidity: Std/Act: Time: 0 m3/h 101.3 kPa 21.1 ℃ 35.8 %RH Std 2014 / 03 / 18 13 : 10 : 18 BACK UP DOWN SET OK BACK Delete 1. Display the Record 2. Delete the Record UP DOWN SET OK UP No 1. Delete All 2. Delete IDs Select ID: 01 3. Delete Cycles Select ID: 01 Select Cycle: 001 DOWN No SET No OK BACK BACK Note: 1) Browsing or deleting test data in current testing tools is available for allowed. 2) Data exporting by communication function and deleting the non-valid data in time for the effective storage space. 3) Pressing for 2 seconds will delete saved data. 6.2.6. Standard/Actual test Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor UP RunAvg DOWN SET Act 1.000 OK BACK 1. 2. 3. 4. 5. 6. 7. Test Setting UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg DOWN SET Act Std 21 OK BACK 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor UP RunAvg DOWN SET Std 1.000 OK BACK Note: 1) Standard Test (Std): in the condition of atmosphere 101.3kPa and temperature 21.1℃. 2) Actual Test(Act): in actual condition with the compensation for the atmosphere and temperature. 3) No Std/Act selection when in Micromanometer testing. 4) When doing actual testing under Velocity Matrix and pitot tube, manually input the current temperature is needed for the compensation. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor Temperature Test Setting Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. 8. Refer to the figures as below: UP RunAvg DOWN SET Act 1.000 23.5 ℃ OK BACK 1. 2. 3. 4. 5. 6. 7. 8. UP Select Tool Test ID Test Mode Unit Data Record Std/Act K factor Temperature RunAvg 1. 2. 3. 4. 5. 6. 7. 8. DOWN SET Act 1.000 25.0 ℃ OK BACK Select Tool Test ID Test Mode Unit Data Record Std/Act K factor Temperature UP RunAvg DOWN SET Act 1.000 25.0 ℃ OK BACK 6.2.7. Compensation factor Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor UP RunAvg DOWN SET Act 1.000 OK BACK 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor 1. 2. 3. 4. 5. 6. 7. Select Tool Test ID Test Mode Unit Data Record Std/Act K factor Select Tool Test ID Test Mode Unit Data Record Std/Act K factor RunAvg SET Act 1.010 (1)Press or for options cha nge. (2)Press for save settings . (3)Press for quit. DOWN OK BACK Test Setting Test Setting 1. 2. 3. 4. 5. 6. 7. UP UP RunAvg DOWN SET Act 1.000 OK BACK UP RunAvg DOWN SET Act 1.010 OK BACK Note: 1) Under Capture Hood and Velocity Grid testing, K factor is used for testing data compensation in order to get more accuracy result. And the testing range will be 0.500~1.500. Note: K factor will affect the accuracy of measurement, so, it’s necessary for having the test bench for standard reference and using with caution. For example: If the Capture Hood is as the selected testing tool, testing value by Model 6715 is 1000m3 /h, the standard airflow is 1020m3 /h,at this point, K factor= standard value/testing value =1.020,input this K factor to correct the accuracy of the measurement by Model 6715. 2) Under Pitot tube testing, K factor is the factory standard coefficient and each pitot with its own independent factor. 3) No K factor setting under the micromanometer testing. 22 7 Error and Troubleshooting Symptom No display when power On Possible causes Corrective action incorrect specification of the AC Check and refer to Chapter4.1 Adapter in Manuel Check and refer to Chapter4.1 Battery installation error in Manuel Low or dead battery power Display “Connect Error” Display “DATA Error” Press “START” but no response Testing record can not be saved New ID can not be added Replace the batteries Connection cable loss with the base Back-Pressure mode using incorrect Reseat the connect cable Refer to Chapter 5.4 in Manuel Low battery charge Replace new batteries Back Pressure Plate opened On Shut off the plate Over-limit Cycle current ID Add new ID or delete some data quantity in ID over-limit Delete some ID Current ID is without “Cycle” Using the current ID Unmatched printer Printing unreadable code Wrong baud rate setting 23 Using our special optional printer supplied by us. Reset referring to the Printer Manuel 8 Warranty and Service 8.1. Product Warranty The limited warranty set forth below is given by KANOMAX GROUP COMPANIES with respect to the KANOMAX brand capture hood and other accessories (hereafter referred to as “PRODUCT”) purchased directly from KANOMAX GROUP COMPANIES or from an authorized distributor. Your PRODUCT, when delivered to you in new condition in its original container, is warranted against defects in materials or workmanship as follows: for a period of one (1) year from the date of original purchase, defective parts or a defective PRODUCT returned to KANOMAX GROUP COMPANIES, as applicable, and proven to be defective upon inspection, will be exchanged for a new or comparable rebuilt parts, or a refurbished PRODUCT as determined by KANOMAX GROUP COMPANIES. Warranty for such replacements s hall not extend the original warranty period of the defective PRODUCT. This limited warranty covers all defects encountered in normal use of the PRODUCT, and does not apply in the following cases: (1) Use of parts or supplies other than the PRODUCT sold by KANOMAX GROUP COMPANIES, which cause damage to the PRODUCT or cause abnormally frequent service calls or service problems. (2) If any PRODUCT has its serial number or date altered or removed. (3) Loss of damage to the PRODUCT due to abuse, mishandling, alternation, improper packaging by the owner, accident, natural disaster, electrical current fluctuations, failure to follow operation, maintenance or environmental instructions prescribed in the PRODUCT's operation manual provided by KANOMAX GROUP COMPANIES, or service performed by other than KANOMAX GROUP COMPANIES. NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIES TO THE PRODUCT AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCT SHALL BIND KANOMAX GROUP COMPANIES. KANOMAX GROUP COMPANIES SHALL NOT BE LIABLE FOR LOSS OF STORAGE CHARGES, LOSS OR CORRUPTION OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE OR MISUSE OF, OR INABILITY TO USE, THE PRODUCT, REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF KANOMAX GROUP COMPANIES HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST KANOMAX GROUP COMPANIES BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY KANOMAX GROUP COMPANIES AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, THE OWNER ASSUMES ALL RISK AND LIABILITY FOR LOSS, DAMAGE OF, OR INJURY TO THE OWNER AND THE OWNER'S PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OF, OR INABILITY TO USE, THE PRODUCT NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF KANOMAX G ROUP COMPANIES. THIS LIMITED WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN THE ORIGINAL PURCHASER OF THE PRODUCT, OR THE PERSON FOR WHOM IT WAS PURCHASED AS A GIFT, AND STATES THE PURCHASER'S EXCLUSIVE REMEDY. 8.2. After service When you have a problem with your instrument, please check out the “Common Trouble Shooting” section first. If that does not help, please contact your local distributor, or contacts on the last page. During the warranty period, we will repair at no charge a product that proves to be defective due to material or workmanship under normal use. (See Section 14.1 Warranty) All return shipping charges are the responsibility of the customer. 24 Repair after warranty expiration: Upon request, we will repair the instrument at the customer’s expense, if the instrument’s performance is found to be recoverable by providing the repair. Replacement parts are available for a minimum period of five (5) years after termination of production. This storage period of replacement parts is considered as the period during which we can provide repair service. For further information, please contact your local distributor, or contacts on the last page. When making an inquiry, please provide the following information : * PRODUCT NAME ---------* Model No. ---------* Serial No. ---------* Description of the problem : ---------* Data of Purchase: Day, Month and Year 25 Kanomax Group Companies ■ Americas, Europe, Mid-East, Africa, Oceania KANOMAX US A, INC. 219 US Highway. 206, Andover, New Jers ey 07821 TEL: 1-800-247-8887(USA ) / 1-973-786-6386 FAX: 1-973-786-7586 URL: www.kanomax -usa.com E-Mail: [email protected] ■ Japan & Asia KANOMAX JAPAN, INC. 2-1 Shimizu Suit a City, Osaka Japan 565 -0805 TEL: 81-6-6877-0183 FAX: 81-6-6879-2080 URL: www.kanomax.co.jp E-Mail: [email protected] ■ China Shenyang Kano Scientific Instrument Co., Ltd. #2610,51 Wulihe Street Heping District, Shenyang City, PRC TEL: 86-24-23845309 FAX: 86-24-23898417 URL: http://www.kanomax.com.cn/ E-Mail: [email protected]
© Copyright 2025 Paperzz