7235.09_515_A400.dwg March 31, 2016, 4:00 pm REFLECTED CEILING PLAN NOTES, TYPICAL FOR AND APPLICABLE TO ALL LOCATIONS SEE SPECIFICATIONS BOOK FOR MORE INFORMATION. 2. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE GENERAL CONTRACTOR SHALL PROVIDE “CHALK LINE” LAYOUT OF THE FOLLOWING ITEMS FOR THE ARCHITECT'S ON-SITE APPROVAL: PARTITION LAYOUT, WITH DOOR AND DOOR SWING LOCATIONS; OUTLET AND TELEDATA LOCATIONS; SWITCH AND SWITCH BANK LOCATIONS; TRANSFORMER, PANEL, AND SUPPLEMENTAL MECHANICAL EQUIPMENT LOCATIONS; CEILING SOFFIT LOCATIONS; VAV BOXES AND LIGHTING LAYOUTS FOR RECEPTION AREAS, CONFERENCE ROOMS, AND MAJOR PUBLIC SPACES. 3. REFER TO ARCHITECTURAL RCP FOR EXACT QUANTITY AND LOCATION OF LIGHT FIXTURES, DIMMING REQUIREMENTS, ETC. ARCHITECTURAL DRAWINGS GOVERN. 4. GENERAL CONTRACTOR & SUBCONTRACTOR TO THOROUGHLY REVIEW ARCHITECTURAL AND ENGINEERING DOCUMENTS AND TO NOTIFY ARCHITECT AND ENGINEER IN WRITING IMMEDIATELY OF DISCREPANCIES FOR RESOLUTION PRIOR TO SUBMISSION OF BID AND TO PROCEEDING WITH WORK. 5. GENERAL CONTRACTOR TO REVIEW COORDINATION OF MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER IN WRITING IMMEDIATELY OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING WITH WORK. 6. GENERAL CONTRACTOR AND SUBCONTRACTORS TO THOROUGHLY VERIFY AND COORDINATE ALL CONDITIONS IN FIELD INCLUDING ELECTRICAL PANEL CAPACITY, LOCATION AND CLEARANCES AT MECH DUCTS, ELECTRICAL ITEMS, SPRINKLERS AND ASSOCIATED PIPING AND SLAB HEIGHTS. NOTIFY ARCHITECT AND ENGINEER IN WRITING IMMEDIATELY OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING WITH WORK. 7. GENERAL CONTRACTOR TO VERIFY EXTENT OF EXISTING CONSTRUCTION IN FIELD. GC SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY "AS-BUILT" CONDITIONS CONTRARY TO THOSE SHOWN OR INFERRED FROM THE CONSTRUCTION DOCUMENTS, PRIOR TO COMMENCEMENT OF WORK. 8. EXISTING SLAB HEIGHT IS APPROXIMATELY 9'-11" AFF. GENERAL CONTRACTOR TO VERIFY HEIGHT PRIOR TO CONSTRUCTION TO DETERMINE HEIGHT CLEARANCES FOR FIXTURES, CEILING GRID AND ACOUSTICAL CEILING TILES. 9. C EQ. 8'-0" 8'-0" OPEN AREA 518 A A 8'-0" B B 8'-0" B OPEN AREA B 519 F2 REFLECTED CEILING PLAN NOTES, PLAN SPECIFIC H CL B F2 F2 F2 F2 F2 EQ. 4 A801 515 F1 13. ANY DAMAGE TO THE NEW OR EXISTING CONSTRUCTION CAUSED BY THE GENERAL CONTRACTOR'S NEGLIGENCE, INADEQUATE PROTECTION, OR INADEQUATE SECURITY MEASURES DURING CONSTRUCTION ARE TO BE CORRECTED AT THE GENERAL CONTRACTOR'S EXPENSE. 14. FOR ADDITIONAL INFORMATION REGARDING LIGHT FIXTURE SPECIFICATIONS, REFER TO ENGINEERING DRAWINGS. 15. FOR EMERGENCY LIGHTING LOCATIONS REFER TO ENGINEERING DRAWINGS. 16. FOR EXIT SIGN LOCATIONS & SPECIFICATIONS REFER TO ENGINEERING DRAWINGS. ALL EXIT SIGNS ARE TO BE LOCATED IN THE CENTER OF A CEILING TILE, UNLESS NOTED OTHERWISE. 17. REFER TO MEP DRAWINGS FOR LOCATIONS AND TYPES OF EXIT SIGNS, STROBES, AND PULLS. ALL EXIT SIGNS TO BE CENTERED ON HALLWAYS AND/ OR OPENING, UNLESS OTHERWISE NOTED. 18. REFER TO MEP ENGINEERING DOCUMENTS FOR LOCATIONS OF SUPPLY AND RETURN AIR DIFFUSERS, THERMOSTATS, EXIT LIGHTS AND LIFE SAFETY EQUIPMENT. 19. SOUND LINED TRANSFER DUCTS ARE TO BE PROVIDED AT ALL ROOMS WITH SLAB TO SLAB PARTITIONS FOR RETURN AIR. 20. UNLESS NOTED OTHERWISE, REFER TO THE ENGINEERING DRAWINGS FOR LIGHT SWITCHING & LIGHT SWITCH LOCATIONS. 21. GANG ALL ADJACENT SWITCHES UNDER ONE (1) COVERPLATE. IF NEW DIMMERS & SWITCHES ARE ADJACENT THEY ARE TO BE AT EQUAL HEIGHT WITH 1" BETWEEN COVERPLATES. 22. ALL SPRINKLER HEADS, LIGHT FIXTURES, EXIT SIGNS, SPEAKER GRILLES, SMOKE DETECTORS, AND SIMILAR DEVICES SHALL BE LOCATED AT THE CENTER OF CEILING TILE UNLESS NOTED OTHERWISE. 23. ALL NEW DIMENSIONS ARE FROM FINISH SURFACE TO FINISH SURFACE, UNLESS NOTED OTHERWISE. 24. ALL HOLES IN SLABS ARE TO BE FILLED WITH CODE COMPLIANT FILLER, REFER TO MEP SPECS FOR SLAB PENETRATION FIRE-STOP REQUIREMENTS. MAINTAIN THE EXISTING FLOOR AND CEILING SLAB RATINGS AT ALL SLAB PENETRATIONS AS REQUIRED BY UL DESIGN GUIDELINES. 25. GENERAL CONTRACTOR TO PROVIDE AN ALLOWANCE FOR ALL EQUIPMENT AND LABOR REQUIRED FOR THE SYNCHRONIZATION OF FLOOR LOBBY/COMMON CORRIDOR STROBES. 26. PAINT EDGES OF CUT CEILING TILES REMAINING EXPOSED AFTER INSTALLATION. MATCH COLOR OF FACTORY FINISHED PANEL SURFACES USING COATING RECOMMENDED IN WRITING FOR THIS PURPOSE BY THE ACOUSTICAL PANEL MANUFACTURER. 27. CLEAN EXPOSED SURFACES OF ACOUSTICAL PANEL CEILINGS, INCLUDING TRIM, EDGE MOLDINGS, AND SUSPENSION SYSTEM MEMBERS. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTION FOR CLEANING AND TOUCH-UP OF MINOR FINISH DAMAGE. REMOVE AND REPLACE CEILING COMPONENTS THAT CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED. CL E2 B F2 A 6" 3'- C 90° K EQ. E1 B F2 512 A 509 NEW ACT SYSTEM @ 8'-2" AFF, UNLESS NOTED OTHERWISE. SPEC: "ARMSTRONG" 9 ULTIMA (WHITE) 24X24 SQUARE TEGULAR TILE AND ARMSTRONG SUPRAFINE XL 16 " EXPOSED TEE GRID (WHITE) WITH AXIOM TRIM WHERE NOTED. FOR CEILING TRANSITIONS, SEE DETAILS. OFFICE 510 B A OFFICE OFFICE 514 513 A B 4 A801 A 1 A801 B TYP. Spec Suite 540 Presidential Tower 2511 Jefferson Davis Highway Arlington, VA 22202 CONSULTANTS MEP Engineer: DDG Virginia Engineering 3201 Jermantown Rd. #690 Fairfax, VA 22030 Ph: 703.225.0016 Fax: 703.991.3257 SEAL / SIGNATURE NEW ACT SYSTEM @ 8'-2" AFF, UNLESS NOTED OTHERWISE. SPEC: "ARMSTRONG" 9 ULTIMA (WHITE) 24X48 SQUARE TEGULAR TILE AND ARMSTRONG SUPRAFINE XL 16 " EXPOSED TEE GRID (WHITE) WITH AXIOM TRIM WHERE NOTED. FOR CEILING TRANSITIONS, SEE DETAILS. A F2 1'-4" A OFFICE A K E1 B A CLIENT EXPOSED CEILING TO UNDERSIDE OF UPPER SLAB. REMOVE ALL EXISTING UNUSED WIRING, DUCTWORK, ETC. DUCTWORK/HARDWIRE TO BE AT A MINIMUM IN THIS AREA. ALL WIRING TO BE AT A MINIMUM IN THIS AREA, AND BLUNDLED TO THE MINIMUM POSSIBLE CODE-COMPLIANT DIMENSIONS. PATCH ALL SLAB HOLES WITH CODE-COMPLIANT FILLER, SKIM COAT ALL ROUGH AREAS. ALL DUCTWORK, HARDWIRE, ETC. AND SLAB TO BE PAINTED (SEE FINISH SCHEDULE). P1 L1 -- EQ. B 1412 EYE STREET, NW, WASHINGTON, DC 202.621.1000 WWW.OTJ.COM REFLECTED CEILING PLAN LEGEND 8'-0" B B OPEN AREA EQ.EQ. B 3 A801 B 1'-4" 6 A801 EQ. 3'-3" EQ. CL BREAK 1 A801 SIM. 8'-0" CL 508 12. ALL DEVICES AND EQUIPMENT SCHEDULED TO REMAIN ARE TO BE CLEANED, TESTED, SERVICED IF REQUIRED, AND RESTORED TO FULL OPERATING CONDITION. 6'-6" B F1 H A E1 5 A801 EQ. B A B E2 516 B 517 F2 E2 EQ. CONF. F1 OPEN AREA B 500 E3 8'-0" K 8'-0" E1 RECEPTION K 8'-0" 6" 3'- 8'-0" HUDDLE K 503 11. AT ALL MAIN CONFERENCE ROOMS, RECEPTION AREAS, AND OTHER PRIMARY PUBLIC SPACES, GENERAL CONTRACTOR SHALL PAINT PLENUM AREA (SLAB, DUCT, ETC. EXPOSED CEILING ELEMENTS) BLACK A MINIMUM OF 4'-0" IN ALL DIRECTIONS FROM CENTERLINE OF ALL RETURN GRILLES. CONSULT AND COORDINATE FULL SCOPE OF THIS WORK PRIOR TO H 507 8'-0" 6" 3'6" 45° 3'6" LAN/STOR. 8'-0" B 3'- CL CL CL 506 A OFFICE 8'-0" CL LAN 505 GENERAL CONTRACTOR TO ARRANGE AND MODIFY ALL EXISTING NON-VISIBLE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS TO ENSURE ADEQUATE CLEARANCE FOR CEILING INSTALLATION AS SHOWN. NOTIFY ARCHITECT AND ENGINEER IN WRITING IMMEDIATELY OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING WITH WORK. 10. ALL MECHANICAL AND PLUMBING WORK ABOVE CEILING SHALL BE LOCATED TO MINIMIZE REQUIRED ACCESS PANELS IN INACCESSIBLE CEILING AREAS. GENERAL CONTRACTOR SHALL SUBMIT COORDINATED LAYOUT DRAWINGS FOR ALL REQUIRED ACCESS PANELS TO ARCHITECT FOR REVIEW PRIOR TO FRAMING. GC TO NOTIFY ARCHITECT IMMEDIATELY UPON DISCOVERY OF ACCESS PANEL REQUIREMENTS NOT SHOWN ON CONSTRUCTION DOCUMENTS. ALL ACCESS PANELS IN GWB CEILINGS TO BE ISC STYLEMARK DRYWALL ACCESS CEILING DOOR OR EQUAL. SIZE TO ACCOMMODATE REQUIRED ACCESS BUT SHALL BE MINIMUM POSSIBLE DIMENSION. FUR PAN FOR FLUSH DRYWALL INSTALLATION. 8'-0" I A 504 A EQ. 501 A OFFICE EQ. COPY A 502 A OFFICE 6'-2" COATS A OFFICE BID SUBMISSION WITH THE ARCHITECT. 1. NEW GWB CEILING @ 8'-2" AFF, UNLESS NOTED OTHERWISE. PAINT P1 SCHEDULE), UNLESS NOTED OTHERWISE. A (SEE FINISH OFFICE A 2 511 A801 TYP. ISSUES LIGHT FIXTURE SCHEDULE DESCRIPTION LAMP MANUFACTURER FIXTURE NAME CATALOG # A 2X2 RECESSED LENSED LED COOPER LIGHTING CORELITE R2X-WO-2L35-1C-UNV-22-T9 B SURFACE MOUNTED DOWNLIGHT LED COOPER LIGHTING PORTFOLIO LSR6A-10-D010TE-P-ERCW6A-1 0-8-35-6LW0-L1 C UNDERCABINET LIGHTING LED BARTCO BSS305 BSS305 35 F SW WH D NOT USED E1 LINEAR PENDANT - 8' LED NEORAY STRAIGHT & NARROW S23-DP-1L35-SCST-8-U-DD-SI-S93 1 E2 LINEAR PENDANT - 12' LED NEORAY STRAIGHT & NARROW S23-DP-1L35-SCST-12-U-DD-SI-S93 1 E3 LINEAR PENDANT - 4' LED NEORAY STRAIGHT & NARROW S23-DP-1L35-SCST-4-U-DD-SI-S93 1 F1 RECESSED LINEAR - GRID LED NEORAY DEFINE 4 S124-DR-1-35-ETG-0119-1U-DD-1W F2 RECESSED LINEAR - GRID LED NEORAY DEFINE 4 S124-DR-1-35-ETG-0095-1U-DD-1W G NOT USED H SURFACE MOUNTED LINEAR LED NEORAY STRAIGHT & NARROW S23-DS-1L35-ETG-8-1DD-S93 I STRIP LIGHT LED METALUX SNLED 4SNLED-LD4-46SL-LN-UNV-L835-CD 1-U J NOT USED K DECORATIVE PENDANT INCAND FEISS BASKIN P1348PAGB/DWZ WITH INCANDESCENT EDISON-STYLE BULB J:\7235.00 2511 jefferson davis hwy\7235.09_5th floor spec suites\Dwgs\Sheet\suite 515\7235.09_515_A400.dwg Xrefs: 7235.09_515_TTBL; 7235.09_515_PC; 7235.09_515_PFURN; 7235.09_AR; 7235.09_BB TYPE SYMBOL NOTES 03.30.16 BID AND PERMIT FILE INFORMATION PROJECT NO: DRAWN BY: CHECKED BY: DATE: 7235.09 SG | KT LJ 02.10.16 SHEET NAME REFLECTED CEILING PLAN 2 SUBSTITUTIONS TO ANY LIGHT FIXTURES ARE SUBJECT TO THE TENANT ARCHITECT'S WRITTEN APPROVAL, AND SHOULD BE EQUAL IN APPEARANCE, FUNCTION, VOLTAGE, DIMMING, QUALITY OF CONSTRUCTION, ETC. TO THOSE LISTED IN THE SCHEDULE ABOVE. SUBSTITUTIONS TO ANY FIXTURES WILL NOT BE CONSIDERED ANY LATER THAN 5 BUSINESS DAYS PRIOR TO THE BID DUE DATE. SEE SPECIFICATIONS FOR SUBSTITUTION PROCEDURE REQUIREMENTS. SUBSTITUTIONS WITHOUT THE TENANT ARCHITECT'S WRITTEN APPROVAL ARE NOT PERMITTED. REMARKS/ NOTES: 1 PLACE ON DIMMER DRAWING SCALE A400 2 COORDINATE MOUNTING HEIGHT WITH ARCHITECT IN FIELD © 2015 OTJ Architects, Inc.
© Copyright 2026 Paperzz