REFLECTED CEILING PLAN

7235.09_515_A400.dwg March 31, 2016, 4:00 pm
REFLECTED CEILING PLAN NOTES, TYPICAL FOR AND APPLICABLE TO ALL LOCATIONS
SEE SPECIFICATIONS BOOK FOR MORE INFORMATION.
2.
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE GENERAL CONTRACTOR SHALL
PROVIDE “CHALK LINE” LAYOUT OF THE FOLLOWING ITEMS FOR THE ARCHITECT'S ON-SITE
APPROVAL: PARTITION LAYOUT, WITH DOOR AND DOOR SWING LOCATIONS; OUTLET AND
TELEDATA LOCATIONS; SWITCH AND SWITCH BANK LOCATIONS; TRANSFORMER, PANEL,
AND SUPPLEMENTAL MECHANICAL EQUIPMENT LOCATIONS; CEILING SOFFIT LOCATIONS;
VAV BOXES AND LIGHTING LAYOUTS FOR RECEPTION AREAS, CONFERENCE ROOMS, AND
MAJOR PUBLIC SPACES.
3.
REFER TO ARCHITECTURAL RCP FOR EXACT QUANTITY AND LOCATION OF LIGHT FIXTURES,
DIMMING REQUIREMENTS, ETC. ARCHITECTURAL DRAWINGS GOVERN.
4.
GENERAL CONTRACTOR & SUBCONTRACTOR TO THOROUGHLY REVIEW ARCHITECTURAL
AND ENGINEERING DOCUMENTS AND TO NOTIFY ARCHITECT AND ENGINEER IN WRITING
IMMEDIATELY OF DISCREPANCIES FOR RESOLUTION PRIOR TO SUBMISSION OF BID AND TO
PROCEEDING WITH WORK.
5.
GENERAL CONTRACTOR TO REVIEW COORDINATION OF MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER IN WRITING IMMEDIATELY
OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING WITH WORK.
6.
GENERAL CONTRACTOR AND SUBCONTRACTORS TO THOROUGHLY VERIFY AND
COORDINATE ALL CONDITIONS IN FIELD INCLUDING ELECTRICAL PANEL CAPACITY,
LOCATION AND CLEARANCES AT MECH DUCTS, ELECTRICAL ITEMS, SPRINKLERS AND
ASSOCIATED PIPING AND SLAB HEIGHTS. NOTIFY ARCHITECT AND ENGINEER IN WRITING
IMMEDIATELY OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING
WITH WORK.
7.
GENERAL CONTRACTOR TO VERIFY EXTENT OF EXISTING CONSTRUCTION IN FIELD. GC
SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY "AS-BUILT" CONDITIONS CONTRARY
TO THOSE SHOWN OR INFERRED FROM THE CONSTRUCTION DOCUMENTS, PRIOR TO
COMMENCEMENT OF WORK.
8.
EXISTING SLAB HEIGHT IS APPROXIMATELY 9'-11" AFF. GENERAL CONTRACTOR TO VERIFY
HEIGHT PRIOR TO CONSTRUCTION TO DETERMINE HEIGHT CLEARANCES FOR FIXTURES,
CEILING GRID AND ACOUSTICAL CEILING TILES.
9.
C
EQ.
8'-0"
8'-0"
OPEN AREA
518
A
A
8'-0"
B
B
8'-0"
B
OPEN AREA
B
519
F2
REFLECTED CEILING PLAN NOTES, PLAN SPECIFIC
H
CL
B
F2
F2
F2
F2
F2
EQ.
4
A801
515
F1
13. ANY DAMAGE TO THE NEW OR EXISTING CONSTRUCTION CAUSED BY THE GENERAL
CONTRACTOR'S NEGLIGENCE, INADEQUATE PROTECTION, OR INADEQUATE SECURITY
MEASURES DURING CONSTRUCTION ARE TO BE CORRECTED AT THE GENERAL
CONTRACTOR'S EXPENSE.
14. FOR ADDITIONAL INFORMATION REGARDING LIGHT FIXTURE SPECIFICATIONS, REFER TO
ENGINEERING DRAWINGS.
15. FOR EMERGENCY LIGHTING LOCATIONS REFER TO ENGINEERING DRAWINGS.
16. FOR EXIT SIGN LOCATIONS & SPECIFICATIONS REFER TO ENGINEERING DRAWINGS. ALL
EXIT SIGNS ARE TO BE LOCATED IN THE CENTER OF A CEILING TILE, UNLESS NOTED
OTHERWISE.
17. REFER TO MEP DRAWINGS FOR LOCATIONS AND TYPES OF EXIT SIGNS, STROBES, AND
PULLS. ALL EXIT SIGNS TO BE CENTERED ON HALLWAYS AND/ OR OPENING, UNLESS
OTHERWISE NOTED.
18. REFER TO MEP ENGINEERING DOCUMENTS FOR LOCATIONS OF SUPPLY AND RETURN AIR
DIFFUSERS, THERMOSTATS, EXIT LIGHTS AND LIFE SAFETY EQUIPMENT.
19. SOUND LINED TRANSFER DUCTS ARE TO BE PROVIDED AT ALL ROOMS WITH SLAB TO SLAB
PARTITIONS FOR RETURN AIR.
20. UNLESS NOTED OTHERWISE, REFER TO THE ENGINEERING DRAWINGS FOR LIGHT
SWITCHING & LIGHT SWITCH LOCATIONS.
21. GANG ALL ADJACENT SWITCHES UNDER ONE (1) COVERPLATE. IF NEW DIMMERS &
SWITCHES ARE ADJACENT THEY ARE TO BE AT EQUAL HEIGHT WITH 1" BETWEEN
COVERPLATES.
22. ALL SPRINKLER HEADS, LIGHT FIXTURES, EXIT SIGNS, SPEAKER GRILLES, SMOKE
DETECTORS, AND SIMILAR DEVICES SHALL BE LOCATED AT THE CENTER OF CEILING TILE
UNLESS NOTED OTHERWISE.
23. ALL NEW DIMENSIONS ARE FROM FINISH SURFACE TO FINISH SURFACE, UNLESS NOTED
OTHERWISE.
24. ALL HOLES IN SLABS ARE TO BE FILLED WITH CODE COMPLIANT FILLER, REFER TO MEP
SPECS FOR SLAB PENETRATION FIRE-STOP REQUIREMENTS. MAINTAIN THE EXISTING
FLOOR AND CEILING SLAB RATINGS AT ALL SLAB PENETRATIONS AS REQUIRED BY UL
DESIGN GUIDELINES.
25. GENERAL CONTRACTOR TO PROVIDE AN ALLOWANCE FOR ALL EQUIPMENT AND LABOR
REQUIRED FOR THE SYNCHRONIZATION OF FLOOR LOBBY/COMMON CORRIDOR STROBES.
26. PAINT EDGES OF CUT CEILING TILES REMAINING EXPOSED AFTER INSTALLATION. MATCH
COLOR OF FACTORY FINISHED PANEL SURFACES USING COATING RECOMMENDED IN
WRITING FOR THIS PURPOSE BY THE ACOUSTICAL PANEL MANUFACTURER.
27. CLEAN EXPOSED SURFACES OF ACOUSTICAL PANEL CEILINGS, INCLUDING TRIM, EDGE
MOLDINGS, AND SUSPENSION SYSTEM MEMBERS. COMPLY WITH MANUFACTURER'S
WRITTEN INSTRUCTION FOR CLEANING AND TOUCH-UP OF MINOR FINISH DAMAGE.
REMOVE AND REPLACE CEILING COMPONENTS THAT CANNOT BE SUCCESSFULLY
CLEANED AND REPAIRED.
CL
E2
B
F2
A
6"
3'-
C
90°
K
EQ.
E1
B
F2
512
A
509
NEW ACT SYSTEM @ 8'-2" AFF, UNLESS NOTED OTHERWISE. SPEC: "ARMSTRONG"
9
ULTIMA (WHITE) 24X24 SQUARE TEGULAR TILE AND ARMSTRONG SUPRAFINE XL 16
"
EXPOSED TEE GRID (WHITE) WITH AXIOM TRIM WHERE NOTED. FOR CEILING
TRANSITIONS, SEE DETAILS.
OFFICE
510
B
A
OFFICE
OFFICE
514
513
A
B
4
A801
A
1
A801
B
TYP.
Spec Suite 540
Presidential Tower
2511 Jefferson Davis Highway
Arlington, VA 22202
CONSULTANTS
MEP Engineer:
DDG Virginia Engineering
3201 Jermantown Rd. #690
Fairfax, VA 22030
Ph: 703.225.0016
Fax: 703.991.3257
SEAL / SIGNATURE
NEW ACT SYSTEM @ 8'-2" AFF, UNLESS NOTED OTHERWISE. SPEC: "ARMSTRONG"
9
ULTIMA (WHITE) 24X48 SQUARE TEGULAR TILE AND ARMSTRONG SUPRAFINE XL 16
"
EXPOSED TEE GRID (WHITE) WITH AXIOM TRIM WHERE NOTED. FOR CEILING
TRANSITIONS, SEE DETAILS.
A
F2
1'-4"
A
OFFICE
A
K
E1
B
A
CLIENT
EXPOSED CEILING TO UNDERSIDE OF UPPER SLAB. REMOVE ALL EXISTING UNUSED
WIRING, DUCTWORK, ETC. DUCTWORK/HARDWIRE TO BE AT A MINIMUM IN THIS
AREA. ALL WIRING TO BE AT A MINIMUM IN THIS AREA, AND BLUNDLED TO THE
MINIMUM POSSIBLE CODE-COMPLIANT DIMENSIONS. PATCH ALL SLAB HOLES WITH
CODE-COMPLIANT FILLER, SKIM COAT ALL ROUGH AREAS. ALL DUCTWORK,
HARDWIRE, ETC. AND SLAB TO BE PAINTED
(SEE FINISH SCHEDULE).
P1
L1 --
EQ.
B
1412 EYE STREET, NW, WASHINGTON, DC
202.621.1000
WWW.OTJ.COM
REFLECTED CEILING PLAN LEGEND
8'-0"
B
B
OPEN AREA
EQ.EQ.
B
3
A801 B
1'-4"
6
A801
EQ. 3'-3" EQ.
CL
BREAK
1
A801
SIM.
8'-0" CL
508
12. ALL DEVICES AND EQUIPMENT SCHEDULED TO REMAIN ARE TO BE CLEANED, TESTED,
SERVICED IF REQUIRED, AND RESTORED TO FULL OPERATING CONDITION.
6'-6"
B
F1
H
A
E1
5
A801
EQ.
B
A
B
E2
516
B
517
F2
E2
EQ.
CONF.
F1
OPEN AREA
B
500
E3
8'-0"
K
8'-0"
E1
RECEPTION
K
8'-0"
6"
3'-
8'-0"
HUDDLE
K
503
11. AT ALL MAIN CONFERENCE ROOMS, RECEPTION AREAS, AND OTHER PRIMARY PUBLIC
SPACES, GENERAL CONTRACTOR SHALL PAINT PLENUM AREA (SLAB, DUCT, ETC. EXPOSED
CEILING ELEMENTS) BLACK A MINIMUM OF 4'-0" IN ALL DIRECTIONS FROM CENTERLINE OF
ALL RETURN GRILLES. CONSULT AND COORDINATE FULL SCOPE OF THIS WORK PRIOR TO
H
507
8'-0"
6"
3'6"
45°
3'6"
LAN/STOR.
8'-0"
B
3'-
CL
CL
CL
506
A
OFFICE
8'-0"
CL
LAN
505
GENERAL CONTRACTOR TO ARRANGE AND MODIFY ALL EXISTING NON-VISIBLE
MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS TO ENSURE ADEQUATE CLEARANCE
FOR CEILING INSTALLATION AS SHOWN. NOTIFY ARCHITECT AND ENGINEER IN WRITING
IMMEDIATELY OF ANY DISCREPANCY, PRIOR TO SUBMISSION OF BID AND TO PROCEEDING
WITH WORK.
10. ALL MECHANICAL AND PLUMBING WORK ABOVE CEILING SHALL BE LOCATED TO MINIMIZE
REQUIRED ACCESS PANELS IN INACCESSIBLE CEILING AREAS. GENERAL CONTRACTOR
SHALL SUBMIT COORDINATED LAYOUT DRAWINGS FOR ALL REQUIRED ACCESS PANELS TO
ARCHITECT FOR REVIEW PRIOR TO FRAMING. GC TO NOTIFY ARCHITECT IMMEDIATELY
UPON DISCOVERY OF ACCESS PANEL REQUIREMENTS NOT SHOWN ON CONSTRUCTION
DOCUMENTS. ALL ACCESS PANELS IN GWB CEILINGS TO BE ISC STYLEMARK DRYWALL
ACCESS CEILING DOOR OR EQUAL. SIZE TO ACCOMMODATE REQUIRED ACCESS BUT
SHALL BE MINIMUM POSSIBLE DIMENSION. FUR PAN FOR FLUSH DRYWALL INSTALLATION.
8'-0"
I
A
504
A
EQ.
501
A
OFFICE
EQ.
COPY
A 502
A
OFFICE
6'-2"
COATS
A
OFFICE
BID SUBMISSION WITH THE ARCHITECT.
1.
NEW GWB CEILING @ 8'-2" AFF, UNLESS NOTED OTHERWISE. PAINT P1
SCHEDULE), UNLESS NOTED OTHERWISE.
A
(SEE FINISH
OFFICE
A
2 511
A801
TYP.
ISSUES
LIGHT FIXTURE SCHEDULE
DESCRIPTION
LAMP
MANUFACTURER
FIXTURE NAME
CATALOG #
A
2X2 RECESSED LENSED
LED
COOPER
LIGHTING
CORELITE
R2X-WO-2L35-1C-UNV-22-T9
B
SURFACE MOUNTED
DOWNLIGHT
LED
COOPER
LIGHTING
PORTFOLIO
LSR6A-10-D010TE-P-ERCW6A-1
0-8-35-6LW0-L1
C
UNDERCABINET LIGHTING
LED
BARTCO
BSS305
BSS305 35 F SW WH
D
NOT USED
E1
LINEAR PENDANT - 8'
LED
NEORAY
STRAIGHT &
NARROW
S23-DP-1L35-SCST-8-U-DD-SI-S93
1
E2
LINEAR PENDANT - 12'
LED
NEORAY
STRAIGHT &
NARROW
S23-DP-1L35-SCST-12-U-DD-SI-S93
1
E3
LINEAR PENDANT - 4'
LED
NEORAY
STRAIGHT &
NARROW
S23-DP-1L35-SCST-4-U-DD-SI-S93
1
F1
RECESSED LINEAR - GRID
LED
NEORAY
DEFINE 4
S124-DR-1-35-ETG-0119-1U-DD-1W
F2
RECESSED LINEAR - GRID
LED
NEORAY
DEFINE 4
S124-DR-1-35-ETG-0095-1U-DD-1W
G
NOT USED
H
SURFACE MOUNTED LINEAR
LED
NEORAY
STRAIGHT &
NARROW
S23-DS-1L35-ETG-8-1DD-S93
I
STRIP LIGHT
LED
METALUX
SNLED
4SNLED-LD4-46SL-LN-UNV-L835-CD
1-U
J
NOT USED
K
DECORATIVE PENDANT
INCAND
FEISS
BASKIN
P1348PAGB/DWZ WITH
INCANDESCENT EDISON-STYLE
BULB
J:\7235.00 2511 jefferson davis hwy\7235.09_5th floor spec suites\Dwgs\Sheet\suite 515\7235.09_515_A400.dwg
Xrefs: 7235.09_515_TTBL; 7235.09_515_PC; 7235.09_515_PFURN; 7235.09_AR; 7235.09_BB
TYPE
SYMBOL
NOTES
03.30.16
BID AND PERMIT
FILE INFORMATION
PROJECT NO:
DRAWN BY:
CHECKED BY:
DATE:
7235.09
SG | KT
LJ
02.10.16
SHEET NAME
REFLECTED CEILING
PLAN
2
SUBSTITUTIONS TO ANY LIGHT FIXTURES ARE SUBJECT TO THE TENANT ARCHITECT'S WRITTEN APPROVAL, AND SHOULD BE EQUAL IN
APPEARANCE, FUNCTION, VOLTAGE, DIMMING, QUALITY OF CONSTRUCTION, ETC. TO THOSE LISTED IN THE SCHEDULE ABOVE.
SUBSTITUTIONS TO ANY FIXTURES WILL NOT BE CONSIDERED ANY LATER THAN 5 BUSINESS DAYS PRIOR TO THE BID DUE DATE. SEE
SPECIFICATIONS FOR SUBSTITUTION PROCEDURE REQUIREMENTS. SUBSTITUTIONS WITHOUT THE TENANT ARCHITECT'S WRITTEN
APPROVAL ARE NOT PERMITTED.
REMARKS/ NOTES:
1 PLACE ON DIMMER
DRAWING SCALE
A400
2 COORDINATE MOUNTING HEIGHT WITH ARCHITECT IN FIELD
© 2015 OTJ Architects, Inc.