Hyperbaric Chambers and Support Equipment Quiz settings Property Setting Passing score 80% Display Point Value Yes Randomize Questions Yes Total Number of Questions 17 Total Number of Questions to Ask All Display User Score Yes Display Passing Score Yes Display Pass/Fail Messages Yes Email recipient Questions True/False, 10 points, 1 attempt(s) permitted. 1. The inside tender is not responsible for providing first aid as required by the patient. Correct Choice True X False Feedback when correct: Correct Feedback when incorrect: Incorrect True/False, 10 points, 1 attempt(s) permitted. 2. Only the supervisor of a dive should have a checklist. Correct Choice True X False Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Choice, 10 points, 1 attempt(s) permitted. 3. Is emergency gas supply a definite need? Correct X Choice Feedback Yes Incorrect; Emergency gas supply is a definite need if feasible No Incorrect; Emergency gas supply is a definite need if feasible Yes, if feasible Correct Multiple Choice, 10 points, 1 attempt(s) permitted. 4. How many scfm are recommended for occupants at rest while breathing by mask? Correct X Choice Feedback 10 Incorrect; 13 scfm are recommended for occupants at rest while breathing by mask. 11 Incorrect; 13 scfm are recommended for occupants at rest while breathing by mask. 12 Incorrect; 13 scfm are recommended for occupants at rest while breathing by mask. 13 Correct True/False, 10 points, 1 attempt(s) permitted. 5. There is danger of having too little oxygen in the chamber when using air for pressurization. Correct Choice True X False Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Choice, 10 points, 1 attempt(s) permitted. 6. What does BIBS stand for? Correct X Choice Feedback Big Interior Breathing System Incorrect; BIBS stands for Built-In-Breathing System Built-Interior-Breathing System Incorrect; BIBS stands for Built-In-Breathing System Built-In-Breathing System Correct Big-In-Breathing System Incorrect; BIBS stands for Built-In-Breathing System Multiple Choice, 10 points, 1 attempt(s) permitted. 7. The trio of conditions necessary for a fire does NOT include what? Correct Choice Feedback Oxygen Incorrect; The trio of conditions necessary for a fire does NOT include a lit match Source of ignition Incorrect; The trio of conditions necessary for a fire does NOT include a lit match X Combustible materials Incorrect; The trio of conditions necessary for a fire does NOT include a lit match A lit match Correct Multiple Choice, 10 points, 1 attempt(s) permitted. 8. Which of these should a chamber be equipped with? Correct X Choice Feedback Viewports Incorrect; a chamber should be equipped with all items listed Stopwatches Incorrect; a chamber should be equipped with all items listed Gas monitoring systems Incorrect; a chamber should be equipped with all items listed BIBS Incorrect; a chamber should be equipped with all items listed All of the above Correct True/False, 10 points, 1 attempt(s) permitted. 9. Primary air supply pressurizes the chamber to thrice the treatment depth. Correct Choice True X False Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Choice, 10 points, 1 attempt(s) permitted. 10. What is the recommended amount of scfm for active occupants using breathing masks? Correct X Choice Feedback 20 scfm Incorrect; 25 scfm is recommended for active occupants using breathing masks 22 scfm Incorrect; 25 scfm is recommended for active occupants using breathing masks 25 scfm Correct 27 scfm Incorrect; 25 scfm is recommended for active occupants using breathing masks True/False, 10 points, 1 attempt(s) permitted. 11. Basic ventilation rules are not intended to limit ventilation. Correct X Choice True False Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Choice, 10 points, 1 attempt(s) permitted. 12. The oxygen level in a hyperbaric chamber should be maintained between what? Correct X Choice Feedback 20-22 percent Incorrect; the oxygen level in a hyperbaric chamber should be maintained between 21-23 percent 21-23 percent Correct 22-24 percent Incorrect; the oxygen level in a hyperbaric chamber should be maintained between 21-23 percent 23-25 percent Incorrect; the oxygen level in a hyperbaric chamber should be maintained between 21-23 percent Multiple Choice, 10 points, 1 attempt(s) permitted. 13. How often should the chamber be inspected inside and out? Correct X Choice Feedback Once a year Incorrect; a chamber should be inspected inside and out twice a year Once a month Incorrect; a chamber should be inspected inside and out twice a year Twice a year Correct Twice a month Incorrect; a chamber should be inspected inside and out twice a year Multiple Response, 10 points, 2 attempt(s) permitted. 14. Hyperbaric chambers are also referred to, interchangeably, as decompression chambers, recompression chambers, or hyperbaric chambers; in diving they are used for: (select all that apply) Correct Choice X Surface decompression X Omitted decompression X Recompression of injured divers X Training X Research X Pressure testing of equipment Wound care Treatment of burns Feedback when correct: Correct Feedback when incorrect: Incorrect Matching Drag and Drop, 10 points, 1 attempt(s) permitted. 15. Match the Class of hyperbaric chamber with its description: Choice Match Class A A multi-place chamber, built for occupancy by more than one person Class B A monoplace chamber, built for occupancy by only one person. These are more typically used in hospital settings. An animal chamber, built for conducting research or treating animals Class C Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Response, 10 points, 2 attempt(s) permitted. 16. Select all that apply to the "hyperbaric stretcher" pictured here: Correct Choice X It is low cost when compared to other types of hyperbaric chambers X It is a monoplace chamber X It has minimal gas requirements compared to other types of hyperbaric chambers It has greater gas requirements compared to other types of hyperbaric chambers It is a multi-place chamber X It can be stored in two footlocker size boxes Feedback when correct: Correct Feedback when incorrect: Incorrect Multiple Choice, 10 points, 1 attempt(s) permitted. 17. Oxygen analyzers are useful for monitoring oxygen concentrations in chambers. In recent years _____ have been mounted on air supply systems to ensure the quality of the air supply. Correct Choice redundent oxygen analyzers X carbon monoxide analyzers carbon dioxide analyzers helium analyzers Feedback when correct: Correct Feedback when incorrect: Incorrect
© Copyright 2026 Paperzz