Smart Gas Meter Series

FLONIDAN
Smart Gas Meter Series
UNIFLO G1.6S - G25S
• M-bus, wired or wireless, or Zigbee RF serial data output
• Secure AMR, using AES encryption
• Reliable, tamper safe optical detection of measuring unit with “Gray-Code”
• Excellent accuracy, using error curve correction
• Built-in, temperature conversion
Innovative Leadership
• Data logger for readings, alarms and events
www.flonidan.com
• Calculated battery lifetime min. 20 years
• Built-in valve for remote closing and safe opening of gas flow
Communication
• Wired and Wireless M-Bus, following
EN 13757, has been implemented in
2 versions:
1. DSMR (Dutch Smart Meter
Requirement).
2. OMS (Open Metering System).
• Zigbee-RF in development.
• Modular communication module can
be exchanged
• In standard configuration, calculated
lifetime of battery is min. 20 years.
(Wired 1 x AA and Wireless 2 X AA).
See separate Communication Datasheet for
more details.
The information contained in this document is subject to change without notice.
Radio DSMR Radio OMS
Wired M-Bus
Flonidan
DCisA/S
ISO 9001:2000
Flonidan A/S
ISO is
9001:2008
certified. certified.
1
Integrated valve
Electronic index
Push button
for valve
Measuring unit
Gray-Code
detection
Gray-Code detection system
Micro processor
The movement of the gas measuring unit is detected by a unique, High Frequent optical detection system, based on Gray-Code and 3 optical sensors on
the PCB. This system offers high resolution and a
tamperproof and failsafe detection, fit for instant flow
calculation and error curve correction.
Excellent accuracy
2%
Final error code
The initial error curve of the diaphragm gas-meter is
introduced into the micro-processor in the index at 3
flows, Qmin, 0,2Qmax and Qmax.
after correction
Original meter
0%
With the High Frequency “Gray-Code” detection,
flow is calculated and by linear interpolation and
the error curve of the measuring unit corrected to
approx. 0.1%.
error curve
Correction by
linear interpola-
-2%
Qmin.
0.2Qmax.
Qmax.
tion
Temperature conversion (option)
Temperature conversion may be performed, for read out of base volume or energy.
A unique temperature measurement system ensures a precise measurement of temperature inside the
measuring unit, independent of the inlet gas temperature and the ambient temperature.
Correct measurement of gas temperature improves the accuracy with up to 3%.
Alarm log
Uniflo G4S electronic index has an auto diagnostic system, monitoring the conditions of the meter:
• Remaining life of battery (live calculation)
• Gas temperature, low and high limit*
• Temperature sensor error*
• High and high-high flow limit
• Gray-Code detection error
• Daily max. consumption error
• Self check error (hardware and software)
• Tamper detection (mechanical, magnetic)
30 latest errors will be recorded, along with time stamp.
*) Only for meter with temperature conversion
2
Tamper proof
Mechanical tampering of the index is not possible, as moving parts in the index are reduced to a minimum.
Removal of front cover will activate tamper alarm. The detection system is not sensitive for normal magnetic
fields. In case of extremely powerful magnets, a magnetic tamper alarm will be activated.
Communication is secured by encryption (AES compatible), with individual encryption keys, and by detection of invalid communication format, activating alarm.
Reverse gas flow will be stopped by mechanical lock in measuring unit, and reverse rotation will be detected by the “Gray-Code” and immediately activate an alarm. Also exceeding max. flow limit, or max. daily consumption limit will activate alarm. Alarms will be stored in the memory, with time stamp, to be transferred at
the next meter reading, or immediately, when radio is used. Alarms can be reset remotely.
Integrated valve (option)
The meter may be supplied with built-in valve, offering remotely closing of the gas-flow, after receiving
the signal at the meter reading.
Because opening of gas-valve might have important
safety impact (e.g. an opened unsecured gas-cooker), Flonidan has developed, both in hardware and
software, a dedicated procedure.
After the communication unit has given the signal
“open valve”, customer has to push a button on the
index to open the valve again. If the meter after
opening detects, within a given time frame, a too
high gas consumption, the valve will automatically
close again. Customer should first shut off gas consuming devices, before pushing the button again.
The time frame and max. gas consumption can be
configured on customer specifications (See diagram).
Command for safe opening without customer intervention is also available (See diagram).
CLOSE
OPEN DIRECT
OPEN INDIRECT
Communication Unit
gives command to close
gas valve
Communication Unit gives
command for direct opening
of gas valve
Communication Unit gives
command for indirect opening
of gas valve
LCD changes between:
“NO GAS” and counter
value
Gas valve is closed
LCD changes between:
“PRESS” and counter value
Customer checks on open
gas cooker e.a.
Customer pushes button on
index
LCD indicates “ERROR” for
10 seconds
LCD indicates: ”OPENS” and
gas valve opens halfway
Wait for pipe filling
Wait for flow control
Valve opens fully,
LCD indicates counter value
and the customer has gas
again
NO
YES
Flow too high ?
Gas valve closes
3
TECHNICAL SPECIFICATIONS
ΔP1)
dm3
m3/h
m3/h
bar
mbar
1.2
2.5
0.016
0.5
0.8
X
G2.5
4
0.025
0.5
1.1
X
G4
6
0.04
0.5
1.4
X
6
0.04
0.5
1.4
X
10
0.06
0.5
2
X
16
0.1
1
1.7
X
25
0.16
1
3
X
20
40
0.25
1
2.8
X
Vc
H
W
D
d
C
T
M
mm
mm
mm
mm
mm
mm
kg
1.2
206
214
157
66
110
130
3/4”GM 2
G5/4”
G7/8”
G4
1.2
267
235
169
72
152.4
BS1”
G2.5
2.2
281
326
182
79
220
3/4”GM 3.4
276
326
182
79
250
G5/4”
3.4
G 1.6
G4
2.2
G6
G10
5
G16
G25
dm3
G1.6
G2.5
G4
G4
3.1
G6
G4
2.2
289
231
179
78
mono
G2”
3.6
G10
5
345
396
214
93
280
G2”
6.8
300
G2”
G16
G25
20
443
457
289
138
335
G2½”
13.3
481
547
330
158
400
G2½”
13.6
469
457
289
138
mono
DN50
fl.
14.2
1) Air at Qmax without valve, 2) Can be disabled
Temperature range:
Approvals:
MID:2004, DVGW1), ATEX
1) Various types
Conformity with:
Type definition
Uniflo
G4SRTV
EN1359:1998, incl. annex B (entire meter)
EN1359-A1:2006
V: Integrated valve
NTA 8130:2007 , DSMR 2.2 (Netherland)
OIML D11(EMC) (electronic index)
T: Temperature conversion
R: Radio (wireless M-bus) - M:Wired
M-bus - O:Ready for option board
Battery lifetime:
S: Flonidan Smart Meter
15 years, calculated 20 years
G4: Meter G-size (G1.6-G25)
EN12405 (electronic index)
Display:
Flonidan A/S 2014-02-14. Copyright©Flonidan A/S 2014
Rev. 14.02.2014
Tamb.: -25...+55°C, Tgas.: -25...+55°C
9 digits, 0, 3 or 4 decimals (configurable)
4
FLONIDAN A/S
Islandsvej 29 · DK-8700 Horsens · Tel: +45 75 61 88 88 · Fax +45 75 62 60 88 · www.flonidan.com
FLONIDAN