Non-Contact Temperature Measurements: Fast, precise and

High measuring accuracy
long-term stability
Fast response for
real time process controls
Precise focusing
onto small targets
Proprietary chopped
radiation method
We keep your temperature under control
Infrared
Radiation Pyrometer
Exhaust gas temperature
measurements in waste
incinerator plants
Temperature measurements
of glass
Airborne radiometric and
thermal surveys
KT19 II
Non-Contact Temperature
Measurements:
Fast, precise and
application oriented
THE ULTIMATE RADIATION PYROMETER FOR UNLIMITED
APPLICATIONS IN INDUSTRY, LABORATORY & RESEARCH
The KT19 II implements the most advanced infrared technology
of the forthcoming generation. New performance features bring
added functionality beneficial to difficult and complex applications. The KT19 II sets unsurpassed standards in
radiation pyrometry. It is the ultimate high performer for non-contact temperature
measurements to cope with extremely
unfavorable boundary conditions.
The magnitude of available
options and freely
selectable operating
parameters allows
ideal adaptation for
the specific requirements of all feasible
applications.
The Optimum Instrument
for Each Application
More than 20 different models
with different spectral bands in
the range from 2 µm to 20 µm
and temperature ranges from
-100 °C to 3,000 °C are available.
A variety of interchangeable lenses and optical spacers, in conjunction with optional detector
sizes, allow focusing to more
than 530 variations of field-ofview configurations and minimum
target sizes of 0.7mm in diameter.
The World's First
Multifunctional Display
The integrated multifunctional
display, a unique implementation
in pyrometric instrumentation,
makes menu selections as easy
as a call from a cellular phone,
and allows the complete
configuration of all functions and
specific operating parameters.
High Performance in a Nut-Shell
The new KT19 II excels by a number of unequaled performance data.
The response time is adjustable from 5 msec, to monitor and control extremely short production cycles,
up to 10 minutes, to integrate measurements in long-term thermal processes with an extremely high
resolution.
The linearity error of less than 0.02 K over the entire temperature range allow calibration of the KT19 II on a
suitable blackbody calibration source with a minimum of fixed points and with high accuracy.
The complete elimination of thermal drift at low measuring temperatures by the unique chopped radiation
method and the high resolution of 10 mK are necessary prerequisites to deploy the KT19II as transfer
standard in infrared equipment calibrations.
Easy setup: Via the digital interface the KT19 II can be
configured from a PC. Transfer rate up to 115.200 bps.
Data evaluation on the PC: Measured temperature
profiles are directly displayed in Windows-graphics,
as shown below. A Multitude of Potential Applications
Interchangeable infrared lenses, optical spacers, and the option
of different detector sizes allow the choice of more than 530
optical configurations for an optimum focus on small or
extended targets.
Target size dimensions for 26 mm lenses and detector type C
Target size in mm
Working distance
in mm
0,7 (M6)
21
1,5 (L6)
1,9 (N6)
95
150
Other options include optical view finder or laser pointer for
accurate aiming the KT19II onto the target. The laser beam
flashes periodically for better identification on dark colored
target surfaces.
Target size dimensions for 39 mm lenses and detector type C
10,5 (K6)
950
Target size in mm 2,1 (S921+Z1+Z2) 3,2 (S921+Z1)
Working distance
in mm
310
400
4,2 (S921+Z2)
10,5 (S921)
530
1100
Typical target size configurations: Only for lenses and detector combinations indicated above.
Accessories
The integrated laser pointer
marks the target size of the
field of view. Extensive accessories support
the KT19 Series II.
Optical attachments for 90°
deflection, various mechanical
attachments and adapters for
mounting blackbody calibration
sources, intelligent temperature
meters, software for data
processing and data logger,
etc. are available.
Portable Blackbody
calibration source SW15
Air purge attachment
A specially designed
protective and coolable
housing extends the
permissible ambient
temperature to 300°C.
Protective coolable housing
with mounting attachment
Applications
The new instruments of the KT19 Series II incorporate
advanced signal processing based on of the latest digital
technology. The improved performance of the newly
integrated features and the open architecture of the digital
software guarantee the possibility of later upgrades for future
applications.
A special feature of the
KT19 Series II:
Emissivity, transmissivity,
and reflectivity of the
target can be separately
programmed with their
corresponding ambient
temperatures for
optimum control of
target temperatures.
As a result of the application oriented development, the
KT19 Series II covers a broad range of potential applications,
in research, in laboratory
Temperature
Temperature
explorations, or as an
monitoring
measurements
integral part in industrial
in steel milling
in varnishing plants
manufacturing processes.
Deployment of non-contact
temperature measurements
cover widely spread
applications on glass
and metal surfaces, plastic
foils, ceramics, gases
and flames.
… and in plastic foil production
Selection Guide: Infrared Radiation Pyrometer KT19-Series II
Model
KT19.01
KT19.02
KT19.21
KT19.23
KT19.24
KT19.25
KT19.41
KT19.42
KT19.43
KT19.61
KT19.62
KT19.63
KT19.69
KT19.81
KT19.82
KT19.83
KT19.85
KT19.xx
Spectral
Response/µm
2.00 ... 2.70
2.00 ... 4.50
3.43 ± 0.15
6.80 ± 0.15
7.93 ± 0.15
8.05 ± 0.15
3.90 ± 0.10
4.90 ... 5.50
7.50 ... 8.20
4.26 ± 0.13
4.50 ± 0.10
4.66 ± 0.10
Tmin …Tmax °C
Application
250 ... 2,500
metals, metal oxides, ceramics, glass volume
100 ... 1,200
metals, metal oxides, ceramics, glass volume (lower temperatures)
80 ... 350
plastic films with CH-band, org. coating materials (oil, paints)
40 ... 400
thin film plastics, e.g. PE, PP, PVC
0 ... 400
thin film plastics, e.g. PET, PA, fluorcarbon
0 ... 400
thin film plastics, e.g. PETE, PET, PVC
200 ... 2,500
glass volume, measurements through hot gases and flames
100 ... 2,500
glass (processing), quartz
0 ... 2,500
glass, quartz, ceramics, glass (thin plates)
300 ... 2,500
hot gases and flames (CO2-band)
300 ... 2,500
hot gases and flames (CO2- and CO-band)
300 ... 2,500
hot gases and flames (CO-band)
400 ... 2,500
hot gases in incinerators, rotary kilns
8 ... 10
0 ... 1,000
paper, textiles, rubber, wood, ceramics, thicker plastics (>1mm),
8 ... 14
-50 ... 1,000
painted or coated surfaces, asphalt, building materials,
8 ... 20
-50 ... 1,000
electronic components, food, liquids
9.6 ... 11.5
-50 ... 200
meteorological, biological, agricultural studies, large measuring distances
several spectral ranges available, temperature range depending on application
General Specifications
Temperature ranges
Temperature resolution (NETD)*
Accuracy
Long-term stability
Lenses*
Depends on model, minimum and maximum measuring temperature, see table above
Depends on model, detector size, measuring temperature and response time; typical value ±0.1°C
±0.5°C plus 0.7% of the difference between target temperature and housing temperature
Better than 0.01% of the absolute measured temperature in Kelvin/month
Several far-focus and close-focus lenses with different optical characteristics,
vacuum tight types available
Field of view*
Depends on model, detector and lens type. For close-focus lenses: from 0.7 mm diameter
at <20 mm distance; for far-focus lenses: typically 10 to 20 mm diameter at distances >1,000 mm.
Aiming options
Built-in viewfinder with display, integrated laser aiming sight,
more optical and mechanical options are available
LCD-graphic-display at rear
for measured value display, programmed parameter, alarm display and programming
Keyboard at rear for programming of Emissivity, reflectivity, ambient temperature, alarm relay, analog output, response time, temperature
unit, serial interface, read-out of MIN/MAX value, calibration procedure and laser ON/OFF-switch
Emissivity / reflectivity
Adjustable from 0.100 to 1.000 in 0.001 increments
Response time
Programmable: 5 msec to 10 min
Analog output
4 scalable output signals: linear voltage or current,
0..1 V, 0...10 V, 0...20 mA or 4...20 mA (programmable)
Serial interface
RS-232 interface, bi-directional, baud rate 9,600 to 115,200 bps,
for programming and data transfer
Alarm relays
Two set-points indicated on LCD display
Thermal switch
Monitoring the housing temperature
Power requirements
22...30 VDC or 24 VAC ±10%, 48...400 Hz; ≤150 mA with 24 VDC
Permissible ambient temperature -20°C...60°C, with protective and cooling housing 300°C
Storage temperature
-20°C ... 70°C
Housing protection/Weight
IP 65 (DIN 4005) NEMA 4 equivalent, approx. 2.5 kg
*Please ask for our additional literature (temperature ranges, temperature resolution, field of view) ”Technical Data”,
”Field of View Diagrams”, ”Options and Accessories”.
03.2002/030/e/D&F/ Wiehr- Design
Housing dimensions in mm (inches)
HEITRONICS Infrarot Messtechnik GmbH • Kreuzberger Ring 40 • D-65205 Wiesbaden • Tel. ++49 (0)611 973 930