High measuring accuracy long-term stability Fast response for real time process controls Precise focusing onto small targets Proprietary chopped radiation method We keep your temperature under control Infrared Radiation Pyrometer Exhaust gas temperature measurements in waste incinerator plants Temperature measurements of glass Airborne radiometric and thermal surveys KT19 II Non-Contact Temperature Measurements: Fast, precise and application oriented THE ULTIMATE RADIATION PYROMETER FOR UNLIMITED APPLICATIONS IN INDUSTRY, LABORATORY & RESEARCH The KT19 II implements the most advanced infrared technology of the forthcoming generation. New performance features bring added functionality beneficial to difficult and complex applications. The KT19 II sets unsurpassed standards in radiation pyrometry. It is the ultimate high performer for non-contact temperature measurements to cope with extremely unfavorable boundary conditions. The magnitude of available options and freely selectable operating parameters allows ideal adaptation for the specific requirements of all feasible applications. The Optimum Instrument for Each Application More than 20 different models with different spectral bands in the range from 2 µm to 20 µm and temperature ranges from -100 °C to 3,000 °C are available. A variety of interchangeable lenses and optical spacers, in conjunction with optional detector sizes, allow focusing to more than 530 variations of field-ofview configurations and minimum target sizes of 0.7mm in diameter. The World's First Multifunctional Display The integrated multifunctional display, a unique implementation in pyrometric instrumentation, makes menu selections as easy as a call from a cellular phone, and allows the complete configuration of all functions and specific operating parameters. High Performance in a Nut-Shell The new KT19 II excels by a number of unequaled performance data. The response time is adjustable from 5 msec, to monitor and control extremely short production cycles, up to 10 minutes, to integrate measurements in long-term thermal processes with an extremely high resolution. The linearity error of less than 0.02 K over the entire temperature range allow calibration of the KT19 II on a suitable blackbody calibration source with a minimum of fixed points and with high accuracy. The complete elimination of thermal drift at low measuring temperatures by the unique chopped radiation method and the high resolution of 10 mK are necessary prerequisites to deploy the KT19II as transfer standard in infrared equipment calibrations. Easy setup: Via the digital interface the KT19 II can be configured from a PC. Transfer rate up to 115.200 bps. Data evaluation on the PC: Measured temperature profiles are directly displayed in Windows-graphics, as shown below. A Multitude of Potential Applications Interchangeable infrared lenses, optical spacers, and the option of different detector sizes allow the choice of more than 530 optical configurations for an optimum focus on small or extended targets. Target size dimensions for 26 mm lenses and detector type C Target size in mm Working distance in mm 0,7 (M6) 21 1,5 (L6) 1,9 (N6) 95 150 Other options include optical view finder or laser pointer for accurate aiming the KT19II onto the target. The laser beam flashes periodically for better identification on dark colored target surfaces. Target size dimensions for 39 mm lenses and detector type C 10,5 (K6) 950 Target size in mm 2,1 (S921+Z1+Z2) 3,2 (S921+Z1) Working distance in mm 310 400 4,2 (S921+Z2) 10,5 (S921) 530 1100 Typical target size configurations: Only for lenses and detector combinations indicated above. Accessories The integrated laser pointer marks the target size of the field of view. Extensive accessories support the KT19 Series II. Optical attachments for 90° deflection, various mechanical attachments and adapters for mounting blackbody calibration sources, intelligent temperature meters, software for data processing and data logger, etc. are available. Portable Blackbody calibration source SW15 Air purge attachment A specially designed protective and coolable housing extends the permissible ambient temperature to 300°C. Protective coolable housing with mounting attachment Applications The new instruments of the KT19 Series II incorporate advanced signal processing based on of the latest digital technology. The improved performance of the newly integrated features and the open architecture of the digital software guarantee the possibility of later upgrades for future applications. A special feature of the KT19 Series II: Emissivity, transmissivity, and reflectivity of the target can be separately programmed with their corresponding ambient temperatures for optimum control of target temperatures. As a result of the application oriented development, the KT19 Series II covers a broad range of potential applications, in research, in laboratory Temperature Temperature explorations, or as an monitoring measurements integral part in industrial in steel milling in varnishing plants manufacturing processes. Deployment of non-contact temperature measurements cover widely spread applications on glass and metal surfaces, plastic foils, ceramics, gases and flames. … and in plastic foil production Selection Guide: Infrared Radiation Pyrometer KT19-Series II Model KT19.01 KT19.02 KT19.21 KT19.23 KT19.24 KT19.25 KT19.41 KT19.42 KT19.43 KT19.61 KT19.62 KT19.63 KT19.69 KT19.81 KT19.82 KT19.83 KT19.85 KT19.xx Spectral Response/µm 2.00 ... 2.70 2.00 ... 4.50 3.43 ± 0.15 6.80 ± 0.15 7.93 ± 0.15 8.05 ± 0.15 3.90 ± 0.10 4.90 ... 5.50 7.50 ... 8.20 4.26 ± 0.13 4.50 ± 0.10 4.66 ± 0.10 Tmin …Tmax °C Application 250 ... 2,500 metals, metal oxides, ceramics, glass volume 100 ... 1,200 metals, metal oxides, ceramics, glass volume (lower temperatures) 80 ... 350 plastic films with CH-band, org. coating materials (oil, paints) 40 ... 400 thin film plastics, e.g. PE, PP, PVC 0 ... 400 thin film plastics, e.g. PET, PA, fluorcarbon 0 ... 400 thin film plastics, e.g. PETE, PET, PVC 200 ... 2,500 glass volume, measurements through hot gases and flames 100 ... 2,500 glass (processing), quartz 0 ... 2,500 glass, quartz, ceramics, glass (thin plates) 300 ... 2,500 hot gases and flames (CO2-band) 300 ... 2,500 hot gases and flames (CO2- and CO-band) 300 ... 2,500 hot gases and flames (CO-band) 400 ... 2,500 hot gases in incinerators, rotary kilns 8 ... 10 0 ... 1,000 paper, textiles, rubber, wood, ceramics, thicker plastics (>1mm), 8 ... 14 -50 ... 1,000 painted or coated surfaces, asphalt, building materials, 8 ... 20 -50 ... 1,000 electronic components, food, liquids 9.6 ... 11.5 -50 ... 200 meteorological, biological, agricultural studies, large measuring distances several spectral ranges available, temperature range depending on application General Specifications Temperature ranges Temperature resolution (NETD)* Accuracy Long-term stability Lenses* Depends on model, minimum and maximum measuring temperature, see table above Depends on model, detector size, measuring temperature and response time; typical value ±0.1°C ±0.5°C plus 0.7% of the difference between target temperature and housing temperature Better than 0.01% of the absolute measured temperature in Kelvin/month Several far-focus and close-focus lenses with different optical characteristics, vacuum tight types available Field of view* Depends on model, detector and lens type. For close-focus lenses: from 0.7 mm diameter at <20 mm distance; for far-focus lenses: typically 10 to 20 mm diameter at distances >1,000 mm. Aiming options Built-in viewfinder with display, integrated laser aiming sight, more optical and mechanical options are available LCD-graphic-display at rear for measured value display, programmed parameter, alarm display and programming Keyboard at rear for programming of Emissivity, reflectivity, ambient temperature, alarm relay, analog output, response time, temperature unit, serial interface, read-out of MIN/MAX value, calibration procedure and laser ON/OFF-switch Emissivity / reflectivity Adjustable from 0.100 to 1.000 in 0.001 increments Response time Programmable: 5 msec to 10 min Analog output 4 scalable output signals: linear voltage or current, 0..1 V, 0...10 V, 0...20 mA or 4...20 mA (programmable) Serial interface RS-232 interface, bi-directional, baud rate 9,600 to 115,200 bps, for programming and data transfer Alarm relays Two set-points indicated on LCD display Thermal switch Monitoring the housing temperature Power requirements 22...30 VDC or 24 VAC ±10%, 48...400 Hz; ≤150 mA with 24 VDC Permissible ambient temperature -20°C...60°C, with protective and cooling housing 300°C Storage temperature -20°C ... 70°C Housing protection/Weight IP 65 (DIN 4005) NEMA 4 equivalent, approx. 2.5 kg *Please ask for our additional literature (temperature ranges, temperature resolution, field of view) ”Technical Data”, ”Field of View Diagrams”, ”Options and Accessories”. 03.2002/030/e/D&F/ Wiehr- Design Housing dimensions in mm (inches) HEITRONICS Infrarot Messtechnik GmbH • Kreuzberger Ring 40 • D-65205 Wiesbaden • Tel. ++49 (0)611 973 930 Fax ++49 (0)611 973 93 26 • e-Mail [email protected] • http://www.heitronics.com
© Copyright 2025 Paperzz