Rinnai INFINITY VT specification summary

Specification guide
Rinnai INFINITY®
gas continuous flow water heating
Important
Rinnai is constantly improving its products, and as such,
information and specifications are subject to change without
notice. For the most up-to-date information go to
www.rinnai.co.nz.
This information is not intended as an installation guide.
We’d love to hear from you
If you have any feedback about this guide
we’d love to hear from you. Either email us at
[email protected] (place ‘Rinnai specification
guide feedback’ in the subject heading), or call
Customer Services.
Help is here
For more information about buying, using, and
servicing of Rinnai appliances call: 0800 RINNAI
(0800 746 624).
Rinnai New Zealand Limited
105 Pavilion Drive, Mangere, Auckland
PO Box 53177, Auckland Airport, Auckland 2150
Phone:
(09) 257 3800
Email: [email protected]
Web:
www.rinnai.co.nz
www.youtube.com/rinnainz
www.facebook.com/rinnainz
:
s
t
n
e
t
n
co
Leaders in continuous flow.....................................4
What is continuous flow?.........................................5
Continuous flow summary table.............................6
Model selection for residential applications...........7
Model selector........................................................8
Location of Rinnai INFINITY units............................9
General clearances..................................................10
Product specification pages
Rinnai INFINITY VT..................................................12
Rinnai INFINITY HD.................................................14
Rinnai INFINITY EF...................................................16
Rinnai INFINITY accessories summary table...........18
Rinnai INFINITY internal flueing options.................20
Rinnai INFINITY flueing guidelines..........................21
Direct flueing using the FFSSKIT..............................22
Horizontal extension flueing...................................22
Vertical straight flueing...........................................23
Combination flueing...............................................23
Rinnai INFINITY flue components...........................24
Rinnai INFINITY accessories
Rinnai INFINITY digital controllers..........................28
Rinnai INFINITY composite recess box....................30
Rinnai INFINITY metal recess box............................31
Rinnai INFINITY pipe covers....................................32
Rinnai INFINITY security bracket.............................33
Rinnai INFINITY sideways flue diverter....................34
Rinnai INFINITY upwards flue diverter.....................35
Rinnai INFINITY HD error switch.............................36
Rinnai INFINITY EZ connect cable...........................37
Rinnai INFINITY manifolding...................................38
Appendices
Appendix 1
Water flow and gas usage........................................40
Appendix 2
Rinnai INFINITY inbuilt frost protection..................46
Appendix 3
Manifolding components what to use where..........47
Appendix 4
HD connection positions underneath unit.............48
Appendix 5
EF connection positions underneath unit...............49
Appendix 6
LPG gas bottle consumption and cylinder clearances... 50
Appendix 7
Gas boosted solar....................................................51
Leaders in continuous flow
When you turn on a tap you want water at the right temperature fast, which is
why over the years we’ve devoted considerable time and resource to leading
edge research and development.
We were the first to introduce continuous flow technology and have been tirelessly working on
improving this ever since. Our commitment to bring you the latest technology has resulted in
the next generation of water heaters.
1991 Rinnai INFINITY original microprocessor
1995 Rinnai INFINITY Q-function
2002 Rinnai INFINITY dynamic flow control
2004 Rinnai INFINITY V-Series rapid start
2006 Rinnai INFINITY XR
2008 Rinnai INFINITY EF
2011 Rinnai INFINITY VT
2013 Rinnai INFINITY VT series 2*
The Rinnai INFINITY range is made up of the following three categories:
Rinnai INFINITY VT (residential applications only)
Valve technology that delivers performance and efficiency for daily living.
Rinnai INFINITY EF (residential and commercial applications)
High efficiency condensing technology to deliver further savings.
Rinnai INFINITY HD (residential and commercial applications)
Heavy duty on demand for demanding jobs.
* Rinnai INFINITY Series 2: Improved software, which allow the units to run more efficiently—this has resulted
in increased energy star ratings.
4 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
What is continuous flow?
A continuous flow gas hot water system only heats water when it passes through the
unit. It will deliver a continuous flow of heated water at a predetermined flow rate,
depending on the model, as long as the unit is connected to the power supply.
General principle of operation
Each Rinnai INFINITY has a number of components that control the accuracy of water
temperature and water flow. These components are:
•
•
•
•
•
PCB (the onboard computer)
water control valve
water flow sensor
modulating gas valve
outlet water temperature sensor
The unit senses the need to start when water begins to flow through the appliance (when a tap is
turned on). The combustion fan starts, ignition begins (electronic requiring electricity), and the
gas valve opens. Once the flame is established the appliance will heat the water as required until
the tap is turned off.
How gas continuous flow works
Standard VT/HD continuous flow unit
Condensing EF continuous flow unit
5% Loss
95%
Efficiency
CH
HC
Condensing technology utilises a secondary latent heat exchanger to increase the thermal
efficiency of the unit (95% vs. 80%). Incoming cold water passes through the latent heat
exchanger first where heat is extracted from the exhaust gas (which would otherwise be
wasted), which preheats the water by approximately 5 °C before going to the primary heat
exchanger.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 5
Continuous flow summary table
Rinnai
INFINITY
model
Mounting Application suitability
position
Energy
star
rating
Input
Output
Thermal
efficiency
on high
Status
monitor
VT16
External
Residential only
6.2
125 MJ/h or 35 kW
29.6 kW
81%
No
VT20
External
Residential only
6.1
160 MJ/h or 44 kW
34.9 kW
80%
No
VT24
External
Residential only
6.0
188 MJ/h or 52 kW
42.1 kW
80%
No
VT26
External
Residential only
6.1
199 MJ/h or 55 kW
44.2 kW
80%
No
HD200
External
Residential and commercial 5.9
199 MJ/h or 55 kW
47.0 kW
82%
Yes
HDi200
Internal
Residential and commercial 6.1
195 MJ/h or 54 kW
45.1 kW
83%
No
HD250
External
Residential and commercial 5.9
250 MJ/h or 69 kW
59.9 kW
81%
No
EF24
External
Residential and commercial 6.8
162 MJ/h or 45 kW
43.0 kW
95%
No
EF250
External
Residential and commercial 7.0
211 MJ/h or 58.6 kW
55.6 kW
95%
Yes
EFi250
Internal
Residential and commercial 7.0
211 MJ/h or 58.6 kW
55.6 kW
95%
Yes
In tern al m o de ls
Ex te rn a l m o d e l s
Water delivery
at a 25 °C rise
16 L
20 L
High
efficiency
Standard
efficiency
24 L
26 L
EF24
VT16
VT20
VT24
EF250
VT26
HD200
High
efficiency
HD250
EFi250
HDi200
Standard
efficiency
Please note
32 L
Service and maintenance
For reliable operation Rinnai continuous flow water heaters in residential applications
should be serviced every two years. For commercial applications Rinnai has a recommended
commercial maintenance and servicing schedule. This is available on request or via
www.rinnai.co.nz.
6 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Model selection for residential applications
When specifying residential hot water applications there are some basic
questions that you need to ask in order to correctly design a system. You also
need to bear in mind the future requirements of the building. The key point
is water heating solutions should be designed to the number of hot water
outlets and not the number of people.
Which model?
Questions to ask to
determine which model(s)
may be suitable.
the Rinnai INFINITY closer to
the kitchen sink where there
is an immediate demand for
hot water.
• How many bathrooms?
If bathrooms are situated at
opposite ends of the house
two Rinnai INFINITY units
may be required.
• Where are the bathrooms
and other hot water outlets
positioned in the house?
• How often will the
hot water outlets run
simultaneously?
• What type of tapware is
installed?
• What is the location of the
property in New Zealand?
How many bathrooms?
A VT16 or VT20 unit may be
suitable for a one bathroom
home, whereas a two or three
bathroom home will need a
larger Rinnai INFINITY, or even
multiple units.
Where are the bathrooms
and other hot water outlets
positioned in the house?
Where are the bathrooms
and other hot water outlets in
relation to where the Rinnai
INFINITY is to be installed? In
most cases it is better to site
How often will the
hot water outlets run
simultaneously?
How likely will hot water
outlets, such as showers, be
used at the same time.
Scenario one: Two bathroom
home with a couple who
rarely use the second
shower—a VT20 may be
suitable.
Scenario two: Two bathroom
home with a family of five
who fight for two showers in
the morning—a larger Rinnai
INFINITY would be needed.
What type of tapware is
installed?
There is a large range of
tapware in the market, some
with very high flow rates. The
main consideration is the
type of shower rose installed
and how many litres it puts
out—typical flow rates for
showers is around 8-10 L/min.
This needs to factored when
determining the required
Rinnai INFINITY model.
To measure the flow rate
of a shower, hold a bucket
under the shower rose for
one minute and measure the
volume of water.
Location of the property in
New Zealand?
Ambient water temperatures
will vary throughout the
country, for example, the
South Island in winter will be
much colder than the North
Island. This is important when
determining the incoming
water temperature and the
temperature rise required at
the hot water outlet as this
will affect the output of the
unit. For more information
refer appendix 1 on p. 40.
Use the New Zealand map on
the next page to determine
the location of the property
in relation to the climate
zone.
Budget, size of house, number of hot water outlets, and hot water requirements all factor
in determining the right continuous flow hot water system for your home. Use the product
selector table on the next page to work our which model is right for you.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 7
Model selector
1. Determine the hot water outlets that will run simultaneously in your house, and list the flow rates
against them.
Hot water outlet Typical flow rate*
Bathroom
9 L per minute
Worked example
9L
Bathroom two
9 L per minute
9L
Kitchen
6 L per minute
6L
Laundry
6 L per minute**
Other
Allow 6 L per minute
TOTAL
24 L
* You can check your own actual water flow rates by holding a bucket under the hot water outlet for a minute and
measuring the volume.
** A number of washing machines, particularly front loaders, have a cold-only connection as they have an internal
heater. Hot water in this instance, as it isn’t required, would not need to be factored into the calculation.
2. Total the maximum simultaneous water flow, e.g. 24 litres.
3. In the column for geographical region move down until a number bigger than your total appears.
Warm (L/min) Mild (L/min) Cool (L/min) VT model
16
13
11
16
HD model
200
EF model
24
20
17
14
20
200
24
24
20
17
24
200
24
26
22
19
26
200
250
30
26
22
26
250
250
32
27
23
250
250
4. Read across to the model, e.g. for 24 litres per minute in the mild zone a VT26 is selected. If you
find the flow rate is greater than the figures listed in the table please contact Rinnai for advice.
Multiple units may be required or an alternative hot water heating solution.
*RADIUS
Warm
Mild
Cool
8 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Location of Rinnai INFINITY units
To provide safe and effective water heating it is important to adhere to all
relevant gas installation standards. Check the guidelines detailed in this guide.
If in any doubt it pays to consult a licensed gasfitter to double check where the
unit can be located.
General installation
considerations
The Rinnai INFINITY should be
placed as close as possible to
the most frequently used hot
water outlet(s) to minimise
the delay for hot water. In
most cases it is better to site
the Rinnai INFINITY closer to
the kitchen where there is an
immediate demand for hot
water.
For installations where
the distance between the
water heater and outlets is
considerable, a flow and return
system with a buffer tank, can
be used to minimise the waiting
time for hot water delivery.
Alternatively multiple units can
be strategically placed to serve
different outlets.
Operating noise
Some people are susceptible to
low level noise. Rinnai INFINITY
units operate at 49 dB(A).
This needs to be considered if
locating the appliance near a
bedroom.
Easy access
All continuous flow water
heaters must be installed to
ensure access can be gained
for servicing and repair,
without hazard or undue
difficulty.
If mounting appliances at
height the owner must arrange
permanent and safe access,
or provide another means of
access such as scissor or boom
lifts.
External models
External models are designed
for outdoor installations only.
They must be located above
ground where the products
of combustion can be
naturally dispersed. They
should not be in enclosed
areas as the unit can be
choked by its own flue gases,
which will cause the unit
to malfunction. Refer to
the general flue clearances
diagram on the next page.
Internal models
Internal models are designed
for indoor installations only.
External models must be
mounted on a vertical structure
with the water and gas
connections on the underside
pointing downwards.
They are a flued appliance—
flue components purchased
separately. They may be
installed in an enclosure if the
requirements of AS/NZS 5601.1
are satisfied. An enclosure is
defined as a compartment,
enclosed area or partitioned
off space primarily used
for the installation of the
appliance.
For internal units we
recommend a 600 mm
clearance for servicing
access. This can be reduced
to 50 mm if installed in
a cupboard, refer to the
general access clearances
diagram on the next page.
Internal models must be mounted
on a vertical structure with the
water and gas connections on the
underside pointing downwards.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 9
General clearances
The following diagrams have been provided to assist in determining where,
and if a continuous flow water heater can be installed. If in doubt, consult a
licensed gasfitter who will have access to the Gas Installation standards.
External models: General flue clearances
G
Dim.
Infinity VT,
Infinity HD250
HD200, EF models models
A
Min. 300 mm
Min. 500 mm
B
Min. 300 mm
Min. 500 mm
C
Min. 1.5 m
Min. 1.5 m
D
Min. 500 mm
Min. 500 mm
E
Min. 300 mm
Min. 300 mm
F
Min. 300 mm*
Min. 300 mm*
G
Min. 300 mm
Min. 300 mm
Other clearances
Below eaves, balconies, and other projections,
minimum 300 mm.
From a gas meter, minimum 1000 mm.
From an electricity meter or fuse box, minimum
500 mm.
* Rinnai recommend 1.5 m to give enough clearance for the
pipe work, and to safely expel flue gases.
Internal models: General access clearances
75 mm
min.
75 mm
min.
600 mm min.
(50 mm min if in a cupboard)
For internal units we recommend a 600 mm clearance for
servicing access. This can be reduced to 50 mm if installed in a
cupboard.
Example of an HDi200 internal installed in a
cupboard - Rinnai Auckland showroom.
10 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY
Product
specification
pages
Rinnai INFINITY VT specification summary
Rinnai INFINITY VT external codes
Gas Type
VT16
VT20
NG
INFVT16N
INFVT20N
VT24
INFVT24N
VT26
INFVT26N
LPG
INFVT24L
INFVT26L
INFVT16L
INFVT20L
Description
Continuous flow gas hot water heaters (with inbuilt frost protection), preset to 55 °C, for external
residential applications. Suitable for mains and medium pressure systems. Electronic ignition—
requires electricity to operate.
Infinity VT (Valve Technology) uses a new manifold system, which at lower flow rates, precisely
matches water supply to flow demand at the required temperature.
Hard or acidic water will need to be treated to use this product.
VT20
VT24
VT26
REU No.
VR1620WG
VR2024WG
VR2426WG
VR2626WG
Colour
White
White
White
White
Hot
R½ (15 mm)
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Cold
R½ (15 mm)
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Gas
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Efficiency
81%
80%
80%
80%
Energy star
rating
6.2 star energy
equivalent
6.1 star energy
equivalent
6.0 star energy
equivalent
6.1 star energy
equivalent
Hot water
capacity
1.5-16 L/min
1.8-20 L/min
1.8-24 L/min
1.8-26 L/min
Nominal water
capacity*
16 L/min
960 L/h
20 L/min
1200 L/h
24 L/min
1440 L/h
26 L/min
1560 L/h
Input on max.
125 MJ/h
160 MJ/h
188 MJ/h
199 MJ/h
Output on max. 29.6 kW
34.9 kW
42.1 kW
44.2 kW
Water supply
120-1000 kPa
160-1000 kPa
180-1000 kPa
130-1000 kPa
Weight
15 kg
16 kg
17 kg
17 kg
Connections
VT16
* Nominal water capacity at a 25 °C rise
12 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY VT dimensions (mm)
350
194
270
530
571
H
I
A
C E
B
D
F
G
All VT models
A
Hot water outlet from wall
87
B
Hot water outlet from centre
105
C
Cold water inlet from wall
68
D
Cold water inlet from centre
10
E
Gas connection from wall
77
F
Gas connection from centre
83
G
Gas: Length gas connection from base
40
Cold: Length of cold water inlet from base
50
Hot: Length of hot water outlet from base
39
H
Electrical connection from centre
45
I
Electrical connection from wall
128
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 13
Rinnai INFINITY HD specification summary
Rinnai Infinity HD codes
Gas Type
HD200 external
NG
INFHD200HNCN
HDi200 internal HD250 external
INFHD200FFNCFN INFHD250HNCN
LPG
INFHD200FFNCFL INFHD250HNCL
INFHD200HNCL
Description
Continuous flow gas hot water heaters (with inbuilt frost protection) for residential and
commercial applications. Suitable for mains and medium pressure systems. Electronic ignition—
requires electricity to operate. The internal unit is a room sealed appliance.
The HDi200 and HD250 are preset to 55 °C, the HD200 is preset to 75 °C. All HD units can be
preset to deliver higher hot water temperatures making them ideal for commercial applications.
Hard or acidic water will need to be treated to use this product.
HDi200 internal
HD250 external
REU No.
VRM2632WC
VR2632FFUG
VR3237WG
Colour
Silver
Silver
Silver
Hot
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Cold
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Gas
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Efficiency
82%
83%
81%
Energy star rating
5.9 star equivalent
6.1 star equivalent
5.9 star equivalent
Hot water capacity 2.4-30 L/min
2.4-32 L/min
2.4-37 L/min
Nominal water
capacity*
26 L/min
1560 L/h
26 L/min
1560 L/h
32 L/min
1920 L/h
Input on max.
199 MJ/h
195 MJ/h
250 MJ/h
Output on max.
47 kW
45.1 kW
59.9 kW
Water supply
130-1000 kPa
140-1000 kPa
200-1000 kPa
Weight
21 kg
21 kg
29 kg
Connections
HD200 external
* Nominal water capacity at a 25 °C rise
14 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY HD dimensions (mm)
A
B
O
K
N
L E
C D
G I
F
M
H
J
N.B: This is a generic connections drawing to
highlight what dimensions are displayed in the
below table. For reference to the actual position
of each connection for each model refer images in
appendix 4 on p. 48.
HD200 ext.
VRM2632WC
HDi200 int.
VR2632FFUG
HD250 ext.
VR3237WG
A
Width
350
350
470
B
Depth
250
235~275
244
C
Height - unit
600
600
600
D
Height - including brackets
636
641
644
E
Hot water outlet from wall
95
91~131
115
F
Hot water outlet from centre
110
110
61
G
Cold water inlet from wall
74
70~110
99
H
Cold water inlet from centre
I
Gas connection from wall
103
99~139
61
J
Gas connection from centre
89
89
110
K
Electrical connection from centre
21 (right of
centreline)
21 (right of
centreline)
2 (right of
centreline)
L
Electrical connection from wall
160
160~200
100
41
41
41
Cold: Length of cold water inlet from base
51
51
51
Hot: Length of hot water outlet from base
42
42
42
M Gas: Length gas connection from base
27 (left of centreline) 27 (left of centreline)
52
N
Flue spigot centreline (from wall)
N/A
95~135
N/A
O
Height of flue spigot from base of unit
N/A
85
N/A
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 15
Rinnai INFINITY EF specification summary
Rinnai Infinity EF codes
Gas Type
EF24 external
NG
EFF24NCN
EFi250 internal
INFEF250FFN
EF250 external
INFEF250N
LPG
INFEF250FFL
INFEF250L
EFF24NCL
Description
High efficiency continuous flow gas hot water heaters (with inbuilt frost protection), preset
to 55 °C, for residential and commercial applications. Suitable for mains and medium pressure
systems. Electronic ignition—requires electricity to operate. The internal unit is a room sealed
appliance.
EF250/EFi250 units can be preset to deliver higher hot water temperatures making them ideal
for commercial applications.
Hard or acidic water will need to be treated to use this product.
EFi250 internal
EF250 external
REU No.
K2430WG
KM3237FFUD
KM3237WD
Colour
White
Gunmetal Grey
Gunmetal Grey
Hot
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Cold
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Gas
R¾ (20 mm)
R¾ (20 mm)
R¾ (20 mm)
Condensate R½ (15 mm)
R½ (15 mm)
R½ (15 mm)
Connections
EF24 external
Efficiency
95%
95%
95%
Energy star rating
6.8 star energy equivalent
7.0 star energy equivalent
7.0 star energy equivalent
Hot water capacity
2.3-30 L/min
1.5-37 L/min
1.5-37 L/min
Nominal water
capacity*
24 L/min (1440 L/h)
32 L/min (1920 L/h)
32 L/min (1920 L/h)
Input on max.
162 MJ/h
211 MJ/h
211 MJ/h
Output on max.
43 kW
55.6 kW
55.6 kW
Water supply
240-1000 kPa
240-1000 kPa
240-1000 kPa
Weight
27 kg
32 kg
32 kg
* Nominal water capacity at a 25 °C rise
16 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY EF dimensions (mm)
A
B
P
N
O K
C D
E
G
F
I
H
J
L
M
N.B: This is a generic connections drawing to
highlight what dimensions are displayed in the
below table. For reference to the actual position
of each connection for each model refer images in
appendix 5 on p. 49.
EF24 external
K2430WG
EFi250 internal
KM3237FFUD
EF250 external
KM3237WD
A
Width
350
470
470
B
Depth
277
257~307
283.1
C
Height - unit
600
654
654
D
Height - including brackets
644
721.6
721.6
E
Hot water outlet from wall
164.5
100~140
100
F
Hot water outlet from centre
100
100
100
G
Cold water inlet from wall
83
64.6~104
64.6
H
Cold water inlet from centre
53 (left of centreline)
27.7
27.2
I
Gas connection from wall
70.5
89~129
89
J
Gas connection from centre
25
103.2
103.2
K
Condensate outlet from wall
33
122.6
122.6
L
Condensate outlet from centre
132
195
195
M
Gas: Length gas connection from base
51
40.2
40.2
Cold: Length of cold water inlet from base
62
50.2
50.2
Hot: Length of hot water outlet from base
41
41.2
41.2
Condensate connection length from base
24
22.4
22.4
10 (right of centreline)
49
49
N
Electrical connection from centre
O
Electrical connection from wall
175
200~240
200
P
Flue spigot centre line from wall
N/A
155~195
N/A
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 17
Rinnai INFINITY accessories summary table
Compact
controller
Kitchen
Deluxe
controller
Bathroom
Deluxe
controller
Wireless controller
& transceiver
Composite
recess box
Metal recess
box
Water Heater
On/Off
Temp. Volume
Max Temp.
Maintenance
Entry
RINNAI
Controllers
MC
No. 1
No. 2
No. 3
p. 28
p. 28
p. 28
p. 28
p. 30
p. 31
VT16
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
R1406
R1405
VT20
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
R1406
R1405
VT24
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
R1406
R1405
VT26
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
R1406
R1405
HD200
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
R1407
HDi200
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
X
HD250
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
R1407
EF24
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
R1407
EFi250
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
X
EF250
MC912A
MC100V1Z
BC100V1Z
MC503S & MC503M
X
X
VT range
HD range
EF range
18 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Pipe cover
Security
bracket
Sideways
Upwards flue
flue diverter
diverter
HD error
indication
switch
EZ connect
p. 32
p. 33
p. 34
p. 35
p. 36
p. 37
VT16
R1385
ACC1395
FDS16
FDU16
X
X
VT20
R1385
ACC1395
FDS20
FDU20
X
X
VT24
R1385
ACC1395
FDS24
FDU24
X
X
VT26
R1385
ACC1395
FDS24
FDU24
X
X
HD200
R1408SC
ACC1395
X
X
R1070
REUEZC
HDi200
R1408SC
ACC1395
X
X
R1070
REUEZC
HD250
R1402SC
ACC1395
X
FDU32
R1070
REUEZC
EF24
R1408
ACC1395
X
X
X
X
EFi250
R1409
ACC1395
X
X
R1070
REUEZC
EF250
R1409
ACC1395
X
X
R1070
REUEZC
VT range
HD range
EF range
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 19
Rinnai INFINITY internal flueing options
The flueing for internal water heaters is a coaxial design. It has a stainless steel
inner pipe to discharge products of combustion and a thermoplastic outer
pipe for air supply to the appliance.
Each Rinnai INFINITY water heater is flued individually, refer flueing options diagram below.
3
1
2
4
Direct flueing: For direct flue installations through an external wall using the direct flue kit
FFSSKIT—maximum wall thickness 430 mm (EFi250) and 485 mm (HDi200).
Horizontal extension flueing: For flue installations through an external wall using the
direct flue kit FFSSKIT and additional lengths of pipe.
Vertical straight flueing: Installations where the internal unit is flued vertically through the
roof.
Combination flueing: Installations using a combination of horizontal and vertical flueing.
20 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY flueing guidelines
Flue gases can reach temperatures up to 200 °C. The flue terminal is to
terminate in a location so as not to cause a nuisance, in accordance with
AS/NZS 5601.
Flue support
Ensure the flue is supported independently
of the appliance by use of suitable clips or
brackets, in accordance with AS/NZS 5601.
Appropriate standoff brackets are supplied
with each FFSSROOFCOWL and FFSSPIPE1000.
Multiple flues
Ensure minimum distances, as shown below
are maintained.
FFSSROOFCOWL
A
Min. clearance 500 mm
Flue length
The chart below highlights the maximum flue
length and number of bends.
Number of 90 ° Bends
0
1
2
3
A
4
1
2
A:
A:
Flue Length (m)
3
4
HDi200
EFi250
350 mm
470 mm
5
6
7
A
9
11
13
15
Max. flue length
FFSSKIT
A
Each terminal is to be terminated at the same
vertical height, refer images below—please
note these images show our older style
terminals, which have since been updated.
Vertical terminations.
To ensure products of combustion are cleared,
adequate clearance from the building is
required.
The flue cowl should have a 500 mm clearance
from any part of the building. This also applies
to steeped and pitched roofs, which should be
clear of the ridge line.
Lesser clearances may provide perfectly
adequate flue systems depending on the
installation. Minimum clearances are shown in
AS/NZS 5601.
Older style roof cowls all
terminating at the same
height
Older style horizontal
terminals all terminating
at the same height
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 21
Direct flueing using the FFSSKIT
For installations where the Rinnai INFINITY is mounted directly on the inside of
an external wall with a maximum wall thickness of 430 mm (EFi250) and
485 mm (HDi200).
430 mm max. EFi250
485 mm max. HDi200
430 mm max. EFi250
485 mm max. HDi200
140 mm hole
140 mm hole
2 ˚ fall
FFSSKIT contains
- 90 ° bend
- horiz. flue terminal
- int. rubber white wall trim
- ext. rubber black wall trim
2 ˚ fall
Approx.
150 mm
45 mm min.
Horizontal flues MUST
SLOPE 20 mm per metre
to the termination point.
Ensure condensate drains
appropriately.
580 mm max.
580 mm max.
Horizontal extension flueing
For installations where the Rinnai INFINITY gas hot water heater is mounted
against an internal wall and the flueing needs to be extended for a longer
distance horizontally to exit an external wall.
Condensate direction
2 ˚ fall
to terminal
Condensate direction (2 ˚ fall to appliance)
FFSSCOND (HDi200 only)
To sanitary waste
22 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Use FFSSKIT as a starting point and
customise with flue pipe (FFSSPIPE1000).
More than one flue pipe (can be cut to
size) may be required. Total flue length
can be up to 13 m.
Condensate can be handled in two ways:
1. 2° fall to the termination point
(20 mm per metre), ensure
condensate drips will not cause
damage.
2. Condensate drains back to the unit—
HDi200 unit will need a condensate
trap kit (FFSSCOND).
Vertical straight flueing
For installations where the Rinnai INFINITY needs to be flued vertically
through the roof.
FFSSROOFCOWL
(with roof protectors fitted)
For HDi200 units, a condensate trap (FFSSCOND) is
required for flue lengths over 1.5 m. Total flue length
can be 15 m.
FFSSPIPE1000
Additional lengths can be
added as required (can be
cut to size)
FFSSCOND
(HDi200 only)
To sanitary waste
Combination flueing
Combination of vertical and horizontal flueing. HDi200 unit will need a
condensate trap kit (FFSSCOND).
If starting horizontally and finishing horizontally, use
FFSSKIT as a starting point and customise.
FFSSROOFCOWL
(with roof protectors fitted)
If starting horizontally and ending vertically or vice
versa, individual flue components will need to be
ordered. Flueing must start with a FFSSBEND90 or
FFSSPIPE1000 (can be cut to size).
FFSSPIPE1000
e)
Condensate direction (2 ˚ fall to applianc
FFSSCOND (HDi200 only)
To sanitary waste
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 23
Rinnai INFINITY flue components
All the major flue components are constructed of a PVC outer and a stainless
steel inner. These have zero clearance from combustibles.
All dimensions are in mm.
90 degree bend (FFSSBEND90)
130
5
10
85
114
66
64.5
80
45 degree bend (FFSSBEND45) - sold as a pair
85
5
92
5
165
80
85
166
176
66
64.5
10
10
80
(As a 90° OFFSET)
(As a 45° OFFSET)
Flue pipe (FFSSPIPE1000) - can be cut to size, includes a Munzing ring to support the flue
10
85
PU
80
125
5
980
Condensate trap kit (FFSSCOND) for the HDi200
End-to-end approx. 180 mm
Hose is approx. 516 mm
I.D = 20 mm
The FFSSCOND is not needed for the EFi250 as there is a different method to drain condensate (that doesn’t require additional flue
components). For further information refer to the Rinnai INFINITY installation manual.
24 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Roof cowl for vertical installations (FFSSROOFCOWL) - can be cut to size
Includes two black injection UV roof protectors, shown
below for covering and protecting the white flue pipe
from UV damage. Also includes a flue pipe clamp to
support the flue.
Black powder
coat cast
aluminium
483
953
Black
PVC plastic
10
White
PVC plastic
Roof protector dimensions
Length approx. 197 mm
Joined length approx. 347 mm
Diameter 140 mm
80
125
Direct flue kit for horizontal installations (FFSSKIT) - can be cut to size
565
13
30
30
5
10
85
114
225
125
80
130
66
64.5
150
80
Black and white wall trims that come with the kit
225
125
Thickness 1 mm
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 25
This page intentionally left blank
Rinnai INFINITY
Accessories
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 27
Rinnai INFINITY digital controllers
With a Rinnai INFINITY digital controller you choose your own personalised settings. Just select
the water temperature you want (37-55 °C) in up to four different locations. This means you can
set water at a safe temperature in the bathroom (a great safety feature), then set it higher, if you
wish, in the kitchen and laundry.
Additional benefits
• Reduces temperature fluctuation when other taps are used in the house.
• Receive an extended warranty, Rinnai INFINITY units installed with digital controllers receive
an extra two years warranty.
• View and troubleshoot any problems by using the controller as a diagnostic tool, for example
error code 11 when there is no gas.
Location
Water controllers are water resistant, however, durability is improved when positioned outside
the shower recess. In other areas they must be installed at least 400 mm above the highest part
of the sink, basin, or bath.
Maximum number of controllers
For residential applications a maximum of four controllers can be fitted, please note important
points regarding controller combinations below.
• Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or
Wireless Controller.
• Up to TWO Bathroom Deluxe Controllers can be installed.
• The fourth controller in any installation must be a Compact or Wireless Controller.
Each controller can be individually programmed, however the water heater can only deliver one
set temperature at any time. For example, John is in the shower and has set the controller to
42 °C, Jane uses the kitchen tap at the same time—the water temperature coming out of the
kitchen tap will also be 42 °C (or lower if using a mixer and adding cold water). Jane can only
change the programmed temperature once John is out of the shower.
Wired controller cables
All wired controllers come with 15 m of cable. Additional cable can be ordered:
• R1069
• R1369
Please note
Additional cable for the Compact and Bathroom Deluxe controllers
Additional cable for the Kitchen Deluxe controller
Rinnai controllers cannot be used with Rinnai INFINITY units connected to a
solar system, or when a Rinnai iHeat is installed as the preset dip switch setting
on the Rinnai INFINITY needs to be adjusted from 55 °C to 75 °C.
28 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Compact Controller
• Smallest, most economical model
• Off white with a grey touch pad
• For use anywhere in the house
• Dimensions: H-120 mm, W-90 mm, D-20 mm
Code: MC912A
Bathroom Deluxe Controller
• Bathfill set-and-forget function
• Silver
• For use in bathrooms only
• Dimensions: H-97 mm, W-195 mm, D-22 mm
Code: BC100V1Z
Bathfill function lets you set the desired water level and
temperature and walk away. Also ideal as a water saver as the
temperature and volume of water to be used in the shower can
be set—great if you have teenagers.
A voice message will let you know when your bath is ready. If you
have other deluxe controllers around the house, the message will
play on all of them.
Please note: Bathfill function unable to be used if manifolding
Rinnai INFINITY units together.
Kitchen Deluxe Controller
• Works in conjunction with the Bathroom Deluxe controller
• Silver
• For use in kitchens and laundries
• Dimensions: H-120mm, W-128 mm, D-20 mm
Code: MC100V1Z
Wireless Controller
• Wire free installation (battery operation)
• Silver (controller) and white (transceiver)
• For use anywhere in the house
• Controller dimensions: H-142mm, W-66.6 mm, D-28 mm
Codes
MC503S (controller)
MC503M (transceiver)
No need to run wires in the wall or ceiling cavity—can be easily
installed into existing houses, making it ideal for renovation
projects.
Can be used up to 50 m away from the water heater (maximum
distance between the transceiver and Rinnai INFINITY is 20 m).
Can be combined with a wired controller system.
If ordering a wireless controller, you will need to order the
controller and the transceiver—up to four controllers can be
connected.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 29
Rinnai INFINITY composite recess box
Description
The Rinnai composite recess box is an affordable alternative to
the metal recess box for housing the Rinnai INFINITY unit, pipe
work, and power supply.
The composite recess box enables a Rinnai external continuous
flow water heater to be partially recessed into an external wall,
covered and out of sight.
Colour: Beige—can be painted to match the exterior cladding.
Positioning
A Rinnai INFINITY unit inside a recess box operates at a slightly
louder level than a Rinnai INFINITY installed on an outside wall.
Please bear this in mind when positioning near a bedroom as
the operating noise could affect some people.
Suitability
• Outdoor installations only.
• Installation with VT16-VT26 external units.
Code: R1406
• New construction or major renovation—installation needs
to commence during the framing stage before internal
linings, claddings, or building wrap is applied.
• Installation where the minimum framing depth is 88 mm.
The composite recess box is not suitable for fire rated walls.
Building code compliance
Territorial authorities may have their own additional requirements
regarding this type of installation as it is similar in detail to
installing windows. If in doubt over compliance with building
codes, it is advisable they are consulted prior to installation.
1086
1023
1078
118
69
Dimensions
440
12
Approximate depth with cover on - 240 mm
30 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
446
Rinnai INFINITY metal recess box
Description
The Rinnai metal recess box enables an external Rinnai
INFINITY unit to be recessed, either fully or semi-recessed into
an external wall, behind a door and out of sight.
Construction is folded galvanised steel, powder coated white.
Colour: White—can be painted to match the exterior cladding.
Positioning
A Rinnai INFINITY unit inside a recess box operates at a slightly
louder level than a Rinnai INFINITY installed on an outside wall.
Please bear this in mind when positioning near a bedroom as
the operating noise could affect some people.
Suitability
• Outdoor installations only.
• Installation with the following external Rinnai INFINITY units:
- VT16-VT26
(use R1405)
- HD200, HD250, EF24 (use R1407)
Building code compliance
Territorial authorities may have their own additional requirements
regarding this type of installation as it is similar in detail to
installing windows. If in doubt over compliance with building
codes, it is advisable they are consulted prior to installation.
Dimensions
R1405
• Height 944 mm
• Width
417 mm
• Depth
205 mm
R1407
944 mm
514 mm
270 mm
Height
Codes
R1405VT16-VT26
R1407 HD200, HD250, EF24
• New construction or major renovation—installation needs
to commence during the framing stage before internal
linings, claddings, or building wrap is applied.
Width
h
Dept
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 31
Rinnai INFINITY pipe covers
Description
If you want a clean smooth finish to the installation, the Rinnai
INFINITY pipe cover can be used to cover pipes, valves, and
even the external power point1.
There are five pipe cover kits that vary in size and colour
according to the type of Rinnai INFINITY being installed.
1
If the power point is located inside the cover it must comply with
AS/NZS Wiring rules.
Colour
White:VT models and EF24
Silver: HD and EF250 models
Dimensions (mm)
W
Codes
R1385
VT16-VT26
R1402SCHD250
R1408
EF24
R1408SCHD200/HDi200
R1409
EF250/EFi250
H1
H2
D
Pipe cover
R1385
H1
394
H2
438
D
167
W
334
R1402SC
394
438
230
453
R1408
394
448
230
334
R1408SC
394
448
230
334
R1409
450
470
240
460
32 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY security bracket
Description
A sturdy security bracket can be installed to act as a deterrent
to thieves. Consisting of two U-shaped 2 mm powder coated
galvanised steel plates, which interlock through the lower
bracket of the Rinnai INFINITY. The bracket is secured with a
padlock (not included).
How it works
The bracket prevents access to the bolts fixing the unit to
the wall, this locks the lower Rinnai INFINITY continuous flow
water heater in place, and prevents the unit from being quickly
removed from the wall.
Code: ACC1395
Colour: Off-white—can be painted.
Suitability
For all Rinnai INFINITY continuous flow gas water heaters—can
be retrofitted to existing installations.
Can be installed on all cladding systems like weatherboard,
brick, and plaster. Can also be installed inside a recess box.
Ideal for
Builders installing gas units on new homes that need to protect
the Rinnai INFINITY before the home is sold or handed over to
the new owners.
Dimensions:
• Height 70 mm
• Width
190 mm
• Depth
33.5 mm
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 33
Rinnai INFINITY sideways flue diverter
Description
The Rinnai INFINITY sideways flue diverter is an accessory
that can be fitted to an external Rinnai INFINITY water heater.
It is designed to expel combustion products in a sideways
direction.
The flue diverter is fitted with screws to the flue terminal of the
water heater.
Construction: Stainless steel
Specific applications
Noise reduction, in particular with the larger Rinnai INFINITY
models, where the unit is positioned close to a neighbouring
property.
Codes
FDS16 for VT16
FDS20 for VT20
FDS24 for VT24 and VT26
Where there may be an obstruction such as a tree, fence,
wall, or other structure, that even though the Rinnai INFINITY
is installed with the required clearances, will perform
more efficiently if the flue gases are cleared away from the
obstruction.
Where clearance to an openable window or other building
structure is tight, the clearance shifts to the point of discharge
(close to the edge of the water heater case).
j
m
385 mm
140 m
Openable
window
75 mm
Approximate depth when
mounted on the unit 75 mm
50 mm
Sideways flue
diverter—ensure
1500 mm clearance
n
j and n relate to minimum clearancs required for
balanced flue terminals from AS/NZS 5601.1
Suitability
• Externally mounted Rinnai INFINITY continuous flow water
heaters NOT installed in a recess box.
• External SINGLE water heater applications only (can be
installed for left and right handed installations).
• Balconies, patios or other enclosed areas where products
of combustion can be rapidly dispersed into the open-air.
Important
The flue diverter MUST remain as a permanent fixture as removal could mean
the water heater position no longer complies with AS/NZS 5601.1.
34 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY upwards flue diverter
Description
The Rinnai INFINITY upwards flue diverter is an accessory
that can be fitted to an external Rinnai INFINITY water heater.
It is designed to expel combustion products in an upwards
direction.
The flue diverter is fitted with screws to the flue terminal of the
water heater.
Construction: Stainless steel
Specific applications
Noise reduction, in particular with the larger Rinnai INFINITY
models, where the unit is positioned close to a neighbouring
property.
Where there may be an obstruction such as a tree, fence,
wall, or other structure, that even though the Rinnai INFINITY
is installed with the required clearances, will perform more
efficiently if the flue gases are expelled upwards and away from
the obstruction.
Where there are multiple units installed that are positioned
facing each other—there is the potential for the units to
suffocate from the flue gases of the unit directly opposite.
With an upwards flue diverter the flue gases can be expelled
upwards and away from the units.
Suitability
• Externally mounted Rinnai INFINITY continuous flow water
heaters NOT installed in a recess box.
• Balconies, patios or other enclosed areas where products
of combustion can be rapidly dispersed into the open-air.
Important
The flue diverter MUST remain as a permanent fixture as removal could mean
the water heater position no longer complies with AS/NZS 5601.1.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 35
Rinnai INFINITY HD error switch
Description
The Rinnai INFINITY HD water heater error indication switch
is a volt-free, normally open switch. The switch will shift to
a closed position when there is an active error in the water
heater.
The switch is intended to be connected to a monitoring system
such as a building management system, or other visual or
audible error indication system.
Suitability
Suitable for commercial applications, and can be used with the
following water heaters:
Code:R1070
•
•
•
•
HD200 external
HDi200 internal
EFi250 internal
EF250 external
System design
System designers should note that some errors will reset to an
inactive (open) state under particular conditions. It is important
that this is clearly understood when developing monitoring and
response systems.
Switch rating
The HD error indication switch will switch the following
maximum loads:
• Voltage (AC or DC)
24 Volts
• Current1 Amp
Systems requiring loads greater than this should be configured
via an external relay.
36 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY EZ connect cable
Description
The installation of a Rinnai EZ connect cable allows a maximum
of two Rinnai INFINITY water heaters (specific models only) to
be connected together so they function as one large unit.
The two water heaters can be installed 5-460 mm apart. The
maximum distance (460 mm) is so the cable will reach between
the two units, and to prevent temperature fluctuations when
the water is turned on and off.
Code:REUEZC
Installation
Installation by a certified tradesperson is required.
Suitability
Can be used with the following water heaters:
• HD200 external
• HDi200 external
• HD250 external
• EFi250 external
• EF250 external
Please note: The bathfill function on the Bathroom Deluxe
controller will not work if an EZ connect cable has been fitted.
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 37
Rinnai INFINITY manifolding
Description
Rinnai INFINITY units can be manifolded together, in banks of
five (up to 25 individual units), by connecting them together in
parallel to enable a greater hot water flow rate than is possible
with a single unit.
A manifold electronic control system links each Rinnai
INFINITY unit in the system and will turn on each unit as
required. The system is designed to ensure gas is not wasted
and that an endless supply of hot water is always available.
Codes
REUMSB REUMSBMB REUMSBC1 REUMSBC2 (int. master)
(ext. master)
(slave)
( joiner )
Suitability
• VT24 and VT26 models (in residential applications)
• All HD models
• All EF models
Please note:
• Rinnai do not specify manifolded systems for smaller VT units
• For commercial applications use HD or EF250 models
How it works
A master (located internally or externally) and subcommunication PCB is installed in the first unit, other units only
have the sub-communication PCB (slave cable) installed. The
master communication PCB receives information about flow rates
from the PCB of each unit and balances the load on each unit.
Random selection of the units required to supply the flow
demand means that all units share the workload evenly.
All information is transmitted via communication cables to the
slave units. The master control also has an inbuilt fault detection
system and will allocate a replacement unit should one fail.
Manifold components
• REUMSB
Internal (connection made inside the unit) master manifold
kit.
• REUMSBMB
External (connection made outside the unit) master manifold
kit.
• REUMSBC1
Manifold slave cable.
• REUMSBC2
Joiner for greater than five manifolded Rinnai INFINITY units.
Refer appendix 3 ‘Manifolding components what to use where’
to determine manifolding components required.
38 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Appendices
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 39
Appendix 1
Water flow and gas usage
When calculating the model of the Rinnai INFINITY required it is important
to determine what the incoming water temperature will be. This is usually
calculated on the worst case scenario (winter). For example:
• Northland and Aucklanduse 15 °C
• Bay of Plenty, Gisborne, and Hawke’s Bay
use 10 °C
• Waikato, Taranaki, Wanganui, Manawatu, Wairarapa,
use 5 °C
Wellington, and South Island
Degree rise
In the specification pages for the Rinnai INFINITY water heating range we express a parameter
called ‘Nominal water capacity’. This means that at a 25 °C rise, the unit will produce a certain
number of litres per minute of hot water. For example:
• The VT26 external will produce 26 litres per minute at a 25 °C rise
• The VT24 external will produce 24 litres per minute at a 25 °C rise
Using the example above, for incoming water of 10 °C and a required temperature rise of 55 ° C,
the VT26 external will produce 14.4 litres per minute at a 45 °C rise (55-10), and the VT24 external
will produce 13.3 litres per minute at a 45 °C rise.
Water flow and gas usage tables
Use these tables to calculate model performance based on the incoming water temperature,
and the required outlet temperature.
40 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY VT
Temperature preset to 55 °C or less (mixed water)
5 °C temperature rise
VT
Approx. min. to L/min
L/h
Pressure
Approx. gas
model max. gas input
loss
consumption
(MJ/h)
through
(MJ/h)
unit (kPa)
VT16 10-125
20.0
1200
75
31.0
VT20 13-160
24.0
1440
120
37.2
VT24 13-188
26.0
1560
170
40.3
VT26 13-199
26.0
1560
200
40.3
15 °C temperature rise
VT16 10-125
20.0
1200
75
93.0
VT20 13-160
24.0
1440
120
111.6
VT24 13-188
26.0
1560
170
120.9
VT26 13-199
26.0
1560
200
120.9
25 °C temperature rise
VT16 10-125
16.0
960
75
125.0
VT20 13-160
20.0
1200
120
160.0
VT24 13-188
24.0
1440
140
188.0
VT26 13-199
26.0
1560
200
199.0
35 °C temperature rise
VT16 10-125
11.4
686
44
125.0
VT20 13-160
14.3
857
64
160.0
VT24 13-188
17.1
1029
70
188.0
VT26 13-199
18.6
1114
130
199.0
45 °C temperature rise
VT16 10-125
8.9
533
29
125.0
VT20 13-160
11.1
667
42
160.0
VT24 13-188
13.3
800
40
188.0
VT26 13-199
14.4
867
80
199.0
10 °C temperature rise
L/min
L/h
Pressure
Approx. gas
loss
consumption
through
(MJ/h)
unit (kPa)
20.0
1200
75
62.0
24.0
1440
120
74.4
26.0
1560
170
80.6
26.0
1560
200
80.6
20 °C temperature rise
20.0
1200
75
124.0
24.0
1440
120
148.8
26.0
1560
170
161.2
26.0
1560
200
161.2
30 °C temperature rise
13.3
800
60
125.0
16.7
1000
87
160.0
20.0
1200
100
188.0
21.7
1300
200
199.0
40 °C temperature rise
10.0
600
35
125.0
12.5
750
50
160.0
15.0
900
55
188.0
16.3
975
95
199.0
50 °C temperature rise
8.0
480
24
125.0
10.0
600
35
160.0
12.0
720
40
188.0
13.0
780
70
199.0
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 41
Rinnai INFINITY HD
Temperature preset to 55 °C or less (mixed water)
HD
model
Approx. min.
to max. gas
input (MJ/h)
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
5 °C temperature rise
10 °C temperature rise
L/min
L/h
Pressure
Approx. gas L/min
L/h
Pressure
Approx. gas
loss
consumption
loss
consumption
through
(MJ/h)
through
(MJ/h)
unit (kPa)
unit (kPa)
32
1920
200
47.8
32
1920
200
95.7
32
1920
200
47.8
32
1920
200
95.7
37
2220
200
55.3
37
2220
200
110.6
15 °C temperature rise
20 °C temperature rise
32
1920
200
143.5
32
1920
200
199.0
32
1920
200
143.5
32
1920
200
195.0
37
2220
200
165.9
37
2220
200
226.6
25 °C temperature rise
30 °C temperature rise
26
1560
200
199.0
21.7
1302
112.5
199.0
26
1560
200
195.0
21.7
1302
112.5
195.0
32
1920
140
250.0
26.7
1602
100
250.0
35 °C temperature rise
40 °C temperature rise
18.6
1116
75
199.0
16.3
978
60
199.0
18.6
1116
75
195.0
16.3
978
60
195.0
22.9
1374
60
250.0
20
1200
50
250.0
45 °C temperature rise
50 °C temperature rise
14.4
864
45
199.0
13
780
40
195.0
14.4
864
45
195.0
13
780
40
195.0
17.8
1068
40
250.0
16
960
40
250.0
42 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY HD
Temperature preset to 75 °C (unmixed water)
HD
model
Approx. min.
to max. gas
input (MJ/h)
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
HD200 16-199
HDi200 16-195
HD250 20-250
5 °C temperature rise
10 °C temperature rise
L/min
L/h
Pressure
Approx. gas L/min
L/h
Pressure
Approx. gas
loss
consumption
loss
consumption
through
(MJ/h)
through
(MJ/h)
unit (kPa)
unit (kPa)
24
1440
200
34.8
24
1440
200
72.9
24
1440
200
34.8
24
1440
200
72.9
24
1440
200
36.4
24
1440
200
72.9
15 °C temperature rise
20 °C temperature rise
24
1440
200
104.3
24
1440
200
139.0
24
1440
200
104.3
24
1440
200
139.0
24
1440
200
109.3
24
1440
200
145.7
25 °C temperature rise
30 °C temperature rise
24
1440
200
173.8
21.7
1302
112.5
199.0
24
1440
200
173.8
21.7
1302
112.5
195.0
24
1440
200
182.2
24
1440
140
250.0
35 °C temperature rise
40 °C temperature rise
18.6
1114
75
199.0
16.3
975
60
199.0
18.6
1114
75
195.0
16.3
975
60
195.0
22.9
1371
130
250.0
20.0
1200
100
250.0
45 °C temperature rise
50 °C temperature rise
14.4
867
45
199.0
13.0
780
40
199.0
14.4
867
45
195.0
13.0
780
40
195.0
17.8
1067
80
250.0
16.0
960
70
250.0
55 °C temperature rise
60 °C temperature rise
11.8
709
36
199.0
10.8
650
33
199.0
11.8
709
36
195.0
10.8
650
33
195.0
14.5
873
50
250.0
13.3
800
45
250.0
65 °C temperature rise
70 °C temperature rise
10.0
600
31
199.0
9.3
557
29
199.0
10.0
600
31
195.0
9.3
557
29
195.0
12.3
738
40
250.0
11.4
686
35
250.0
75 °C temperature rise
80 °C temperature rise
8.7
520
29
199.0
8.1
488
29
199.0
8.7
520
29
195.0
8.1
488
29
195.0
10.7
640
30
250.0
10.0
600
25
250.0
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 43
Rinnai INFINITY EF
Temperature preset to 55 °C or less (mixed water)
EF
model
Approx. min.
to max. gas
input (MJ/h)
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
5 °C temperature rise
10 °C temperature rise
L/min
L/h
Pressure
Approx. gas L/min
L/h
Pressure
Approx. gas
loss
consumption
loss
consumption
through
(MJ/h)
through
(MJ/h)
unit (kPa)
unit (kPa)
30.0
1800
240.0
41.9
30.0
1800
240.0
79.3
37.0
2220
340.0
51.6
37.0
2220
340.0
97.8
37.0
2220
340.0
51.6
37.0
2220
340.0
97.8
15 °C temperature rise
20 °C temperature rise
30.0
1800
240.0
118.9
30.0
1800
240.0
162.0
37.0
2220
340.0
146.7
37.0
2220
340.0
195.6
37.0
2220
340.0
146.7
37.0
2220
340.0
195.6
25 °C temperature rise
30 °C temperature rise
24.0
1440
140.0
162.0
20.0
1200
80.0
162.0
32.0
1920
240.0
211.0
26.7
1600
171.0
211.0
32.0
1920
240.0
211.0
26.7
1600
171.0
211.0
35 °C temperature rise
40 °C temperature rise
17.1
1028.6
60.0
162.0
15.0
900
50.0
162.0
22.9
1371.4
130.0
211.0
20.0
1200
96.0
211.0
22.9
1371.4
130.0
211.0
20.0
1200
96.0
211.0
45 °C temperature rise
50 °C temperature rise
13.3
800.0
45.0
162.0
12.0
720
31.0
162.0
17.8
1066.7
82.0
211.0
16.0
960
61.9
211.0
17.8
1066.7
82.0
211.0
16.0
960
61.9
211.0
44 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Rinnai INFINITY EF
Temperature preset to 75 °C (unmixed water)
EF
model
Approx. min.
to max. gas
input (MJ/h)
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
EF24
EF250
EFi250
16-162
10-211
10-211
5 °C temperature rise
10 °C temperature rise
L/min
L/h
Pressure
Approx. gas L/min
L/h
Pressure
Approx. gas
loss
consumption
loss
consumption
through
(MJ/h)
through
(MJ/h)
unit (kPa)
unit (kPa)
24
1440
140
33.5
24
1440
140
63.4
24
1440
137
33.5
24
1440
137
63.4
24
1440
137
33.5
24
1440
137
63.4
15 °C temperature rise
20 °C temperature rise
24.0
1440
140
95.2
24.0
1440
140.0
126.9
24.0
1440
137
95.2
24.0
1440
137.0
126.9
24.0
1440
137
95.2
24.0
1440
137.0
126.9
25 °C temperature rise
30 °C temperature rise
24.0
1440
140
162.0
20.0
1200
80.0
162.0
24.0
1440
137
158.6
24.0
1440
137.0
190.3
24.0
1440
137
158.6
24.0
1440
137.0
190.3
35 °C temperature rise
40 °C temperature rise
17.1
1029
60
162.0
15.0
900
50.0
162.0
22.9
1371
130
211.0
20.0
1200
96.0
211.0
22.9
1371
130
211.0
20.0
1200
96.0
211.0
45 °C temperature rise
50 °C temperature rise
13.3
800
45
162.0
12.0
720
31.0
162.0
17.8
1067
82
211.0
16.0
960
61.9
211.0
17.8
1067
82
211.0
16.0
960
61.9
211.0
55 °C temperature rise
60 °C temperature rise
10.9
655
29
162.0
10.0
600
27.0
162.0
14.5
873
48.1
211.0
13.3
800
41.2
211.0
14.5
873
48.1
211.0
13.3
800
41.2
211.0
65 °C temperature rise
70 °C temperature rise
9.2
554
26
162.0
8.6
514
25.0
162.0
12.3
738
34.3
211.0
11.4
686
27.5
211.0
12.3
738
34.3
211.0
11.4
686
27.5
211.0
75 °C temperature rise
80 °C temperature rise
8.0
480
25
162.0
7.5
450
25.0
162.0
10.7
640
24.7
211.0
10.0
600
20.6
211.0
10.7
640
24.7
211.0
10.0
600
20.6
211.0
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 45
Appendix 2
Rinnai INFINITY inbuilt frost protection
Frost protection is fitted as standard on all Rinnai INFINITY models. Frost
protection operates automatically, as required, whenever the appliance is
connected to the electric power supply.
How frost protection works
When the temperature inside the unit drops below 3.5 °C the frost protection turns on, providing
approximately 15 W of heat via electricity. Once the temperature inside the unit reaches 7 °C the
frost protection switches itself off.
The heat, provided by strategically placed ceramic heating elements, stops the water from
freezing within the pipework of the unit.
As frost protection requires electricity to run it is important that the unit is connected to the
power supply at all times. If left off in an area prone to frost Rinnai recommend draining the
appliance to prevent frost damage (not covered by warranty).
ceramic heating element
Long ceramic heating element inside a Rinnai INFINITY unit
46 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Appendix 3
Manifolding components what to use where
MECS
Master
Position
Internal*
Code
REUMSBM
OR External**
REUMSBMB
Slave
Joiner
REUMSBC1
REUMSBC2
Number of water heaters
*
**
2
1
1
-
-
3
1
1
1
-
4
1
1
2
-
5
1
1
3
-
6
2
2
2
1
7
2
2
3
1
8
2
2
4
1
9
2
2
5
1
10
2
2
6
1
11
3
3
5
2
12
3
3
6
2
13
3
3
7
2
14
3
3
8
2
15
3
3
9
2
16
4
4
8
3
17
4
4
9
3
18
4
4
10
3
19
4
4
11
3
20
4
4
12
3
21
5
5
11
4
22
5
5
12
4
23
5
5
13
4
24
5
5
14
4
25
5
5
15
4
Internal: Master PCB located inside the Rinnai INFINITY
External: Master PCB located outside the Rinnai INFINITY
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 47
Appendix 4
HD connection positions underneath unit (mm)
HD200 external
Front of unit
HD200 ext
4
1
3
2
1
Gas connection from wall
Gas connection from centre
103
89
2
Cold water inlet from wall
Cold water inlet from centre
74
27
3
Hot water outlet from wall
Hot water outlet from centre
95
110
4
Electrical connection from wall
Electrical connection from centre
160
21
Wall bracket
HDi200 internal
HDi200 ext
Front of unit (cover not on)
4
1
3
1
Gas connection from wall
Gas connection from centre
99~139
89
2
Cold water inlet from wall
Cold water inlet from centre
70~110
27
3
Hot water outlet from wall
Hot water outlet from centre
91~131
110
4
Electrical connection from wall
Electrical connection from centre
160~200
21
2
Wall bracket
Please note: Cover is not showing in image
HD250 external
HD250 ext
Front of unit
4
3
2
1
Gas connection from wall
Gas connection from centre
61
110
2
Cold water inlet from wall
Cold water inlet from centre
99
52
3
Hot water outlet from wall
Hot water outlet from centre
115
61
4
Electrical connection from wall
Electrical connection from centre
2
100
1
Wall bracket
48 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
Appendix 5
EF connection positions underneath unit (mm)
EF24 external
EF24 ext
Front of unit
4
3
2
1
5
Wall bracket
1
Gas connection from wall
Gas connection from centre
70.5
25
2
Cold water inlet from wall
Cold water inlet from centre
83
53
3
Hot water outlet from wall
Hot water outlet from centre
164.5
100
4
Electrical connection from wall
Electrical connection from centre
175
10
5
Condensate outlet from wall
Condensate outlet from centre
33
132
EFi250 internal
EFi250 int
Front of unit (cover not on)
4
5
3
2
1
Wall bracket
1
Gas connection from wall
Gas connection from centre
89~129
103.2
2
Cold water inlet from wall
Cold water inlet from centre
64.6~104
27.7
3
Hot water outlet from wall
Hot water outlet from centre
100~140
100
4
Electrical connection from wall
Electrical connection from centre
200~240
49
5
Condensate outlet from wall
Condensate outlet from centre
122.6
195
Please note: Cover is not showing in image
EF250 external
EF250 ext
Front of unit
4
5
3
2
1
Wall bracket
1
Gas connection from wall
Gas connection from centre
89
103.2
2
Cold water inlet from wall
Cold water inlet from centre
64.6
27.2
3
Hot water outlet from wall
Hot water outlet from centre
100
100
4
Electrical connection from wall
Electrical connection from centre
200
49
5
Condensate outlet from wall
Condensate outlet from centre
122.6
195
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 49
Appendix 6
LPG gas bottle consumption and cylinder clearances
LPG gas bottle consumption
Overview of LPG cylinder clearances
We often get asked about how long a gas bottle
will last when running a gas appliance. Using
the calculation below you can work this out
yourself.
LPG gas bottle energy calculation
1 kg of LPG gas contains 50.4 MJ of energy. This
means that a 45 kg LPG has bottle has 45 kg x
50.4 MJ = 2268 MJ. This calculation works for
different gas bottle sizes, here are the most
common:
• 9 kg
= 453.6 MJ
• 45 kg
= 2268 MJ
• twin pack = 4536 MJ (two 45 kg gas bottles)
B
A
C
D
Calculating how long an LPG bottle will last
To work out how many hours an LPG bottle will
last you need to divide the energy (MJ) of the
gas bottle by the total MJ input of the appliance.
A Min. clearance to a door
1m
B Min. clearance to an openable window
150 mm
For example
A household has a VT26 installed which runs
approximately 20 minutes a day, three five
minute showers and intermittent use of vanity
and kitchen taps (approx. five minutes).
D Min. clearance to a drain
• 2268 ÷ 199 MJ/h (maximum input of unit)
= 11.40 hours (running at full capacity)
• 11.40 hours x 60 minutes = 684 minutes
• 684 minutes ÷ 20 minutes (use per day)
= 34.2 days (approx. one 45 kg per month)
The above example is based on the unit
operating at a maximum flow rate and MJ/h
input (26 L/min and 199 MJ/h). In the real-world
this won’t be the case as the flow rate and gas
consumption when using vanity and kitchen
taps is much lower (2.4 L/min and 13 MJ/h), so in
reality the gas bottle will last a little longer.
Please note: This doesn’t factor other gas
appliances in the house.
For more information you can search the
internet (how long will a 45 kg gas bottle last)
as there are additional resources and blogs
available.
50 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15
C Min. clearance to an air vent or opening 1 m
1m
The above diagram is a modified version of a
drawing originally produced by ongas
(www.ongas.co.nz). It is intended to provide an
overview of the general clearances required for
LPG cylinders.
For detailed information relating to LPG cylinder
placement it is advisable to consult a licensed
gasfitter, your nearest LPG cylinder supplier, or
consult AS/NZS 5601.1 Gas Installations.
Appendix 7
Gas boosted solar
Rinnai INFINITY models can be easily plumbed to provide additional heat to a
solar hot water system to heat water when the solar hot water is not available.
How a gas boosted system works
1. The sun’s rays heat water in the solar
panels.
2. Hot water from the panels is stored
in the tank.
3. If the water is too cold, the Rinnai
INFINITY gas boost heats the water
on demand as it travels from the tank
to the tap.
1
3
2
The size of the Rinnai INFINITY depends
on the number of bathrooms, select
the Rinnai INFINITY model as if solar hot
water was not available.
Recommended system layout using a Rinnai INFINITY and flow diversion valve
Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 51
Experience our innovation
Rinnai.co.nz
0800 746 624
http://www.youtube.com/rinnainz
http://www.facebook.com/rinnainz