Specification guide Rinnai INFINITY® gas continuous flow water heating Important Rinnai is constantly improving its products, and as such, information and specifications are subject to change without notice. For the most up-to-date information go to www.rinnai.co.nz. This information is not intended as an installation guide. We’d love to hear from you If you have any feedback about this guide we’d love to hear from you. Either email us at [email protected] (place ‘Rinnai specification guide feedback’ in the subject heading), or call Customer Services. Help is here For more information about buying, using, and servicing of Rinnai appliances call: 0800 RINNAI (0800 746 624). Rinnai New Zealand Limited 105 Pavilion Drive, Mangere, Auckland PO Box 53177, Auckland Airport, Auckland 2150 Phone: (09) 257 3800 Email: [email protected] Web: www.rinnai.co.nz www.youtube.com/rinnainz www.facebook.com/rinnainz : s t n e t n co Leaders in continuous flow.....................................4 What is continuous flow?.........................................5 Continuous flow summary table.............................6 Model selection for residential applications...........7 Model selector........................................................8 Location of Rinnai INFINITY units............................9 General clearances..................................................10 Product specification pages Rinnai INFINITY VT..................................................12 Rinnai INFINITY HD.................................................14 Rinnai INFINITY EF...................................................16 Rinnai INFINITY accessories summary table...........18 Rinnai INFINITY internal flueing options.................20 Rinnai INFINITY flueing guidelines..........................21 Direct flueing using the FFSSKIT..............................22 Horizontal extension flueing...................................22 Vertical straight flueing...........................................23 Combination flueing...............................................23 Rinnai INFINITY flue components...........................24 Rinnai INFINITY accessories Rinnai INFINITY digital controllers..........................28 Rinnai INFINITY composite recess box....................30 Rinnai INFINITY metal recess box............................31 Rinnai INFINITY pipe covers....................................32 Rinnai INFINITY security bracket.............................33 Rinnai INFINITY sideways flue diverter....................34 Rinnai INFINITY upwards flue diverter.....................35 Rinnai INFINITY HD error switch.............................36 Rinnai INFINITY EZ connect cable...........................37 Rinnai INFINITY manifolding...................................38 Appendices Appendix 1 Water flow and gas usage........................................40 Appendix 2 Rinnai INFINITY inbuilt frost protection..................46 Appendix 3 Manifolding components what to use where..........47 Appendix 4 HD connection positions underneath unit.............48 Appendix 5 EF connection positions underneath unit...............49 Appendix 6 LPG gas bottle consumption and cylinder clearances... 50 Appendix 7 Gas boosted solar....................................................51 Leaders in continuous flow When you turn on a tap you want water at the right temperature fast, which is why over the years we’ve devoted considerable time and resource to leading edge research and development. We were the first to introduce continuous flow technology and have been tirelessly working on improving this ever since. Our commitment to bring you the latest technology has resulted in the next generation of water heaters. 1991 Rinnai INFINITY original microprocessor 1995 Rinnai INFINITY Q-function 2002 Rinnai INFINITY dynamic flow control 2004 Rinnai INFINITY V-Series rapid start 2006 Rinnai INFINITY XR 2008 Rinnai INFINITY EF 2011 Rinnai INFINITY VT 2013 Rinnai INFINITY VT series 2* The Rinnai INFINITY range is made up of the following three categories: Rinnai INFINITY VT (residential applications only) Valve technology that delivers performance and efficiency for daily living. Rinnai INFINITY EF (residential and commercial applications) High efficiency condensing technology to deliver further savings. Rinnai INFINITY HD (residential and commercial applications) Heavy duty on demand for demanding jobs. * Rinnai INFINITY Series 2: Improved software, which allow the units to run more efficiently—this has resulted in increased energy star ratings. 4 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 What is continuous flow? A continuous flow gas hot water system only heats water when it passes through the unit. It will deliver a continuous flow of heated water at a predetermined flow rate, depending on the model, as long as the unit is connected to the power supply. General principle of operation Each Rinnai INFINITY has a number of components that control the accuracy of water temperature and water flow. These components are: • • • • • PCB (the onboard computer) water control valve water flow sensor modulating gas valve outlet water temperature sensor The unit senses the need to start when water begins to flow through the appliance (when a tap is turned on). The combustion fan starts, ignition begins (electronic requiring electricity), and the gas valve opens. Once the flame is established the appliance will heat the water as required until the tap is turned off. How gas continuous flow works Standard VT/HD continuous flow unit Condensing EF continuous flow unit 5% Loss 95% Efficiency CH HC Condensing technology utilises a secondary latent heat exchanger to increase the thermal efficiency of the unit (95% vs. 80%). Incoming cold water passes through the latent heat exchanger first where heat is extracted from the exhaust gas (which would otherwise be wasted), which preheats the water by approximately 5 °C before going to the primary heat exchanger. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 5 Continuous flow summary table Rinnai INFINITY model Mounting Application suitability position Energy star rating Input Output Thermal efficiency on high Status monitor VT16 External Residential only 6.2 125 MJ/h or 35 kW 29.6 kW 81% No VT20 External Residential only 6.1 160 MJ/h or 44 kW 34.9 kW 80% No VT24 External Residential only 6.0 188 MJ/h or 52 kW 42.1 kW 80% No VT26 External Residential only 6.1 199 MJ/h or 55 kW 44.2 kW 80% No HD200 External Residential and commercial 5.9 199 MJ/h or 55 kW 47.0 kW 82% Yes HDi200 Internal Residential and commercial 6.1 195 MJ/h or 54 kW 45.1 kW 83% No HD250 External Residential and commercial 5.9 250 MJ/h or 69 kW 59.9 kW 81% No EF24 External Residential and commercial 6.8 162 MJ/h or 45 kW 43.0 kW 95% No EF250 External Residential and commercial 7.0 211 MJ/h or 58.6 kW 55.6 kW 95% Yes EFi250 Internal Residential and commercial 7.0 211 MJ/h or 58.6 kW 55.6 kW 95% Yes In tern al m o de ls Ex te rn a l m o d e l s Water delivery at a 25 °C rise 16 L 20 L High efficiency Standard efficiency 24 L 26 L EF24 VT16 VT20 VT24 EF250 VT26 HD200 High efficiency HD250 EFi250 HDi200 Standard efficiency Please note 32 L Service and maintenance For reliable operation Rinnai continuous flow water heaters in residential applications should be serviced every two years. For commercial applications Rinnai has a recommended commercial maintenance and servicing schedule. This is available on request or via www.rinnai.co.nz. 6 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Model selection for residential applications When specifying residential hot water applications there are some basic questions that you need to ask in order to correctly design a system. You also need to bear in mind the future requirements of the building. The key point is water heating solutions should be designed to the number of hot water outlets and not the number of people. Which model? Questions to ask to determine which model(s) may be suitable. the Rinnai INFINITY closer to the kitchen sink where there is an immediate demand for hot water. • How many bathrooms? If bathrooms are situated at opposite ends of the house two Rinnai INFINITY units may be required. • Where are the bathrooms and other hot water outlets positioned in the house? • How often will the hot water outlets run simultaneously? • What type of tapware is installed? • What is the location of the property in New Zealand? How many bathrooms? A VT16 or VT20 unit may be suitable for a one bathroom home, whereas a two or three bathroom home will need a larger Rinnai INFINITY, or even multiple units. Where are the bathrooms and other hot water outlets positioned in the house? Where are the bathrooms and other hot water outlets in relation to where the Rinnai INFINITY is to be installed? In most cases it is better to site How often will the hot water outlets run simultaneously? How likely will hot water outlets, such as showers, be used at the same time. Scenario one: Two bathroom home with a couple who rarely use the second shower—a VT20 may be suitable. Scenario two: Two bathroom home with a family of five who fight for two showers in the morning—a larger Rinnai INFINITY would be needed. What type of tapware is installed? There is a large range of tapware in the market, some with very high flow rates. The main consideration is the type of shower rose installed and how many litres it puts out—typical flow rates for showers is around 8-10 L/min. This needs to factored when determining the required Rinnai INFINITY model. To measure the flow rate of a shower, hold a bucket under the shower rose for one minute and measure the volume of water. Location of the property in New Zealand? Ambient water temperatures will vary throughout the country, for example, the South Island in winter will be much colder than the North Island. This is important when determining the incoming water temperature and the temperature rise required at the hot water outlet as this will affect the output of the unit. For more information refer appendix 1 on p. 40. Use the New Zealand map on the next page to determine the location of the property in relation to the climate zone. Budget, size of house, number of hot water outlets, and hot water requirements all factor in determining the right continuous flow hot water system for your home. Use the product selector table on the next page to work our which model is right for you. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 7 Model selector 1. Determine the hot water outlets that will run simultaneously in your house, and list the flow rates against them. Hot water outlet Typical flow rate* Bathroom 9 L per minute Worked example 9L Bathroom two 9 L per minute 9L Kitchen 6 L per minute 6L Laundry 6 L per minute** Other Allow 6 L per minute TOTAL 24 L * You can check your own actual water flow rates by holding a bucket under the hot water outlet for a minute and measuring the volume. ** A number of washing machines, particularly front loaders, have a cold-only connection as they have an internal heater. Hot water in this instance, as it isn’t required, would not need to be factored into the calculation. 2. Total the maximum simultaneous water flow, e.g. 24 litres. 3. In the column for geographical region move down until a number bigger than your total appears. Warm (L/min) Mild (L/min) Cool (L/min) VT model 16 13 11 16 HD model 200 EF model 24 20 17 14 20 200 24 24 20 17 24 200 24 26 22 19 26 200 250 30 26 22 26 250 250 32 27 23 250 250 4. Read across to the model, e.g. for 24 litres per minute in the mild zone a VT26 is selected. If you find the flow rate is greater than the figures listed in the table please contact Rinnai for advice. Multiple units may be required or an alternative hot water heating solution. *RADIUS Warm Mild Cool 8 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Location of Rinnai INFINITY units To provide safe and effective water heating it is important to adhere to all relevant gas installation standards. Check the guidelines detailed in this guide. If in any doubt it pays to consult a licensed gasfitter to double check where the unit can be located. General installation considerations The Rinnai INFINITY should be placed as close as possible to the most frequently used hot water outlet(s) to minimise the delay for hot water. In most cases it is better to site the Rinnai INFINITY closer to the kitchen where there is an immediate demand for hot water. For installations where the distance between the water heater and outlets is considerable, a flow and return system with a buffer tank, can be used to minimise the waiting time for hot water delivery. Alternatively multiple units can be strategically placed to serve different outlets. Operating noise Some people are susceptible to low level noise. Rinnai INFINITY units operate at 49 dB(A). This needs to be considered if locating the appliance near a bedroom. Easy access All continuous flow water heaters must be installed to ensure access can be gained for servicing and repair, without hazard or undue difficulty. If mounting appliances at height the owner must arrange permanent and safe access, or provide another means of access such as scissor or boom lifts. External models External models are designed for outdoor installations only. They must be located above ground where the products of combustion can be naturally dispersed. They should not be in enclosed areas as the unit can be choked by its own flue gases, which will cause the unit to malfunction. Refer to the general flue clearances diagram on the next page. Internal models Internal models are designed for indoor installations only. External models must be mounted on a vertical structure with the water and gas connections on the underside pointing downwards. They are a flued appliance— flue components purchased separately. They may be installed in an enclosure if the requirements of AS/NZS 5601.1 are satisfied. An enclosure is defined as a compartment, enclosed area or partitioned off space primarily used for the installation of the appliance. For internal units we recommend a 600 mm clearance for servicing access. This can be reduced to 50 mm if installed in a cupboard, refer to the general access clearances diagram on the next page. Internal models must be mounted on a vertical structure with the water and gas connections on the underside pointing downwards. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 9 General clearances The following diagrams have been provided to assist in determining where, and if a continuous flow water heater can be installed. If in doubt, consult a licensed gasfitter who will have access to the Gas Installation standards. External models: General flue clearances G Dim. Infinity VT, Infinity HD250 HD200, EF models models A Min. 300 mm Min. 500 mm B Min. 300 mm Min. 500 mm C Min. 1.5 m Min. 1.5 m D Min. 500 mm Min. 500 mm E Min. 300 mm Min. 300 mm F Min. 300 mm* Min. 300 mm* G Min. 300 mm Min. 300 mm Other clearances Below eaves, balconies, and other projections, minimum 300 mm. From a gas meter, minimum 1000 mm. From an electricity meter or fuse box, minimum 500 mm. * Rinnai recommend 1.5 m to give enough clearance for the pipe work, and to safely expel flue gases. Internal models: General access clearances 75 mm min. 75 mm min. 600 mm min. (50 mm min if in a cupboard) For internal units we recommend a 600 mm clearance for servicing access. This can be reduced to 50 mm if installed in a cupboard. Example of an HDi200 internal installed in a cupboard - Rinnai Auckland showroom. 10 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY Product specification pages Rinnai INFINITY VT specification summary Rinnai INFINITY VT external codes Gas Type VT16 VT20 NG INFVT16N INFVT20N VT24 INFVT24N VT26 INFVT26N LPG INFVT24L INFVT26L INFVT16L INFVT20L Description Continuous flow gas hot water heaters (with inbuilt frost protection), preset to 55 °C, for external residential applications. Suitable for mains and medium pressure systems. Electronic ignition— requires electricity to operate. Infinity VT (Valve Technology) uses a new manifold system, which at lower flow rates, precisely matches water supply to flow demand at the required temperature. Hard or acidic water will need to be treated to use this product. VT20 VT24 VT26 REU No. VR1620WG VR2024WG VR2426WG VR2626WG Colour White White White White Hot R½ (15 mm) R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Cold R½ (15 mm) R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Gas R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Efficiency 81% 80% 80% 80% Energy star rating 6.2 star energy equivalent 6.1 star energy equivalent 6.0 star energy equivalent 6.1 star energy equivalent Hot water capacity 1.5-16 L/min 1.8-20 L/min 1.8-24 L/min 1.8-26 L/min Nominal water capacity* 16 L/min 960 L/h 20 L/min 1200 L/h 24 L/min 1440 L/h 26 L/min 1560 L/h Input on max. 125 MJ/h 160 MJ/h 188 MJ/h 199 MJ/h Output on max. 29.6 kW 34.9 kW 42.1 kW 44.2 kW Water supply 120-1000 kPa 160-1000 kPa 180-1000 kPa 130-1000 kPa Weight 15 kg 16 kg 17 kg 17 kg Connections VT16 * Nominal water capacity at a 25 °C rise 12 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY VT dimensions (mm) 350 194 270 530 571 H I A C E B D F G All VT models A Hot water outlet from wall 87 B Hot water outlet from centre 105 C Cold water inlet from wall 68 D Cold water inlet from centre 10 E Gas connection from wall 77 F Gas connection from centre 83 G Gas: Length gas connection from base 40 Cold: Length of cold water inlet from base 50 Hot: Length of hot water outlet from base 39 H Electrical connection from centre 45 I Electrical connection from wall 128 Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 13 Rinnai INFINITY HD specification summary Rinnai Infinity HD codes Gas Type HD200 external NG INFHD200HNCN HDi200 internal HD250 external INFHD200FFNCFN INFHD250HNCN LPG INFHD200FFNCFL INFHD250HNCL INFHD200HNCL Description Continuous flow gas hot water heaters (with inbuilt frost protection) for residential and commercial applications. Suitable for mains and medium pressure systems. Electronic ignition— requires electricity to operate. The internal unit is a room sealed appliance. The HDi200 and HD250 are preset to 55 °C, the HD200 is preset to 75 °C. All HD units can be preset to deliver higher hot water temperatures making them ideal for commercial applications. Hard or acidic water will need to be treated to use this product. HDi200 internal HD250 external REU No. VRM2632WC VR2632FFUG VR3237WG Colour Silver Silver Silver Hot R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Cold R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Gas R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Efficiency 82% 83% 81% Energy star rating 5.9 star equivalent 6.1 star equivalent 5.9 star equivalent Hot water capacity 2.4-30 L/min 2.4-32 L/min 2.4-37 L/min Nominal water capacity* 26 L/min 1560 L/h 26 L/min 1560 L/h 32 L/min 1920 L/h Input on max. 199 MJ/h 195 MJ/h 250 MJ/h Output on max. 47 kW 45.1 kW 59.9 kW Water supply 130-1000 kPa 140-1000 kPa 200-1000 kPa Weight 21 kg 21 kg 29 kg Connections HD200 external * Nominal water capacity at a 25 °C rise 14 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY HD dimensions (mm) A B O K N L E C D G I F M H J N.B: This is a generic connections drawing to highlight what dimensions are displayed in the below table. For reference to the actual position of each connection for each model refer images in appendix 4 on p. 48. HD200 ext. VRM2632WC HDi200 int. VR2632FFUG HD250 ext. VR3237WG A Width 350 350 470 B Depth 250 235~275 244 C Height - unit 600 600 600 D Height - including brackets 636 641 644 E Hot water outlet from wall 95 91~131 115 F Hot water outlet from centre 110 110 61 G Cold water inlet from wall 74 70~110 99 H Cold water inlet from centre I Gas connection from wall 103 99~139 61 J Gas connection from centre 89 89 110 K Electrical connection from centre 21 (right of centreline) 21 (right of centreline) 2 (right of centreline) L Electrical connection from wall 160 160~200 100 41 41 41 Cold: Length of cold water inlet from base 51 51 51 Hot: Length of hot water outlet from base 42 42 42 M Gas: Length gas connection from base 27 (left of centreline) 27 (left of centreline) 52 N Flue spigot centreline (from wall) N/A 95~135 N/A O Height of flue spigot from base of unit N/A 85 N/A Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 15 Rinnai INFINITY EF specification summary Rinnai Infinity EF codes Gas Type EF24 external NG EFF24NCN EFi250 internal INFEF250FFN EF250 external INFEF250N LPG INFEF250FFL INFEF250L EFF24NCL Description High efficiency continuous flow gas hot water heaters (with inbuilt frost protection), preset to 55 °C, for residential and commercial applications. Suitable for mains and medium pressure systems. Electronic ignition—requires electricity to operate. The internal unit is a room sealed appliance. EF250/EFi250 units can be preset to deliver higher hot water temperatures making them ideal for commercial applications. Hard or acidic water will need to be treated to use this product. EFi250 internal EF250 external REU No. K2430WG KM3237FFUD KM3237WD Colour White Gunmetal Grey Gunmetal Grey Hot R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Cold R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Gas R¾ (20 mm) R¾ (20 mm) R¾ (20 mm) Condensate R½ (15 mm) R½ (15 mm) R½ (15 mm) Connections EF24 external Efficiency 95% 95% 95% Energy star rating 6.8 star energy equivalent 7.0 star energy equivalent 7.0 star energy equivalent Hot water capacity 2.3-30 L/min 1.5-37 L/min 1.5-37 L/min Nominal water capacity* 24 L/min (1440 L/h) 32 L/min (1920 L/h) 32 L/min (1920 L/h) Input on max. 162 MJ/h 211 MJ/h 211 MJ/h Output on max. 43 kW 55.6 kW 55.6 kW Water supply 240-1000 kPa 240-1000 kPa 240-1000 kPa Weight 27 kg 32 kg 32 kg * Nominal water capacity at a 25 °C rise 16 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY EF dimensions (mm) A B P N O K C D E G F I H J L M N.B: This is a generic connections drawing to highlight what dimensions are displayed in the below table. For reference to the actual position of each connection for each model refer images in appendix 5 on p. 49. EF24 external K2430WG EFi250 internal KM3237FFUD EF250 external KM3237WD A Width 350 470 470 B Depth 277 257~307 283.1 C Height - unit 600 654 654 D Height - including brackets 644 721.6 721.6 E Hot water outlet from wall 164.5 100~140 100 F Hot water outlet from centre 100 100 100 G Cold water inlet from wall 83 64.6~104 64.6 H Cold water inlet from centre 53 (left of centreline) 27.7 27.2 I Gas connection from wall 70.5 89~129 89 J Gas connection from centre 25 103.2 103.2 K Condensate outlet from wall 33 122.6 122.6 L Condensate outlet from centre 132 195 195 M Gas: Length gas connection from base 51 40.2 40.2 Cold: Length of cold water inlet from base 62 50.2 50.2 Hot: Length of hot water outlet from base 41 41.2 41.2 Condensate connection length from base 24 22.4 22.4 10 (right of centreline) 49 49 N Electrical connection from centre O Electrical connection from wall 175 200~240 200 P Flue spigot centre line from wall N/A 155~195 N/A Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 17 Rinnai INFINITY accessories summary table Compact controller Kitchen Deluxe controller Bathroom Deluxe controller Wireless controller & transceiver Composite recess box Metal recess box Water Heater On/Off Temp. Volume Max Temp. Maintenance Entry RINNAI Controllers MC No. 1 No. 2 No. 3 p. 28 p. 28 p. 28 p. 28 p. 30 p. 31 VT16 MC912A MC100V1Z BC100V1Z MC503S & MC503M R1406 R1405 VT20 MC912A MC100V1Z BC100V1Z MC503S & MC503M R1406 R1405 VT24 MC912A MC100V1Z BC100V1Z MC503S & MC503M R1406 R1405 VT26 MC912A MC100V1Z BC100V1Z MC503S & MC503M R1406 R1405 HD200 MC912A MC100V1Z BC100V1Z MC503S & MC503M X R1407 HDi200 MC912A MC100V1Z BC100V1Z MC503S & MC503M X X HD250 MC912A MC100V1Z BC100V1Z MC503S & MC503M X R1407 EF24 MC912A MC100V1Z BC100V1Z MC503S & MC503M X R1407 EFi250 MC912A MC100V1Z BC100V1Z MC503S & MC503M X X EF250 MC912A MC100V1Z BC100V1Z MC503S & MC503M X X VT range HD range EF range 18 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Pipe cover Security bracket Sideways Upwards flue flue diverter diverter HD error indication switch EZ connect p. 32 p. 33 p. 34 p. 35 p. 36 p. 37 VT16 R1385 ACC1395 FDS16 FDU16 X X VT20 R1385 ACC1395 FDS20 FDU20 X X VT24 R1385 ACC1395 FDS24 FDU24 X X VT26 R1385 ACC1395 FDS24 FDU24 X X HD200 R1408SC ACC1395 X X R1070 REUEZC HDi200 R1408SC ACC1395 X X R1070 REUEZC HD250 R1402SC ACC1395 X FDU32 R1070 REUEZC EF24 R1408 ACC1395 X X X X EFi250 R1409 ACC1395 X X R1070 REUEZC EF250 R1409 ACC1395 X X R1070 REUEZC VT range HD range EF range Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 19 Rinnai INFINITY internal flueing options The flueing for internal water heaters is a coaxial design. It has a stainless steel inner pipe to discharge products of combustion and a thermoplastic outer pipe for air supply to the appliance. Each Rinnai INFINITY water heater is flued individually, refer flueing options diagram below. 3 1 2 4 Direct flueing: For direct flue installations through an external wall using the direct flue kit FFSSKIT—maximum wall thickness 430 mm (EFi250) and 485 mm (HDi200). Horizontal extension flueing: For flue installations through an external wall using the direct flue kit FFSSKIT and additional lengths of pipe. Vertical straight flueing: Installations where the internal unit is flued vertically through the roof. Combination flueing: Installations using a combination of horizontal and vertical flueing. 20 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY flueing guidelines Flue gases can reach temperatures up to 200 °C. The flue terminal is to terminate in a location so as not to cause a nuisance, in accordance with AS/NZS 5601. Flue support Ensure the flue is supported independently of the appliance by use of suitable clips or brackets, in accordance with AS/NZS 5601. Appropriate standoff brackets are supplied with each FFSSROOFCOWL and FFSSPIPE1000. Multiple flues Ensure minimum distances, as shown below are maintained. FFSSROOFCOWL A Min. clearance 500 mm Flue length The chart below highlights the maximum flue length and number of bends. Number of 90 ° Bends 0 1 2 3 A 4 1 2 A: A: Flue Length (m) 3 4 HDi200 EFi250 350 mm 470 mm 5 6 7 A 9 11 13 15 Max. flue length FFSSKIT A Each terminal is to be terminated at the same vertical height, refer images below—please note these images show our older style terminals, which have since been updated. Vertical terminations. To ensure products of combustion are cleared, adequate clearance from the building is required. The flue cowl should have a 500 mm clearance from any part of the building. This also applies to steeped and pitched roofs, which should be clear of the ridge line. Lesser clearances may provide perfectly adequate flue systems depending on the installation. Minimum clearances are shown in AS/NZS 5601. Older style roof cowls all terminating at the same height Older style horizontal terminals all terminating at the same height Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 21 Direct flueing using the FFSSKIT For installations where the Rinnai INFINITY is mounted directly on the inside of an external wall with a maximum wall thickness of 430 mm (EFi250) and 485 mm (HDi200). 430 mm max. EFi250 485 mm max. HDi200 430 mm max. EFi250 485 mm max. HDi200 140 mm hole 140 mm hole 2 ˚ fall FFSSKIT contains - 90 ° bend - horiz. flue terminal - int. rubber white wall trim - ext. rubber black wall trim 2 ˚ fall Approx. 150 mm 45 mm min. Horizontal flues MUST SLOPE 20 mm per metre to the termination point. Ensure condensate drains appropriately. 580 mm max. 580 mm max. Horizontal extension flueing For installations where the Rinnai INFINITY gas hot water heater is mounted against an internal wall and the flueing needs to be extended for a longer distance horizontally to exit an external wall. Condensate direction 2 ˚ fall to terminal Condensate direction (2 ˚ fall to appliance) FFSSCOND (HDi200 only) To sanitary waste 22 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Use FFSSKIT as a starting point and customise with flue pipe (FFSSPIPE1000). More than one flue pipe (can be cut to size) may be required. Total flue length can be up to 13 m. Condensate can be handled in two ways: 1. 2° fall to the termination point (20 mm per metre), ensure condensate drips will not cause damage. 2. Condensate drains back to the unit— HDi200 unit will need a condensate trap kit (FFSSCOND). Vertical straight flueing For installations where the Rinnai INFINITY needs to be flued vertically through the roof. FFSSROOFCOWL (with roof protectors fitted) For HDi200 units, a condensate trap (FFSSCOND) is required for flue lengths over 1.5 m. Total flue length can be 15 m. FFSSPIPE1000 Additional lengths can be added as required (can be cut to size) FFSSCOND (HDi200 only) To sanitary waste Combination flueing Combination of vertical and horizontal flueing. HDi200 unit will need a condensate trap kit (FFSSCOND). If starting horizontally and finishing horizontally, use FFSSKIT as a starting point and customise. FFSSROOFCOWL (with roof protectors fitted) If starting horizontally and ending vertically or vice versa, individual flue components will need to be ordered. Flueing must start with a FFSSBEND90 or FFSSPIPE1000 (can be cut to size). FFSSPIPE1000 e) Condensate direction (2 ˚ fall to applianc FFSSCOND (HDi200 only) To sanitary waste Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 23 Rinnai INFINITY flue components All the major flue components are constructed of a PVC outer and a stainless steel inner. These have zero clearance from combustibles. All dimensions are in mm. 90 degree bend (FFSSBEND90) 130 5 10 85 114 66 64.5 80 45 degree bend (FFSSBEND45) - sold as a pair 85 5 92 5 165 80 85 166 176 66 64.5 10 10 80 (As a 90° OFFSET) (As a 45° OFFSET) Flue pipe (FFSSPIPE1000) - can be cut to size, includes a Munzing ring to support the flue 10 85 PU 80 125 5 980 Condensate trap kit (FFSSCOND) for the HDi200 End-to-end approx. 180 mm Hose is approx. 516 mm I.D = 20 mm The FFSSCOND is not needed for the EFi250 as there is a different method to drain condensate (that doesn’t require additional flue components). For further information refer to the Rinnai INFINITY installation manual. 24 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Roof cowl for vertical installations (FFSSROOFCOWL) - can be cut to size Includes two black injection UV roof protectors, shown below for covering and protecting the white flue pipe from UV damage. Also includes a flue pipe clamp to support the flue. Black powder coat cast aluminium 483 953 Black PVC plastic 10 White PVC plastic Roof protector dimensions Length approx. 197 mm Joined length approx. 347 mm Diameter 140 mm 80 125 Direct flue kit for horizontal installations (FFSSKIT) - can be cut to size 565 13 30 30 5 10 85 114 225 125 80 130 66 64.5 150 80 Black and white wall trims that come with the kit 225 125 Thickness 1 mm Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 25 This page intentionally left blank Rinnai INFINITY Accessories Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 27 Rinnai INFINITY digital controllers With a Rinnai INFINITY digital controller you choose your own personalised settings. Just select the water temperature you want (37-55 °C) in up to four different locations. This means you can set water at a safe temperature in the bathroom (a great safety feature), then set it higher, if you wish, in the kitchen and laundry. Additional benefits • Reduces temperature fluctuation when other taps are used in the house. • Receive an extended warranty, Rinnai INFINITY units installed with digital controllers receive an extra two years warranty. • View and troubleshoot any problems by using the controller as a diagnostic tool, for example error code 11 when there is no gas. Location Water controllers are water resistant, however, durability is improved when positioned outside the shower recess. In other areas they must be installed at least 400 mm above the highest part of the sink, basin, or bath. Maximum number of controllers For residential applications a maximum of four controllers can be fitted, please note important points regarding controller combinations below. • Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller. • Up to TWO Bathroom Deluxe Controllers can be installed. • The fourth controller in any installation must be a Compact or Wireless Controller. Each controller can be individually programmed, however the water heater can only deliver one set temperature at any time. For example, John is in the shower and has set the controller to 42 °C, Jane uses the kitchen tap at the same time—the water temperature coming out of the kitchen tap will also be 42 °C (or lower if using a mixer and adding cold water). Jane can only change the programmed temperature once John is out of the shower. Wired controller cables All wired controllers come with 15 m of cable. Additional cable can be ordered: • R1069 • R1369 Please note Additional cable for the Compact and Bathroom Deluxe controllers Additional cable for the Kitchen Deluxe controller Rinnai controllers cannot be used with Rinnai INFINITY units connected to a solar system, or when a Rinnai iHeat is installed as the preset dip switch setting on the Rinnai INFINITY needs to be adjusted from 55 °C to 75 °C. 28 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Compact Controller • Smallest, most economical model • Off white with a grey touch pad • For use anywhere in the house • Dimensions: H-120 mm, W-90 mm, D-20 mm Code: MC912A Bathroom Deluxe Controller • Bathfill set-and-forget function • Silver • For use in bathrooms only • Dimensions: H-97 mm, W-195 mm, D-22 mm Code: BC100V1Z Bathfill function lets you set the desired water level and temperature and walk away. Also ideal as a water saver as the temperature and volume of water to be used in the shower can be set—great if you have teenagers. A voice message will let you know when your bath is ready. If you have other deluxe controllers around the house, the message will play on all of them. Please note: Bathfill function unable to be used if manifolding Rinnai INFINITY units together. Kitchen Deluxe Controller • Works in conjunction with the Bathroom Deluxe controller • Silver • For use in kitchens and laundries • Dimensions: H-120mm, W-128 mm, D-20 mm Code: MC100V1Z Wireless Controller • Wire free installation (battery operation) • Silver (controller) and white (transceiver) • For use anywhere in the house • Controller dimensions: H-142mm, W-66.6 mm, D-28 mm Codes MC503S (controller) MC503M (transceiver) No need to run wires in the wall or ceiling cavity—can be easily installed into existing houses, making it ideal for renovation projects. Can be used up to 50 m away from the water heater (maximum distance between the transceiver and Rinnai INFINITY is 20 m). Can be combined with a wired controller system. If ordering a wireless controller, you will need to order the controller and the transceiver—up to four controllers can be connected. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 29 Rinnai INFINITY composite recess box Description The Rinnai composite recess box is an affordable alternative to the metal recess box for housing the Rinnai INFINITY unit, pipe work, and power supply. The composite recess box enables a Rinnai external continuous flow water heater to be partially recessed into an external wall, covered and out of sight. Colour: Beige—can be painted to match the exterior cladding. Positioning A Rinnai INFINITY unit inside a recess box operates at a slightly louder level than a Rinnai INFINITY installed on an outside wall. Please bear this in mind when positioning near a bedroom as the operating noise could affect some people. Suitability • Outdoor installations only. • Installation with VT16-VT26 external units. Code: R1406 • New construction or major renovation—installation needs to commence during the framing stage before internal linings, claddings, or building wrap is applied. • Installation where the minimum framing depth is 88 mm. The composite recess box is not suitable for fire rated walls. Building code compliance Territorial authorities may have their own additional requirements regarding this type of installation as it is similar in detail to installing windows. If in doubt over compliance with building codes, it is advisable they are consulted prior to installation. 1086 1023 1078 118 69 Dimensions 440 12 Approximate depth with cover on - 240 mm 30 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 446 Rinnai INFINITY metal recess box Description The Rinnai metal recess box enables an external Rinnai INFINITY unit to be recessed, either fully or semi-recessed into an external wall, behind a door and out of sight. Construction is folded galvanised steel, powder coated white. Colour: White—can be painted to match the exterior cladding. Positioning A Rinnai INFINITY unit inside a recess box operates at a slightly louder level than a Rinnai INFINITY installed on an outside wall. Please bear this in mind when positioning near a bedroom as the operating noise could affect some people. Suitability • Outdoor installations only. • Installation with the following external Rinnai INFINITY units: - VT16-VT26 (use R1405) - HD200, HD250, EF24 (use R1407) Building code compliance Territorial authorities may have their own additional requirements regarding this type of installation as it is similar in detail to installing windows. If in doubt over compliance with building codes, it is advisable they are consulted prior to installation. Dimensions R1405 • Height 944 mm • Width 417 mm • Depth 205 mm R1407 944 mm 514 mm 270 mm Height Codes R1405VT16-VT26 R1407 HD200, HD250, EF24 • New construction or major renovation—installation needs to commence during the framing stage before internal linings, claddings, or building wrap is applied. Width h Dept Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 31 Rinnai INFINITY pipe covers Description If you want a clean smooth finish to the installation, the Rinnai INFINITY pipe cover can be used to cover pipes, valves, and even the external power point1. There are five pipe cover kits that vary in size and colour according to the type of Rinnai INFINITY being installed. 1 If the power point is located inside the cover it must comply with AS/NZS Wiring rules. Colour White:VT models and EF24 Silver: HD and EF250 models Dimensions (mm) W Codes R1385 VT16-VT26 R1402SCHD250 R1408 EF24 R1408SCHD200/HDi200 R1409 EF250/EFi250 H1 H2 D Pipe cover R1385 H1 394 H2 438 D 167 W 334 R1402SC 394 438 230 453 R1408 394 448 230 334 R1408SC 394 448 230 334 R1409 450 470 240 460 32 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY security bracket Description A sturdy security bracket can be installed to act as a deterrent to thieves. Consisting of two U-shaped 2 mm powder coated galvanised steel plates, which interlock through the lower bracket of the Rinnai INFINITY. The bracket is secured with a padlock (not included). How it works The bracket prevents access to the bolts fixing the unit to the wall, this locks the lower Rinnai INFINITY continuous flow water heater in place, and prevents the unit from being quickly removed from the wall. Code: ACC1395 Colour: Off-white—can be painted. Suitability For all Rinnai INFINITY continuous flow gas water heaters—can be retrofitted to existing installations. Can be installed on all cladding systems like weatherboard, brick, and plaster. Can also be installed inside a recess box. Ideal for Builders installing gas units on new homes that need to protect the Rinnai INFINITY before the home is sold or handed over to the new owners. Dimensions: • Height 70 mm • Width 190 mm • Depth 33.5 mm Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 33 Rinnai INFINITY sideways flue diverter Description The Rinnai INFINITY sideways flue diverter is an accessory that can be fitted to an external Rinnai INFINITY water heater. It is designed to expel combustion products in a sideways direction. The flue diverter is fitted with screws to the flue terminal of the water heater. Construction: Stainless steel Specific applications Noise reduction, in particular with the larger Rinnai INFINITY models, where the unit is positioned close to a neighbouring property. Codes FDS16 for VT16 FDS20 for VT20 FDS24 for VT24 and VT26 Where there may be an obstruction such as a tree, fence, wall, or other structure, that even though the Rinnai INFINITY is installed with the required clearances, will perform more efficiently if the flue gases are cleared away from the obstruction. Where clearance to an openable window or other building structure is tight, the clearance shifts to the point of discharge (close to the edge of the water heater case). j m 385 mm 140 m Openable window 75 mm Approximate depth when mounted on the unit 75 mm 50 mm Sideways flue diverter—ensure 1500 mm clearance n j and n relate to minimum clearancs required for balanced flue terminals from AS/NZS 5601.1 Suitability • Externally mounted Rinnai INFINITY continuous flow water heaters NOT installed in a recess box. • External SINGLE water heater applications only (can be installed for left and right handed installations). • Balconies, patios or other enclosed areas where products of combustion can be rapidly dispersed into the open-air. Important The flue diverter MUST remain as a permanent fixture as removal could mean the water heater position no longer complies with AS/NZS 5601.1. 34 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY upwards flue diverter Description The Rinnai INFINITY upwards flue diverter is an accessory that can be fitted to an external Rinnai INFINITY water heater. It is designed to expel combustion products in an upwards direction. The flue diverter is fitted with screws to the flue terminal of the water heater. Construction: Stainless steel Specific applications Noise reduction, in particular with the larger Rinnai INFINITY models, where the unit is positioned close to a neighbouring property. Where there may be an obstruction such as a tree, fence, wall, or other structure, that even though the Rinnai INFINITY is installed with the required clearances, will perform more efficiently if the flue gases are expelled upwards and away from the obstruction. Where there are multiple units installed that are positioned facing each other—there is the potential for the units to suffocate from the flue gases of the unit directly opposite. With an upwards flue diverter the flue gases can be expelled upwards and away from the units. Suitability • Externally mounted Rinnai INFINITY continuous flow water heaters NOT installed in a recess box. • Balconies, patios or other enclosed areas where products of combustion can be rapidly dispersed into the open-air. Important The flue diverter MUST remain as a permanent fixture as removal could mean the water heater position no longer complies with AS/NZS 5601.1. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 35 Rinnai INFINITY HD error switch Description The Rinnai INFINITY HD water heater error indication switch is a volt-free, normally open switch. The switch will shift to a closed position when there is an active error in the water heater. The switch is intended to be connected to a monitoring system such as a building management system, or other visual or audible error indication system. Suitability Suitable for commercial applications, and can be used with the following water heaters: Code:R1070 • • • • HD200 external HDi200 internal EFi250 internal EF250 external System design System designers should note that some errors will reset to an inactive (open) state under particular conditions. It is important that this is clearly understood when developing monitoring and response systems. Switch rating The HD error indication switch will switch the following maximum loads: • Voltage (AC or DC) 24 Volts • Current1 Amp Systems requiring loads greater than this should be configured via an external relay. 36 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY EZ connect cable Description The installation of a Rinnai EZ connect cable allows a maximum of two Rinnai INFINITY water heaters (specific models only) to be connected together so they function as one large unit. The two water heaters can be installed 5-460 mm apart. The maximum distance (460 mm) is so the cable will reach between the two units, and to prevent temperature fluctuations when the water is turned on and off. Code:REUEZC Installation Installation by a certified tradesperson is required. Suitability Can be used with the following water heaters: • HD200 external • HDi200 external • HD250 external • EFi250 external • EF250 external Please note: The bathfill function on the Bathroom Deluxe controller will not work if an EZ connect cable has been fitted. Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 37 Rinnai INFINITY manifolding Description Rinnai INFINITY units can be manifolded together, in banks of five (up to 25 individual units), by connecting them together in parallel to enable a greater hot water flow rate than is possible with a single unit. A manifold electronic control system links each Rinnai INFINITY unit in the system and will turn on each unit as required. The system is designed to ensure gas is not wasted and that an endless supply of hot water is always available. Codes REUMSB REUMSBMB REUMSBC1 REUMSBC2 (int. master) (ext. master) (slave) ( joiner ) Suitability • VT24 and VT26 models (in residential applications) • All HD models • All EF models Please note: • Rinnai do not specify manifolded systems for smaller VT units • For commercial applications use HD or EF250 models How it works A master (located internally or externally) and subcommunication PCB is installed in the first unit, other units only have the sub-communication PCB (slave cable) installed. The master communication PCB receives information about flow rates from the PCB of each unit and balances the load on each unit. Random selection of the units required to supply the flow demand means that all units share the workload evenly. All information is transmitted via communication cables to the slave units. The master control also has an inbuilt fault detection system and will allocate a replacement unit should one fail. Manifold components • REUMSB Internal (connection made inside the unit) master manifold kit. • REUMSBMB External (connection made outside the unit) master manifold kit. • REUMSBC1 Manifold slave cable. • REUMSBC2 Joiner for greater than five manifolded Rinnai INFINITY units. Refer appendix 3 ‘Manifolding components what to use where’ to determine manifolding components required. 38 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Appendices Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 39 Appendix 1 Water flow and gas usage When calculating the model of the Rinnai INFINITY required it is important to determine what the incoming water temperature will be. This is usually calculated on the worst case scenario (winter). For example: • Northland and Aucklanduse 15 °C • Bay of Plenty, Gisborne, and Hawke’s Bay use 10 °C • Waikato, Taranaki, Wanganui, Manawatu, Wairarapa, use 5 °C Wellington, and South Island Degree rise In the specification pages for the Rinnai INFINITY water heating range we express a parameter called ‘Nominal water capacity’. This means that at a 25 °C rise, the unit will produce a certain number of litres per minute of hot water. For example: • The VT26 external will produce 26 litres per minute at a 25 °C rise • The VT24 external will produce 24 litres per minute at a 25 °C rise Using the example above, for incoming water of 10 °C and a required temperature rise of 55 ° C, the VT26 external will produce 14.4 litres per minute at a 45 °C rise (55-10), and the VT24 external will produce 13.3 litres per minute at a 45 °C rise. Water flow and gas usage tables Use these tables to calculate model performance based on the incoming water temperature, and the required outlet temperature. 40 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY VT Temperature preset to 55 °C or less (mixed water) 5 °C temperature rise VT Approx. min. to L/min L/h Pressure Approx. gas model max. gas input loss consumption (MJ/h) through (MJ/h) unit (kPa) VT16 10-125 20.0 1200 75 31.0 VT20 13-160 24.0 1440 120 37.2 VT24 13-188 26.0 1560 170 40.3 VT26 13-199 26.0 1560 200 40.3 15 °C temperature rise VT16 10-125 20.0 1200 75 93.0 VT20 13-160 24.0 1440 120 111.6 VT24 13-188 26.0 1560 170 120.9 VT26 13-199 26.0 1560 200 120.9 25 °C temperature rise VT16 10-125 16.0 960 75 125.0 VT20 13-160 20.0 1200 120 160.0 VT24 13-188 24.0 1440 140 188.0 VT26 13-199 26.0 1560 200 199.0 35 °C temperature rise VT16 10-125 11.4 686 44 125.0 VT20 13-160 14.3 857 64 160.0 VT24 13-188 17.1 1029 70 188.0 VT26 13-199 18.6 1114 130 199.0 45 °C temperature rise VT16 10-125 8.9 533 29 125.0 VT20 13-160 11.1 667 42 160.0 VT24 13-188 13.3 800 40 188.0 VT26 13-199 14.4 867 80 199.0 10 °C temperature rise L/min L/h Pressure Approx. gas loss consumption through (MJ/h) unit (kPa) 20.0 1200 75 62.0 24.0 1440 120 74.4 26.0 1560 170 80.6 26.0 1560 200 80.6 20 °C temperature rise 20.0 1200 75 124.0 24.0 1440 120 148.8 26.0 1560 170 161.2 26.0 1560 200 161.2 30 °C temperature rise 13.3 800 60 125.0 16.7 1000 87 160.0 20.0 1200 100 188.0 21.7 1300 200 199.0 40 °C temperature rise 10.0 600 35 125.0 12.5 750 50 160.0 15.0 900 55 188.0 16.3 975 95 199.0 50 °C temperature rise 8.0 480 24 125.0 10.0 600 35 160.0 12.0 720 40 188.0 13.0 780 70 199.0 Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 41 Rinnai INFINITY HD Temperature preset to 55 °C or less (mixed water) HD model Approx. min. to max. gas input (MJ/h) HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx. gas loss consumption loss consumption through (MJ/h) through (MJ/h) unit (kPa) unit (kPa) 32 1920 200 47.8 32 1920 200 95.7 32 1920 200 47.8 32 1920 200 95.7 37 2220 200 55.3 37 2220 200 110.6 15 °C temperature rise 20 °C temperature rise 32 1920 200 143.5 32 1920 200 199.0 32 1920 200 143.5 32 1920 200 195.0 37 2220 200 165.9 37 2220 200 226.6 25 °C temperature rise 30 °C temperature rise 26 1560 200 199.0 21.7 1302 112.5 199.0 26 1560 200 195.0 21.7 1302 112.5 195.0 32 1920 140 250.0 26.7 1602 100 250.0 35 °C temperature rise 40 °C temperature rise 18.6 1116 75 199.0 16.3 978 60 199.0 18.6 1116 75 195.0 16.3 978 60 195.0 22.9 1374 60 250.0 20 1200 50 250.0 45 °C temperature rise 50 °C temperature rise 14.4 864 45 199.0 13 780 40 195.0 14.4 864 45 195.0 13 780 40 195.0 17.8 1068 40 250.0 16 960 40 250.0 42 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY HD Temperature preset to 75 °C (unmixed water) HD model Approx. min. to max. gas input (MJ/h) HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 HD200 16-199 HDi200 16-195 HD250 20-250 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx. gas loss consumption loss consumption through (MJ/h) through (MJ/h) unit (kPa) unit (kPa) 24 1440 200 34.8 24 1440 200 72.9 24 1440 200 34.8 24 1440 200 72.9 24 1440 200 36.4 24 1440 200 72.9 15 °C temperature rise 20 °C temperature rise 24 1440 200 104.3 24 1440 200 139.0 24 1440 200 104.3 24 1440 200 139.0 24 1440 200 109.3 24 1440 200 145.7 25 °C temperature rise 30 °C temperature rise 24 1440 200 173.8 21.7 1302 112.5 199.0 24 1440 200 173.8 21.7 1302 112.5 195.0 24 1440 200 182.2 24 1440 140 250.0 35 °C temperature rise 40 °C temperature rise 18.6 1114 75 199.0 16.3 975 60 199.0 18.6 1114 75 195.0 16.3 975 60 195.0 22.9 1371 130 250.0 20.0 1200 100 250.0 45 °C temperature rise 50 °C temperature rise 14.4 867 45 199.0 13.0 780 40 199.0 14.4 867 45 195.0 13.0 780 40 195.0 17.8 1067 80 250.0 16.0 960 70 250.0 55 °C temperature rise 60 °C temperature rise 11.8 709 36 199.0 10.8 650 33 199.0 11.8 709 36 195.0 10.8 650 33 195.0 14.5 873 50 250.0 13.3 800 45 250.0 65 °C temperature rise 70 °C temperature rise 10.0 600 31 199.0 9.3 557 29 199.0 10.0 600 31 195.0 9.3 557 29 195.0 12.3 738 40 250.0 11.4 686 35 250.0 75 °C temperature rise 80 °C temperature rise 8.7 520 29 199.0 8.1 488 29 199.0 8.7 520 29 195.0 8.1 488 29 195.0 10.7 640 30 250.0 10.0 600 25 250.0 Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 43 Rinnai INFINITY EF Temperature preset to 55 °C or less (mixed water) EF model Approx. min. to max. gas input (MJ/h) EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx. gas loss consumption loss consumption through (MJ/h) through (MJ/h) unit (kPa) unit (kPa) 30.0 1800 240.0 41.9 30.0 1800 240.0 79.3 37.0 2220 340.0 51.6 37.0 2220 340.0 97.8 37.0 2220 340.0 51.6 37.0 2220 340.0 97.8 15 °C temperature rise 20 °C temperature rise 30.0 1800 240.0 118.9 30.0 1800 240.0 162.0 37.0 2220 340.0 146.7 37.0 2220 340.0 195.6 37.0 2220 340.0 146.7 37.0 2220 340.0 195.6 25 °C temperature rise 30 °C temperature rise 24.0 1440 140.0 162.0 20.0 1200 80.0 162.0 32.0 1920 240.0 211.0 26.7 1600 171.0 211.0 32.0 1920 240.0 211.0 26.7 1600 171.0 211.0 35 °C temperature rise 40 °C temperature rise 17.1 1028.6 60.0 162.0 15.0 900 50.0 162.0 22.9 1371.4 130.0 211.0 20.0 1200 96.0 211.0 22.9 1371.4 130.0 211.0 20.0 1200 96.0 211.0 45 °C temperature rise 50 °C temperature rise 13.3 800.0 45.0 162.0 12.0 720 31.0 162.0 17.8 1066.7 82.0 211.0 16.0 960 61.9 211.0 17.8 1066.7 82.0 211.0 16.0 960 61.9 211.0 44 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Rinnai INFINITY EF Temperature preset to 75 °C (unmixed water) EF model Approx. min. to max. gas input (MJ/h) EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx. gas loss consumption loss consumption through (MJ/h) through (MJ/h) unit (kPa) unit (kPa) 24 1440 140 33.5 24 1440 140 63.4 24 1440 137 33.5 24 1440 137 63.4 24 1440 137 33.5 24 1440 137 63.4 15 °C temperature rise 20 °C temperature rise 24.0 1440 140 95.2 24.0 1440 140.0 126.9 24.0 1440 137 95.2 24.0 1440 137.0 126.9 24.0 1440 137 95.2 24.0 1440 137.0 126.9 25 °C temperature rise 30 °C temperature rise 24.0 1440 140 162.0 20.0 1200 80.0 162.0 24.0 1440 137 158.6 24.0 1440 137.0 190.3 24.0 1440 137 158.6 24.0 1440 137.0 190.3 35 °C temperature rise 40 °C temperature rise 17.1 1029 60 162.0 15.0 900 50.0 162.0 22.9 1371 130 211.0 20.0 1200 96.0 211.0 22.9 1371 130 211.0 20.0 1200 96.0 211.0 45 °C temperature rise 50 °C temperature rise 13.3 800 45 162.0 12.0 720 31.0 162.0 17.8 1067 82 211.0 16.0 960 61.9 211.0 17.8 1067 82 211.0 16.0 960 61.9 211.0 55 °C temperature rise 60 °C temperature rise 10.9 655 29 162.0 10.0 600 27.0 162.0 14.5 873 48.1 211.0 13.3 800 41.2 211.0 14.5 873 48.1 211.0 13.3 800 41.2 211.0 65 °C temperature rise 70 °C temperature rise 9.2 554 26 162.0 8.6 514 25.0 162.0 12.3 738 34.3 211.0 11.4 686 27.5 211.0 12.3 738 34.3 211.0 11.4 686 27.5 211.0 75 °C temperature rise 80 °C temperature rise 8.0 480 25 162.0 7.5 450 25.0 162.0 10.7 640 24.7 211.0 10.0 600 20.6 211.0 10.7 640 24.7 211.0 10.0 600 20.6 211.0 Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 45 Appendix 2 Rinnai INFINITY inbuilt frost protection Frost protection is fitted as standard on all Rinnai INFINITY models. Frost protection operates automatically, as required, whenever the appliance is connected to the electric power supply. How frost protection works When the temperature inside the unit drops below 3.5 °C the frost protection turns on, providing approximately 15 W of heat via electricity. Once the temperature inside the unit reaches 7 °C the frost protection switches itself off. The heat, provided by strategically placed ceramic heating elements, stops the water from freezing within the pipework of the unit. As frost protection requires electricity to run it is important that the unit is connected to the power supply at all times. If left off in an area prone to frost Rinnai recommend draining the appliance to prevent frost damage (not covered by warranty). ceramic heating element Long ceramic heating element inside a Rinnai INFINITY unit 46 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Appendix 3 Manifolding components what to use where MECS Master Position Internal* Code REUMSBM OR External** REUMSBMB Slave Joiner REUMSBC1 REUMSBC2 Number of water heaters * ** 2 1 1 - - 3 1 1 1 - 4 1 1 2 - 5 1 1 3 - 6 2 2 2 1 7 2 2 3 1 8 2 2 4 1 9 2 2 5 1 10 2 2 6 1 11 3 3 5 2 12 3 3 6 2 13 3 3 7 2 14 3 3 8 2 15 3 3 9 2 16 4 4 8 3 17 4 4 9 3 18 4 4 10 3 19 4 4 11 3 20 4 4 12 3 21 5 5 11 4 22 5 5 12 4 23 5 5 13 4 24 5 5 14 4 25 5 5 15 4 Internal: Master PCB located inside the Rinnai INFINITY External: Master PCB located outside the Rinnai INFINITY Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 47 Appendix 4 HD connection positions underneath unit (mm) HD200 external Front of unit HD200 ext 4 1 3 2 1 Gas connection from wall Gas connection from centre 103 89 2 Cold water inlet from wall Cold water inlet from centre 74 27 3 Hot water outlet from wall Hot water outlet from centre 95 110 4 Electrical connection from wall Electrical connection from centre 160 21 Wall bracket HDi200 internal HDi200 ext Front of unit (cover not on) 4 1 3 1 Gas connection from wall Gas connection from centre 99~139 89 2 Cold water inlet from wall Cold water inlet from centre 70~110 27 3 Hot water outlet from wall Hot water outlet from centre 91~131 110 4 Electrical connection from wall Electrical connection from centre 160~200 21 2 Wall bracket Please note: Cover is not showing in image HD250 external HD250 ext Front of unit 4 3 2 1 Gas connection from wall Gas connection from centre 61 110 2 Cold water inlet from wall Cold water inlet from centre 99 52 3 Hot water outlet from wall Hot water outlet from centre 115 61 4 Electrical connection from wall Electrical connection from centre 2 100 1 Wall bracket 48 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 Appendix 5 EF connection positions underneath unit (mm) EF24 external EF24 ext Front of unit 4 3 2 1 5 Wall bracket 1 Gas connection from wall Gas connection from centre 70.5 25 2 Cold water inlet from wall Cold water inlet from centre 83 53 3 Hot water outlet from wall Hot water outlet from centre 164.5 100 4 Electrical connection from wall Electrical connection from centre 175 10 5 Condensate outlet from wall Condensate outlet from centre 33 132 EFi250 internal EFi250 int Front of unit (cover not on) 4 5 3 2 1 Wall bracket 1 Gas connection from wall Gas connection from centre 89~129 103.2 2 Cold water inlet from wall Cold water inlet from centre 64.6~104 27.7 3 Hot water outlet from wall Hot water outlet from centre 100~140 100 4 Electrical connection from wall Electrical connection from centre 200~240 49 5 Condensate outlet from wall Condensate outlet from centre 122.6 195 Please note: Cover is not showing in image EF250 external EF250 ext Front of unit 4 5 3 2 1 Wall bracket 1 Gas connection from wall Gas connection from centre 89 103.2 2 Cold water inlet from wall Cold water inlet from centre 64.6 27.2 3 Hot water outlet from wall Hot water outlet from centre 100 100 4 Electrical connection from wall Electrical connection from centre 200 49 5 Condensate outlet from wall Condensate outlet from centre 122.6 195 Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 49 Appendix 6 LPG gas bottle consumption and cylinder clearances LPG gas bottle consumption Overview of LPG cylinder clearances We often get asked about how long a gas bottle will last when running a gas appliance. Using the calculation below you can work this out yourself. LPG gas bottle energy calculation 1 kg of LPG gas contains 50.4 MJ of energy. This means that a 45 kg LPG has bottle has 45 kg x 50.4 MJ = 2268 MJ. This calculation works for different gas bottle sizes, here are the most common: • 9 kg = 453.6 MJ • 45 kg = 2268 MJ • twin pack = 4536 MJ (two 45 kg gas bottles) B A C D Calculating how long an LPG bottle will last To work out how many hours an LPG bottle will last you need to divide the energy (MJ) of the gas bottle by the total MJ input of the appliance. A Min. clearance to a door 1m B Min. clearance to an openable window 150 mm For example A household has a VT26 installed which runs approximately 20 minutes a day, three five minute showers and intermittent use of vanity and kitchen taps (approx. five minutes). D Min. clearance to a drain • 2268 ÷ 199 MJ/h (maximum input of unit) = 11.40 hours (running at full capacity) • 11.40 hours x 60 minutes = 684 minutes • 684 minutes ÷ 20 minutes (use per day) = 34.2 days (approx. one 45 kg per month) The above example is based on the unit operating at a maximum flow rate and MJ/h input (26 L/min and 199 MJ/h). In the real-world this won’t be the case as the flow rate and gas consumption when using vanity and kitchen taps is much lower (2.4 L/min and 13 MJ/h), so in reality the gas bottle will last a little longer. Please note: This doesn’t factor other gas appliances in the house. For more information you can search the internet (how long will a 45 kg gas bottle last) as there are additional resources and blogs available. 50 | Rinnai INFINITY gas continuous flow water heating specification guide 03-15 C Min. clearance to an air vent or opening 1 m 1m The above diagram is a modified version of a drawing originally produced by ongas (www.ongas.co.nz). It is intended to provide an overview of the general clearances required for LPG cylinders. For detailed information relating to LPG cylinder placement it is advisable to consult a licensed gasfitter, your nearest LPG cylinder supplier, or consult AS/NZS 5601.1 Gas Installations. Appendix 7 Gas boosted solar Rinnai INFINITY models can be easily plumbed to provide additional heat to a solar hot water system to heat water when the solar hot water is not available. How a gas boosted system works 1. The sun’s rays heat water in the solar panels. 2. Hot water from the panels is stored in the tank. 3. If the water is too cold, the Rinnai INFINITY gas boost heats the water on demand as it travels from the tank to the tap. 1 3 2 The size of the Rinnai INFINITY depends on the number of bathrooms, select the Rinnai INFINITY model as if solar hot water was not available. Recommended system layout using a Rinnai INFINITY and flow diversion valve Rinnai INFINITY gas continuous flow water heating specification guide 03-15 | 51 Experience our innovation Rinnai.co.nz 0800 746 624 http://www.youtube.com/rinnainz http://www.facebook.com/rinnainz
© Copyright 2026 Paperzz