FPC hook – revisited April 2014 OLD VERSION LATEST NEW VERSION Increased fm to enlarge coupling. Hook does not need to penetrate so deep into port tube. Enlarged cross section for better heat flow (from circular to elliptical cross section). Round section. QextFPC -- P0FPC W 4.87e5 4.87e5 600 106 Too large power loss difficult to cool down. High amount of radiated heat in consequence. - Field offset = 0.22mm - Minimum distance of 6.25mm between hook end plate and wall. Multipacting? - Cooling along the hook? Power losses in flange gasket of HOM port tubes Use RF seal copper gasket for: 1) significant reduction of power losses in flanges interconnection and 2) enhanced leak tightness. Port tube Flange 0.003m 0.031m RF-seal gasket Filter must be detachable! Power losses in flange gasket of HOM port tubes Vdefl=1.038MV Evaluated power loss for a 3mm-height ring Top HOM1 at a distance from the cavity center that varies from 211 to 219mm (between hook capacitance 219mm 211mm and first inductive rod). Gasket position* mm 211-214 214-217 217-220 220-223 223-226 226-229 Top HOM1 Bot HOM2 Bot HOM3 Power loss (in 3mm heigth I.D. 62mm Cu gasket) W 7.313727537 7.916753808 7.959449013 6.848096523 7.448041806 7.559266434 6.516323567 7.108316969 7.247232251 6.383518757 6.977828909 7.112640124 6.549276743 6.958551969 7.234703821 7.071746576 7.373582196 7.789950541 *For Vdelf=3.34MV. Anomalous skin effect of copper at 2K and 400MHz (Rs~0.8mOhm) and surface roughness contribution (30%). 7 W in each port gasket… • Nb-coated copper gaskets? • Extend coax line between hook and filter? Bot HOM3 Bot HOM2 Power losses in flange gasket of HOM port tubes Plus reduce HOM port length for clearance purposes Move first inductive rod away from hook