www.hvac.vn Electromagnetic Flowmeters he materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees www.hvac.vn as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used Overview Principles of Operation Types of Electromagnetic Flow Sensors Insertion In-line Installation Accessories Rate and Totalizers Analog Transmission Target Markets Application Photos and Uses www.hvac.vn Overview Insertion Adjustable LOFM MFS IEFS Fixed MFS2 EFS2 In-line IEFS Small LOFM & MFS/MFS2 Large www.hvac.vn FLMG FLMG EFS2 Principle of Operation Faraday’s Law Conductive liquid moving through a magnetic field produces a current www.hvac.vn Principle of Operation Current is proportional to velocity of the liquid www.hvac.vn Principle of Operation A magnetic field is directed through the conductive liquid Voltage generated is proportional to the movement of the flowing liquid www.hvac.vn IEFS - Introduction Adjustable, insertion electromagnetic flow meter Designed for pipe sizes from 3 to 48˝ ( 76 to 1219 mm) Comes in different materials Stainless steel and brass Purchase by size and material www.hvac.vn IEFS - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s) Accuracy: ±1% FS Output: Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20 ft/s Enclosure Rating: NEMA 4X (IP66) www.hvac.vn IEFS - Features Field adjustability allows for quick ship and installation time Brass and stainless steel materials of construction Versatility for higher temperature and pressures and varying fluids Reverse flow output option Allows meter to indicate flow in two directions, forward or reverse www.hvac.vn IEFS - Features NPT or Hot-Tap process connection Hot-Tap option allows for service of system without draining process fluid www.hvac.vn EFS2 - Introduction Electromagnetic flow meter Fixed insertion depth 1 to 12” (25 to 305 mm) PVC, Brass, and Stainless Steel www.hvac.vn EFS2 - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s) Accuracy: ±1% FS Output: Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20 ft/s Enclosure Rating: NEMA 4X (IP66) www.hvac.vn EFS2 - Features Fixed depth 3 models allow for range of pipe sizes 1 to 3” (25 to 76 mm) 4 to 10” (102 to 254 mm) 12” (305 mm) PVC, Brass, and Stainless Steel Materials of Construction Versatility for higher temperature and pressures Higher chemical compatibility for varying fluids Reverse flow output option Allows meter to indicate flow in two directions, forward or reverse www.hvac.vn EFF Fittings Series EFF fittings and tees required for installation Stainless Steel, Bronze, and PVC fittings and tees allow for installation in virtually all applications www.hvac.vn Advantages and Disadvantages IEFS2 – Adjustable NPT and Hot Tap Mount One model for pipes 3 to 24” (76 to 607 mm) Higher Cost www.hvac.vn EFS2 - Fixed Lower Cost Operational in pipes down to 1” (25 mm) Require additional mounting components LOFM - Introduction In-line, small pipe diameter electromagnetic flow sensor PVDF wetted material 3/8” (9.5 mm) & ¾” (19 mm) www.hvac.vn LOFM - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.03 to 20 GPM (0.01 to 1.3 LPS) Accuracy: +1% of reading Output: Current sinking, square wave pulse, opto-isolated, 30 VDC @ 5 mA max. and 4 to 20 mA Enclosure Rating: NEMA 4X (IP66) www.hvac.vn LOFM - Features Corrosion resistant PVDF material No moving parts Non obstructive flow Can accurately measure flow rates as low as 0.03 GPM (.002 LPS) www.hvac.vn MFS & MFS2 - Introduction In-line electromagnetic flowmeter For small pipe sizes MFS 316 SS body ½ to 1” (13 to 25 mm) MFS2 plastic body MFS ½ to 1-1/4” (13 to 32 mm) MFS2 www.hvac.vn MFS & MFS2 - Specifications Service: Water and other conductive liquids Accuracy: ±2% of reading Output: Frequency: Square-wave, NPN Analog: 4 to 20 mA MFS Enclosure Rating: NEMA 4 (IP65) MFS2 www.hvac.vn MFS & MFS2 – Features Compact design Low cost No moving parts Ideal for lower flows Lower pipe sizes MFS MFS2 www.hvac.vn FLMG - Introduction Inline electromagnetic flowmeter Transmits and displays flow rate and total 150 # ANSI flange 4, 6, 8, 10 in (102, 153 ,203, 254 mm) www.hvac.vn FLMG - Specifications Service: Compatible non-coating conductive liquids Wetted Materials: Liner: Dual durometer rubber Accuracy: ±1% Output: Current sinking square wave pulse, optoisolated Battery Life: 2 months with power failure; 10 years with power Enclosure Rating: NEMA 4X (IP66) www.hvac.vn FLMG - Features No Moving Parts Unaffected by potential debris in flow such as sand Manufactured to customer specification Model designed to mount in 4 to 10” (102 to 254 mm) lines No adjusting sensor height to center of flow, bolt inline an go Larger magnetic field Requires fewer upstream and downstream pipe diameters www.hvac.vn FLMG - Features NEMA 4X (IP66) rated housing Allows for use both indoor and outdoor Flow outputs Rate and flow totalizing standard Internal battery backup standard Allows unit to continue working if power failure/outage occurs www.hvac.vn Advantages and Disadvantages In-line vs. Insertion Built to specific pipe size, one size does not fit all Flow-thru design allows for minimal/no pressure drop Can be used in applications with solids and debris in flow stream Higher cost than insertion flow sensors www.hvac.vn Installation Accessories RTI Rate/Total Indicator BAT Blind Analog Transmitter www.hvac.vn RTI - Features Indicator and transmitter accessory for IEFS, EFS2, and FLMG Takes pulse input from flow sensor and converts signal to display flow rate and total Displays flow rate and flow total on LCD display Provides linear 4 to 20mA output of flow NEMA 4X (IP 66) rating for indoor and outdoor use www.hvac.vn RTI - Features Mounts to wall, flow sensor, or local panel www.hvac.vn BAT - Features Transmitter accessory for IEFS, EFS2, and FLMG No Display, blind unit Takes pulse input from flow sensor and converts signal to flow rate signal Output signal linear 4 to 20mA output of flow NEMA 4X (IP 66) rating for indoor and outdoor use www.hvac.vn BAT - Features Mounts to wall or Flow Sensor www.hvac.vn When not to recommend electromagnetic flow sensors Applications with fluids with low conductivity De-ionized water or boiler feed water Low conductivity can cause the meter to turn off and indicate zero flow Hydrocarbon and gas applications Hydrocarbons and gases are non conductive and can not be measured www.hvac.vn Applications Agriculture Irrigation Sprayers and Spreaders Fertigation Building Automation HVAC Systems Municipalities Water and Wastewater Industrial Process Chemical Metering Pumps www.hvac.vn Agriculture Irrigation Used for measuring and monitoring water consumed during growing season on pivot systems Sprayers Used for monitoring chemical sprayed on crops during growing season Spreaders Used for monitoring flow of organic materials, including manure, used as fertilizer www.hvac.vn Building Automation Water audits and consumption Used to verify water intake to building, verified against city municipality billing LEED Used to verify water consumption for LEED credits in buildings for water conservation www.hvac.vn Municipalities Wastewater Facilities Used to measure treated and untreated sewage Used to measure process water Used to measure chemical flow for sewage treatment Water Facilities Used for measuring flow in water mains Used for early indication of water main break www.hvac.vn Irrigation Magnetic Flowmeter used for flow measurement in Pivot Irrigation system www.hvac.vn Spreader Magnetic Flowmeter used in manure spreading system www.hvac.vn Fertigation Golf course groundwater monitoring and fertilizing www.hvac.vn HVAC System Magnetic Flowmeter used for billing in a heating system www.hvac.vn Water Magnetic Flowmeter used in pump house for groundwater monitoring www.hvac.vn Wastewater Gravity-fed waste pumping facility www.hvac.vn Industrial Magnetic Flowmeter used in water park pump and treat www.hvac.vn The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc. www.hvac.vn
© Copyright 2026 Paperzz