5540StoneCrossingDriveWinston-Salem,NC27104 [email protected] (336)645-5112 JohnDoe 123MainSt Anywhere,NC DearJohn, On11/16/2015,HomeTeamInspectionServicemadeavisualinspectionofthepropertyreferencedabove. Enclosedpleasefindawritten,narrativereportofourfindingsinaccordancewiththetermsofourHome InspectionAgreement.Althoughmaintenanceitemsmayhavebeenaddressedverballyatthetimeofthe inspection,theymaynotbeincludedintheenclosedreport. Itrusttheenclosedinformationwillhelpyoumakeaninformeddecision.IfIcanbeofanyassistance,please feelfreetocallmeat(336)645-5112.Enjoyyournewhome! Sincerely, KyleBranyon,License#3292 DerwinDodson,License#3482 Page1of20 home inspection report Home. Safe. Home. Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home inspection is to visually examine the readily accessible systems and components of the home. The inspectors are not required to move personal property, materials or any other objects that may impede access or limit visibility. Items that are unsafe or not functioning, in the opinion of the inspector, will be described in accordance with the standards of practice by which inspectors abide. What does this report mean to you? This inspection report is not intended as a guarantee, warranty or an insurance policy. Because your home is one of the largest investments you will ever make, use the information provided in this report and discuss the findings with your real estate agent and family to understand the current condition of the home. Our inspections exceed the highest industry standards. FAST Because we use a team of inspectors, each an expert in his or her field, our inspections are performed with greater efficiency and more expertise and therefore exceed the highest industry standards. We are pleased to provide this detailed report as a service to you, our client. TRUSTED We believe in your dream of home ownership. We want to help you get into your dream home. Therefore, we take great pride in assisting you with this decision making process. This is certainly a major achievement in your life. We are happy to be part of this important occasion and we appreciate the opportunity to help you realize your dream. We exceed your expectations. Buying your new home is a major decision. Much hinges on the current condition of the home you have chosen. That is why we have developed the HomeTeam Inspection Report. Backed by HomeTeam’s experience with hundreds of thousands of home inspections over the years, the report in your hand has been uniquely designed to meet and exceed the expectations of today’s homebuyers. We are proud to deliver this high-quality document for your peace of mind. If you have any questions while reviewing this report, please contact us immediately. Thank you for allowing us the opportunity to serve you. ACCURATE FileNumber:655439 AddressofInspection:123MainSt HomeTeamInspectionService Page2of20 FileNumber:655439 AddressofInspection:123MainSt PREFACE: Thisreportisintendedforthesole,confidential,andexclusiveuseandbenefitoftheClient(s)underawrittenHomeTeam InspectionAgreement.Thisreportisnotintendedforthebenefitof,andmaynotberelieduponby,anyotherparty.The disclosureordistributionofthisreporttothecurrentowner(s)ofthepropertyinspectedortoanyrealestateagentwillnotmake thosepersonsintendedbeneficiariesofthisreport.TheHomeTeamInspectionServicehasnoliabilitytoanyparty(otherthan theHomeTeamclientnamedabove,forwhomthisreportwasexpresslyprepared)foranyloss,damageorexpense(including, withoutlimitation,attorneyfees)arisingfromanyclaimrelatingtothisreport. Ahomeinspectionisintendedtoassistinevaluationoftheoverallconditionofthedwelling.Theinspectionisbasedon observationofthevisibleandapparentconditionofthestructureanditscomponentsonthedateoftheinspection.Wewillnot renderanopinionastotheconditionofanysystemsorcomponentsofthestructurethatareconcealedbywalls,floors,drywall, paneling,suspendedceilingtiles,insulation,carpeting,furnitureoranyotheritemsstoredinoronthepropertyatthetimeofthe inspection. Theresultsofthishomeinspectionarenotintendedtomakeanyrepresentationregardingthepresenceorabsenceoflatentor concealeddefectsthatarenotreasonablyascertainableinacompetentlyperformedhomeinspection.Nowarrantyorguaranty isexpressedorimplied. Ifthepersonconductingyourhomeinspectionisnotalicensedstructuralengineerorotherprofessionalwhoselicense authorizestherenderingofanopinionastothestructuralintegrityofabuildingoritsothercomponentparts,youmaybeadvised toseekprofessionalopinionastoanydefectsorconcernsmentionedinthereport.Iftheage,conditionoroperationofany system,structureorcomponentofthepropertyisofaconcerntoyou,itisrecommendedthataspecialistintherespectivefield beconsultedforamoretechnicallyexhaustiveevaluation. Thishomeinspectionreportisnottobeconstruedasanappraisalandmaynotbeusedassuchforanypurpose. Thisinspectionreportincludesadescriptionofanymaterialdefects*notedduringtheinspection,alongwithany recommendationthatcertainexpertsberetainedtodeterminetheextentofthedefectsandanycorrectiveactionthatshouldbe taken.Anymaterialdefectthatposesanunreasonablerisktopeopleonthepropertywillbeconspicuouslydefinedassuch.Any recommendationsmadetoconsultwithotherspecialistsforfurtherevaluationasaresultofourfindingsshouldbecompleteprior totheconclusionoftheinspectioncontingencyperiod.TheClientwarrantstheywillreadtheentireInspectionReportwhen receivedandshallpromptlycontactHomeTeamregardinganyquestionsorconcernstheClientmayhaveregardingthe inspectionortheInspectionReport. MaterialDefect:Aproblemwitharesidentialrealpropertyoranyportionofitthatwouldhaveasignificantadverseimpacton thevalueofthepropertyorthatinvolvesanunreasonablerisktothepeopleontheproperty.Thefactthatastructuralelement, systemorsubsystemisnear,atorbeyondtheendofthenormalusefullifeofsuchastructuralelement,systemorsubsystem isnotbyitselfamaterialdefect. Themajorityofhomeinspectionsareperformedonpre-existingstructures.Thesestructuresrangeinagefromnewconstruction tohistoriccenturyhomes.Buildingtechniqueshavechangeddramaticallyoverthedecades.Theageandmethodof constructionaffectsthecharacterofindividualhomesandentireneighborhoods,andoftenaffectabuyer'sdecisiontopurchase onehomeoveranother. Wewillnotdeterminethecauseofanyconditionordeficiency,determinefutureconditionsthatmayoccurincludingthefailureof systemsandcomponentsorconsequentialdamageorcomponentsordeterminetheoperatingcostsofsystemsorcomponents. Itisnotuncommontoobservecracksorforcrackstooccurinconcreteslabsorexteriorandinteriorwalls.Cracksmaybecaused bycuringofbuildingmaterials,temperaturevariationsandsoilmovementsuchas:settlement,unevenmoisturecontentinthe soil,shockwaves,vibrations,etc.Whilecracksmaynotnecessarilyaffectthestructuralintegrityofabuilding,cracksshouldbe monitoredsothatappropriatemaintenancecanbeperformedifmovementcontinuesatanabnormalrate.Properfoundation maintenanceiskeytothepreventionofinitialcracksorcracksenlarging.Thisincludes,butnotlimitedtoproperwatering, foundationdrainageandremovalofvegetationgrowthnearthefoundation. Page3of20 FileNumber:655439 AddressofInspection:123MainSt SUMMARYPAGE Thissummaryisnottheentirereport.Thefullreportmayincludeadditionalinformationofinterestor concerntotheclient.Itisstronglyrecommendedthattheclientpromptlyreadthecompletereport. Forinformationregardingthenegotiabilityofanyiteminthisreportunderarealestatepurchase contract,contactyourNorthCarolinarealestateagentoranattorney. Exterior 1. Thereisaflat/negativeslopeatrearrightofthehouse.Thisisawaterpenetrationconcern. Recommendregradingtodrainwaterawayfromhome. 2. Vegetationtouchingfrontsideofthehouse.Itisrecommendedtohavean18-24inchclearance betweenvegetationandsidingtominimizemoisture/pestconcerns.Recommendrepairsby qualifiedperson. 3. Unsealedpenetrationsthroughbrickworkinareasatbutnotlimitedtorightsidearounddryer vent,andleftsidearoundHVACpipingandwaterspigot.Thisisawaterpenetrationconcern. Recommendrepairsasnecessary. 4. Openmortarjointsobservedatrightsideporch/patio.Thisisawaterpenetration/settlement concern.Recommendrepairsbyaqualifiedperson. Roof 1. 1. Raisedshinglesatbutnotlimitedtothefrontandrearroofofthehouse.Thisisawater penetration/windlift/nailwearthroughconcern. 2. Damagedshinglesobservedonareasatbutnotlimitedtothefront,rearright,andrear roof.Thisisawaterpenetration/substratedamageconcern. Recommendreviewandrepairsasdirectedbyqualifiedcontractor. Garage 1. Therearmostgaragedoordidnotreversewhenmetwithreasonableresistance(astestedwitha 2x4block).Thisisasafetyconcern.Recommendrepairs/adjustmentsbyqualifiedpersonand verifyingproperoperationpriortoclosing. Attic 1. Observeddamagedroofdeckingattherightrearoftheattic.Thisisasupportconcern. Recommendrepairsbyaqualifiedcontractor. 2. Exhaustventstackintherightrearatticspacehadlightvisiblearoundbootareaandstained OSBdeckingbelowindicatingpossibleleak.Thisisapossibleleakage/damageconcern. Recommendreviewandrepairsasdirectedbyqualifiedcontractor. 3. LVLframingatthefrontrightofhouseisnotfullybearingattheheelcut.Thisisa support/installation/damageconcern.Recommendrepairsasdirectedbyqualifiedcontractor. Interiors 1. Windowpaneaboverearentrydoorofthehomewascrackedatthetimeoftheinspection.This isadamageconcern.Recommendrepairsbyaqualifiedcontractor. Bathrooms Page4of20 FileNumber:655439 AddressofInspection:123MainSt 1. Unsealedareasatbathsurroundsinthemasterandupstairsbathrooms.Thisisawater penetration/substratedamageconcern.Recommendrepairsbyqualifiedperson. 2. Gapobservedbetweenbottomofjettedtubandsubfloor.Thisisasupport/damageconcern. Recommendrepairsbyaqualifiedcontractor. 3. Observedlooseshowerstemsintheupstairsanddownstairshallwaybathrooms.Thisisa movementconcern.Recommendrepairsbyaqualifiedperson. WaterHeater 1. Waterheaterexhaustventiscontactingcombustiblesnearunit.Thereistypicallya1inchgap tocombustiblestominimizesafety/damageconcerns.Recommendrepairs. Electrical 1. Openjunctionboxobservedatbutnotlimitedtotherearleftofcrawlspace.Thisisa damage/shockconcern.Recommendrepairsbyaqualifiedperson. Plumbing 1. Waterlinesinareasatbutnotlimitedtothecenterofthecrawlspacearenotfullysupported. Thisisamovement/damageconcern.Recommendrepairsbyqualifiedperson. 2. 1. Staining/elevatedmoistureunderneathmasterbathstallshower.Thisisa leakage/substratedamageconcern. 2. Leakingobservedaroundmasterbathjettedtubintothecrawlspace.Thisisa leakage/substratedamageconcern. Recommendevaluationandrepairsasdirectedbyqualifiedcontractor. Foundation/Structural 1. 1. Stainingonfoundationwall,andaroundventopeningsatareasaroundthehouse.This isawaterpenetration/adversemoistureconcern. 2. Foundationventshavebeenblocked/coveredupattherightandrearofhouse.This maynotallowforproperairflow/ventilation. Recommendrepairsasnecessarybyqualifiedperson. Page5of20 FileNumber:655439 AddressofInspection:123MainSt GENERALDESCRIPTION Theintentofthisreportistoprovidetheclientwithanunderstandingofthepropertyconditionsatthetimeof thehomeinspection.Unlessotherwiselistedasalimitation,thisinspectioncoversallreadilyvisibleand readilyaccessibleinstalledsystemsandcomponentsdescribedintheNorthCarolinaHomeInspector LicensureActStandardsofPractice. Theprimarypurposeforahomeinspectionistoidentifydefectsandsafetyconcerns.Theconditionofpaint, wallcoverings,carpeting,windowtreatments,etc.,arenotaddressed.Routinemaintenanceitemsarenot withinthescopeofthisinspectionunlesstheyotherwiseconstitutevisuallyobservabledefects. Wheredefectsorsafetyconcernsareobserved,thisreportstrivesto1)describethesystemorcomponent,2) statehowtheconditionisdefective3)explaintheimplicationsofthedefectand4)directtheclienttoacourse ofactionforrepair,furtherinvestigationbyaspecialist,orsubsequentobservation. Throughoutthisreport,theterms"right"and"left"areusedtodescribethehomeasviewedfromthestreet. Atthetimeoftheinspection,theapproximateoutdoortemperaturewas50to60degreesFahrenheit,andthe weatherwassunnyandclear.Thebuyerandthebuyersagentwerepresent.Theutilitieswereon.According tothesellersdisclosurethehomewasbuiltin2006. EXTERIOR Theinspectedproperty'ssidingconsistedofbrickveneerandvinyl Trimmaterialsatthehomeconsistedofvinyl. Therewereconcernsobservedonthevisibleportionsofthesiding,trim,eaves,soffits,and/orfascias. Unsealedpenetrationsthroughbrickworkinareasatbutnotlimitedtorightsidearounddryervent, andleftsidearoundHVACpipingandwaterspigot.Thisisawaterpenetrationconcern.Recommend repairsasnecessary. Unsealed-Right Allaccessibleexteriordoorswereoperatedduringtheinspection.Therewereconcernsobservedononeor moreoftheexterior/entrydoorsandwindows.SeeInteriorcommentsbelow. Page6of20 FileNumber:655439 AddressofInspection:123MainSt HomeTeamvisuallylooksatthelotandgradingaroundthehometomakesurethesoilisslopedawayfrom thehousetopreventwaterpenetration.Therewereconcernsobservedwiththevegetation/gradingaround thehome. Thereisaflat/negativeslopeatrearrightofthehouse.Thisisawaterpenetrationconcern. Recommendregradingtodrainwaterawayfromhome. Vegetationtouchingfrontsideofthehouse.Itisrecommendedtohavean18-24inchclearance betweenvegetationandsidingtominimizemoisture/pestconcerns.Recommendrepairsbyqualified person. Vegetationathouse-Front Therewereconcernsobservedontheporchofthehome. Openmortarjointsobservedatrightsideporch/patio.Thisisawaterpenetration/settlementconcern. Recommendrepairsbyaqualifiedperson. Openjoints-Right Thedeckofthehomewasattachedtothehouseandwassupportedbycolumns/piers.Therewereno concernsobservedondeck(s). Page7of20 FileNumber:655439 AddressofInspection:123MainSt DRIVEWAY Walkwaysanddrivewaysareinspectedforpotentialtriphazardsandmajorcracking/spalling.Minorcracking andspallinginwalkwaysanddrivewaysdevelopandprogresswithageandareconsiderednormalaslongas theydonotcreateasafetyhazard.Therewerenoconcernsobservedinthewalkwayand/ordriveway. ROOF Theroofwasagable,hipandsheddesigncoveredwithasphalt/fiberglassshingles.Observationoftheroof surfaces,flashing,skylightsandpenetrationsthroughtheroofwasperformedfromaladderatthebaseand fromthegroundwiththeaidofbinoculars.Inspectorsarenotrequiredtogetontheroof,andwillonlywalkon surfacesthataredeterminedbytheinspectortobesafeandaccessible. Roofflashingsarenotfullyvisibleandmaybeconcealedinareas.Clientmaywishtoreviewfurtherifadverse conditionsareobserved.Thisvisualroofinspectionisnotintendedasawarrantyoranestimateonthe remaininglifeoftheroof.Anyroofmetal,especiallytheflashingandvalleys,mustbemaintainedforthelifeof theroof. Therewereconcernsobservedontheroofand/orroofpenetrations. 1. Raisedshinglesatbutnotlimitedtothefrontandrearroofofthehouse.Thisisawater penetration/windlift/nailwearthroughconcern. 2. Damagedshinglesobservedonareasatbutnotlimitedtothefront,rearright,andrearroof. Thisisawaterpenetration/substratedamageconcern. Recommendreviewandrepairsasdirectedbyqualifiedcontractor. Damage-Front Damage-Rear Page8of20 FileNumber:655439 AddressofInspection:123MainSt Damage-Rear Damage-Frontright Guttersanddownspoutsarevisuallyinspected.HomeTeamcannotdeterminethedrainingcapabilitiesof guttersystems,butwilllookforvisiblesignsofanyissues.Guttersanddownspoutsshouldreceiveroutine maintenancetopreventprematurefailure.Therewerenoconcernsobservedonthevisibleportionsofthe guttersordownspouts. GARAGE Therewasanattachedgarageatthehouse.Anydetachedgaragesarenotinspectedastheyareoutsidethe scopeofahomeinspection.Thegaragedooristestedusinginstalledcontrols,andtestedforsafetydevices includingreversalwhenmetwithreasonableresistancewitha2x4blockorbyanothermethodasrequiredby manufacturer.Thefunctionalityofremotetransmitters,keylessentry,orotheropeningdevicesarenottested duringthehomeinspection.Therewereconcernsobservedinthegarage. Therearmostgaragedoordidnotreversewhenmetwithreasonableresistance(astestedwitha2x4 block).Thisisasafetyconcern.Recommendrepairs/adjustmentsbyqualifiedpersonandverifying properoperationpriortoclosing. Didnotreverse Page9of20 FileNumber:655439 AddressofInspection:123MainSt ATTICSTRUCTURE Aswithallaspectsofthehomeinspection,atticandroofinspectionsarelimitedinscopetothevisibleand readilyaccessibleareas.Manyareasoftheroofarenotvisiblefromtheatticespeciallynearthebase,where thelargestvolumeofwaterdrains.Thepresenceoforactivestatusofroofleakscannotbedetermined unlesstheconditionswhichallowleakstooccurarepresentatthetimeoftheinspection.Pleasebeaware thatrainaloneisnotalwaysaconditionthatcausesaleaktorevealitself.Theconditionsthatcauseleaksto occurcanofteninvolvewinddirection,thelengthoftimeitrains,etc.Theinspectiondoesnotofferorimplyan opinionorwarrantyastothepast,presentorfuturepossibilityofroof,skylight,flashingorventleaks. Theatticwasinspectedfrominstalleddecking,withacameraandflashlight.Theatticabovethelivingspace wasinsulatedwithbattedandloosefillinsulation.Ventilationthroughouttheatticwasprovidedbyridgeand soffitvents.Anatticfanwasnotinstalled.TheroofwasframedwithLVLs,raftersandOSBsheathing. Therewereconcernsobservedintheatticorroofstructure. Observeddamagedroofdeckingattherightrearoftheattic.Thisisasupportconcern.Recommend repairsbyaqualifiedcontractor. Damaged ExhaustventstackintherightrearatticspacehadlightvisiblearoundbootareaandstainedOSB deckingbelowindicatingpossibleleak.Thisisapossibleleakage/damageconcern.Recommend reviewandrepairsasdirectedbyqualifiedcontractor. Penetratingdaylight-attic Deckstainingbelowexhaustvent-attic LVLframingatthefrontrightofhouseisnotfullybearingattheheelcut.Thisisa Page10of20 FileNumber:655439 AddressofInspection:123MainSt support/installation/damageconcern.Recommendrepairsasdirectedbyqualifiedcontractor. Notfullybearing KITCHEN Built-inappliancesonlywereoperatedforfunctionalityinkitchen.Inspectordidnotcheckthefunctionalityof anyclocksortimers,anddidnotinspectanyrefrigeratorsastheyareconsideredpersonalproperty.No considerationisgivenregardingtheageorcomponentsthatmaybewornorotherwiseaffectedbywearand tearoruse.Nowarranty,expressorimplied,isgivenforthecontinuedoperationalintegrityoftheappliances ortheircomponents. Theinstalleddishwasherwasrunthroughanormalcycleduringtheinspection. Theinstalleddisposalwasinspectedandoperatedduringtheinspection.Theefficiencyratingandchopping/ grindingabilityoftheunitisnotwithinthescopeoftheinspection. Therewasagascooktopandelectricoveninstalledinthekitchen. Kitchenwasfoundtohavearecirculatingexhaustsource.Theexhaustcapacityisnotwithinthescopeofthis inspection.Cleaningthefanandfiltermayincreasetheexhaustcapability. Therewasamicrowavepermanentlyinstalledinthekitchen.Onlypermanentlyinstalledmicrowavesare testedduringinspection. Therewasnotatrashcompactorinstalledinthekitchen. Page11of20 FileNumber:655439 AddressofInspection:123MainSt INTERIORS HomeTeaminspectsforvisibleareasofconcernandsafety.Theconditionofcosmeticitemssuchas:paint, wallcoverings,carpeting,windowtreatments,blinds,etc.,arenotaddressed.Possibleproblemareasmaynot beidentifiediftheinteriorwallandceilingsurfaceshavebeenrecentlypainted/covered.Inspectionsareoften limitedintheinteriorsbystorage/belongings/furniture,wallpaper,arearugs,andanyoccupiedrooms. HomeTeamdoesnotmoveanypersonalbelongingsduringtheinspection.Thestructuralcomponentsofthe wallsandceilingswerenotinspectedastheywerenotvisibleduetowallcoverings.Washeranddryerunits arenotinspectedoroperatedaspartofastandardhomeinspection.Avisualinspectionofconnections, vents,andvisibleleaksaremadewhenvisible.Therewereconcernsobservedintheinteriorofthehome. Windowpaneaboverearentrydoorofthehomewascrackedatthetimeoftheinspection.Thisisa damageconcern.Recommendrepairsbyaqualifiedcontractor. Crackedwindowpane-rearentrydoor FIREPLACE Theinspectionoffireplacesinsidethehouseisnottechnicallyexhaustive.Thefireplaceinspectionisvisual anddoesnotincludetheinterioroffluesorchimneys,draftcharacteristics,chimneyorfireboxintegrityorthe adequacyofdraft,orairflow.Consultwithareputablechimneyandfireplaceprofessionalifafullevaluationis desired.Forsafetyreasons,afireplaceandthechimneyorpipetowhichitisventedshouldbecleanedand checkedagainforanyvisibleconcerns.Theconditionsofthefireplace(s)foundinthehomeareasfollows: Thegasfireplace(s)werevisuallyinspectedandoperatedifpossible.Manyoftheseunitsarecontrolledbya wallmountedswitch.Someoperatebyremotecontrol,whileothersarecontrolledfromthebaseoftheunit. Theseunitsusuallycomewithaninstructionplatethatisattachedtotheunitinsidethecontrolaccesspanel. Besuretoreadandunderstandtheoperatingprocedurespriortooperatingtheunit.HomeTeamdoesnot lightanypilotlightsduringinspection.Therewerenoconcernsobservedonthegasfireplace. Page12of20 FileNumber:655439 AddressofInspection:123MainSt BATHROOMS Thebathroom(s)ofthehomewereinspectedforfunctionalflowanddrainage,presenceofhot/coldwater, installationofpiping/fixtures,andvisibleleaks.Thisreportisnotintendedtobeanexhaustivelistofminor plumbingissues.Concealed,latent,orintermittentplumbingissuesmaynotbeapparentduringthetesting period. Thebathroom(s)wereexhaustedbyfan. Therewereissuesofconcerninthebathroom(s). Unsealedareasatbathsurroundsinthemasterandupstairsbathrooms.Thisisawaterpenetration/ substratedamageconcern.Recommendrepairsbyqualifiedperson. Upstairsbathroomsurrounds Masterbathroomshowersurrounds Observedlooseshowerstemsintheupstairsanddownstairshallwaybathrooms.Thisisamovement concern.Recommendrepairsbyaqualifiedperson. Downstairshallwaybathroomshowerstem Upstairsbathroomshowerstem Thejettedtubwastestedbyfillingthetubabovethejetsandengagingtheon/offswitch.Theoperationofthe tubwasdonebyverifyingthatwaterwascomingoutofeachofthejets.Toollesspanelsareremovedwhen possibletoinspectunderneathtub.Panelsrequiringtoolswerenotremovedduringinspection.Therewere concernsobservedwiththejettedtub. Gapobservedbetweenbottomofjettedtubandsubfloor.Thisisasupport/damageconcern. Recommendrepairsbyaqualifiedcontractor. Page13of20 FileNumber:655439 AddressofInspection:123MainSt Jettedtub-masterbathroom WATERHEATER Therewasa50galloncapacity,naturalgaswaterheaterlocatedinthegarage.Thewaterheaterwas manufacturedbyA.O.Smith,andappearedtobemanufacturedin2006.Clientshouldnotethatwater temperaturegreaterthan120degreespresentsascalding/burnconcern. Atemperatureandpressurereliefvalve(TPRV)isnottestedaspartofastandardhomeinspectionas leakagefromvalvecanoccurfromtesting. Therewereconcernsobservedwiththehotwaterheater. Waterheaterexhaustventiscontactingcombustiblesnearunit.Thereistypicallya1inchgapto combustiblestominimizesafety/damageconcerns.Recommendrepairs. Contactingcombustibles Page14of20 FileNumber:655439 AddressofInspection:123MainSt ELECTRICALSYSTEM Inspectionoftheelectricalsystemofthehouseincludes:serviceentranceconductorsandequipment, groundingequipment,mainanddistributionpanels,amperageandvoltageratingsoftheservice,branch circuitconductorsandcompatibilityoftheirampacities,operationofarepresentativenumberoflighting fixtures/switches/outletsinsidehouse,garage,andexteriorwalls,polarityandgroundingofallreceptacles within6feetofplumbingfixtures,operationofGFCIdevices,andpresenceofsmokeandcarbonmonoxide detectors. Theundergroundelectricservicewireenteredoutsideofthehomeontherightsidewall.Theservice entrancecableconsistedofstrandedcopperwithanestimatedamperageof200amps.Typicalgrounding methodswherevisible.Groundingwires/rodsareconcealedandnotvisibleinareas. Themainservicepanelislocatedonthegaragewallwitha200ampand110/220voltratedcapacity.The mainservicedisconnectswitchwaslocatedinthemainpanel.The110vbranchcircuitswithinthepanelwere copper.The220vbranchcircuitswerecopper.Thesebranchcircuitswereattachedtobreakers.Therewere noconcernsobservedwithinthemainpanel. Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthehome weretested.Thegroundingandpolarityofreceptacleswithinsixfeetofplumbingfixtures,andthoseattached togroundfaultcircuitinterrupters(GFCI),ifpresent,werealsotested.Ifhouseisoccupied,outsideand garageoutletsmaynotbetestedforGFCIprotectionastheresetmaybeconcealedbystorageand belongings.TheinstallationofGFCIprotectedcircuitsand/oroutletslocatedwithinsixfeetofwater,in unfinishedbasementareas,garageandtheexteriorofthehomeisacommonlyacceptedpracticeand requiredbymanymunicipalities.AllGFCIreceptaclesandGFCIcircuitbreakersshouldbetestedmonthly. Therewereconcernsobservedwiththelightingfixtures,switches,and/orreceptacles. Openjunctionboxobservedatbutnotlimitedtotherearleftofcrawlspace.Thisisadamage/shock concern.Recommendrepairsbyaqualifiedperson. Openjunctionbox-Crawlspace Page15of20 FileNumber:655439 AddressofInspection:123MainSt SMOKE/CARBONMONOXIDEDETECTORS Allsmokeandcarbonmonoxidedetectorsfoundinhouseweretestedduringtheinspection.Forsafety reasons,thealarmsshouldbetestedagainuponoccupancy.Thebatteriesshouldbereplacedwithnewones whenyoumoveintothehouse,andtestedonamonthlybasisthereafter.Detectorstiedintosecuritysystems arenottestedduringthehomeinspection.Therewerenoconcernsfoundinthesmokeand/orcarbon monoxidedetectorsinthehouse. PLUMBING ThevisiblewatersupplylineintothehomewasPVC.ThevisiblewaterlinesthroughoutthehomewerePEX. Watervalvesarenottestedaspartofthehomeinspection.Watervalvesthathavenotbeenoperatedforan extendedperiodoftimeoftenleakafterbeingoperated.Wewouldnotbeabletorepairaleakingvalveduring thehomeinspection.Therewereconcernsobservedintheplumbingsupplyanddistribution. Waterlinesinareasatbutnotlimitedtothecenterofthecrawlspacearenotfullysupported.Thisis amovement/damageconcern.Recommendrepairsbyqualifiedperson. Waterlinenotfullysupported ThevisiblewastelinesthroughoutthehomewerePVC.Someareasofthewasteplumbingmaynothave beenvisibleduringtheinspection.Therewereconcernsobservedintheplumbingwaste,drain,and/orvent systems. 1. Staining/elevatedmoistureunderneathmasterbathstallshower.Thisisaleakage/substrate damageconcern. 2. Leakingobservedaroundmasterbathjettedtubintothecrawlspace.Thisisa leakage/substratedamageconcern. Recommendevaluationandrepairsasdirectedbyqualifiedcontractor. Page16of20 FileNumber:655439 AddressofInspection:123MainSt Staining/elevatedmoisture-Stallshower Leaking-Jettedtub Themainwatershutoffvalveforthehomewaslocatedinthecrawlspace.Watershutoffvalvesarevisually inspectedonly.Noattemptismadetooperatethemainoranyotherwatersupplyshutoffvalvesduringthe inspection.Thesevalvesareinfrequentlyusedandcouldleakafterbeingoperated.Thisisforyour information. Watershutoff-Crawlspace GASMETER Thegasmeterwaslocatedintheleftsideyard.Themaingasvalveisusuallylocatedatthegasmeterand requiresawrenchtooperate. Page17of20 FileNumber:655439 AddressofInspection:123MainSt FOUNDATION Thehousewasbuiltonacrawlspacestylefoundation.Conditionsofthefoundationareasfollows: CRAWLSPACE Theinspectorenteredthecrawlspaceattheaccesspoint.Crawlspacewasvisuallyinspectedwitha flashlight,probe,moisturemeter,andcamerainallaccessibleareas.AreasaroundHVACunitsandductwork aregenerallynotvisible/accessibleduringtheinspection.Thecrawlspacewasaccessible.Inareasthatwere notaccessible,inspectorviewedasbesthecouldfromadistancewithaflashlight. Avaporretarderisinstalled.Crawlspacewasinsulatedwithblanket/battinsulation.Therewereconcerns observednotedinthecrawlspace. Moisturelevelswerecheckedduringtheinspectionusingamoisturemeter.Highmoisturelevelscan generateconditionsthatareidealforwooddestroyinginsects,fungallikegrowth,andwooddamage/rot. Clientshouldnotethatmoisturelevelscouldbehighonedayanddrythenextasconditionschange throughouttheyear.Clientmaywishtotakemeasurestoensurefoundationareasareasdryaspossible. Therewereconcernsobservedwiththemoistureinthefoundation. 1. Stainingonfoundationwall,andaroundventopeningsatareasaroundthehouse.Thisisa waterpenetration/adversemoistureconcern. 2. Foundationventshavebeenblocked/coveredupattherightandrearofhouse.Thismaynot allowforproperairflow/ventilation. Recommendrepairsasnecessarybyqualifiedperson. Blockedvent FLOORSTRUCTURE Thefloorstructurewasvisiblefromcrawlspace.Flooringwassupportedbydimensionallumberontopof foundationwallandpiersconstructedofbrickandconcrete.Therewerenoconcernsobservedinthevisible portionsoftheflooringand/orthesupports. Page18of20 FileNumber:655439 AddressofInspection:123MainSt HVACSYSTEM TheHVACsystemwasevaluatedbyAirTreatment.Heatandairconditioningweredistributedthroughthe homebyductsystem.Evaluationoftheoperationsoftheunit(s)wasperformedbyAirTreatmentInc..Please refertotheirreportforanyconcernsobservedwiththesystem(s). Page19of20 FileNumber:655439 AddressofInspection:123MainSt REASONABLEEXPECTATIONSREGARDINGAPROFESSIONALHOMEINSPECTION: Theremaycomeatimewhenyoudiscoversomethingwrongwiththehouse,andyoumaybeupsetordisappointedwithyourhomeinspection. Therearesomethingswe'dlikeyoutokeepinmind. Intermittentorconcealedproblems:Someproblemscanonlybediscoveredbylivinginahouse.Theycannotbediscoveredduringthefew hoursofahomeinspection.Forexample,someshowerstallsleakwhenpeopleareintheshower,butdonotleakwhenyousimplyturnonthe tap.Someroofsandbasementsonlyleakwhenspecificconditionsexist.Someproblemswillonlybediscoveredwhencarpetsarelifted, furnitureismovedorfinishesareremoved. Noclues:Theseproblemsmayhaveexistedatthetimeoftheinspection,buttherewerenocluesastotheirexistence.Ourinspectionsare basedonthepastperformanceofthehouse.Iftherearenocluesofapastproblem,itisunfairtoassumeweshouldforeseeafutureproblem. Wealwaysmisssomeminorthings:Somesayweareinconsistentbecauseourreportsidentifysomeminorproblemsbutnotothers.The minorproblemsthatareidentifiedwerediscoveredwhilelookingformoresignificantproblems.Wenotethemsimplyasacourtesy.Theintentof theinspectionisnottofindthe$200problems;itistofindthe$1000problems.Thesearethethingsthataffectpeople'sdecisionstopurchase. Contractor'sadvice:Acommonsourceofdissatisfactionwithhomeinspectorscomesfromcommentsmadebycontractors.Contractors' opinionsoftendifferfromours.Don'tbesurprisedwhenthreeroofersallsaytheroofneedsreplacement,whenwesaidthattheroofwouldlast afewmoreyearswithsomeminorrepairs. "Lastmanin"theory:Whileouradvicerepresentsthemostprudentthingtodo,manycontractorsarereluctanttoundertaketheserepairs. Thisisbecauseofthe"lastmanin"theory.Thecontractorfearsthatifheisthelastpersontoworkontheroof,hewillgetblamediftheroof leaks,regardlessofwhetherornottheroofleakishisfault.Consequently,hewon'twanttodoaminorrepairwithhighliability,whenhecould re-rooftheentirehouseformoremoneyandreducethelikelihoodofacallback.Thisisunderstandable. Mostrecentadviceisbest:Thereismoretothe"lastmanin"theory.Itsuggeststhatitishumannatureforhomeownerstobelievethelastbit ofexpertadvicetheyreceive,evenifitiscontrarytopreviousadvice.Ashomeinspectors,weunfortunatelyfindourselvesinthepositionof "firstmanin"andconsequentlyitisouradvicethatisoftendisbelieved. Whydidn'tweseeit?:Contractorsmaysay,"Ican'tbelieveyouhadthishouseinspected,andtheydidn'tfindthisproblem." Thereareseveralreasonsfortheseapparentoversights: Conditionsduringinspection:Itisdifficultforhomeownerstorememberthecircumstancesinthehouseatthetimeoftheinspection. Homeownersseldomrememberthatitwassnowing,therewasstorageeverywhereorthatthefurnacecouldnotbeturnedonbecause theairconditioningwasoperating,etc.It'simpossibleforcontractorstoknowwhatthecircumstanceswerewhentheinspectionwas performed. Thiswisdomofhindsight:Whentheproblemmanifestsitself,itisveryeasytohave20/20hindsight.Anybodycansaythatthe basementiswetwhenthereis2"ofwateronthefloor.Predictingtheproblemisadifferentstory. Alonglook;Ifwespenthalfanhourunderthekitchensinkor45minutesdisassemblingthefurnace,we'dfindmoreproblems,too. Unfortunately,theinspectionwouldtakeseveraldaysandwouldcostconsiderablymore. We'regeneralists:Wearegeneralists;wearenotspecialists.Theheatingcontractormayindeedhavemoreheatingexpertisethanwe do.Thisisbecauseweareexpectedtohaveheatingexpertiseandplumbingexpertise,structuralexpertise,electricalexpertise,etc. Aninvasivelook:Problemsoftenbecomeapparentwhencarpetsorplasterareremoved,whenfixturesorcabinetsarepulledout,and soon.Ahomeinspectionisavisualexamination.Wedon'tperforminvasiveordestructivetests. Notinsurance:Inconclusion,ahomeinspectionisdesignedtobetteryourodds.Itisnotdesignedtoeliminateallrisk.Forthatreason,ahome inspectionshouldnotbeconsideredaninsurancepolicy.Thepremiumthataninsurancecompanywouldhavetochargeforapolicywithno deductible,nolimitandanindefinitepolicyperiodwouldbeconsiderablymorethanthefeewecharge.Itwouldalsonotincludethevalueadded bytheinspection. ReprintedfromASHIReporter,ByPermissionofAlanCarson,CarsonDunlop&Assoc. Page20of20
© Copyright 2026 Paperzz