home inspection report Home. Safe. Home. Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home inspection is to visually examine the readily accessible systems and components of the home. The inspectors are not required to move personal property, materials or any other objects that may impede access or limit visibility. Items that are unsafe or not functioning, in the opinion of the inspector, will be described in accordance with the standards of practice by which inspectors abide. What does this report mean to you? This inspection report is not intended as a guarantee, warranty or an insurance policy. Because your home is one of the largest investments you will ever make, use the information provided in this report and discuss the findings with your real estate agent and family to understand the current condition of the home. Our inspections exceed the highest industry standards. FAST Because we use a team of inspectors, each an expert in his or her field, our inspections are performed with greater efficiency and more expertise and therefore exceed the highest industry standards. We are pleased to provide this detailed report as a service to you, our client. TRUSTED We believe in your dream of home ownership. We want to help you get into your dream home. Therefore, we take great pride in assisting you with this decision making process. This is certainly a major achievement in your life. We are happy to be part of this important occasion and we appreciate the opportunity to help you realize your dream. We exceed your expectations. Buying your new home is a major decision. Much hinges on the current condition of the home you have chosen. That is why we have developed the HomeTeam Inspection Report. Backed by HomeTeam’s experience with hundreds of thousands of home inspections over the years, the report in your hand has been uniquely designed to meet and exceed the expectations of today’s homebuyers. We are proud to deliver this high-quality document for your peace of mind. If you have any questions while reviewing this report, please contact us immediately. Thank you for allowing us the opportunity to serve you. ACCURATE Summary ThisInspectionSummaryisprovidedasaconveniencetoourclient.Thesummarybelowhighlightssignificant elementsoftheInspectionrecentlyperformedbyTheHomeTeam.Itdoesnotsubstituteforathoroughreadingofthe narrativereportthatfollows.HomeTeamrecommendsthatprofessionalbidsbeobtainedfromlicensedcontractorsto determineand/orconfirmcostsofrepairsorcorrectionspriortoclosing. FOUNDATION&STRUCTURALSYSTEMS Oneofthesteelsupportpostsappearstohavebeenremovedandisleaningagainstthe foundationwall.Thisshouldbereplaced. PLUMBINGSYTEMS Aminorleakwasdrippingatthefirstfloorhallceilingleadingoutofthehearthroom.Thisis directlybelowanupperlevelbathroom.Itindicatesalikelydrainleakwhichisinneedoffurther evaluationandrepair. Aminordripwasnotedinadrainlineinthebasementceilingjustbehindthestairs.Minor repairsareneeded ELECTRICAL Tworeceptacleslocatedjustinsidetherecroomabovetherightgarageindicatednovoltage presentwhenwetestedthem.Evaluationandrepairisneededtorestorevoltage. INTERIORELEMENTS Thebasementstairwellwasnotequippedwithahandrail.Ahandrailisanimportantsafetyitem thatmighthelppreventinjuryandmayhelptopreventafalldownthestairs.Ahandrailshould beinstalled. Page1of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt INSPECTIONTEAM MaurieBlick-KSReg#0110-0038-HomeTeammasterinspectorisalsoalicensedelectrician JustinBlick-KSReg#0611-0212-HomeTeammasterinspectorisalsoalicensedelectrician GourmetHeatingandAir-OwnerWayneZeller785-966-2112(Mayetta) OVERVIEW Throughoutthisreport,theterms"right"and"left"areusedtodescribethehomeasviewedfacingthefront elevationofthehome.Theterm"majorvisualdefect"isdefinedintheHomeInspectionAgreement,theterms ofwhichareincorporatedintothisreport.TheHomeTeaminspectsforevidenceofmajorvisualdefectsand safetyconcernsonly.Thecosmeticconditionsofthepaint,wallcovering,carpeting,windowcoverings,etc., arenotaddressed.Allconditionsarereportedastheyexistedatthetimeoftheinspection.Routine maintenanceandsafetyitemsarenotwithinthescopeofthisinspectionunlesstheyotherwiseconstitute major,visuallyobservabledefectsasdefinedintheHomeInspectionAgreement.Althoughsome maintenanceand/orsafetyitemsmaybedisclosed,thisreportdoesnotincludeallmaintenanceorsafety items,andshouldnotberelieduponforsuchitems. NON-OCCUPIEDDWELLINGS:Structuresthathavenotbeenoccupiedforaperiodoftimemaypresent uniqueproblemswhentheyarere-occupied.Somestructuralandmechanicalcomponentsandsystemsthat havenotbeenusedonadailybasismaymalfunctionorpresentmaintenanceissuessoonafterbeingplaced backintodailyservice.Plumbingsystemswillquiteoftenpresentmaintenanceissueswhenthesystemsare returnedtoregularuse.Leaksmaydevelop;usuallyminorinnatureatfaucetsandothersupplyconnections andatdrainfittingswhichcanbecausedbyexcesssedimentsettlinginsupplylinesandbysealsand washersdryingoutinvalvesanddrainfittings.Althoughsomewhatrare,sewerlinescanbecomeobstructed andbackupseveraldaysafterthehomeisre-occupied.Sedimentthathardensinsideasewerpipethathas beendryforanextendedperiodoftimecanbreaklooseandclogtheline.Thisisusuallyremediedbyroutine sewerauguringservice. GENERALDESCRIPTION Theinspectedpropertyconsistedofaoneandahalfstorywood-framedstructurewithhardcoatstucco exteriorandstoneveneerthatwasvacantatthetimeoftheinspection.Theestimateddateofconstruction, asreportedbythesellerwassaidtobe2007. Minorabrasionsandhairlinecracksseeninthestuccoareinneedofmaintenanceattentiontosealthem againstmoistureinfiltration. Pipeandutilitypenetrationsoftheexteriorareinneedofmaintenanceattentiontocaulkandsealthemto preventmoistureinfiltration;especiallyattheACcondensingunits. Page2of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Itshouldbenotedthatthebrickorstoneveneerisinstalledinfrontofthewoodframeorcuredconcrete structureofthewall.Thewallstructuredoesnotrelyonthebrickforstoneworkforitsstructuralintegrity.Any cracksinthemasonryshouldbemonitoredforindicationsofsignificantsettlingorshiftingandanycracksor gapsinthemasonryormortarshouldbesealedagainstmoistureinfiltration. Thehomewassituatedonalightlyslopedlot.Thegeneralgradeoftheterrainappearedtobefunctionalto directrainwaterawayfromthefoundation.Gradinganddrainageproblemsmaybedifficulttodetermine duringdryweather.Ifwaterpoolingisnoticedduringorimmediatelyfollowingperiodsofrainfall,routinehome owner'smaintenancewouldbeindicatedtoaddsoilorreshapethecontourofthegradetoeliminateany pooling.Waterpoolingnexttothefoundationofthehomecancauseleakingormayevendamagethe foundationovertime. Itisrecommendedthategresswindowwellsbeprovidedwithacoversufficienttokeeppersonnelorcritters fromfallingin. Minordepressionsseeninafewlocationsaroundtheperimeterofthehomeareinneedofsomeadditional filltopreventpoolingatthoselocations. Page3of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Theapproximatetemperatureatthetimeoftheinspectionwas20-25degreesFahrenheit,andtheweather wassunnyandclear.Theutilitieswereonatthetimeoftheinspection.Thebuyersandtheiragentarrivedto observetheinspectionafteritwasinprogress. Therewasaconcretewalkwayleadingtoaconcreteporchinthefrontofthehome.Therewerenomajor visualdefectsobservedinthewalkwayortheporch. Therewasaconcretedrivewayinthefrontofthehomewhichledtothegarage.Therewerenomajorvisual defectsobservedinthedriveway. GARAGE Thefrontgaragewasdesignedfortwocarswithaccessprovidedbytwooverhead-styledoors.Bothofthe OverheadDoorbrandelectricgaragedooropenersweretestedandfoundtobefunctional.Theautomatic safetyreverseonthegaragedoorswastestedandfoundtobefunctional.Theconcretegaragefloorwasin functionalcondition.Therewerenomajorvisualdefectsobservedinthegarageorthedoormechanisms. Thereargaragewasdesignedforonecarwithaccessprovidedbytwooverhead-styledoors.Bothofthe OverheadDoorbrandelectricgaragedooropenersweretestedandfoundtobefunctional.Theautomatic safetyreverseonthegaragedoorswastestedandfoundtobefunctional.Theconcretegaragefloorwasin functionalcondition.Therewerenomajorvisualdefectsobservedinthegarageorthedoormechanisms. PATIO Therewasaconcretepatiolocatedinthebackofthehome.Therewerenomajorvisualdefectsobservedon thepatio. ROOFSTRUCTURE Theroofwasagable,hipandvalleydesigncoveredwithimpactresistantarchitecturalgradeasphaltfiberglassshingles.Observationoftheroofsurfaces,flashingandpenetrationsthroughtheroofwas performedfromeaveslevelwiththeaidofbinoculars.Theageoftheroofcoveringwasunknown.Therewas onelayerofshinglesontheroofatthetimeoftheinspection.Therewasnocurlingorcuppingandlight surfacewearobservedontheroofshinglesatthetimeoftheinspection.Theseconditionsindicatetheroof shingleswereinthefirstthirdoftheirusefullife. Roofventilationwasseentobeprovidedbygable,soffitandridgevents.Theroofdrainagesystemconsistedof aluminum guttersanddownspoutswhichappearedtobefunctionalatthetimeoftheinspection.Guttersand downspoutsshouldreceiveroutinemaintenancetopreventprematurefailure.Therewerenomajorvisualdefects observedonthevisibleportionsoftheguttersordownspouts. Itisrecommendedthatsplashblocksandorextendersbeprovidedbeneaththedownspoutsofthegutter system.Thesplashblocksandextendersservetopreventsoilfromwashingawayandcreatingdepressions inwhichwatercanpool.Thedischargepipeforthesumppumphasdugasignificantdepressionwhichneeds fillingandshouldbeprovedwithasplashblockandorextender. Page4of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Therewasonechimney.Observationofthechimneyexteriorwasmadefromtheeaves.Therewerenomajor visualdefectsobservedontheexterior. Thisvisualroofinspectionisnotintendedasawarrantyoranestimateontheremaininglifeoftheroof. Sometimesouropinionofaroofmaydifferfromthatofaninsuranceunderwriter.Weapplyawidely recognizedinspectionstandardwhichisdefinedbytheAmericanSocietyofHomeInspectors.Thestandards ofinspectionappliedbyinsuranceunderwriterscanvarywidelyfromcompanytocompanyorevenfrom adjustertoadjuster.Someinsuranceprovidersaremoreparticularthanotherswhenitcomestoevaluating andinsuringaroof.Westrivetoprovideaclear,accurateevaluationofcurrentconditionsbaseduponwell established,consistentstandardsofourindustry. FOUNDATION Thefoundationwasconstructedofpouredconcrete.Sometypicalsettlementcrackingwasobserved.Asingle inspectioncannotdeterminewhethermovementorsettlingofafoundationhasceased.Anycracksshouldbe monitoredregularly.Therewerenomajorvisualdefectsobservedonthevisibleportionsofthefoundation. BASEMENT Thefullbasementwasunfinished,andcontainedthefollowingmechanicalsystems:furnace,waterheater, sumppumpandsewageliftpump.Thebasementstairsdidnothaveahandrail. Thebasementwasdryatthetimeoftheinspection.Becausethebasementisbelowgrade,thereexistsa vulnerabilitytomoisturepenetrationafterheavyrains. Thebasementstairwellwasnotequippedwithahandrail.Ahandrailisanimportantsafetyitemthat mighthelppreventinjuryandmayhelptopreventafalldownthestairs.Ahandrailshouldbe installed. Severalhairlinecrackswereobservedinthebasementfloorslabandwereinspectedforevidenceof significantsettling,shiftingormoistureinfiltration.Thesewerenotconsideredtobestructurallysignificantat thetimeoftheinspectionbutshouldbemonitored. Page5of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt FLOORSTRUCTURE Thevisiblefloorstructureconsistedofawaferboardsub-floor,supportedbytwobytwelveinchTJIjoists spacedsixteeninchesoncenter.Therewasa6x10inchsteelcenterbeamandthreeinchsteelpostsorpiers forloadbearingsupport.Therewerenomajorvisualdefectsobservedinthevisibleportionsofthefloor structure.Oneofthesteelsupportpostsappearstohavebeenremovedandisleaningagainstthe foundationwall.Thisshouldbereplaced.Oneormoreoftheothersupportpostsmayhavebeen relocated.Wesawnoevidenceofanystructuraldeflectionorshifting. PLUMBING ThevisiblewatersupplylinesthroughoutthehomeweretypePEXPolyethylenetubingandsomecopper Pipe.Thewaterwassuppliedbyapublicsystem.ThevisiblewastelinesconsistedofPVCpipe.Thehome wasconnectedtoaseptictanksystem. Waterpressurewastestedatanoutdoorhydrantandfoundtobe50-60poundspersquareinch.Therewere nomajorvisualdefectsobservedinthevisibleportionsoftheplumbingsystem. Themainshutoffvalveforwaterwaslocatednearthepointofentryintothehomeinthebasement. Aminorleakwasdrippingatthefirstfloorhallceilingleadingoutofthehearthroom.Thisisdirectly belowanupperlevelbathroom.Itindicatesalikelydrainleakwhichisinneedoffurtherevaluation andrepair. Aminordripwasnotedinadrainlineinthebasementceilingjustbehindthestairs.Minorrepairsare needed. PVCpipesstubbedupthroughthebasementfloorareintendedfortheinstallationofplumbingfixturesfora futurebath.Typically,theselinesaretiedintotheactivedrainsystematthetimeofconstruction.Inthiscase, itislikelythatthedrainpipesaretiedintothenearbysewageliftstation. Page6of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Allplumbingfixturesnotpermanentlyattachedtoahouseholdappliancewereoperatedandinspectedfor visibleleaks. Thekitchenplumbingwasinspected.Therewerenoleaksobservedinthevisiblepipingandconnections. Waterflowateachofthefixtureswasadequate.Drainflowwasadequate. Themasterbedroomwetbarwasinspected.Therewerenoleaksobservedinthevisiblepipingand connections.Waterflowateachofthefixtureswasadequate.Drainflowwasadequate. Thelaundryroomutilitysinkwasinspected.Therewerenoleaksobservedinthevisiblepipingand connections.Waterflowateachofthefixtureswasadequate.Drainflowwasadequate. Theplumbinginallofthebathroomswereinspected.Faucetswerecheckedforadequateflowandfor leakage.Thedrainswerefloodedtocheckdrainflow.Accessiblesupplyanddrainconnectionswerechecked forleaksorexcesscorrosion.Exhaustfanswerecheckedtodetermineiftheywerefunctionalinany bathroominwhichtheywerelocated.Wefoundtheventilation,fixturesanddrainsinthebathroomsin functionalconditionwiththefollowingexceptions. Thesinkdrainsinthefirstfloorhalfbath,bothoftheupperbathroomsandbothofthemasterbathsinksare slowflowing.Theyshouldbemonitoredandmayrequiresomedraincleaningoradjustmentgoingforward. Theupperrearbathsinkfaucetislooseandinneedofsometighteningoradjustment. Therewasasumppumplocatedinthebasement.Thesumppumpwasfunctional. Propanestoragetanksmaybeprivatelyownedorownedandmaintainedbyprivatecompanies.Throughout thisreport,thewordsnaturalgasandgasshallbeunderstoodtomeanpropaneifpropaneisbeingusedfor thestructure.Werecommendconsultingwiththesellerconcerningownershipofthetankandtorequest copiesofavailabledocumentationrelatingtotheoperation,servicehistoryandmaintenancerequirementsof thesystem. Page7of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Thishomeisequippedwithapassiveradonreductionsystem.Thesesystemsareusuallyinstalledatthetime oforiginalconstructiontopreventabuildupofradongaswithinthehome.TheygenerallyuseaPVCpipe systemtoestablishaventpathfrombeneaththeconcreteslabofthebasementtotheexteriorofthehome. Thepipesystemcreatesapathwayforthemigrationofanyradongasthatmayaccumulatebeneaththe hometotheexterior.Radongasisanodorlessradioactivegasthatoccursnaturallyasaresultofthedecay ofuraniuminthesoil.MostpassiveRadonreductionsystemscanbeupgradedtoanactivesystemifneeded byaddinganinlinelowflowexhaustfantothesystem. Thereweretwowatersoftenerslocatedinthebasement.Theydidappeartobeinservice.Thewater softenerisnotwithinthescopeofourinspection.Thesellershouldbeconsultedastotheconditionandthe operationofthewatersoftenerandwhetheritwillstaywiththehome.Ifitwillstay,thebuyershouldbe providedwithanyavailabledocumentationregardingtheoperation,care,andmaintenanceofthesystem alongwithanyservicehistoryorwarrantyinformationthatmaybeavailable. WATERHEATER Therewas55galloncapacity,electricwaterheaterlocatedatthenorthendinthebasement.Thewater heaterwasmanufacturedbyKenmore;modelnumber153321543andserialnumberJ07A102434. Informationonthewaterheaterindicatedthatitwasmanufacturedin2007.Atemperatureandpressurerelief valve(T&P)waspresent.Becauseofthelimebuild-uptypicalofT&Pvalves,wedonottestthem.Adripleg wasinstalledontheT&Pvalve.Itdidterminateclosetothefloor.Yoursafetydependsonthepresenceofa T&Pvalveandadriplegterminatingclosetothefloor.Thewaterheaterwasfunctional. Therewasan80galloncapacity,electricwaterheaterlocatedatthesouthendinthebasement.Thewater heaterwasmanufacturedbyKenmore;modelnumber153321841andserialnumberG07A028199. Informationonthewaterheaterindicatedthatitwasmanufacturedin2007.Atemperatureandpressurerelief valve(T&P)waspresent.Becauseofthelimebuild-uptypicalofT&Pvalves,wedonottestthem.Adripleg wasinstalledontheT&Pvalve.Itdidterminateclosetothefloor.Yoursafetydependsonthepresenceofa T&Pvalveandadriplegterminatingclosetothefloor.Thewaterheaterwasfunctional. Thewaterheaterisequippedwithanexpansionvalve.Aswaterisheatedwithinthewaterheater,pressureis createdandthewaterexpandsasitwarms.Theexpansionvalveisanadjustablereliefvalvethatwillallow excesspressuretosafelyequalizepressuresthatarecreatedbytheheatingandcoolingcyclesofthehot watersystem. Page8of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt ELECTRICSERVICE Theelectricalserviceequipmentwasinspectedbyalicensedelectrician.Theundergroundelectricservice wireenteredthepropertyontherightside.TheelectricmeterwaslocatedontherightexteriorwallThe servicewireenteredaSiemensweathertightmaindisconnect,locatedontheexteriorwallnearthemeter basewith400ampsofcapacity.Theexteriordisconnectconsistsofapairof200ampmainbreakerssideby sideandnexttothemeter. Theweathertightmaindisconnectsub-feedsaSquareDHomelinebreakertypesub-panellocatedonthe garagewallandanidentical200ampbreakerpanellocatedinthebasementandratedat200ampsof capacityeach. The200ampmainbreakerservicepanellocatedinthebasementsub-feedsaSquareDHomelinebreaker typesub-panellocatedonthebasementwallnexttothe200ampmainpanelandratedat100ampsof capacity. Thebranchcircuitswithinthepanelswerecopper.Thesebranchcircuitsandthecircuitbreakertowhichthey wereattacheddidappeartobeappropriatelymatched.ThevisiblehousewiringconsistedprimarilyofRomex typeandappearedtobeinfunctionalcondition. Page9of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthehome wereinspectedandwerefoundtobefunctional.Thegroundingandpolarityofarepresentativenumberof receptacleswerealsotested.TherewereGFCIprotectedreceptacleslocatedinthekitchen,bathroom, basement,garageandontheexterior.GFCI(GroundFaultCircuitInterrupting)devicesarehighlysensitive safetydevicesthataredesignedtosenseminuteleakagesofcurrentoffofthecircuitpath(toground)and shutoffthepower.Theyaredesignedtopreventelectricalshock.Theyarerecommendedtobeinstalledas receptaclesorbreakerstoprotectoutletslocatedinkitchens,bathrooms,garages,unfinishedbasements, whirlpooltubs,andexteriorreceptacles.ThepresentandtestedGFCItypedeviceswerefunctional.AllGFCI receptaclesandGFCIcircuitbreakersshouldbetestedregularly. Therearetwotimeclockswitchesonthenorthgaragewall.Theseareusedtoturnexteriorlightingonand off.Thetimeclockisadjustabletosettheonandofftimespreferred. Tworeceptacleslocatedjustinsidetherecroomabovetherightgarageindicatednovoltagepresent whenwetestedthem.Evaluationandrepairisneededtorestorevoltage. Theelectricalserviceappearedtobeofsufficientcapacityfortheloadserved.Alarms,electronickeypads, remotecontroldevices,landscapelighting,telephoneandtelevision,andallelectriccompanyequipmentwere beyondthescopeofthisinspection.Therewerenomajorvisualdefectsobservedintheelectricalsystem. SMOKEALARMS Thereweresmokealarmsfoundinthehouse.Thebatteries(ifany)shouldbereplacedwithnewoneswhen youmoveintothehouse,andtestedonaregularbasisthereafter.Thebuilt-intestbutton,whenpresent,only verifiesproperbatteryandhornfunction;itdoesnottestsensingcapabilities.Sensingcapabilitycanbetested usingasimulatedsmoke(aerosol)product.Allormostofthedetectorsdidemitanaudiblesignalwhenthe testbuttonwasoperated. WINDOWSANDDOORS Arepresentativenumberofaccessiblewindowsanddoorswereoperatedandfoundtobefunctional.The primarywindowswereconstructedofaluminumcladwood,casementstyle,withinsulatedglass.Theinterior doorswereoperatedandfoundtobefunctionalwithafewinneedofminoradjustment.Thedoortothe basementisrubbingagainstthetilefloorandinneedofsomeminoradjustment.Allexteriordoorswere operatedandfoundtobefunctional.Theexteriordoorlocksshouldbechangedorre-keyeduponoccupancy. Possibleproblemareasmaynotbeidentifiedifthewindowsordoorshavebeenrecentlypainted.Therewere nomajordefectsobservedinthewindowsordoors. Page10of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt INTERIORELEMENTS TheHomeTeaminspectsforevidenceofmajorvisibledefectsandsafetyconcernsonly.Thecosmetic conditionsofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed.Therewereno majorvisualdefectsobservedontheinteriorelements. Thevisibleportionofthedryerventwasinspectedandappearedtobefunctionalatthetimeoftheinspection. Theventingappearedtobeadequatetoventthedryertotheexteriorofthehomebuttheventsystemwas nottested. Wallsandceilingswereinspectedforthepresenceofsignificantcrackingandorsettling.Minorcracksare commonlyseenthatarecharacteristicofsettlementandorvibrationtypecrackingthatoccursinwalland ceilingsastheage.Therewerenocracksobservedthatappearedtoindicatesignificantunderlyingstructural issues. Wallsandceilingswereinspectedforthepresenceofsignificantstainsordamagethatcouldbeanindication ofcurrentorpastplumbingorroofleaks.Therewerenostainsordamagethatappearedtoindicatecurrently activeleaking.Waterdamageseenontheceilingofthemasterbedroomshouldbemonitored.Therewasno moisturepresentatthetimeoftheinspectionandduringtestingoftheplumbinganddrainsystems,Itislikely thatthisresultedfromaplumbingleakoroverflowofoneoftheplumbingfixturesthatoccurredinthepast. KITCHEN Thevisibleportionsofthecabinetsandcountertopswereinfunctionalcondition.Theapplianceswereturned ontocheckoperationalfunctiononly.Nowarranty,expressorimplied,isgivenforthecontinuedoperational integrityoftheappliancesortheircomponents.Thekitchencontainedthefollowingappliances: TheGeneralElectricrefrigeratorwasinspectedanddidappeartobefunctional.Thetemperaturesettingand icemaker,ifpresent,arenotwithinthescopeoftheinspection. TheKitchenAidelectricrangewasinspectedanddidappeartobefunctional.Theaccuracyoftheclock, timersandsettingsonovensarenotwithinthescopeofthisinspection. TheTradeWindventedrangehoodwasinspectedanddidappeartobefunctional.Thevisibleportionofthe ventingsystemwasinspectedandwasfunctionalatthetimeoftheinspection.Theexhaustcapacityisnot withinthescopeofthisinspection.Cleaningthefanandfiltermayincreasetheexhaustcapability. TheKitchenAiddishwasherwasobservedthroughashortcycleanddidappeartobefunctional. Atrashcompactorwaspresent.Thistypeofapplianceisbeyondthescopeofourinspectionandwasnot tested.Thesellershouldbeaskedtoprovideanymanualsanddocumentationthatmightbeavailable. Thereweretwobeveragecoolers;onelocatedinthekitchenandoneinthemasterbedroom.Theywere operatedandfoundtobefunctional. BothoftheKenmoredisposalswereinspectedanddidappeartobefunctional.Theefficiencyratingisnot withinthescopeoftheinspection. TheISEinstanthotwaterappliancebeneaththekitchensinkandbeneaththemasterbathwetbarsink dispensesinstanthotwaterthroughasmalltapatthesink.Theyweretestedandwasfoundtobefunctional. Page11of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt FIREPLACE Awood-burningfireplacewaslocatedinthehearthroom.Thedamperdidappeartobefunctional.Therewas nobuildupofcombustionbyproductsobservedinthefireboxand/orchimney.Therewerenocracksobserved inthefirebox. Awood-burningfireplacewaslocatedinthebasement.Thedamperdidappeartobefunctional.Neitherof thewoodburningfireplacesappearstohavebeenusedbefore. GASLOGFIREPLACE Agaslogfireplacewaslocatedinthediningroom.Therewasnosignificantbuildupofcombustionbyproducts observedinthefireboxand/orchimney.Therewerenodefectsobservedinthemetalfirebox. Ourinspectionofthefireplacesandchimneyislimitedtothereadilyvisibleportionsonly.Gasisnotturnedon intheeventofpossibleleaks.Theinnerreachesofafluearerelativelyinaccessible.Forsafeandefficient operationwerecommendregularinspectionsbyaqualifiedfireplaceprofessional. ATTICSTRUCTURE Theatticwasaccessedthroughaascuttleinthe2ndfloorbedroomcloset.Theatticabovethelivingspace wasinsulatedwithloose-fillinsulation,approximately16-20inchesindepth.Theroofstructureconsistedof two-inchbyeightinchwoodraftersspaced24inchesoncenterandOSB(waferboard)sheathing.Becauseof theframingandabsenceofacatwalk,accesswaslimited.Mostatticobservationsaremadefromnearthe accessopening.Someatticsaretraverseddependinguponaccessibilityandnecessity.Therewasno moisturevisibleintheatticspace.Theabsenceofvisibleindicationsofmoistureisnotnecessarilyconclusive evidencethattheroofisfreefromleaks.Theonlywaytobesurearoofdoesnotleakistoinspectthe undersideoftheroofduringaheavyrain.Therewerenomajorvisualdefectsobservedintheatticorroof structure. Page12of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt HVAC-HEAT Theheating,ventilatingandairconditioningsystemswereinspectedbyalicensedtechnician.Theinspector wasatechnicianfromGourmetHeatingandAirCo.Annualmaintenanceoftheheatingandcooling equipmentisessentialforsafeandefficientperformance,whichwillmaximizethesystem'susefullife.The SouthendofthemainlevelofthehomewasheatedbyanArcoaireelectricforcedairfurnace;SerialNumber A073384097,ModelNumberFVM2X4800A1.Informationonthenameplateindicatestheunitwas manufacturedin2007.Theunitwaslocatedinthebasementofthehome.Ithasanapproximatenetheating capacityof15KW.Theheatingsystemwasfoundtobefunctional. TheupperlevelofthehomewasheatedbyanArcoaireelectricforcedairfurnace;SerialNumber A073384088,ModelNumberFVM2X4800A1.Informationonthenameplateindicatestheunitwas manufacturedin2007.Theunitwaslocatedinahallclosetontheupperlevelofthehome.Ithasan approximatenetheatingcapacityof15KW.Theupperlevelheatingsystemwasfoundtobefunctional. ThenorthendofthelowerlivinglevelofthehomewasheatedbyaKenmoreelectricforcedairfurnace; SerialNumberA073384098,ModelNumberFVM2X4800A.Informationonthenameplateindicatestheunit wasmanufacturedin2007.Theunitwaslocatedinthebasementofthehome.Ithasanapproximatenet heatingcapacityof15KW.Thenorthendheatingsystemwasfoundtobefunctional. AIRCONDITIONING ThenorthendlowerlevelelectricoutdoorairconditionercondensingunitwasanArcoaire;SerialNumber E081721533,ModelNumberN2H33OGKB200.Theunitislocatedinthesideyardofthehome.Information foundonthenameplateindicatesthatthisunitwasmanufacturedin2008.Periodicpreventivemaintenanceis recommendedtokeepthisunitingoodworkingcondition.Thisunitisratedat2.5tonsofcoolingandhasan estimatedSEERratingof13. TheupperlevelelectricoutdoorairconditionercondensingunitwasanArcoaire;SerialNumberE081304150, ModelNumberN2H336GKB200.Theunitislocatedinthebackofthehome.Informationfoundonthe nameplateindicatesthatthisunitwasmanufacturedin2008.Periodicpreventivemaintenanceis recommendedtokeepthisunitingoodworkingcondition.Thisunitisratedat2.5tonsofcoolingandhasan estimatedSEERratingof13. Page13of14 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthSt ThesouthendlowerlevelelectricoutdoorairconditionercondensingunitwasanArcoaire;SerialNumber E081721541,ModelNumberN2H33OGKB200.Theunitislocatedinthebackofthehome.Informationfound onthenameplateindicatesthatthisunitwasmanufacturedin2008.Periodicpreventivemaintenanceis recommendedtokeepthisunitingoodworkingcondition.Thisunitisratedat2.5tonsofcoolingandhasan estimatedSEERratingof13. FILTERTYPE TheSpaceGuardModel2200Pleateddisposablefilterateachofthethreefurnacesshouldbereplacedona regularbasistomaintaintheefficiencyofthesystem.Theefficiencyratingisnotwithinthescopeofthis inspection. DUCTWORK Thevisibleportionsoftheductworkwereobservedtobefunctionalandwithoutmajordefects.Thereareno supplyregisterslocatedinthebasement. RADONTESTINPROGRESS Radongasisacolorlessandodorlessgasreleasedintothegroundasaresultofuraniumdecay.This invisiblegascanbehazardoustoyourhealthinanenclosedstructure.Theradontestyourequestedisbeing performedbyastatelicensedradonmeasurementtechnicianfromTheHomeTeam-Certification#KS-MS0100.Thetestingwedorequiresaminimumof48hoursofcontinuousmonitoringwithspecializedradon monitoringandrecordingequipment.Theradoninspectionresultwillbereportedwhenthetestingis complete. Page14of14
© Copyright 2026 Paperzz