Maxum® Advance Plus Upgrade The Maxum edition II from Siemens is the most advanced and cost-effective process gas chromatograph today. Now, the Maxum Advance Plus Upgrade provides users with a simple answer to a difficult question: How can we get the cost-saving benefits of new Maxum technology while preserving our existing chromatograph investment? The Maxum Advance Plus is a field-installable upgrade that brings the powerful, cost-saving benefits of Maxum to older existing Optichrom® Advance gas chromatographs. Product description The Maxum Advance Plus Upgrade is a replacement “door assembly” for Optichrom Advance gas chromatographs. All of the vital system electronics from Maxum are integrated inside this new door. In the field, the older, existing door assembly is removed by unplugging its cables and lifting it off of its hinges. The Maxum Advance Plus then goes in its place and gives the older Optichrom Advance the same capabilities as a new Maxum edition II including the builtin Maxum Maintenance Panel. Software functions of the older unit are easily recreated in the new Maxum software environment using the new built-in Maxum Maintenance Panel and a Maxum Workstation running on a laptop PC. With minimal time, effort and investment, you begin: Maxum Advance Plus saves money The Maxum Advance Plus Upgrade is extremely cost-effective to buy and install. J It costs less than a new spare part for the door assembly it replaces when you return your old door assembly for an invoice credit. J It requires no mechanical or electrical rework so installation is done with routine maintenance and minimal down times. J It connects directly to an existing Advance Data Hiway so it requires no changes to existing output devices or to communication links to a DCS computer J Saving money – immediately and in the future; J Using Maxum features – saving time and labor; J Improving the application – for better performance and improved process control. Product Bulletin www.usa.siemens.com/processanalytics J It replaces most of the old electronics in the Advance GC, eliminating the need to buy increasingly expensive older spare parts in the future. Maxum Advance Plus provides Maxum features With the same features as a new Maxum edition II, the Maxum Advance Plus Upgrade saves money in even more ways, both immediately and in the future. How to purchase Maxum Advance Plus may be purchased by contacting any Siemens chromatograph sales office. The product includes all the electronics necessary to upgrade an older Optichrom Advance chromatograph and connect to an existing Advance Data Hiway. Since Maxum Advance Plus uses the same software as Maxum edition II, it is easy for users who have experience with the newer product to convert the older Optichrom Advance application software to the new Maxum system. Optionally, complete software conversion and field installation and startup services may also be purchased from Siemens. J Calibration is fast and easy. Old and new response factors can be compared on a single screen and updated with a single button push which is much faster than the “two-line display” of the Optichrom analyzer. J EZChrom does automatic peak tracking. When components peaks move as column age, EZChrom adjusts so the Maxum Advance Plus needs less maintenance. J Maxum’s Workstation improves efficiency. It lowers routine maintenance costs and improves system up time with comprehensive screens that display results and chromatogram information quickly – eliminating the slow method of reviewing data one item at a time. J Maxum Advance Plus connects to the high speed Maxum communication network. After the analyzers have been upgraded, it becomes possible to upgrade the network. Then, the workstation can be used remotely from the GC itself. This means many routine maintenance checks can be done without spending valuable time in the field. Technical summary All components are packaged in a metal frame door, hinged and ready for installation on the Installation information front of an Optichrom Advance chromatograph electronics enclosure. The door replaces the existing “Controller Board Assembly” used with the Optichrom. The door has the same height and width as the door being replaced and is approximately 1 in. (2.5 cm) deeper. Power required New power supply and cable are included with the new Maxum Advance Plus door. Ambient conditions -18°C – 50°C (0°F – 122°F); Same ambient conditions as the Optichrom Advance chromatograph being upgraded. Electronics supplied Unit includes: Master System Controller, Maxum Maintenance Panel and Ethernet interface Detectors and applications supported The upgrade of your OPTICHROM gas chromatograph is based upon the equipment being in a good state of repair and operating condition and the application and specific programming currently running on your analyzer. Additional charges may apply if current application is: J Air Monitoring or CEMS related J Multiple Applications J More than 4 streams J Any custom program installed by customer or 3rd party vendor J Communications being utilized other than Data Hiway (this includes any automatic log or event printing, unique alarm or events, communications directly with HCI type communication devices, etc) J Siemens will require the serial and project number for any Advance Optichrom being upgraded for review before purchase order can be accepted. J We can no longer offer Advanced Plus Upgrade kits in four configurations: Flame Photometric Detector assembly and configurations (FPD) PTGC PID Cannot provide kits for any TC3 application I/O, printer and DCS communications supported All Optichrom Advance input and output boards and DCS communication options are supported. Any I/O, Printer Interface or Host Computer Interface boards installed in the backplane of the Optichrom Advance being upgraded are left in place and continue to be used without change. Any I/O, printer or host computer hardware connected to the Advance Data Hiway outside of the analyzer itself may continue to be used without change. Alternatively, all external I/O may be replaced with Maxum equivalent hardware, excluding the HCI-A and certain other computer protocols. Maxum Advance Plus improves application In many cases, Maxum Advance Plus can enable significant improvements to chromatograph applications. J Cycle times may be reduced because EZChrom easily resolves component peaks which are close together. J Effects of shifting ambient temperatures may be completely eliminated by EZChrom, improving repeatability – and process control. J Simulated distillation, air monitoring and programmed temperature applications are improved and simplified by the Maxum software used in Maxum Advance Plus. This software makes complex applications easy to set up and much lower in cost to maintain. J For air monitoring and data logging, Maxum Advance Plus provides full access to Maxum’s Workstation reporting software and historical tools. Network connect: Advance Ethernet 10Base-T copper Communications Utilizes standard 10BaseT twisted pair wiring and standard Ethernet communication protocol. Ethernet 10Base-T Fiber Optic Communications Utilizes 10BaseT fiber optic connections and standard Ethernet communication protocol. Advance Data Hiway Communications Siemens proprietary redundant communication paths. Completely compatible with older Data Hiway installations. Options For more information, please contact: Siemens Industry, Inc. 7101 Hollister Road Houston, TX 77040 Phone: 713-939-7400 Email: [email protected] Services: Software conversion engineering and field service installation and conversion services may be purchased separately. Siemens Industry, Inc. Industry Automation Division 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 [email protected] www.usa.siemens.com/processanalytics Workstation Software: Software package includes: System Manager, Advance EZChrom Builder, MMI Emulator, Datalogger, Backup and Restore, Version Updater, PC Anywhere, Modbus Map Editor, and Downloader. Advanced Plus Retrofit Kit with Syscon 2 will include a Maxum Workstation version 5.0 CD which can be installed with the software key from a registered copy of version 4.2. If the customer does not have a registered copy of version 4.2, then version 5.0 will have to be purchased. Subject to change without prior notice Order No.: PIAFL-00021-0311 All rights reserved Printed in USA © 2011 Siemens Industry, Inc. The information provided in this flyer contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
© Copyright 2026 Paperzz