VERIFY® V24 Challenge Pack Description Literature Related

VERIFY® V24 Challenge Pack
Validated, reliable challenge pack for qualification of V-PRO Low
Temperature Sterilization Systems.
Description
VERIFY ® V24 Challenge Packs provide the challenge you need to be confident in your V-PRO Low Temperature Sterilization
Systems. For use in Qualification of V-PRO® Low Temperature Sterilizers.
HOW VERIFY V24 Challenge Packs Work
Each challenge pack contains a process indicator strip, VERIFY V24 Self Contained Biological Indicator and blue polyurethane
foam sheet.
The indicator strip is a Class 1 Process Indicator as defined in ANSI/AAMI/ISO 11140-1 and provides immediate proof of
processing. A vivid color change from magenta to yellow indicates that exposure to a hydrogen peroxide sterilization cycle has
occurred.
Each self-contained biological indicator is completely self-contained, providing 10 6 colony forming units (CFU) of Geobacillus
stearothermophilus and an ampoule of specifically formulated growth medium with a pH indicator. It is designed to be sealed after
processing, reducing the risk of contamination (and consequent false positives) and evaporation of growth medium.
Following incubation, a vivid color change of the growth media from orange to yellow and/or turbidity gives distinct evidence of
microbial growth. If no microbial growth occurs, the media remains orange and clear (no turbidity).
The challenge pack is placed on the bottom shelf within the empty chamber of the V-PRO Sterilizer. The sterilizer must remove
air from the pack and expose the pack to a sufficient quantity of hydrogen peroxide to overcome the absorption of hydrogen
peroxide from the polyurethane foam sheet and kill the bacterial spore contained within the self-contained biological indicator.
The challenge to sterilization provided by the pack is equivalent to or greater that that achieved by the worst case sterilization load.
WHY VERIFY V24 Challenge Pack?
The easy to use VERIFY V24 Challenge Pack is proven to be more resistant than the worst case sterilizer load giving you
confidence in your sterilizers ability to sterilize your loads.
Fast – 24 hour incubation time
Easy to Read - Orange to yellow color change indicates growth
Tougher challenge than validated sterilization loads – Confidence in the V-PRO Sterilizer's performance
VERIFY V24 Challenge Pack’s validated sterilizers and sterilization cycles
Sterilizers
Sterilization Process
Sterilization Cycles
V-PRO 1 Sterilizer
Vaporized hydrogen peroxide
Default Cycle (Lumen Cycle)
V-PRO 1 PLUS Sterilizer
Vaporized hydrogen peroxide
Non Lumen and Lumen Cycle
V-PRO maX Sterilizer
Vaporized hydrogen peroxide
Non Lumen, Flexible and Lumen Cycles
V-PRO 60 Sterilizer
Vaporized hydrogen peroxide
Non Lumen, Flexible and Lumen Cycles
Literature
Related Products
VAPROX ® HC Sterilant
VAPROX ® HC Sterilant
VERIFY ® HPU Chemical Indicator
VERIFY ® Vaporized VH2O2 Process Indicators Adhesive Labels
Verdoc ® Vaporized VH2O2 Record Card with Process Indicators
VERIFY ® V24 Self Contained Biological Indicator
V-PRO ® Sterilizers
Accessories
An incubator and the VERIFY Self-Contained Biological Indicator HP Activator Set are required for proper use of the VERIFY
Biological Indicator Challenge Pack for VH2O2 Sterilization Processes.
Product Number
Description
Quantity
LCB004
VERIFY™ Self-Contained Biological Indicator HP Activator Set
Each
S3080
VERIFY™ 28 Well Dual Incubator (55-60°C and 35-39°C)
Each
S3082
VERIFY™ 28 Well Dual Incubator (55-60°C)
Each
S3271
VERIFY™ 6 Well Dual Incubator (55-60°C)
Each