QUICKSTART “BASIC” GUIDELINES FOR MODEL 9050 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD Model 9050 is intended for installation only on sliding gates used for vehicles. Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual. Physical Stops MUST be Used to Stop Gate Op Direning ec Sw tion i tch 1O FF. ON 1 2 3 4 5 6 7 8 DO NOT power up and cycle the operator without “Physical Stops” installed to stop the gate in the open and close positions (Chain stops are included with the operator but other physical stops can be used). Damage could occur to the gate and operator. Chain stop’s rubber bumpers face toward operator. They will make contact with the operator housing during the initial automatic open/close limits setting sequence. ain Ch cket Bra ire p g wto keem n i t xis rs fro e e ine ay ts. Us estra es aw g par r ir vin w o m • Operator and Chain MUST be parallel to gate! • Chain bracket MUST align with idler wheels! 11” Chain Adjustment C Solenoid Lock Adjust the chain nuts to tighten the chain. The chain should sag no more than one (1) inch per 10 feet of chain travel. Do not over tighten the chain. 15” Min. g n di un ro e G at ti- Pl Gate Frame Hot Switch 1 - Must OPEN the gate upon initial AC power up and open command. If the open command begins to close the gate, turn AC power off and reverse this switch. (See reverse side) l N. nim i ”M 15 uit nd Co r we Po t AC ndui Co um o c ch -in . 4 / s e 3 ep Us swe h t wi it u nd Warning Signs Permanently mount signs on BOTH sides of the gate area and make sure they are easily visible. Copyright 2016 DoorKing, Inc. All rights reserved. ON 4” ab mini ove mu gro m un d. p Loo 1 2 3 4 5 6 7 8 d l! pa ve te le re e nc T b Co US M ad Thi s det dept e h 21 loc rmin of th ”M al b ed e in con uil by con cre ding soil cret imum te r co con e p eco de dit ad mm s (re ion is end info s an ed) rce d d . ” x2 /8” rs 3 4) cho e( Us ve An lied). e p Sle t sup o (N ON 1O eP 1. Opening Direction 2. ON Auto-Close Timer TIME 3. OFF DELAY 4. OFF 5. OFF 6. OFF 7. OFF 8. OFF 1 23 “Basic” Adjust 1 to 23 sec. 1 2 3 4 5 6 7 8 Chain brackets MUST be mounted the same height as the chain on the idler wheels! Idl e Wh r ee re i Wi estra R ret DANGER HIGH VOLTAGE 115 VAC Connection Center Concrete Pad Op Direning Sw ecti itch on nc 115 VAC Neu Concrete Pad and Conduit Area A Chain nut and chain bolt should not protrude past gate frame. Co 4” 21” Min. ner 10 r ste Ma ink L Chain Bracket DIP-Switches 49 Chain Nut Chain Bolt Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. A 10 n2 tio Op GATE OPERATOR MUST BE PROPERLY GROUNDED!! Conduit Area 49 n tio Op Lo ele osen ctr th oni e 2 c b nu ox ts u to sw nder ing the box up. High Voltage Connection 2.5” B Connect Chain Bracket and Chain to Gate 1 U.S.A. 1” minimum space between the gate and the operator housing. An B 120 S. Glasgow Avenue Inglewood, California 90301 Setting Automatic Limits The operator’s open/close limits DO NOT have to be physically adjusted. Every time the operator is powered up, the first open command will automatically run “2 open/close gate cycles” that will locate and remember the gate’s open and close limit positions. These limit positions are determined by where the physical stops have been installed. It does not matter what position the gate is in before running this sequence. The gate will function normally after this automatic sequence has finished. Note: Auto-close timer should be on before running this sequence. Chassis Ground High Voltage AC Input Wire White - Neutral Black - 115 VAC Hot Green - Chassis Ground Every time the 9050 is powered up, the First open command will automatically run “2 open/close gate cycles” that will locate and remember the gate’s open and close limit positions. See “Automatic Open/Close Limit Adjustment” in Installation/Owner’s manual for more information. Plug-In Loop Detectors B Not included - Refer to the Installation/Owner’s manual AND Loop Information Manual (available from www.dkaccess.com) for more information on loops and plug-in loop detectors. Important Note: DoorKing highly recommends that loops and loop detectors are installed with this slide gate operator. A loop detection system will preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. Radio Receiver C Not included - Refer to a specific Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. See reverse side for wiring. All potential entrapment areas MUST be protected with an external entrapment protection device. At least ONE external entrapment protection device MUST be installed or the operator will NOT function. 9050-066-G-10-16 QUICKSTART “BASIC” GUIDELINES FOR MODEL 9050 - DIP-SWITCH AND WIRING REFERENCE Model 9050 is intended for installation only on sliding gates used for vehicles. Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual. Switch Every time the operator is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions. Function Setting Receiver Description Changes the direction the operator will open/close the gate depending on the different chain configurations. Front 1 Opening direction using OFF setting. Mount Opening direction using ON setting. Center or Opening direction using ON setting. Post Mounts Opening direction using OFF setting. Opens with All Rear All Rear Mounts Left Mounts Right ON setting. Opens with OFF setting. U.S.A. Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate. 24 Volt, 250 mamp. Max. 3-Wire Radio ON 1 2 3 4 5 6 7 8 Note: All standalone, telephone entry and photo sensor devices must use a separate power source. Relay Com 24 Volt Power Com WA R NIN G Relay Com MO SE VIN RI G OU GA Ope S IN TE and rate JU CAN free gate RY CA of only Do OR US peo whe ple or not allo DE E andn gate ope AT rate w chil obs area H Do truc is gate dren tion in pathnot stan . to s. sigh play whi d t in le in gate gate Rea gate d own area is path mov er’s ing.or wal man k thro ual ugh and safe ty inst ruct ions CO NFO AN RM SI/U S L-3 TO CAN CER 25 /CS TIF A C22IED VE .2 TO HIC NO . 247 CLA ULAR SS GA TE MO DEL SER Relay N.O. . 2 ER AT OR HP IAL VO 5338 OP LTS 4-Wire Radio Receiver AM PS MA PH X GAT E LOA Doo 2 Auto-Close Timer 3 Relay 4 Built-In Solenoid Lock 5 and 6 OFF Relay is activated when gate is full open. ON Relay is activated when gate is not closed. OFF Normal Setting. Fail-Safe (Factory Set). Lock engages only when an attempt is made to manually force the gate open. , Ing , CA Fire Box Normal Setting. Gate fully closes. Gate stops short 1” from full close position. Used for a reversing edge device. Gate stops short 2” from full close position. Used for a reversing edge device. Gate stops short 3” from full close position. Used for a reversing edge device. Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect. Filler Post If necessary Key Switch N.C. N.C. Stand-Alone Keypad To Main Terminal #12 Ground (Common) G VE HI CLA GA TE MO DE SER L OP 5338 2 Stand-Alone Card Reader ER AT OR HP IAL VO LTS AM PS MA X GA TE LO AD Doo rKi ng, Inc ., PH AS 60 Ing E Hz lew ood 1 2 3 4 5 6 OPEN Beam STOP CLOSE Beam REVERSE OPEN Edge/Beam REVERSE CLOSE Edge/Beam REVERSE 1 - OPEN Beam (UL 325 Terminal 1) 2 - CLOSE Beam (UL 325 Terminal 2) 3 - OPEN Edge (UL 325 Terminal 3) 4 - CLOSE Edge (UL 325 Terminal 4) , CA (See Installation/Owner’s manual for more information) Two 115 VAC Convenience Outlets Power safety and opening devices that require 115 VAC power. N.O. Com 10 11 12 UL 325 DIP-Switches 1 2 3 UL 325 4 Terminal NC NO SELF TEST Common UL 325 DIP-Switches ON CO NF AN OR SI/ MS UL TO -32 CER 5 N/C TIF SA IED C22 TO .2 NO CU . 247 LA R SS CA Connect ONLY MONITORED Devices 6 7 24 V Power 8 Full Open 9 DIP-switches MUST be turned ON for each device wired to terminal. 1 2 3 4 IMPORTANT: Photo sensors must use Normally Closed (NC) contacts with the beam set for light operate (relay activated when beam is not obstructed). MO SE VING RI OU GA Ope S IN TE and rate JU CAN free gate RY CA of onl Do OR US peo y whe ple or not allo DE E andn gat ope AT rate w chil obs e are H truc a is Do gat dre tion in n to pat not stan e. s. sigh h whi play t d in le in gat gat Rea gat e are e is e pat d own mo h a er’s ving or wal ma . k thro nua l and ugh safe ty inst ruc tion s. Open Beam UL 325 Terminal N.C. N.C. WA RN IN Wall 1 2 3 4 8-OFF 8-ON 8-OFF 8-ON Open Edge Closed Gate Telephone Entry ON 7-OFF 7-OFF 7-ON 7-ON Close Beam 2 3 4 5 1 2 3 4 5 6 7 8 Gate Close Back-Off Position External Entrapment Protection Devices EX ON Normal Setting. Gate fully opens. Gate stops short 1” from full open position. Used for a reversing edge device. Gate stops short 2” from full open position. Used for a reversing edge device. Gate stops short 3” from full open position. Used for a reversing edge device. 1 IMPORTANT: Only 1 monitored Device can be connected to each input. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices. Open Edge Gate Open Back-Off Position 6-OFF 6-ON 6-OFF 6-ON 24 Volt Power Hz lew ood ON Fail-Secure. Lock engages after each cycle. CAUTION: Do not use this setting unless the 2600-862 manual release kit has been installed or damage will occur to operator. 5-OFF 5-OFF 5-ON 5-ON ASE Inc. Close Edge 7 and 8 g, OFF Auto-close timer is OFF. Manual input required to close gate. ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. 60 D rKin 4702-010 DIP-Switches 120 S. Glasgow Avenue Inglewood, California 90301 All potential entrapment areas MUST be protected with an external entrapment protection device. At least ONE external entrapment protection device MUST be installed or the operator will NOT function.
© Copyright 2026 Paperzz