QUICKSTART “BASIC” GUIDELINES FOR MODEL 9050

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9050 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD
Model 9050 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.
Physical Stops MUST be Used to Stop Gate
Op
Direning
ec
Sw tion
i
tch
1O
FF.
ON
1 2 3 4 5 6 7 8
DO NOT power up and cycle the operator without “Physical Stops”
installed to stop the gate in the open and close positions (Chain stops
are included with the operator but other physical stops can be used).
Damage could occur to the gate and operator.
Chain stop’s rubber bumpers face toward operator. They will make
contact with the operator housing during the initial automatic
open/close limits setting sequence.
ain
Ch cket
Bra
ire p
g wto keem
n
i
t
xis rs fro
e e ine ay ts.
Us estra es aw g par
r ir vin
w o
m
• Operator and Chain MUST be
parallel to gate!
• Chain bracket MUST align with
idler wheels!
11”
Chain Adjustment
C
Solenoid
Lock
Adjust the chain nuts to tighten the chain.
The chain should sag no more than one
(1) inch per 10 feet of chain travel.
Do not over tighten the chain.
15”
Min.
g
n
di
un
ro e
G at
ti- Pl
Gate
Frame
Hot
Switch 1 - Must OPEN the gate upon initial AC power
up and open command. If the open command begins
to close the gate, turn AC power off and reverse this
switch. (See reverse side)
l
N.
nim
i
”M
15
uit
nd
Co
r
we
Po t
AC ndui
Co
um
o
c
ch
-in .
4
/
s
e 3 ep
Us swe
h
t
wi
it
u
nd
Warning Signs
Permanently mount signs on BOTH sides of the
gate area and make sure they are easily visible.
Copyright 2016 DoorKing, Inc. All rights reserved.
ON
4”
ab mini
ove mu
gro m
un
d.
p
Loo
1 2 3 4 5 6 7 8
d l!
pa ve
te le
re e
nc T b
Co US
M
ad
Thi
s
det dept
e
h
21
loc rmin of th
”M
al b ed
e
in
con uil by con
cre ding soil cret imum
te r co con e p
eco de dit ad
mm s (re ion is
end info s an
ed) rce d
d
.
”
x2
/8” rs
3
4) cho
e(
Us ve An lied).
e
p
Sle t sup
o
(N
ON
1O
eP
1. Opening Direction
2. ON
Auto-Close Timer
TIME
3. OFF
DELAY
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
1
23
“Basic”
Adjust 1 to 23 sec.
1 2 3 4 5 6 7 8
Chain brackets
MUST be mounted
the same height as
the chain on the
idler wheels!
Idl
e
Wh r
ee
re i
Wi estra
R
ret
DANGER
HIGH VOLTAGE
115 VAC Connection
Center
Concrete Pad
Op
Direning
Sw ecti
itch on
nc
115 VAC
Neu
Concrete Pad and Conduit Area
A
Chain nut and chain bolt
should not protrude
past gate frame.
Co
4”
21” Min.
ner
10
r
ste
Ma ink
L
Chain
Bracket
DIP-Switches
49
Chain
Nut
Chain
Bolt
Tip: It is recommended that a surge suppressor be
installed on the high voltage power lines.
A
10
n2
tio
Op
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
Conduit Area
49
n
tio
Op
Lo
ele osen
ctr th
oni e 2
c b nu
ox ts u
to
sw nder
ing the
box
up.
High Voltage Connection
2.5”
B
Connect Chain
Bracket
and
Chain
to Gate 1
U.S.A.
1” minimum space between the gate and the operator housing.
An
B
120 S. Glasgow Avenue
Inglewood, California 90301
Setting
Automatic Limits
The operator’s open/close limits DO NOT have to
be physically adjusted. Every time the operator
is powered up, the first open command will
automatically run “2 open/close gate cycles”
that will locate and remember the gate’s open
and close limit positions. These limit positions
are determined by where the physical stops have
been installed. It does not matter what position
the gate is in before running this sequence. The
gate will function normally after this automatic
sequence has finished.
Note: Auto-close timer should be
on before running this sequence.
Chassis
Ground
High Voltage
AC Input Wire
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Every time the 9050 is powered up, the First open
command will automatically run “2 open/close gate
cycles” that will locate and remember the gate’s open
and close limit positions. See “Automatic Open/Close
Limit Adjustment” in Installation/Owner’s manual for
more information.
Plug-In Loop Detectors
B Not included - Refer to the Installation/Owner’s
manual AND Loop Information Manual (available from
www.dkaccess.com) for more information on loops
and plug-in loop detectors.
Important Note: DoorKing highly recommends that
loops and loop detectors are installed with this slide
gate operator. A loop detection system will preventing
the gate from automatically opening or closing on a
vehicle when it is in the gate’s path.
Radio Receiver
C Not included - Refer to a specific Radio Receiver
Manual (available from www.dkaccess.com) for
more information on radio receivers and antenna
installation. See reverse side for wiring.
All potential entrapment areas MUST be protected with an external entrapment
protection device. At least ONE external entrapment protection device MUST be
installed or the operator will NOT function.
9050-066-G-10-16
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9050 - DIP-SWITCH AND WIRING REFERENCE
Model 9050 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.
Switch
Every time the operator is powered up, the First open command will automatically run
“Multiple gate cycles” that will locate and remember the gate’s open and close positions.
Function
Setting
Receiver
Description
Changes the direction the operator will open/close the gate depending on the different chain configurations.
Front
1
Opening
direction
using OFF
setting.
Mount
Opening
direction
using ON
setting.
Center or
Opening
direction
using ON
setting.
Post
Mounts
Opening
direction
using OFF
setting.
Opens
with
All Rear
All Rear
Mounts
Left
Mounts
Right
ON
setting.
Opens
with
OFF
setting.
U.S.A.
Important: Controls intended for user activation must be located at least six (6) feet away from any moving part
of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the
controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be
placed at any location in the line-of-sight of the gate.
24 Volt, 250 mamp. Max.
3-Wire Radio
ON
1 2 3 4 5 6 7 8
Note: All standalone, telephone
entry and photo
sensor devices
must use a
separate power
source.
Relay
Com
24 Volt Power Com
WA
R
NIN
G
Relay Com
MO
SE VIN
RI G
OU GA
Ope
S IN TE
and rate
JU CAN
free gate
RY CA
of only
Do
OR US
peo whe
ple
or not allo
DE E
andn gate
ope
AT
rate w chil
obs area
H
Do
truc is
gate dren
tion in
pathnot stan .
to
s. sigh
play
whi d
t
in
le in gate
gate
Rea
gate
d own
area
is path
mov
er’s
ing.or wal
man
k thro
ual
ugh
and
safe
ty
inst
ruct
ions
CO
NFO
AN RM
SI/U S
L-3 TO
CAN CER
25
/CS TIF
A C22IED
VE
.2 TO
HIC
NO
. 247
CLA ULAR
SS
GA
TE
MO
DEL
SER
Relay N.O.
.
2
ER
AT
OR
HP
IAL
VO
5338
OP
LTS
4-Wire
Radio
Receiver
AM
PS
MA
PH
X GAT
E LOA
Doo
2
Auto-Close
Timer
3
Relay
4
Built-In
Solenoid Lock
5 and 6
OFF Relay is activated when gate is full open.
ON Relay is activated when gate is not closed.
OFF Normal Setting. Fail-Safe (Factory Set). Lock engages only when an attempt is
made to manually force the gate open.
, Ing
, CA
Fire Box
Normal Setting. Gate fully closes.
Gate stops short 1” from full close position. Used for a reversing edge device.
Gate stops short 2” from full close position. Used for a reversing edge device.
Gate stops short 3” from full close position. Used for a reversing edge device.
Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect.
Filler Post If necessary
Key Switch
N.C.
N.C.
Stand-Alone
Keypad
To Main Terminal
#12 Ground (Common)
G
VE
HI
CLA
GA
TE
MO
DE
SER
L
OP
5338
2
Stand-Alone
Card Reader
ER
AT
OR
HP
IAL
VO
LTS
AM
PS
MA
X GA
TE
LO
AD
Doo
rKi
ng,
Inc
.,
PH
AS
60
Ing
E
Hz
lew
ood
1
2
3
4
5
6
OPEN Beam STOP
CLOSE Beam REVERSE
OPEN Edge/Beam REVERSE
CLOSE Edge/Beam REVERSE
1 - OPEN Beam (UL 325 Terminal 1)
2 - CLOSE Beam (UL 325 Terminal 2)
3 - OPEN Edge (UL 325 Terminal 3)
4 - CLOSE Edge (UL 325 Terminal 4)
, CA
(See Installation/Owner’s manual for more information)
Two 115 VAC Convenience Outlets
Power safety and opening devices
that require 115 VAC power.
N.O.
Com
10
11
12
UL 325
DIP-Switches
1
2
3 UL 325
4 Terminal
NC
NO
SELF
TEST
Common
UL 325 DIP-Switches
ON
CO
NF
AN OR
SI/ MS
UL TO
-32
CER
5
N/C TIF
SA IED
C22 TO
.2
NO
CU
. 247
LA
R
SS
CA
Connect ONLY MONITORED
Devices
6
7 24 V Power
8 Full Open
9
DIP-switches MUST be turned ON for each device wired to terminal.
1 2 3 4
IMPORTANT: Photo sensors
must use Normally Closed (NC)
contacts with the beam set for
light operate (relay activated
when beam is not obstructed).
MO
SE VING
RI
OU GA
Ope
S IN TE
and rate
JU CAN
free gate
RY CA
of onl
Do
OR US
peo y whe
ple
or not allo
DE E
andn gat
ope
AT
rate w chil
obs e are
H
truc a is
Do
gat dre
tion in
n to
pat not stan e.
s. sigh
h whi
play
t
d
in
le in gat
gat
Rea
gat
e are
e is e pat
d own
mo h
a
er’s
ving or wal
ma
.
k thro
nua
l and
ugh
safe
ty
inst
ruc
tion
s.
Open Beam
UL 325 Terminal
N.C.
N.C.
WA
RN
IN
Wall
1 2 3 4
8-OFF
8-ON
8-OFF
8-ON
Open Edge
Closed Gate
Telephone
Entry
ON
7-OFF
7-OFF
7-ON
7-ON
Close Beam
2
3
4
5
1 2 3 4 5 6 7 8
Gate Close
Back-Off
Position
External Entrapment
Protection Devices
EX
ON
Normal Setting. Gate fully opens.
Gate stops short 1” from full open position. Used for a reversing edge device.
Gate stops short 2” from full open position. Used for a reversing edge device.
Gate stops short 3” from full open position. Used for a reversing edge device.
1
IMPORTANT: Only 1 monitored Device can be connected
to each input. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
Open Edge
Gate Open
Back-Off
Position
6-OFF
6-ON
6-OFF
6-ON
24 Volt Power
Hz
lew
ood
ON Fail-Secure. Lock engages after each cycle. CAUTION: Do not use this setting unless
the 2600-862 manual release kit has been installed or damage will occur to operator.
5-OFF
5-OFF
5-ON
5-ON
ASE
Inc.
Close Edge
7 and 8
g,
OFF Auto-close timer is OFF. Manual input required to close gate.
ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
60
D
rKin
4702-010
DIP-Switches
120 S. Glasgow Avenue
Inglewood, California 90301
All potential entrapment areas MUST be
protected with an external entrapment
protection device.
At least ONE external entrapment protection
device MUST be installed or the operator
will NOT function.