HI 98186 Dissolved Oxygen and BOD Meter with Backlit Graphic LCD Display S c r e e n H i g h l i g h t s DISSOLVED OXYGEN Industrial Grade Portable with Extended Range HI 98186 dissolved oxygen meter includes barometric pressure measurement and calibration with a user selectable unit (mmHg, inHg, atm, mbar, psi, kPa) along with salinity, pressure and temperature compensation. • Extended range up to 50 ppm BOD Parameters and Records All necessary parameters for BOD testing can be set and displayed at once. A list of all saved BOD data can be easily retrieved and shown on the LCD display. and 600% saturation • Built-in barometer • Salinity, pressure and temperature compensation Inductive charger BOD Results BOD is calculated in mg per liter from the difference between the initial and final dissolved oxygen concentration readings. Batteries can be recharged using HANNA’s inductive recharger. Simply leave the meter on the charger for a few hours and you’re ready to go. The charger can be powered using the included HANNA adapter. SPECIFICATIONS HI 98186 Dissolved Oxygen Range 0.00 to 50.00 ppm; 0.0 to 600.0 % saturation Barometric Pressure 450 to 850 mmHg Salinity Compensation 0 to 70 ppt (g/L) Temperature -20.0 to 120.0°C (-4.0 to 248.0°F) Dissolved Oxygen Resolution 0.01 ppm; 0.1% saturation Barometric Pressure 1 mm Hg Temperature OUR Results Measured in mg of oxygen consumed per L per hour. Dissolved Oxygen Accuracy 0.1°C/°F 0 to 300%: ±1.5% of reading or ±1.0%, whichever is greater; 300 to 600%: ±3% of reading; 0 to 30 mg/L: ±1.5% of reading or 0.10 mg/L, whichever is greater; 30 mg/L to 50 mg/L: ±3% of reading Barometric Pressure ± 3 mmHg within ±15% from the calibration point Temperature Measurement Modes ±0.2°C/±0.4°F (excluding probe error) Direct DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate) Dissolved Oxygen Calibration SOUR Results Measured in mg of oxygen consumed per g of volatile suspended solids per hour. BOD gives an indication of the biodegradable organic material present in a sample of water. The dissolved oxygen concentration is measured before and after an incubation period of 5 days and the BOD is calculated in mg per liter from the difference. OUR and SOUR are used to determine the oxygen consumption or respiration rate. OUR is measured in mg of oxygen consumed per liter per hour, and SOUR is measured in mg of oxygen consumed per gram of volatile suspended solids per hour. www.hannainst.com Automatic, 1 or 2 points or manual, 1 point Barometric Pressure 1 point Temperature 1 or 2 points Temperature Compensation Probe Automatic from 0.0 to 50.0°C (32.0 to 122.0°F) HI 76407/4F Polarographic with built-in temperature sensor + 4m cable Logging Log-on-demand 400 samples PC Connectivity Opto-isolated USB (with HI 92000 software) Battery Type/Life (4) 1.2V AA rechargeable batteries/approx. 200 hrs continuous use (without backlight); HI 710042 inductive recharger (included) Auto-off Environment / Dimensions / Weight 4 User Selectable: 5, 10, 30, 60 min or can be disabled IP67 / 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”) / 525 g (1.1 lbs.) ORDERING INFORMATION HI 98186-01 (115V) and HI 98186-02 (230V) are supplied with HI 76407/4F dissolved oxygen probe with built-in temperature sensor with 4 m (13’) cable; (2) spare membranes; electrolyte solution; (4) rechargeable batteries; HI 710042 inductive battery charger with power adapter; rugged carrying case and instructions. PROBES SOLUTIONS HI 76407/10 DO probe with 10 m (33') cable HI 76407/20 DO probe with 20 m (67') cable HI 7040M HI 7040L HI 7041S HI 76407A/P 5 spare membranes Zero oxygen solution, 250 mL Zero oxygen solution, 500 mL Electrolyte solution, 30 mL 4.7
© Copyright 2026 Paperzz