LED Wall-PACK/Flood Light DataSheet Cat# 71390

LED
Wall-PACK/Flood Light
DataSheet
Cat# 71390
Wet Locations Use
RoHS
Model:
OVERALL LAMP
PARAMETERS
LED DRIVER
LED
LIFESPAN &
ENVIRONMENT
SAFETY&EMC
71390
Input Voltage
100-277VAC
Input Current
0.5A @100V / 0.2A @277V
Input Power
21W
Power Factor
PF≥0.95
Luminance
1874 LM
Luminous Efficiency
87 LM/W
CRI
75
Beam Angle
140°
Main Structure
Alluminium + Tempered Glass
Output Voltage
24-48VDC
Output Current
0.5A
Driver Efficiency
87%
LED Brand
CXA1512
LED Quantity
2 PCS
LED Manufacturer
Cree
LED Efficacy
120 LM/W
Color Temperature
WW/NW/PW/CW (5125K)
Lifespan
50000 Hrs.
Warranty
5 Years
IP Rating
IP54 Wet Locations
Operating Temperature
-40F - +104F
Storage Temperature.Humidity
-40F - +176F , 10—90% RH
Safety Norms
UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471
Withstand Voltage
I/P-FG: 2121VDC
Grounding Resistance
25A 100mΩ
Electromagnetic Compatibility
EN55015, EN61000-2-3, EN61000-3-3, EN61547
Dimensions:
1. Direct to wall
installed photo controller place
2. With Knuckle
TL-WMA501
3. With bracket
LUMINAIRE PHOTOMETRIC
www.morrisproducts.com
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
LM-79-08 Test Report
For
Morris Products Inc.
53 Carey Rd.
Queensbury, NY 12804
Outdoor Wall-Mounted Area Luminaires
Model name(s): 71390
Test & Report By:
Review By:
Sean Zhuo
Engineer: Sean Zhuo
Manager: Tommy Liang
Date: Mar.20,2014
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or
any agency of the Federal Government.
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
1 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
U.S. Department of Energy
Lighting FactsTM Uniform LM-79 Reporting Template
Laboratory Information:
Name of Test Laboratory
Standard-Tech Co. Ltd
Date of Test Report
Mar.20,2014
Test Report No.
GZE140307-C
Laboratory Contact Name
Tommy Liang
Product Information:
Organization Name
Morris Products Inc.
Brand Name
Morris
Model Number
71390
SKU (if available)
N/A
Type of Luminaire
(for integral lamps, list base type and lamp type)
Outdoor Wall-Mounted Area Luminaires
Luminaire Aperture (for downlights)
--
in.
Luminaire Length
--
mm
Luminaires Width
--
mm
Number of Units (modular products)
N/A
s
Integrating Sphere
Goniophotometer
Output
Output
Input Wattage
--
21.30
W
Input Current
--
0.1822
A
Input Voltage (ac)
--
120.1
V
Power Factor
--
0.9731
Off-State Power
--
0
W
Total Initial Lumen Output
--
1874.3
lm
Initial Lumen Efficacy
--
87.99
lm/w
Correlated color temperature / CCT
5125
--
K
Color rendering index / CRI
75.0
--
0
--
0.0001
--
Electrical Measurements:
Photometric Characteristics
R9 Value
Duv
Luminous Intensity Distribution
Center beam candlepower (if applicable)
887.0
cd
Beam angle (if applicable)
95.9
°
88.15
%
11.80
%
Zonal lumens in the 90°-120° zone
0.00
%
Zonal lumens in the 120°-180° zone
0. 05
%
Zonal lumens in the 0°-60° zone
-----
Zonal lumens in the 60°-90° zone
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
2 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Test Specifications:
Date of Receipt
: Mar.14.2014
Date of Test
: Mar.19.2014
Test item
: Total Luminous Flux, Luminous Distribution Intensity, Luminous
Efficacy, Correlated Color Temperature, Color Rendering Index,
Chromaticity Coordinate, Electrical parameters
Reference Standard
IES LM-79-2008 Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI C78.377-2008 Specifications for the Chromaticity of Solid State
Lighting Products
CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering
Properties of Light Sources
CIE 15-2004 Technical Report Colorimetry
IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems
Reference Work
QD25
Instruction
Test Methods
1. Photometric and Electrical measurements – Light Distribution Method:
Photometric parameters were measured using the goniophotometer and software. The ambient
temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the
sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was
stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were
calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.
2. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
3 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
1. Product Information:
Brand Name
Model Number
Morris
71390
Luminaire Type
Outdoor Wall-Mounted Area Luminaires
Rated Voltage / Frequency
100 ~ 277 Vac, 50/60 Hz
Nominal Power
20W
Rated Initial Lamp Lumen
--
Declared CCT
5000K
LED Manufacturer
CREE
LED Model
CXA1507
Sample Receipt Date
Mar.14.2014
Sample Number
140307-3
Photo
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
4 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
IES LM-79 2008
Test date
2014-03-19
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
71390
Model Number
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
120.1
60
0.1822
21.30
0.9731
16.91
277.0
60
0.0857
21.61
0.9102
19.52
140307-3
Sphere-Spectroradiometer Method:
Parameter
Result
Test Voltage (V)
120.0
R1
74
R9
0
Frequency (Hz)
60
R2
79
R10
49
75.0
R3
81
R11
73
0
R4
76
R12
46
5125
R5
74
R13
74
Color Rendering Index (CRI)
R9
CCT (K)
Special Color Rendering Indices
Chromaticity (x, y)
x=0.3417
y=0.3492
R6
71
R14
89
Chromaticity (u’, v’)
u'=0.2101
v'=0.4830
R7
83
R15
70
R8
62
--
--
Duv
0.0001
Goniophotometer Method:
Parameter
Result
Test Voltage (V)
120.1
Frequency (Hz)
60
Test Current (A)
0.1822
Power Factor
0.9731
Test Power (W)
21.30
Total Luminous (lm)
1874.3
Luminous Efficacy (lm/W)
87.99
Beam Angle°
95.9
Center Beam Candle Power (cd)
887.0
S/MH(C0/180)
1.20
S/MH(C90/270)
0.87
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
5 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Spectral Power Distribution
Spectral Power Distribution:
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
6 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Chromaticity Diagram
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
7 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Zonal Lumen Tabulation
Zone
Lumens
% Lamp / Luminaire
0~ 10°
82.3
4.39%
10 ~ 20°
227.7
12.15%
20 ~ 30°
326.5
17.42%
30~ 40°
368.5
19.66%
40 ~ 50°
354.4
18.91%
50~ 60°
292.5
15.61%
60 ~ 70°
180.6
9.64%
70 ~ 80 °
38.71
2.07%
80 ~ 90 °
1.276
0.07%
90 ~ 100 °
0
0.00%
100 ~ 110 °
0.0054
0.00%
110 ~ 120 °
0.1129
0.01%
120 ~ 130 °
0.2273
0.01%
130 ~ 140 °
0.3388
0.02%
140 ~ 150 °
0.3589
0.02%
150 ~ 160 °
0.3414
0.02%
160 ~ 170 °
0.2497
0.01%
170 ~ 180 °
0.1087
0.01%
Zone
Lumens
% Lamp / Luminaire
0~60 °
1652
88.15%
60 ~90°
221
11.79%
0 ~90°
1873
99.95%
90~180°
1
0.05%
0~180°
1874
100.00%
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
8 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Photometric Data
Illuminance Plots
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
9 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
10 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
Candela Table - Type C
0
22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 867 867 867 867 867
867 867
867 867
867 867
867 867
867 867
867 867
1 871 871 870 868 868
865 863
863 864
864 864
865 866
870 871
872 871
2 874 873 872 869 868
862 860
858 860
859 860
864 865
872 874
876 874
3 878 876 874 870 869
859 857
857 861
858 856
862 864
873 878
880 878
4 882 879 876 871 870
856 857
854 856
855 855
860 861
874 881
883 882
5 884 881 877 872 870
853 855
846 849
848 851
857 860
875 883
885 884
6 884 882 880 873 872
850 849
841 844
842 845
855 859
875 885
886 884
7 884 882 880 873 872
849 845
836 842
837 839
853 856
874 886
886 884
8 881 881 880 874 871
847 841
832 843
836 834
853 854
873 887
883 881
9 878 878 880 875 869
842 837
834 840
836 830
851 851
872 887
880 878
10 873 874 878 875 867
835 833
827 828
829 829
846 848
869 886
875 873
11 868 868 876 874 865
828 834
813 808
813 825
841 843
866 885
871 868
12 862 862 873 873 861
821 832
794 782
792 819
835 839
863 884
866 862
13 854 856 867 871 857
814 825
769 749
766 810
829 833
859 883
860 854
14 847 850 864 869 852
807 812
739 715
735 795
823 828
854 882
854 847
15 838 845 862 867 847
800 795
706 682
704 776
819 823
850 882
849 838
16 835 838 858 863 841
792 774
674 653
674 755
814 819
844 882
842 835
17 829 832 856 859 835
789 751
648 638
649 733
808 813
839 883
834 829
18 823 829 853 855 828
783 725
628 625
629 707
799 807
835 881
828 823
19 819 823 851 851 820
775 698
614 615
617 683
788 801
830 879
823 819
20 815 817 849 846 812
765 674
603 603
605 662
777 794
825 876
819 815
21 810 814 847 842 803
755 652
592 593
595 643
764 788
819 873
815 810
22 802 810 845 837 794
743 633
582 580
585 623
750 780
813 870
812 802
23 788 805 844 831 784
729 617
571 568
572 606
734 772
807 868
806 788
24 773 798 840 825 774
715 605
559 553
561 590
718 765
800 865
796 773
25 759 789 838 818 762
697 594
546 535
549 578
702 756
793 862
784 759
26 750 777 834 810 751
678 584
533 514
536 566
684 751
786 857
771 750
27 747 768 830 802 739
660 573
514 490
519 556
668 742
778 847
762 747
28 746 764 825 793 726
642 562
493 465
499 546
654 735
772 838
759 746
29 745 763 818 785 712
628 551
470 437
477 535
640 726
764 827
761 745
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
11 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
30 746 765 809 775 698
614 536
448 407
455 525
624 716
757 816
766 746
31 748 767 800 766 686
599 521
422 375
430 513
607 706
749 804
770 748
32 752 770 789 756 673
581 506
395 342
403 500
590 695
741 792
776 752
33 759 773 778 745 661
563 488
366 308
375 487
572 685
732 782
782 759
34 767 775 768 734 648
545 469
336 274
346 473
554 674
723 776
786 767
35 774 774 760 723 636
526 448
308 239
322 456
536 662
712 772
790 774
36 780 774 754 712 624
509 426
282 208
294 436
517 650
701 769
793 780
37 784 775 749 701 612
493 404
250 179
258 417
502 637
690 765
796 784
38 787 775 744 691 601
479 379
213 153
221 396
488 624
681 761
796 787
39 788 773 738 682 590
467 354
180 128
189 372
476 610
674 758
796 788
40 788 771 732 672 580
454 327
151 105
159 347
463 597
670 752
794 788
41 788 769 728 657 568
441 299
125
87
131 321
449 579
662 747
791 788
42 786 766 723 646 551
427 270
102
73
107 292
436 560
654 743
788 786
43 783 760 718 640 534
412 239
84
62
86 263
421 542
648 738
784 783
44 779 755 713 641 516
398 212
69
52
69 234
406 527
645 731
777 779
45 772 749 708 644 502
383 183
58
45
57 206
391 513
643 725
770 772
46 765 742 702 642 489
367 156
48
39
47 178
374 500
638 719
761 765
47 756 733 695 637 477
351 129
41
35
41 149
357 486
631 712
752 756
48 746 723 687 625 464
333 104
36
32
35 120
339 473
620 703
740 746
49 734 712 677 609 450
316
80
31
30
31
93
320 455
608 693
727 734
50 720 700 664 592 434
298
59
27
29
27
68
301 433
595 681
714 720
51 706 687 650 576 411
279
44
25
29
25
46
282 408
581 666
698 706
52 691 673 634 559 387
260
32
24
28
24
30
263 385
566 650
682 691
53 676 657 616 541 367
240
23
23
26
23
19
242 366
549 633
666 676
54 659 641 599 520 350
219
16
23
25
23
12
221 350
531 614
648 659
55 643 624 581 499 335
197
11
22
24
22
8
200 333
510 595
630 643
56 624 606 563 479 322
176
8
21
23
21
7
178 316
489 574
610 624
57 604 588 544 459 306
154
7
20
22
20
6
158 299
468 554
590 604
58 584 568 527 441 292
132
6
20
21
20
5
139 282
447 534
569 584
59 563 549 509 424 277
112
6
19
20
18
5
120 265
426 514
548 563
60 541 529 492 408 262
92
5
17
18
16
4
102 249
406 494
527 541
61 518 509 474 392 247
73
5
16
17
14
4
84 232
387 475
505 518
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
12 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
62 486 489 455 375 232
55
4
14
15
12
4
67 215
369 455
484 486
63 448 467 436 359 217
38
4
13
14
11
4
51 198
351 435
457 448
64 400 439 415 343 201
25
3
11
13
10
3
37 182
333 415
425 400
65 344 403 395 327 185
14
3
10
12
9
3
27 166
315 395
381 344
66 283 358 374 309 169
8
3
9
10
8
3
18 150
297 374
330 283
67 220 305 353 292 153
5
3
8
8
7
3
11 134
279 353
274 220
68 160 247 331 274 137
3
3
7
7
6
3
6 118
260 331
213 160
69 106 186 309 256 122
3
3
6
6
6
2
3 104
241 301
154 106
70
62 130 283 237 106
2
3
5
5
5
2
2
90
222 261
102
62
71
31
81 250 217
92
2
2
5
4
5
2
2
77
202 213
59
31
72
14
43 206 197
78
2
2
4
4
5
2
2
65
181 161
28
14
73
8
18 159 177
64
2
2
4
4
4
1
1
56
160 110
12
8
74
6
9 110 156
53
1
2
4
3
4
1
1
48
140
65
6
6
75
5
5
66 136
45
1
1
4
3
4
1
1
41
120
31
5
5
76
4
4
32 117
39
1
1
4
3
4
1
1
35
101
11
4
4
77
3
3
12
99
33
1
1
3
3
3
1
1
30
80
5
3
3
78
2
3
5
80
28
1
1
3
3
3
1
1
25
53
4
2
2
79
2
2
4
59
23
1
1
3
3
3
1
1
20
29
3
2
2
80
1
2
3
37
18
0
1
3
3
3
1
0
12
12
2
1
1
81
1
1
2
18
12
0
1
3
3
3
1
0
5
4
2
1
1
82
1
1
1
5
5
0
1
3
3
3
1
0
2
2
1
1
1
83
0
1
1
2
3
0
1
3
3
3
0
0
1
1
1
0
0
84
0
0
1
2
1
0
1
2
2
2
0
0
1
1
0
0
0
85
0
0
0
1
0
0
1
1
1
1
0
0
0
1
0
0
0
86
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
87
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
88
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
89
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
90
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
13 / 14
Report No.: GZE140307-C
NVLAP LAB CODE 201011-0
3. Test Equipment
Equipment ID
Equipment Name
Last Calibration Date
Next Calibration Date
ST-R-336
2 meter Integrating Sphere
2013-07-08
2014-07-07
ST-R-331
Spectral analysis system HAAS-2000
2013-06-21
2014-06-20
D204
Standard Lamp
2013-06-28
2014-06-27
PF2010
Power Meter for Integrating Sphere
2013-06-20
2014-06-19
EE-09
Goniophotometer system
2013-06-21
2014-06-20
D908S
Standard Lamp
2013-07-05
2014-07-04
PF210
Power Meter for Goniophotometer
2013-06-20
2014-06-19
ST-R-181A
Temperature Tester
2013-08-14
2014-08-13
****** END OF DATASHEET PACKAGE ******
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
14 / 14