White Light Ltd Hire Mains Distribution Systems P1: Type 1-5 rack flightcased 63A 3ø input distributions P2: Type 6-7 rack flightcased Power Lock 3ø input distributions P3: “Event” range HDPE distributions P4: Type 10-12 rack flightcased 60A - socapex distributions P5: Type 13&16 rack flightcased Power Lock - socapex distributions P6: Miscellaneous Type 1 Distribution Input: Protection: 63A 3PH, 2m trailing lead 4 pole isolator Main O/P: Protection: 6 * 63A 1PH Cee17, (2 per phase) Type D MCB per socket Aux O/P: Protection: 13A, 15A, 16A sockets on phase R1 16A RCBO per socket Type 2 Distribution Input: Protection: 63A 3PH, 2m trailing lead 4 pole isolator Main O/P: Protection: 3 * 63A 1PH Cee17, (1 per phase) 1 * 32A 3PH Cee17 Type D MCB per socket Aux O/P: Protection: 13A, 15A, 16A sockets on phase S2 16A RCBO per socket Type 3 Distribution Input: Protection: 63A 3PH, 2m trailing lead 4 pole isolator Main O/P: Protection: 3 * 63A 3PH Cee17 1 * 32A 3PH Cee17 Type D MCB per socket Aux O/P: Protection: 13A, 15A, 16A sockets on phase T3 16A RCBO per socket Type 4 Distribution Input: Protection: 63A 3PH, 2m trailing lead 4 pole isolator Main O/P: Protection: 3 * 32A 3PH Cee17 3 * 32A 1PH Cee17, (1 per phase) Type D MCB per socket Aux O/P: Protection: 13A, 15A, 16A sockets on phase R1 16A RCBO per socket Type 5 Distribution Input: Protection: Main O/P: 1 63A 3PH, 2m trailing lead Type D MCB/Option of 30mA RCD 1 * 63A 3PH Cee17 Type 6 Distribution Input: 3PH Power Lock Thru: 3PH Power Lock Protection: 400A MCCB, adjustable to 250A Switchable VTVS RCD Digital residual current meter Fault lamp & buzzer Main O/P: 6 * 63A 3PH Cee17 1 * 32A 3PH Cee17 Protection: Type D MCB per socket Aux O/P: Protection: 13A, 15A, 16A socket per phase 16A RCBO per socket Type 7 Distribution Input: Thru: 3PH Power Lock 3PH Power Lock Main O/P: Protection: 3PH Power Lock 400A MCCB, adjustable to 250A Switchable VTVS RCD Digital residual current meter Fault lamp & buzzer Aux O/P: Protection: 32A 3PH Cee17 Type D MCB Type 6-B Distribution Input: 3PH Power Lock Thru: 3PH Power Lock Protection: 400A MCCB, adjustable to 250A Switchable VTVS RCD Digital residual current meter Fault lamp & buzzer Main O/P: Protection: 1 * 125A 3PH Cee17 6 * 63A 3PH Cee17 VTVS RCD, Type C MCB per socket Main O/P: Protection: 3 * 32A 3PH Cee17 Type C MCB per socket Aux O/P: Protection: 13A * 3, 16A 1PH * 6 16A RCBO per socket Overall current/voltage meter 2 * USB charging sockets Earth point provided on distro 2 “K9” Input: O/P: Protection: 32A 1PH, 2m trailing lead 4 * 16A 1PH Cee17 16A Type C MCB per socket Type 14E Distribution Input: O/P: Protection: 32A 3PH 3 * 32A 1PH Cee17 Type C RCBO per phase Earth point provided on distro Type 4E Distribution Input: Protection: 63A 3PH 4 pole isolator O/P: Protection: 3 * 32A 3PH Cee17 Type D MCB per socket O/P: Protection: 3 * 32A 1PH Cee17 Type C RCBO per socket O/P: Protection: 3 * 16A 1PH Cee17 Type C RCBO per socket Earth point provided on distro Type 9E Distribution Input: Protection: 63A 3PH 4 pole isolator O/P: Protection: 18 * 16A 1PH Cee17 16A Type C RCBO per socket Earth point provided on distro Type 15E Distribution Input: Protection: 32A 3PH 4 pole isolator O/P: Protection: 9 * 16A 1PH Cee17 16A Type C RCBO per socket Earth point provided on distro 3 Type 10 Distribution Input: Protection: 63A 1PH 2-pole 63A MCB Main O/P: Protection: 2 * Socapex Type D 10A MCB per way Aux O/P: Protection: 2 * 16A sockets 16A MCB per socket Type 11 Distribution Input: Protection: 63A 3PH 4-pole 63A MCB Main O/P: Protection: 6 * Socapex, (2 per phase) 30mA RCD per Socapex Type D 10A MCB per way Aux O/P: Protection: 3 * 16A 1PH Cee 17 sockets 16A 30mA RCBO per socket Type 12 Distribution 4 Input: 63A 3PH, 2m trailing lead Main O/P: Protection: 3 * Socapex, (1 per phase) Type D 10A MCB per way Aux O/P: Protection: 1 * 16A 1PH Cee17 16A RCBO Note: Some units available with 63A 3PH thru Type 13 Distribution Input: Thru: Protection: Powerlock Powerlock 400A MCCB O/P: Protection: 9 * Socapex (3 per phase) 30mA RCD per Socapex Type C 10A MCB per way O/P: Protection: 6 * 16A 1PH Cee17 Type C RCBO per socket O/P: Protection: 63A 3PH Cee17 30mA RCD & 63A Type C MCB Type 16 Distribution 5 Input: Thru: Protection: Powerlock Powerlock 400A MCCB O/P: Protection: 12 * Socapex multi (4 per phase) 16A Type C RCBO per way O/P: Protection: 6 * 16A 1PH Cee17 Type C RCBO per socket O/P: Protection: 63A 3PH Cee17 30mA RCD & 63A Type C MCB Type 3A Distribution Input: Protection: 125A 3PH, 4 pole isolator Main O/P: Protection: 3 * 63A 3PH Cee17 1 * 32A 3PH Cee17 Type D MCB per socket Aux O/P: Protection: 16A 1PH Cee17 * 3 16A RCBO per socket Rubber Box 60A 1PH – 3*32A & 6*16A 1PH Input: Protection: 63A 1PH 2 pole isolator O/P: Protection: 3 * 32A 1PH Cee17 Type C RCBO per socket O/P: Protection: 6 * 16A 1PH Cee17 Type C RCBO per socket Powerlock – 3*125A Distribution 6 Input/Thru: Powerlock O/P: Protection: 3 * 125A 3PH Cee17 125A 4-Pole MCB per socket
© Copyright 2026 Paperzz