Egyptian Accreditation Council EGAC المجلـــس الوطنـــى لإلعتمــاد إيجاك Schedule of Accreditation Calibration Laboratory of Helwan Company for Diesel Engines Helwan Company for Diesel Engines (Factory 909) Schedule No.: 297001B Ain Helwan - Helwan - Egypt Date of issue: March 1, 2010 First accreditation date: September 17, 2000 Issue No.: 2 Range Calibration and Measurement Capability*(±) Gauge Blocks Calibration 0 ـــ50 mm 50 ـــ100 mm 0.25 µm 0.41 µm External Micrometer Calibration up to 200 mm 200 ـــ500 mm 1.8 µm 2.4 µm up to 150 mm 150 ـــ200 mm up to1 mm (L.R. 0.001) up to10 mm (L.R. 0.01) 1.7 µm 1.7 µm 0.77 µm 2.9 µm Verneir Caliper Calibration up to 500 mm 12 µm Verneir Depth Gauge Calibration up to 500 mm 12.7 µm ES 617:1991 DIN 878 ES 313:1991 DIN 862 ES 912:2003 Snap Gauge Calibration up to 40 mm > 40 ـــ95 mm 1 µm 1.2 µm ES 423:1973 ES 670:1965 DIN 7162 up to 40 mm > 40 ـــ95 mm up to 40 mm > 40 ـــ95 mm up to 30 mm 0.7 µm 0.9 µm 0.8 µm 1 µm 1 µm Measured Quantity Brief Description of Measurement and Equipment Used ES 1178:2007 ISO 3650:1998 ES 163:2001 Internal Micrometer Calibration Dial Indicator Calibration Ring Gauge Calibration Plug Gauge Calibration Internal Thread Gauge Calibration Valid to : February 28, 2014 ES 528:1991 ES 423:1973 ES 670:1965 DIN 7162 - Gauge Blocks Comparator S.N.: 58361 - Gauge Blocks Set grade 0 S.N.: 586/c1 - Gauge Blocks Set grade 2 S.N.: 1055 - Meterscope Instrument S.N.: 1864 - Gauge Blocks Set grade 2 S.N.: 1055 - Gauge Blocks Set grade 2 S.N.: 1055 - Pin Standard Gauge S.N.: 2/1 - Meterscope Instrument S.N.: 1864 ES 1118:1972 L.R.: Least Reading (*) Calibration and measurements capabilities are to be experssed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximatly 95%. Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt Tel.: (202) 5275220/5275224/5275225/5275227 Fax: (202) 5275226 F09P15G 5 / Dec 2009 Page 1 of 1 مللقوىرج – مصوج-1 ملعاوى – بوج نض كورنيش ملعاوى )202( 5275220/ 5275224 / 5275225 /5275227 : تلشفرن )202( 5275226 : فىكس Egyptian Accreditation Council EGAC المجلـــس الوطنـــى لإلعتمــاد إيجاك Schedule of Accreditation Calibration Laboratory of Helwan Company for Diesel Engines Helwan Company for Diesel Engines (Factory 909) Schedule No.: 297001B Ain Helwan - Helwan - Egypt Date of issue: March 1, 2010 First accreditation date: September 17, 2000 Issue No.: 2 Measured Quantity Range Calibration and Measurement Capability*(±) External Thread Gauge Calibration up to 30 mm 1 µm Valid to : February 28, 2014 Brief Description of Measurement and Equipment Used ES 1145:1972 L.R.: Least Reading (*) Calibration and measurements capabilities are to be experssed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximatly 95%. Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt Tel.: (202) 5275220/5275224/5275225/5275227 Fax: (202) 5275226 F09P15G 5 / Dec 2009 Page 2 of 1 مللقوىرج – مصوج-1 ملعاوى – بوج نض كورنيش ملعاوى )202( 5275220/ 5275224 / 5275225 /5275227 : تلشفرن )202( 5275226 : فىكس
© Copyright 2026 Paperzz