Cast Iron Strainers CI-125, F-125 Cv Values Type CI-125F-125 Sizes 2" to 4" 6" to 8" Connections Standard Screen 14" & 18" ANSI 125 Construction Max Saturated Steam Pressure 10" & 12" SizeCv 2" 70 2-1/2" 110 3" 165 4" 280 5" 450 6" 650 8" 1100 10" 1650 12" 2400 14" 3500 16" 5400 18" 6300 Cast Iron 147 psig 20 Mesh 125 psig 4" to 8" 1/8" perf 100 psig 10" to 18" 1/8" perf 100 Mesh Options 60/100 mesh 4" to 6" 3/64" perf 8" to 18" 1/16" perf Steel or Brass Plug For water: (GPM)2 Pressure = Drop (Cv)2 Consult factory for other liquids. See TI-7-429-US for pressure drops on steam, air and other gases. SIZE 21/2" TO 18" CI-125 & F-125 Note: Conforms to WW-S-2739 when equipped with an optional bronze plug in the blow-off connection. Strainers Limiting Operating Conditions (non-shock) BLOWDOWN OFFSET ON SIZES 4"- 8" 260 500 450 CI-125 204 400 1 4 353 338 149 5 Saturated Steam 200 150 93 14"-18" F-125 10",12" F-125 38 100 0 0 100 (7) 50 (3) Pressure psig (barg) 125 150 (10) 3 2 Temperature °C Temperature °F 300 200 (14) 1 4 3 2 SIZE 2" CI-125 Pressure Shell Design Conditions Construction Materials Max. allowable No. Part 1 Body pressure 2 3 4 5 Cap/Bushing Cap Gasket Strainer Screen Cap Screws Material Cast Iron ASTM A126 CLB Cast Iron ASTM A126 CLB *Graphite Stainless Steel Steel CI-125: 200 psig/-20-150˚F 10",12" F-125: 125 psig/-20-353˚F 14",18" F-125: 100 psig/-20-338˚F 14 barg/-29-66˚C 9 barg/-29-178˚C 7 barg/-29-170˚C CI-125: 450˚F/0-125 psig 10",12" F-125: 353˚F/0-125 psig 14",18" F-125: 338˚F/0-100 psig 232˚C/0-9 barg 178˚C/0-9 barg 170˚C/0-7 barg Max. allowable temperature *2" – Copper Jacketed Gasket with Non-Asbestos Filler Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. 4:338 TI-7-415-US 10.12 Cast Iron Strainers CI-125, F-125 Spare Parts A 21/2" TO 6" CI-125 & F-125 BLOWDOWN CONN. OFFSET ON SIZES 4" - 18" B C Dimensions B C (NPT) 2" 8.7 222 5.7 1" 146 17 lb 7.7 kg 2-1/2" 10.5 267 6.7 1-1/4" 171 29 lb 13 kg 3" 12.0 305 7.6 1-1/4" 194 44 lb 20 kg 4" 14.9 378 10.6 1-1/4" 270 82 lb 37 kg 5" 17.2 438 12.9 1-1/2" 327 115 lb 52 kg 6" 8" 20.0 508 21.6 549 15.4 1-1/2" 391 15.5 2" 394 160 lb 73 kg 247 lb 112 kg 10" 25.8 654 18.5 2" 470 381 lb 173 kg 12" 29.9 759 21.8 2" 553 623 lb 282 kg 14" 33.3 845 25 2" 635 818 lb 371 kg 16" 38.8 984 26.5 2" 673 1421 lb 643 kg 18" 43.1 1096 31 2" 788 1582 lb 717 kg C Weight A Strainers A CI-125 B F-125 C 2" CI-125 ONLY Installation The strainer should be installed with the flow direction as indicated on the body, in a vertical down or horizontal pipeline. The strainer must be accessible for periodic removal of accumulated debris, by either blowing down or removal and cleaning of the screen. A 8" to 18" F-125 Screen C (state material, perforations or mesh & size of strainer) Cap Gasket Blowoff Bushing, 2" Cap B A A © Spirax Sarco, Inc. 2012 Size B (nominal) in inches and millimeters Note: Please provide date code when placing order for spare parts. Contact Technical Support for assistance if needed. TI-7-415-US Spirax Sarco, Inc., 1150 Northpoint Blvd, Blythewood, SC 29016 10.12 Telephone: (803) 714-2000 FAX (803) 714-2222 4:339
© Copyright 2025 Paperzz