NUAIRE’S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire’s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard mounting the MRXBOX95(AB)WH1 and MRXBOX95(AB)-WM2 Units. Offering the only complete MVHR acoustic and first fix solution to overcome both noise and ease the installation of heat recovery units. Nuaire’s solution addresses both duct and breakout noise, provides an aesthetically pleasing cupboard installation for the home occupant and reduces installation errors and time. These units are also available in Opposite Handed format. Typical Installation FIRST FIX SOLUTION FF-WH1/FF-WM2 Nuaire’s First Fix box is fixed to the underside of the floor slab at first fix stage of the build. The box has four airflow chambers with optional positions MRXBOX-FF-WH1 for 204x60mm spigots. Ceilings can then be boarded within the cupboard space easily and quickly without the risk of the spigots not aligning to the fan unit. SILENCER SIL-WH1/SIL-WM2 Nuaire has created a unique solution that is not only designed to reduce noise significantly, addressing duct and breakout noise, but is visibly appealing for the home occupant. It can be used with or without the First Fix Solution. MRXBOX95(AB)-WH1/ MRXBOX95(AB)- WM2 Nuaire’s Silencer and First Fix solution are compatible with the MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 heat recovery units, which are designed for medium to large properties. 10 Acoustic data for MRXBOX95(AB)-WH1 with Silencer and/or First Fix WH1 with SIL Sound Data Curve Max. Power/W 1 150 WH1 with FF Sound Data Curve 150 WH1 with FF & SIL Sound Data 150 125 250 500 1K 2K 4K 8K dBA @3m Sound power levels dB re 1pW 40 45 56 41 53 61 49 58 59 39 53 53 25 39 43 <16 34 40 <16 30 25 <16 26 16 Frequency/Hz 63 125 250 500 1K 2K 4K 8K 37 dBA @3m Sound power levels dB re 1pW Open Inlet Open Outlet Breakout 44 48 56 44 58 61 53 63 59 43 60 53 40 55 43 32 53 40 19 44 25 <16 35 16 Frequency/Hz 63 125 250 500 1K 2K 4K 8K 33 42 53 25 32 43 <16 25 40 <16 22 25 <16 <16 16 Max. Power/W 1 63 Open Inlet Open Outlet Breakout Max. Power/W 1 Curve Frequency/Hz 37 dBA @3m Sound power levels dB re 1pW Open Inlet Open Outlet Breakout 36 38 56 31 45 61 43 49 59 37 The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m – to obtain the spherical radiated data, subtract 3dBA. Silencer Corrections SIL Corrections FF Corrections FF+SIL Corrections Open Inlet -8 -10 -9 -10 -22 -24 -16 -13 Open Outlet -11 -10 -9 -14 -23 -26 -20 -15 Breakout 0 0 0 0 0 0 0 0 Open Inlet -4 -7 -5 -6 -7 -7 -6 -4 Open Outlet -8 -5 -4 -7 -7 -7 -6 -6 Breakout 0 0 0 0 0 0 0 0 Open Inlet -12 -20 -15 -16 -22 -24 -19 -16 Open Outlet -18 -18 -18 -25 -30 -35 -28 -26 Breakout 0 0 0 0 0 0 0 0 11 NUAIRE’S MVHR Technical DIMENSIONS (mm) for WH1 unit SIL-WH1 655 TOP VIEW 445 SIDE VIEW 458 CRS = = FF-WH1 = 227 CRS 432 = Ø150 FRONT/REAR VIEW 400 = = = = 204 x 60 666 TOP VIEW 458 CRS = = SIDE VIEW = = 242 CRS = 227 CRS Ø150 155 489 107 = 110 FACE TO BE MOUNTED NEAREST TO WALL 30 COMPLETED SYSTEM SIDE VIEW CROSS BRACE = = 672 12 1132 66 648 965 1110 462 167 TOP VIEW ADJUSTABLE FEET WALL/SOLID STRUCTURE ANGLE BRACKET Consultants Specification SIL-WH1 OPERATION The unit offers the facility to be fitted directly to the MVHR unit and plenum chamber without the need for spigots reducing breakout noise. However, there is the capability to fit 150mm circular spigots as an alternative option. The supply and extract ventilation unit shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. This unit is also available in Opposite Hand formatting. The unit shall be fully lined with acoustic material offering excellent noise reduction. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c, kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The extracted air shall also be filtered before it reaches the heat exchanger block. Wall mounting brackets are to be supplied as part of the system to allow the MVHR unit to be raised after other system components are installed to form an airtight seal and enable the installation to be levelled. The unit shall be clamped to the MRXBOX95(AB)-WH1 unit to provide an efficient seal and ensure correct alignment. The unit shall be fixed in position during installation as a standalone section without relying on other system elements. FF- WH1 The unit shall be supplied with 204mm x 60mm rectangular spigots to connect to the duct run, with the ability to be fitted in eight separate positions reducing the requirement for bends in the system. The unit offers the facility to be fitted directly to the mating sections without the need for spigots reducing breakout noise, additional 150mm circular spigots to be supplied as an alternative option. TECHNICAL DATA Units shall be one of MRXBOX95AB-WH1, MRXBOX95-WH1, MRXBOX95AB-WH1-OH, MRXBOX95-WH1-OH as manufactured by Nuaire. SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 95%. The heat exchanger shall be protected by G3 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency EC fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40°C. The unit shall be supplied complete with a condensate drip tray and 21.5mm drain connection. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from the switched live signal from light/ remote switches or any ancillary sensors. When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. INTEGRAL AUTOMATIC SUMMER BYPASS (MRXBOX95AB-WH1 & MRXBOX95AB-WH1-OH only) Including Automatic SUMMER BYPASS where intake and return air temperatures shall be measured so that supply air temperatures can be maximised during winter months and minimised as external ambient temperature rises. The Summer Bypass damper shall be opened by a wax actuator. Supply and Extract air shall be filtered irrespective of the bypass setting (open or closed). CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components prewired and factory fitted by the manufacturer: • Independent control of background supply and extract flow rates • Independent control of boost speed supply and extract flow rates • Integral fan failure indication • Integral S/L terminal for boost from remote switch, e.g. light switch, kitchen boost switch • Integral heat exchanger frost protection • Discreet daily run monitor. • Integral humidistat. OPTIONAL CONTROLS MRXBOX95-RFI Remote fail indicator. The unit shall be suitable for 150mm diameter circular ducting. MRXBOX95-PIR (Passive Infra-Red) A low voltage sensor which detects movement and activates system. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. MRXBOX95-HUM A low voltage sensor which activates the system when the relative humidity level is above a set point. The unit shall be offered with a 5 year warranty. MRXBOX-VSC An LCD controller for MVHR system with a 3.2” touch screen display. 13 NUAIRE’S MVHR Acoustic data for MRXBOX95(AB)-WM2 with Silencer and/or First Fix WM2 with SIL Sound Data Curve Max. Power/W 1 150 WM2 with FF Sound Data Curve 150 WM2 with FF & SIL Sound Data 150 125 250 500 1K 2K 4K 8K Open Inlet Open Outlet Breakout 49 44 61 47 55 61 52 62 56 46 53 53 28 41 47 23 34 44 20 31 35 21 28 33 Frequency/Hz 63 125 250 500 1K 2K 4K 8K 53 47 61 50 60 61 56 67 56 50 60 53 43 57 47 40 53 44 30 45 35 30 37 33 Frequency/Hz 63 125 250 500 1K 2K 4K 8K 40 42 53 28 34 47 <16 25 44 <16 23 35 <16 17 33 45 37 61 37 47 61 46 53 Silencer Corrections FF Corrections FF+SIL Corrections 14 37 dBA @3m 37 dBA @3m Sound power levels dB re 1pW Open Inlet Open Outlet Breakout The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m – to obtain the spherical radiated data, subtract 3dBA. SIL Corrections dBA @3m Sound power levels dB re 1pW Open Inlet Open Outlet Breakout Max. Power/W 1 63 Sound power levels dB re 1pW Max. Power/W 1 Curve Frequency/Hz Open Inlet -8 -10 -9 -10 -22 -24 -16 -13 Open Outlet -11 -10 -9 -14 -23 -26 -20 -15 Breakout 0 0 0 0 0 0 0 0 Open Inlet -4 -7 -5 -6 -7 -7 -6 -4 Open Outlet -8 -5 -4 -7 -7 -7 -6 -6 Breakout 0 0 0 0 0 0 0 0 Open Inlet -12 -20 -15 -16 -22 -24 -19 -16 Open Outlet -18 -18 -18 -25 -30 -35 -28 -26 Breakout 0 0 0 0 0 0 0 0 37 Technical DIMENSIONS (mm) for WM2 unit 605 SIL-WM2 TOP VIEW = SIDE VIEW = = Ø125 = 172 CRS 353 445 417 CRS 400 FF-WM2 = = = = FRONT/REAR VIEW 204 x 60 670 TOP VIEW 110 417 CRS = = = = = 242 CRS 172 CRS Ø125 220 489 97 = SIDE VIEW FACE TO BE MOUNTED NEAREST TO WALL COMPLETED SYSTEM CROSS BRACE = = 1001 ADJUSTABLE FEET ANGLE BRACKET 626 66 519 834 979 461 Wall Mounting Bracket 167 30 SIDE VIEW TOP VIEW WALL/SOLID STRUCTURE 15 Consultants Specification SIL- WM2 OPERATION The unit offers the facility to be fitted directly to the MVHR unit and plenum chamber without the need for spigots reducing breakout noise. However, there is the capability to fit 125mm circular spigots as an alternative option. The supply and extract ventilation unit shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. This unit is also available in Opposite Hand formatting. The unit shall be fully lined with acoustic material offering excellent noise reduction. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c, kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The extracted air shall also be filtered before it reaches the heat exchanger block. Wall mounting brackets are to be supplied as part of the system to allow the MVHR unit to be raised after other system components are installed to form an airtight seal and enable the installation to be levelled. The unit shall be clamped to the MRXBOX95(AB)-WM2 unit to provide an efficient seal and ensure correct alignment. The unit shall be fixed in position during installation as a standalone section without relying on other system elements. FF-WM2 The unit shall be supplied with 204mm x 60mm rectangular spigots to connect to the duct run, with the ability to be fitted in eight separate positions reducing the requirement for bends in the system. The unit offers the facility to be fitted directly to the mating sections without the need for spigots reducing breakout noise, additional 125mm circular spigots to be supplied as an alternative option. TECHNICAL DATA Units shall be one of MRXBOX95AB-WM2, MRXBOX95-WM2, MRXBOX95AB-WM2-OH, MRXBOX95-WM2-OH as manufactured by Nuaire. SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 95%. The heat exchanger shall be protected by G3 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency EC fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40°C. The unit shall be supplied complete with a condensate drip tray and 21.5mm drain connection. The unit shall be suitable for 125mm diameter circular ducting. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. The unit shall be offered with a 5 year warranty. 16 The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from the switched live signal from light/ remote switches or any ancillary sensors. When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. INTEGRAL AUTOMATIC SUMMER BYPASS (MRXBOX95AB-WM2 & MRXBOX95AB-WM2-OH only) Including Automatic SUMMER BYPASS where intake and return air temperatures shall be measured so that supply air temperatures can be maximised during winter months and minimised as external ambient temperature rises. The Summer Bypass damper shall be opened by a wax actuator. Supply and Extract air shall be filtered irrespective of the bypass setting (open or closed). CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components prewired and factory fitted by the manufacturer: • Independent control of background supply and extract flow rates • Independent control of boost speed supply and extract flow rates • Integral fan failure indication • Integral S/L terminal for boost from remote switch, e.g. light switch, kitchen boost switch • Integral heat exchanger frost protection • Discreet daily run monitor. • Integral humidistat. OPTIONAL CONTROLS MRXBOX95-RFI Remote fail indicator. MRXBOX95-PIR (Passive Infra-Red) A low voltage sensor which detects movement and activates system. MRXBOX95-HUM A low voltage sensor which activates the system when the relative humidity level is above a set point. MRXBOX-VSC An LCD controller for MVHR system with a 3.2” touch screen display.
© Copyright 2024 Paperzz