SERIES Luminary solution for Street lighting From 1,100 lm up to 27,300 lm The E LUM LED light is a high-tech light, which can be used for lighting of all kinds of streets, parking lots as well as other public and private outdoor areas. The modern, extremely thin aerodynamic design integrates very well into urban space. It is made of modern high-tech materials, which are tested in the automotive and medical industry. The modular concept enables a fast and efficient upgrade of the light with more efficient components as well as an ecological degradation after the end of its lifetime. The upper supporting part of the light and the rotor are made of a qualitative lightweight aluminium. They are protected by a thin powder coating, which ensures the protection of metal against oxidation even in the harshest weather and climate conditions. The lower cover is made of qualitative ASA plastic, which is known for its long lifetime in environments with fast, frequent and significant changes in temperature. The light is designed in such way that it ensures natural air circulation and therefore exceptional heat transfer, which is very important for a long lifetime. The surface that is big enough and is a result of the cooling fins on the upper part of the light enables an excellent heat transfer also at high ambient temperatures greater than 50°C. With the help of the FIPFG (“formed-in-place”) technology that guarantees the formation of the seal on the sealing spot we have achieved a high permanent IP66 protection which does not yield, not even in case of possible upgrade work on the light. ELUM | technical information Separated LED and powering part ASA plastic, UV-resistant Easy access for maintenance Valve against clouded glass and lenses Horizontal bottom surface against light pollution Coating against dazzling Scale for tilting angle adjustment Anti glare glass Stainless steel screws Safe fixing to a pole with four screws Integrated foam seal Easily adjustable angle 0-90⁰ Powder coating Various optics Thermal conductive foil Self-cleaning profile Aerodynamic design Big surface for heat transfer 2 High-pressure injected AL LUMINARY configuration E LUM series offers you three different packages. With these three variations, you can chose optimal products according to your requirements and price level. E LUM SERIES ECONOMY STANDARD PREMIUM - efficacy up to 96 lm/W - efficacy up to 112 lm/W - overheat protection - power reduction; flexible luminous flux - time-dependent luminous flux controll - constant luminous flux-CLO - multiple optics - different CCT avaliable - Control: DALI, 1-10 V, RF - optional surge protection - efficacy up to 125 lm/W - overheat protection - power reduction; flexible luminous flux - time-dependent luminous flux controll - constant luminous flux-CLO - multiple optics - different CCT avaliable - Control: DALI, 1-10 V, RF - C LUM controll - Surge protection SERIES E LUM 1 E LUM 2 E LUM ECONOMY E LUM STANDARD E LUM PREMIUM LED POWER [W] LIGHT FLUX UP TO [lm] POWER [W] LIGHT FLUX UP TO [lm] POWER [W] LIGHT FLUX UP TO [lm] 8 15 1,450 15 1,450 10 1,100 12 30 2,850 15 - 30 2,850 15 - 30 1,800 - 3,315 24 60 6,000 30 - 80 3,300 - 8,400 30 - 80 3,300 - 8,400 48 / / 80 - 120 8,490 - 11,450 80 - 120 9,600 - 14,000 64 / / 80 - 140 / 100 - 140 12,500 - 16,780 80 / / 95 - 140 10,500 - 14,900 95 - 140 12,000 - 17,000 96 / / 160 - 190 16,940 - 19,350 160 - 220 18,400 - 27,300 3 OPTIC Koda Ime Koda Ime Since we are aware of the fact that a safe and qualitative light distribution requires a secondary lens, we have paid special attention to this component. We enable a wide selection of different optics to reach an optimal light distribution in each case. The lenses are made of pmma, a material that is UV-resistant and does not turn yellow throughout its whole lifetime. Special glass neutralizes the glare effect and protects the lenses against harmful environmental impacts, which can be the result of exhaust gases, sand storms in the desert, acid rain and vandalism. The inner part of the light is composed of colour shades that guarantee the highest recuperation of light, which reflects from the glass. With the Gore-Tex valve, we ensure the air exchange, which is very important for preventing the condensation effect without threatening the IP protection. 32.080.000 ELUM Koda Ime 32.080.001 ELUM LRF 2013/018 ELUM Koda Ime LRF 2013/014 ELUM Tok naprave 7114.46 lm Moč svetila Sve. tok sijalke 7115.00 lm Maksimalna vrednost 891.81 cd/klm 80.00 W Učinkovitost Pozicija 88.93 lm/W C=30.00 G=42.50 840mm x 400mm Izkoristek Tok naprave 99.99% 6533.01 lm Moč svetila CG Asimetrična Sve. tok sijalke 6535.00 lm Maksimalna vrednost 481.33 cd/klm Polravnina C 90 76.90 W Učinkovitost Pozicija 84.95 lm/W 180.0 0.0 270.0 90.0 99.97% CG Asimetrična Polravnina C 90 0 Izkoristek C=150.00 G=62.50 840mm x 400mm 180.0 0.0 270.0 90.0 90 180 270 270 105° 105° 90° 90° 75° 75° 60° 60° 90° 150 75° 300 60° 180° 120° 150 105° 120° 80 105° 105° 90° 90° 75° 75° 60° 60° 80 160 450 180° 150 240 48.080.100 ELUM Koda Ime ELUM 48.80.101 ELUM2 Koda 45° Ime LRF 2013/016 45° ELUM Koda 45° Ime ELUM2 45°48_80_101 ELUM2 80.00 W 600 Moč svetila Maksimalna vrednost 578.02 cd/klm Učinkovitost Pozicija 91.86 lm/W C=15.00 G=65.00 840mm x 400mm Polravnina C 750 30° 90 15° 180.0 15° 270.0 0° 8031.53 lm Moč svetila Sve. tok sijalke CG Asimetrična 8032.00 lm Maksimalna vrednost 971.58 cd/klm 30° 90.0 OPTICS 000; Suitable for high Installation, bigger distance between poles and parking spaces. (c)OxyTech Srl 180 www.oxytech.it LITESTAR 48.120.110 ELUM2 Koda Ime ELUM2 48 ELUM2 Tok naprave 45° Sve. tok sijalke Moč svetila 11760.00 lm Maksimalna vrednost 424.37 cd/klm 120.00 W 600 Učinkovitost Pozicija 97.99 lm/W C=60.00 G=65.00 30° 90.0 90° 90° 75° 75° 60° 60° 250 500 Polravnina C 15° 0° Izkoristek 99.99% 270.0 99.99% CG Asimetrična cd/klm 0.0 15° 30° 90.0 OPTICS 002; Suitable for narrower roadways, access roads, cycling and pedestrian areas. 0 Stran 1 180 270 180° 105° 105° 90° 90° 75° 75° 60° 60° 45° 45° 120° 250 105° 90° 250 75° 500 60° 750 45° 45° Izkoristek 180.0 90 120° 250 100.37 lm/W C=90.00 G=47.50 45° 1000 1000 CG Asimetrična Polravnina C 15° cd/klm0.0 180.0 750 90 270.0 15° 0° 30° 30° 0 OPTICS 010; Suitable for bigger distance between poles and high mounting installation. Higher uniformity factor. (c)OxyTech Srl www.oxytech.it LITESTAR 0° 15° 30° OPTICS 100; Suitable for parking spaces and pedestrian crossing. cd/klm 1250 30° LITESTAR 15° 0° 15° 30° OPTICS 101; Suitable for parking spaces. Small distance between poles. Stran 1 (c)OxyTech Srl www.oxytech.it Stran 1 120° 150 105° 15° (c)OxyTech Srl www.oxytech.it Stran 1 270 180° cd/klm 1250 90.0 180 LITESTAR 30° Pozicija 750 0.0 15° 270.0 Učinkovitost 970mm x 400mm cd/klm 180.0 80.00 W 750 970mm x 400mm 30° Maksimalna vrednost 988.39 cd/klm 180° 450 11759.10 lm Moč svetila 8030.00 lm OPTICS 001; Suitable for wider roadways and smaller distance between poles and parking spaces. 105° 300 Koda Ime 0° 8029.45 lm CG Asimetrična Sve. tok sijalke Stran (c)OxyTech 1 Srl 180 www.oxytech.it 105° 150 60° 15° 120° 90° 75° 90 45° 600 IzkoristekTok naprave99.99% 270 150 105° 104.71 lm/W C=0.00 G=0.00 0 270 180° Pozicija Polravnina C 400 0.0 30° Učinkovitost 840mm x 400mm cd/klm 0 LITESTAR 76.70 W 320 Izkoristek Tok naprave 99.99% 60° 450 Koda Ime LRF45° 2012/019 ELUM 32.080.010 7350.00 lm 75° 300 32.080.010 ELUM 32.080.010 7348.93 lm 105° 90° Koda Ime Sve. tok sijalke 120° 150 Koda Ime Tok naprave 90.0 180 270 180° 0.0 270.0 0 0 180 180.0 105° 90° 90° 150 75° 75° 300 60° 60° 450 45° 45° 600 LITESTAR 4 15° With tuneable lumen package, tilt adjustment and wide range of optics E LUM can match the variety of ME/ S lighting classes and road/street geometries individually. cd/klm 750 30° 0° 15° 30° OPTICS 110; Suitable for wide roadways, parking spaces. Smaller distance between poles. (c)OxyTech Srl www.oxytech.it Stran 1 Lighting classes S1 S2 S3 S4 S5 S6 E LUM 1 1,100 lm – 8,000 lm x x x x x x E LUM 2 8,000 lm – 24,000 lm x x ME1 ME2 x x ME3a x ME3b ME3c ME4a ME4b ME5 ME6 x x x x x x x x x x x x E LUM FEATURES EATURES CLO - CONSTANT LIGHT OUTPUT ight Output All light sources experience lumen depreciation - a reduction in light output over time. To ensure the minimum levels in an installation, periencerequired lumenlightdepreciation - a most lighting designs are calculated based on the light level at the end of the lamp’s useful life (normally the L70 utput over time. To ensure thepoint: 70% of the initial lumens). This means that the system consumes more power than necessary, wasting, on average, as much as 15% of energy during its lifetime. The Constant Light Output ght levels in an installation, most (CLO) functionality compensates calculated based on the light level for this light loss, ensuring that on - a both HID lamps and LEDs will useful re thelife (normally the L70 point: always deliver the necessary light mens). , mostThismeans that the system level. By taking into account the wer than necessary, wasting as lumen depreciation, the driver t level can be programmed to start at a rgy on average during its lifetime. point: dimmed level for a new luminaire ht Output (CLO) functionality ystem and gradually increase power over light loss, ensuring that both HID ng as the life of the light source, saving always deliver the necessary light level. By taking into account the lumen the energy and depreciation, extending the lifetime of etime. system. power over the mmed onalityto start at a dimmed level for a new luminaire and graduallytheincrease e, saving th HID energy and extending the lifetime of the system. light level. By taking into account the lumen depreciation, the functionality nctionality evel for aDYNADIMMER newprovides luminairemulti-step and gradually increase power over the provides multi-step dimming. The nation of five flexible dim periods ing the lifetime of the system. combination of five flexible dim es it easyperiods to customize a virtually and dim levels makes it mming Any level can be easy to customize a virtually endless ti-step profiles. of dimming Any level duration,arraymaking it profiles. possible to eriods can be configured for any duration, t levels in the middle of the night, rtually making it possible to provide very times and anything in middle between levels in the of the an be low light onal periods. All Dynadimmer night, high levels at peak times and ble to anything in on between during the dnight, on the system’s and off times. transitional periods. All Dynadimmer f the dimming schedule can be tween schedules work based on the system’s on and off times. The configuration of the dimming schedule can be done or even after products have been installed. before,the during or even after the products have been installed. mmer times. MODULE TEMPERATURE PROTECTION manages an be excessive of the LED PCBOR board. V CONTINUOUS DIMMING VIAtemperatures ANALOG CONTROL SIGNAL DALIHigh ave been1-10 installed. negatively impacts the1-10 useful life aofminimum the LEDs, and The 100% light level is determined byheat the output current level of the driver. V allows dim level of 10% subject to the absolute minimumincreases current possible for each driver. When dimming via integrated Dynadimmer, maintenance costs. MTP feature manages MODULE TEMPERATURE PROTECTION manages 1-10 V can be used to override the Dynadimmer schedule whenever necessary (e.g. via central switch or presence PCB temperature by regulating the output current of excessive ofapplication the LED PCB board. detector; seetemperatures Dynadimmer override note). Diming is alsoHigh possible via DALI command lines, according driver. When the LED to technical standardimpacts IEC 62386.thethe heat negatively useful life of the LEDs, andboard temperature rises to a critical level, themanages MTP will first dim down and then increases maintenance costs. MTP feature completely turn current off the light PCB temperature by regulating the output of engine. The system will be turned back on rises whentothe LEDs cool down below the driver. When the LED board temperature P protects LED life during or temporary a critical level, the occasional MTP will first dim downheat and spikes, then e.g. a sunny day with the hed off.completely turn off the light engine. The system will be turned back on when the LEDs cool down below uS dimming Via anaLOg COntrOL ccasional or temporary heat spikes, e.g. aSignaL sunny day with the l is determined by the output current level of the driver. 1-10V allows a minimum dim 5 provide very low light levels in the middle of the night, high levels at peak times and anything in between during the transitional periods. All Dynadimmer schedules work based on the system’s on and off times. MODULE TEMPERATURE PROTECTION excessive temperatures of the can LED PCB The configurationmanages of the dimming schedule be board. High heat negatively affects the useful life of the LEDs, and increases maintenance costs. MTP feature done before, during or even after the products have been install manages PCB temperature by regulating the output current of the driver. When the LED board temperature rises to a critical level, the MTP will first dim down and then completely turn off the light engine. The system will be turned back on when the LEDs cool down below the critical level. MTP protects LED life during occasional or temporary heat spikes, e.g. a sunny day with the installation not switched off. MODUL excessiv heat neg increase PCB tem the driv a critica complet be turne E LUM ACCESSORIES the critical level. MTP protects LED life during occasional or tem installation not switched off. SPD LED street lighting is now widely used for its efficiency, energy cost savings and life expectancy. Nevertheless, this attractive technology has an important weakness: its sensitivity to 1-10V COntinuOuS dimming Via anaLOg COntrOL S transient voltageslight created by lightning or by power switch operations AC The 100% level is determined by the outputon current leve network. Due to its scattered and over-exposed location, LED lighting system level of 10% subject to the absolute minimum current possible will face induced surges which will create failure of its power supply, damage 1-10 be used to override the Dynadimmer of Dynadimmer, LED components or loss V of can the lighting efficiency. For these reasons, the use of relevant surge protectors located upstream the LED lighting systems applicati switch or presence detector; see Dynadimmer override is highly recommended. LUMENIA provides a set of surge protectors to be installed at different locations of the outdoor lighting network, such as the DALI is the acronym for Digital Addressable Lighting Interfac luminaires, street lighting pole box and street cabinets. lighting management system that provides maximum control an DALI is not a single feature. It is a standard industry protoc (ballasts, control systems, sensors, controllers, switches, etc.) f C LUM matched together seamlessly into complete systems. With DA C LUM enables remote control and improved vs. conventional, proprietary systems. monitoring of lights to reduce energy and maintenance costs. C LUM is an integrated solution-level wireless system that is easy to implement into E LUM lamps fitted with dimming control. A C LUM RF module is fitted to each lamp and communicates via C-Net, a sub 1 GHz mesh network. The C LUM enables lamps to connect to a Data Concentrator Unit (DCU) to support the two way communication to lamps via the Lighting Server, controlled from WebView, a Graphical User Interface. In addition to C LUM solution, Lumenia Smart Street Lighting Control (SSLC) system enaibles management of street lighting with help of Power Line Communication (PLC) through the existing power cable connections. 18 6 Nema socket and ligHt sensor PRODUCT DETAILS: Light-Control Sensors Photocell Sensors For Lamp SPECIFICATIONS: Power Source: 110 - 240 V/AC Rated Load: 10 A Power Frequency: 50/60 Hz Ambient Light: < 5 lux - 15 lux TECHNICAL DATA Lifetime L80B10 > 65,000 hours (Economy & Standard E LUM) L80B10 > 300,000 hours (Premium E LUM) Operating temperature -40°C +55°C Supply voltage 220 – 240 Vac 50 ÷ 60 Hz Electrical power E LUM 1: from 15 to 80 W E LUM 2: from 80 to 220 W Power factor > 0.96 CCT 4,000 – 4,500 K; 4 Step McAdam (6,000 K or 3,800 K upon request) Factor of colour rendering (CRI): ≥ 70 Surge protection 4 kV (class II); 10 kV (class I) Max. area exposed to the wind E LUM 1: 0,0552 m² E LUM 2: 0,0862 m² Protection class IP 66; IK 09 Certificates IEC 60529:2001; EN 60598-1 :2008, cI.9.2.2 and 9.2.7; IEC 60598-2-3 (Third edition):2002 + A1:2011 used in conjunction with IEC 60598-1 (Seventh edition): 2008; IEC 6059826:1994+A1:1996 used in conjunction with IEC 60598-1:2008; EC 62031:2008 (First edition); CE; ENEC; ZIK Guarantee 10 years on mechanical and 5 years on electrical parts Wireless control optional Installation height 3.5 to 16 meters Dimensions E LUM 1 E LUM 2 7 INSTALLATION The rotor enables a direct installation from the side or on the top of the pole (90°), with possible regulation of the light angle 0 - 90° with the step of ± 5° (for poles or bearers with 60 mm in outer diameter). The security system inside the rotor prevents from an unintentional tilt during the regulation phase and a possible damage that could occur during the disassembly or installation of the light. Special attention was paid to the mounting of the light to the pole, since it is mounted with four screws, according to the strictest international rules and recommendations. LUMENIA d.o.o., Breg pri Litiji 50, 1270 Litija, Slovenia, Europe [email protected] www.lumenia.com tel: +386 1 890 00 57 February 2016 Mounting pole: Ф60 mm (possible adapter use for other dimensions) Tilt: 0 - 90°, step ± 5° Weight: E LUM 1: 7 kg; E LUM 2: 15 kg
© Copyright 2026 Paperzz