The Commission Decision 2002/657/EC Performance criteria by Dr. Michael Scheutwinkel International Federation for Consulting GmbH IFC 1 Content of Annex of CD 2002/657/EC 11 Definitions 2 Performance criteria and other requirements for analytical methods 2 2.1 General criteria to be fulfilled by any technique, procedure, etc. 2.2 Criteria for screening methods 2.3 Criteria for confirmatory methods (organics) 2.4 Criteria for confirmatory methods (elements) 3 3 Recommended valdidation procedures - classical validation - alternative validations, e.g. InterVal 2 Performance criteria according to CD 2002/657/EC 2.1 General requirements 2 1 Sample handling Test performance Maximum chance for the detection of the analyte Recovery with each batch of samples Specifity 3 Commission Decision 2002/657/EC 4 Performance criteria according to CD 2002/657/EC 2.2 Screening methods False compliant rate < 5 % (β-error) In case of a suspected non-compliant result, a confirmation is obligatory. 5 Suitable confirmatory methods according to Table 1 CD 2002/657/EC, here only extract Substances Annex I 96/23/EEC Limitations LC or GC with MS Groups A and B - Only if following either an on-line or offline chromatographic separation - Only if full scan technique are used or using at least 3 (group B) or 4 (group A) identification points for techniques that do not record the full mass spectra LC-full-scan DAD Group B Specific requirements for absorption in UV spectrometry have to be met Measuring technique Others ----6 Commission Decision 2002/657/EC Table 9 7 Commission Decision 2002/657/EC Table 10 8 Performance criteria according to CD 2002/657/EC 2.3 Confirmatory methods for analysis of organics, common requirements 1 No discrimination in cases that two compounds give same response, only chromatographic analysis without spectrometric detection is not appropriate. 3 Use of internal standard or confirmation by co-chromatogaphy 3 Use of CRM or fortification of material 9 Performance criteria according to CD 2002/657/EC 2.3 Confirmatory methods for analysis of organics, specific requirements 1 2 Minimum trueness (Table 2) Reproducibility CV(%) (Table 3) CV = interlaboratory coefficient of variation in % MRL existing? CV = 50% of limit 10 Commission Decision 2002/657/EC Table 3 11 Commission Decision 2002/657/EC Table 2 12 Commission Decision 2002/657/EC 13 Performance criteria according to CD 2002/657/EC Confirmatory methods for analysis of organics, performance criteria for MS Chromatographic separation MS detection Usually full scan, < 10% deviation from reference MS Full scan + SIM see table 4 SIM S/N ratio > 3:1 14 Commission Decision 2002/657/EC 15 Commission Decision 2002/657/EC 16 2.3 Confirmatory methods for organics, performance criteria Chromatography coupled to infrared detection LC with different detection techniques GC-ECD 2-D TLC coupled to full-scan UV/VIS spectrometric detection 17 Commission Decision 2002/657/EC 18 Commission Decision 2002/657/EC 19 Commission Decision 2002/657/EC Table 5 20 Commission Decision 2002/657/EC Table 6 21 Performance criteria according to CD 2002/657/EC Table 4 22 Commission Decision 2002/657/EC Table 6 23 Commission Decision 2002/657/EC 24 Commission Decision 2002/657/EC 25 2.4 Confirmatory methods for elements, see also table 7 Trueness of quantitative tests Differential pulse anodic strippingvoltametry AAS ICP-AES ICP-MS 26 Commission Decision 2002/657/EC Table 7 27 Commission Decision 2002/657/EC Table 8 28
© Copyright 2026 Paperzz