© KROHNE 01/2005 7.02309.24.00 GR All-metal miniature flowmeters DK 32/34 Subject to change without notice. Electromagnetic flowmeters Variable area flowmeters Mass flowmeters Ultrasonic flowmeters Vortex flowmeters Flow controllers Level measuring instruments Pressure and temperature Heat metering Communications technology Switches, counters, displays and recorders Engineering systems & solutions All-metal miniature flowmeters DK 32/34 DK 32 and DK 34 variable-area flowmeters are rugged all-metal flowmeters suitable for a wide variety of applications. Metal cone Stainless steel block, upper and lower Mechanical indicator Calibrated to VDI Code 3513 Fine adjusting valve (DK 32 only) DK 32 with horizontal connections and valve Options ● Valve in upper device block. ● Max. two adjustable limit switches (K1/K2), set limit values are indicated on the scale. ● Connection of a differential-pressure regulator is possible. DK 34 with vertical connections, without valve Option ● 2 Max. two adjustable limit switches (K1/K2), set limit values are indicated on the scale. DK 32 / DK 34 The responsibility as to the suitability, intended use and corrosion-resistance of the materials used in their construction rests solely with the purchaser. Technical data Accuracy class 4 to VDI/VDE Guideline 3513, Sh. 2 Scale division in flow units Max. allowable operating pressure PS 130 bar (1885 psig) (higher pressure levels on request) Directive 97/23/EC of the Council of 29 April 1999 concerning transportable pressure equipment (Pressure Equipment Directive) is applied. The max. allowable operating pressure PS is calculated for the max. allowable operating temperature TS. Both limits (PS and TS) are indicated on the nameplate. As a rule, PS is equivalent to the nominal pressure of the connection. Test pressure PT The test pressure is calculated in accordance with the Pressure Equipment Directive (97/23/EC) and AD 2000-HP30 with due regard to the maximum allowable operating pressure and the maximum operating temperature. Degree of protection to EN 60529 / IEC 60529 IP 65 Process temperature Max. process temperature TS, without contacts – 80°C to +150°C (–112°F to +302°F) Ambient temperature Tamb. – 20°C to +70°C (–4°F to +158°F) Version with contacts Process temperature Tamb < 40°C (< 104°F) Tamb < 50°C (< 122°F) Tamb < 60°C (< 140°F) DK32/K, DK34/K 145°C 293°F 135°C 275°F 125°C 257°F Other temperatures on request Connections 1/4” NPT female thread Standard Adapters Ermeto 6 or 8, Serto 6 or 8, Dilo, Gyrolok, Swagelok, G 1/4 Materials Top and bottom blocks, cone, upper plug CrNi steel, 1.4404 / 316 L Float CrNi steel 1.4571, titanium Valve CrNi steel 1.4571 Plug gasket Viton Gasket for dosing unit Viton and PTFE Housing die-cast aluminium Limit switches Type SC 2-N0 Max. number 2 Electrical connection right-angle plug, style to DIN 43650/ISO 4400, with cable gland M12 x 1.5 Length of signalling cable 1.5m, permanently wired Degree of protection to EN 60529/IEC 529 IP 65 DK 32 / DK 34 3 DK 32 / DK 34 Flow table Reference conditions Water at 20°C (68°F) Air at 20°C, 1.013 bar abs. (68°F, 14.7 psia) 100% Flow values, Turn-down ratio 10 : 1 Cone No. Valve spindle diameter mm inches Ident No. K 005 K7 K 010 K5 K 015 K9 K 040 K4 K 080 K1 K 125 K2 K 200 K3 K 300 K6 K 340 K8 * with titanium float 1.0 1.0 2.5 2.5 2.5 4.5 4.5 4.5 4.5 Water 0.059 0.059 0.059 0.126 0.126 0.126 0.126 0.126 0.177 Air max. pressure loss l/h US GPM l/h SCFM mbar psig – – 0.013 0.022 0.044 0.110 0.176 0.264 0.352 0.440 50/16* 100 150 400 800 1250 2000 2500 3400 0.031 0.062 0.093 0.248 0.496 0.775 1.241 1.551 2.109 31 66 19 27 55 42 85 117 166 0.45 0.96 0.28 0.39 0.80 0.61 1.23 1.70 2.41 3 5 10 25 40 60 80 100 Dimensions and weights 55 (2.17”) 110 (4.33) 90 (3.54”) 125 (4.92”) 35 (1.38”) 25 (0.98”) 45 (1.77”) 42 (1.65”) Weight DK 32 approx. 0.7 kg (1.5 lbs) 30 45 (1.18”) (1.77”) Weight DK 34 approx. 0.6 kg (1.3 lbs) Dimensions DK with limit switches Note If several devices are installed side by side, please observe given lateral dimensions. 1500 (50.1”) app. 90 (3.54”) (3.54”) (1.97”) app. 90 46 (1.81”) To be able to set the limit contacts, cover screws must be detachable. app. 50 app. 44 (1.73”) 4 DK 32 / DK 34 DK 32 / DK 34 Needle valves for gases and liquids Needle valves allow exact setting of the flow rate. Valve stem Max. flow rate Qv Water l/h 5 50 160 240 Ø mm 1.0 2.5 4.5 6.0 Max. flow rate Qv Air l/h 100 1000 4300 7000 Cv valve characteristic m3/h 0.018 0.15 0.48 0.62 Valve characteristic Air l/h Valve stem 1,0 mm Water Water l/h Air l/h Water Air Air Stem turns n Stem turns n Air l/h Valve stem 4,5 mm Water Water l/h Air l/h Valve stem 6,0 mm Water l/h Air Water Stem turns n Water l/h Valve stem 2,5 mm Air Stem turns n DK 32 / DK 34 5 DK 32 / DK 34 Range of application Differential pressure regulators Differential pressure regulators are used to maintain constant flow rates Inlet pressure regulators, type RE, NRE Types RE and NRE maintain a constant flow rate for gases and liquids at varying inlet or outlet pressures. at variable inlet pressures and constant outlet pressures. ● Minimum pressure levels are required for operation of the regulators Example: inlet pressure regulator RE 1000: (see regulator characteristics) Current flow rate: 1000 Nl air ● Differential pressure regulators are not pressuring reducing valves Outlet pressure constant: 1.013 bar abs. At a variable inlet pressure greater than 0.5 bar, the flow rate in the ● Maximum flow rate: 3400 I/h (2.11 SCFM) air device remains constant. 100 I/h (0.44 US GPM) water. ● Connections: standard: 1/4" NPT special version: Serto 6 or 8, tube grommets 6 or 8 mm, Ermeto 6 or 8, Dilo, Gyrolok, Swagelok ● Max. allowable operating pressure at 20°C (68°F): CrNi steel 1.4404 max. 64 bar (928 psig) ● Temperatures up to max. 80°C (176°F) Outlet pressure regulators, type RA, NRA On gas service, types RA and NRA maintain a constant flow rate at variable outlet pressures and constant inlet pressures. There must be a minimum pressure difference between inlet and outlet pressure in order for the outlet pressure regulator to function. Example: outlet pressure regulator NRA 800: current flow rate: 800 Nl air inlet pressure constant: 3 bar At a variable outlet pressure of 0 … 2.9 bar, the flow rate in the device remains constant. Differential pressure regulators Type Inlet pressure regulator RE-1000 RE-4300 NRE-100 NRE-800 Max. flow rate Water * l/h US GPM 40 0.18 100 0.44 2.5 0.011 25 0.11 Air * l/h 1000 3400 100 800 Min. required inlet pressure p1 bar psig 0.5 7.25 1-2 14.5 - 29.0 0.1 1.45 0.2 - 0.4 2.9 - 5.8 SCFM 0.62 2.11 0.062 0.50 Min. pressure difference ∆p (inlet/outlet pressure) 0.5 7.25 2.0 29.0 0.4 5.80 Outlet pressure regulator RA-1000 40 0.18 1000 0.62 RA-4300 100 0.44 3400 2.11 NRA-800 25 0.11 800 0.50 * Reference conditions: air 20°C (68°F), 1.013 bar abs. (14.7 psia) water 20°C (68°F) Material: CrNi steel 1.4404 Regulator characteristics Inlet pressure regulator types RE and NRE l/h (SCFM) l/h (SCFM) 5000 (3.1) 4000 (2.48) 4000 (2.48) qv qv 3000 (1.86) 3000 (1.86) 2000 (1.24) 2000 (1.24) 1000 (0.62) 1000 (0.62) 0 1 (14.50) 2 (29.01) 3 (43.51) 4 (58.02) 5 (72.52) 6 (87.00) p1 = inlet pressure in bar (psig) Qv = Current flow rate 6 5000 (3.1) DK 32 / DK 34 0 1 (14.50) 2 (29.01) 3 (43.51) 4 (58.02) 5 (72.52) p2 = outlet pressure in bar (psig) 6 (87.00) DK 32 / DK 34 app. 163 (6.42”) Dimensions, differential pressure regulators Inlet pressure regulator RE, NRE (2.76”) (0.75”) (0.59”) (0.59”) 1/4” NPT 70 (RE, NRE, RA, NRA) Inlet always at bottom app. 15 19 1/4” NPT app. 15 90 (3.54”) Limit switches Limit switch SC 2-NO is a slot sensor with built in preamplifier. The sensor is actuated by the dipping action of the pointer vane. The limit switches can be set over the entire measuring range. The set limit values are indicated on the scale. For hazardous-duty systems, SC 2-NO contacts are connected to isolation switching amplifiers. Isolation switching amplifier NAMUR KFA6-SR2-Ex1.W KFA5-SR2-Ex1.W KFD2-SR2-Ex1.W KFA6-SR2-Ex2.W KFA5-SR2-Ex2.W KFD2-SR2-Ex2.W Power supply 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC Technical data, SC 2-NO Nominal voltage Current consumption, active area clear active area obscured 8 V DC 3 mA 1 mA For use in hazardous aeas, note that connection of the limit switch to the intrinsically safe circuits must be made with following maximum values Version DK3./....././....-EEx No-load voltage Ui Short-circuit current Ii Power Pi 16 V 52 mA 169 mW Channel 1 1 1 2 2 2 Version DK3./....././..../ A - EEx No-load voltage Ui Short-circuit current Ii Power Pi Order No. 5015262000 5015262100 5015262200 5015262300 5015262400 5015262500 16 V 25 mA 64 mW Independent of the built-in variant, the following maximum values apply: Self-inductance (Li) 150 µH Self-capacitance (Ci) 150 nF General approval DK3./....././..-EEx: Approval SC......: PTB 99 ATEX 2191 PTB 99 ATEX 2219 X DK 32 / DK 34 7
© Copyright 2026 Paperzz