LOCAL GOVERNMENT ASSOCIATION CONFERENCE OF QUEENSLAND ENVIRONMENT CONFERENCE Working Smarter on Natural Challenges COFFS HARBOUR’S ENERGY EFFICIENT STREET LIGHTING PROJECT Jeff Green - Environmental Services Manager Estimated Corporate Emissions by Sector 1995-2010 1995 2010 3000 2000 1000 Wa ste Wa ter /S ew ag e Str ee tl ig h ts le F -2000 Ve h ic -1000 lee t 0 Bu i ld i ng s Tonnes eq. Co2 4000 Se ctor STREET LIGHT AUDUT Coffs Harbour Local Government Area Street Lights 369 57 Fluorescent Mercury Vapour High Pressure Sodium 3013 Lumens/Mortality TECHNOLOGY LAMP SIZE 50% SPOT LUMENS NO. AV LIFE (100Hr) LAMPS Lumens/ Watt T5 FLUORESCENT T5 FLUORESCENT 14 24 2700 3500 2 2 96 73 4.8 4.8 COMPACT FLUORESCENT COMPACT FLUORESCENT 42 57 3200 4300 1 1 76 75 2.4 2.4 50 50 50 50 70 70 70 3600 4400 3600 4000 5800 5600 5800 1 1 1 1 1 1 1 72 88 72 80 83 80 83 6.2 6.7 11.4 11.4 6.2 6.7 11.4 METAL HALIDE 70 5200 1 74 2.5 MERCURY VAPOUR 80 3800 1 48 4.3 HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM - STANDARD - SUPER 4Y - TWIN ARC - TS TWIN ARC - STANDARD - SUPER 4Y - TWIN ARC Lumen Depreciation Street Light Project Objectives • Reduce street lighting energy use and greenhouse gas emissions • Improve street lighting performance and maintenance • Enhance understanding of community attitudes and support for the program • Develop financial models for street lighting alternatives. • Development Street Lighting Service Agreement. • Disseminate information Issues • • • • • • • • • • 160 different tariff rates and line items for Coffs. Safety and risk management Capital Cost of lamps, fittings and poles. Ownership of lights, poles and fittings Capital cost met by different parties Lumen Depreciation Many lights operating well below 70 % efficiency Lamp survival/mortality. Colour Rendering Sensor/timer problems. Issues • • • • • • • • • • • • • Contestable street light energy from 1 Jan 2001 Mandatory Benchmarks and Non renewable Greenhouse Abatement Certificates Compatibility of existing fittings Inefficiencies of lights due to spill, and spread where light not needed. Capital depreciation terms Replacement terms for fittings Light pollution Inadequate street light performance monitoring Street lights records - location, type and age Light characteristics – glare, illumination, distribution. Availability and cost of long life high efficiency lamps. Compliance with Australian Standards 1158.1.3 & 1158.3.1 Efficiency loss due to insects, dirt etc ® DULUX T/E 57w & 42w IN Compact fluorescent lamps with Amalgam technology for applications with high ambient temperatures. Design of the T5 Greenstreet Production Concept Optical system High Pressure Sodium 50-150W Super 50,000 hours at 50% Mortality High Pressure Sodium 50-150W Super STREET LIGHT PROGRAM ACTIVITIES • Audit of street lights - number, type, age, location • Evaluate lighting alternatives. • Street lighting trial in a residential area: – – – replace MV with HPS; replace MV with LPS; evaluate & survey residents. • Financial/Energy/Lumen modelling – – – – – – – – – Establish depreciated capital values; Calculate spot and bulk maintenance costs Management costs; Costs lamps, fittings, poles etc; Model capital eg loan, revised fees, one off payment, terms; Model terms for replacement progressive upgrading energy/greenhouse performance lighting performance STREET LIGHT PROGRAM ACTIVITIES • • • • Enhance street light GIS data. Develop software model Develop specifications Prepare Service Agreement for upgrading and servicing. • Prepare brochures and information • Program commences. Adelines Way, CH - Measured Lighting Improvements 80W Mercury Vapour to 35W Low Pressure Sodium Lux 12 10 8 6 4 2 0 80 MV prior to Cleaning 80 MV after cleaning Scenario After change to 35W LPS 8 Bray Street Measured Lighting Improvements 80 W Mercury Vapour to 50 W HPS Lux 6 4 2 0 80 MV prior to Cleaning 80 MV after cleaning Scenario After Installation of HPS 50W COMMUNITY PREFERENCES 14 12 Responses 10 8 6 4 2 0 New Lights Standard Lights No Preference Not noticed Street Lights Bray Street - MV 80 to 50 W HPS Adelines Way - MV 80 to 35W LPS Street Lighting Model - V11.05.04 - to Compare Lighting Costs and Greenhouse Savings July 1, 2004 INPUT FIELDS Select the Council locality to review OUTPUT FIELDS b) Typical Town - total Existing "Old Lighting" Lighting Population Annual Energy Use Annual GHG Emissions Energy/NEMMCO cost to Council Energy/NEMMCO cost to VicRoads Powercor OMR cost to Council Powercor OMR cost to VicRoads TotalOwnership Cost - Council TotalOwnership Cost -VicRoads Total Lighting Ownership Costs 9263 5609 8076.4 $405,542 $113,906 $307,888 $77,789 $713,430 $191,695 $905,125 mWh pa eCO2 tonnes $ pa $ pa $ pa $ pa $ pa $ pa $ pa New Lighting Scenario 1. Category V upgrade to HPS 2. Category P upgrade Yes Yes 3. Type of P lanterns to be replaced T5 4. Number of P Lanterns to be replaced? All 2*14W Annual Energy Use Annual GHG Emissions Energy/NEMMCO cost to Council Energy/NEMMCO cost to VicRoads TotalOwnership Cost - Council TotalOwnership Cost -VicRoads Total Lighting Ownership Costs Council Ownership Savings Vic Roads Ownership Savings Capital Total Upgrade Cost Upgrade Cost for Council lights Upgrade Costs for VicRoads Lights Interest on capital SEAV Contribution VicRoads Contribution to upgrade Council Contribution to upgrade Powercor Contribution Vic Roads simple payback period (no interest/growth) Council simple payback period (no interest/growth) 6.5 % 0.0% 3.3% 31.7% 65.0% Low Range $582,443 $167,656 $750,099 3438 4950 $221,819 $96,577 High Range $613,678 $167,656 $781,334 $130,987 $24,039 $99,752 $24,039 Low Range $2,259,336 $2,047,005 $212,331 High Range $2,571,686 $2,359,355 $212,331 $0 $74,316 $716,452 $1,468,568 3.09 yrs 5.47 yrs mWh pa eCO2 tonnes $ pa $ pa $ pa $ pa $ pa $0 $84,590 $815,500 $1,671,596 3.52 yrs 8.18 yrs Greenhouse Abatement Annual GHG Reductions 38.7% 3126.0 eCO2 tonnes Coffs Harbour Street Lights Annual Savings Retail Energy NUOS Capital Maintenance Total Ownership Greenhouse eCO2 tonnes $25121 $30909 $5242 $30815 $92098 644 Ownership savings to pay out residual capital of $400,000 STREET LIGHT PROGRAM $3,500,000 $3,000,000 $2,500,000 $2,000,000 $1,500,000 $1,000,000 $500,000 $0 0 1 2 3 4 5 6 7 Cumulative Savings 8 9 10 11 12 13 14 15 16 17 18 19 20 Years Residual Capital Net Profit What this means: COFFS HARBOUR • 35 % Energy Savings • 644 tonnes less CO2 per annum • 15% saving in street lighting costs Regional Councils NSW (Country Energy)• 24,000 tonnes less CO2 per annum • Savings to Councils of $3,000,000 per annum Steps to Introduce Energy Efficient Street Lighting • Obtain Network Providers Database for your Council area • Audit of physical assets against database • Examine lighting alternatives relative to your own area, and consider issues such as available technology, temperature, pole heights and spacing, crime, and travel distances. • Establish energy costs, maintenance costs, residual capital values and upgrade costs • Input data and variables into Model Steps to Introduce Energy Efficient Street Lighting • Calculate cost/benefits for new and old lighting scenarios. • Decide upon financing options for residual and new capital • Keep your council informed and take advantage of positive media opportunities • Investigate carbon trading • Document CCP Greenhouse Gas abatement for compliance with Goals and Milestones • Use savings – Greenpower, revolving funds.
© Copyright 2026 Paperzz