(Status PSB Acquisition Chain)

BWS Upgrade: Electro-Mechanical design meetin #14
Acquisition Chain Status
Jose Luis Sirvent Blasco
BE-BI-BL
BWS Upgrade: Electro-mechanical design Meeting #14
19/09/2016
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
1
1. Scintillators assembly Set-Up:
1.1 Components availability status
Component
#
Description
Status
Delivered
BC-408
5
Cylindrical scintillators
Ordered
21-Oct-2016
R9880U
2
Standard PSB PMTs
Lab. Available
Ready
E10679
2
PMT HV Base
Lab. Available?
(To check)
Ready
FilterWheel
3
See Next Slides
--
Work in
Progress
Fixed Filters
-
Kodak ND Filters
Lab Available
Ready
R7600U-M4
2
MaPMT (Test System)
Ordered
5-Oct-2016
E678-32B
2
MaPMT Socket
Ordered
5-Oct-2016
E7083
2
MaPMT HV Base
Ordered
26-Oct-2016
All ready on beginning of November
Scint
Waveguide
Waveguide
Scint
Filter Box
Filter Box
Fixed Filters
PMT
R9880
MaPMT
R7600
HV Base
E10679
HV Base
E7083
PSB Standard
Series
PSB Modif
Series
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
2
2. Filter wheel status:
2.1 ND Filters…
Courtesy : D.Gudkov
Old 30mm diam. Filters from:
AG Laser Innovation INC
https://edh.cern.ch/Document/SupplyChain/DAI/2830744
Courtesy : J.Emery
New Absorptive Neutral Density Filters required:
• T  0.25/ 0.05 / 0.025/0.005 /0.0025
• OD  0.6 / 1.3 / 1.6 / 2.3 / 2.6
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
3
2. Filter wheel status:
2.1 ND Filters…
Proposed to process order with Thorlabs:
•
•
•
•
Fast delivery and easier ordering process
Filter holder & Single filters separately
3 Filter Sets: 2 PSB Tunnel + 1 Lab
Combine filters to reach Transitivity required
Compatible Filter Wheel to consider?
•
•
•
FW1AB
6 Positions (do we require 7?)
SM1 Threaded
Component
Description
Price Unit
Units
SM1L03-P5
SM1 Lens Tube 0.3’’ Thread Depth, SM1RR included, Pack 5
51.98 e
3
155.9e
NE03B
Unmounted Ø25 mm Absorptive ND Filter, Optical Density: 0.3
28.8 e
6
172.8 e
NE06B
Unmounted Ø25 mm Absorptive ND Filter, Optical Density: 0.6
28.8 e
6
172.8 e
NE13B
Unmounted Ø25 mm Absorptive ND Filter, Optical Density: 1.3
28.8 e
6
172.8 e
NE20B
Unmounted Ø25 mm Absorptive ND Filter, Optical Density: 2.0
28.8 e
6
172.8 e
Total order
Price total
847 e
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
Proceed?
4
3. Actions check List: To-do
•
Requirements on surface (Space reservation): as in SPS
•
•
•
•
•
•
1 PC + 2 Pico-Scopes
1 VME HV Power supply with remote control
2 x Filter Wheel controllers
3 Units Europa Crate reserved
Access to Turn Clock
Laboratory PMT’s Test campaign preparation:
•
•
•
Aim: Strategies for High dynamic range coverage (MaPMT, HPD, Several PMTs …)
Tests: Linearity, Saturation levels, Resolution, Noise…
Equipment is ready, required some optical components (Diffusers, filters…)
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
5
4. Some news:
4.1 Data from last SPS tests
Cable coupling noise
synchronous with SPS
turn clock.
Specially on PMT cable
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
6
4. Some news:
4.2 Observations with all systems disconnected (only cable)
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
7
4. Some news:
4.3 Intervention to check cabling and remove amplifier
1.
PMT and Diamonds are now closer
2. No Amplififer anymore
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
8
4. Some news:
4.4 Nicer Expert application for Acquisition system prototype
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
9
BE-BI-BL Jose Luis Sirvent Blasco
10
([email protected])
2. Installation Proposal Schema: Setup-V2
PSB BWS Secondary Acquisition System
Test Installation Proposal V2 (Base + Digital)
2016-2017
LED
Filter Box
Fixed filters
Digital
4 x MMF (Spares)
100% 25%
5%
1%
MaPMT
100%
GEFE &
ICECAL_V3
Mezzanine
Spare x 2
Relay Ctrl_1
Relay Ctrl_2
FE. Power +12V
Amp. Power +12V
Amp. Power -12V
Relay Ctrl_3
Relay Ctrl_4
25%
5%
Relay
Bank
1%
FE-Prototype
100 - 25 %
2 x MaPMT Signal
1 - 5%
1 x PMT Amp. Signal
2 x CEH54 (High Voltage)
HPD HV (15-20kV)
PMT HV (1-2kV)
2 x NE18 (FilterBox)
FilterBox PMT
FilterBox HPD
3 x CB50 (Diagnostics LED)
HPD PD Bias 25-100V
PMT LED Signal
HPD LED Signal
Filter Box
PMT
R7400U
(Obsolete)
1 x NG18
(Relay Control + Power)
3 x CK50 (Analog Signal)
Analog
Waveguide
2 x SMF (GBT Link)
Waveguide
Scint
Modif PSB_TYPE
Cylindrical
H 30mm
D 30mm
GBT_TX
GBT_RX
L
E
D
Scint
Signal PMT
PSB_TYPE
Cylindrical
H 30mm
D 30mm
R9880U Series (Standard PSB PMT)
Effective Detector Area : 50 mm2
Whole PMT assembly volume:
• Cylindrical d=16mm x h = 36.4mm
R7600U-M4 Series (MaPMT for Test System)
Effective Detector Area : 4 x 63.6 mm2
Whole PMT assembly volume:
• Cubic= 30 x 30 x 37 mm
BE-BI-BL Jose Luis Sirvent Blasco
([email protected])
12