Systems Product Information [ MultiSpec® Raman ] MultiSpec® Raman: Raman Spectrometer for Laboratory and Process The Raman effect is caused by inelastic scattering when from the excitation light. Energy transfers from the pho- light interacts with molecules. Most of the incident light ton to the molecule cause rotational or vibrational tran- scatters elastically making a broadband source impracti- sitions [Stokes] or transfer energy from the molecule to cal. Thus for most common Raman techniques, a mono- the photon [anti-Stokes]. Since the energy gained/re- chromatic light source is used. The incident photon’s leased corresponds to a molecule’s energy levels, this energy changes in accordance to quantum mechanical leads to characteristic fingerprints by which molecules rules and can be detected as a shift in the wavelength can be identified and quantified. [ Raman has been proved to be useful analytic technique in a number of industries ] ❚ Chemical ❚ Forensics ❚ Pharmaceutical ❚ Biological ❚ Geological ❚ Nanomaterials ❚ Semiconductors ❚ Polymers While in Laboratory applications a wide variety of systems are available, the number of analyzers for use in process environments was limited to a few. Serving the market for 20+ years with spectrometer systems for the UV-VIS and NIR wavelength region, including the [ MultiSpec® Raman with Probe ] modular software package MultiSpec Pro II, tec5 delivered process proven spectrometer systems. Based on this experience, tec5 chose to close the gap to Raman spectrometer systems with process capabilities. © tec5 AG [ Raman Spectrum ] [ Features ] ❚Raman analyzer for process applications ❚ Short measurement time [depends on application] ❚Installation according to Laser class 1 ❚ MultiSpec Pro II Raman process software ❚ 785 nm excitation wavelength ❚ Optional software process interfaces [OPC, Profibus, etc.] ❚ Temperature-stabilized laser source ❚ Optional software modules for chemometrics and data analysis ❚ Optical probes for different measurement setups ❚ Software development kits [SDKs] available [liquids, solids, measurements through glass] ❚ Monitoring of Laser operating hours ❚ High-sensitive stabilized CCD detector ❚ 19” rack-mount standard Systems Product Information [ MultiSpec® Raman ] [ System Design ] MultiSpec® Raman Process Spectrometer System As the spectral sensitivity of the measurement system is crucial for the applicability of this technique since only a small portion of the incident photons are Raman shifted. Matching the single components used of the instruments is essential. Amongst them are the spectral efficiency of the polychromatic setup, the quantum efficiency of the detector, the Laser Source A temperature-stabilized semiconductor laser provides 50 – 500 mW of 785 nm excitation light. It is housed in a plug-in cassette with a FC/APC fiber-optic output connector at the front panel of the laser cassette which allows an easy connection to a fiber-coupled Raman probe. Spectrometer Module The Raman system uses a high throughput, high-resolution spectrometer with a sensitive TE-cooled scientific CCD array for detection. In conjunction with state-of-the-art electronics developed by tec5, it allows accurate measurements Fiber-Optic Raman Probe Being the forefront of the spectrometer system, the probe accumulates the spectral information and confine it through a set of lenses and filters and prepare it to be relayed in optical fibers to the measurement system. Aside from the optical properties, which have been matched to optimize the power budget of the spectrometer system. In contact with the sample is a Titanium/Saphire process tube, which features high thermal, chemical and pressure resistance. Providing information on the Laser state with a yellow LED and serving as a bridge to the interlock loop, the probe can be adapted to a number of measuring points. fiber diameters used of the setup and finally the light source, which is determining the accuracy of the Laser. Taken all this factors into account, the spectrometer line MultiSpecwas expanded by a new instrument which is readily available for your application. Four serial interlocks prevent the accidental activation of the laser. A special circuitry supervises interlock status and monitors life time of cassette and laser. Two external interlocks can be adapted by the customer to ensure safe operation of the system. with unsurpassed dynamic range. The spectrometer input is a standard SMA fiber-optic connector located on the front panel of the MultiSpec Raman spectrometer cassette. For different samples and measurement scenarios different probes have been designed: To measure through an optical process window, a probe with a focal length of 7.5 mm is available. The immersion probe with 1.5 mm focus features a smaller penetration depth of the focal beam so it may be used in translucent or opaque liquids. We supply also a probe with parallel beam to measure solids. The 3 mm beam diameter is perfectly used to measure a specific area of the sample with only one shot. With this probe the need for multiple measurement points is no longer necessary and reduces the analysis time extremely. [ Raman Probe – LED + Interlock Connector ] Systems Product Information [ MultiSpec® Raman ] Laser Installation according to Class 1 High output power of the laser diode, which are required for an efficient data acquisition process in Raman spectroscopy limit the applicability of most systems. With the holistic approach of tec5, an installation according to laser class 1 is at Laser your fingertips. The Laser interlock is monitoring every connection point from the laser source via optical fiber cables, the probe and the measurement volume. Laser Status LED Spectrometer Optical fibers Interlock signal Laser Status LED Probe Interlock signal Process [ Class 1 Laser Installation ] [ Software and PC Interfaces ] MultiSpec® Pro II Raman Process Package tec5’s spectroscopy software MultiSpec Pro II is available in a Raman version that features wavenumber scaling and other specific tools to adapt the software to the requirements of Raman measurements. The tools include intensity correction, optional background spectrum subtraction and allows the use of the peak detection and data export functionality of the MultiSpec Pro II software. Thus, automated process control by Raman spectroscopy is immediately available and easily configurable for standard applications. [ MultiSpec® Pro II Result View ] The MultiSpec Raman is equipped with an Ethernet interface for use in Ethernet or Gigabit Ethernet networks. The unit is also available with a HiSpeed USB interface. Process Communication The MultiSpec systems can be equipped with an OPC interface or various add-on I/O-boards [4 – 20 mA, digital I/Os, Profibus] for process communication to transfer results and status information [e.g. system error, system warning, out-of-range signal] to a process control system. Additionally, a remote control from an SPS or DCS is available to trigger maintenance measurement cycles or to stop continuous data aquisition. [ MultiSpec® Pro II Raman Package ] Systems Product Information [ MultiSpec® Raman ] [ Technical Data ] Laser Excitation Source Laser Type Fiber coupled, stabilized multimode diode laser Wavelength 785 nm Output Power 50 - 500 mW, adjustable Output Connector Laser Class FC-APC with 105 µm core diameter 3B [Class 1 Installation possible] Interlocks 4 [Key Switch, Probe Connected, and 2 external] Spectrometer Section Spectral Sensor Diode array simultaneous spectrometer [no moving parts] Detector Type High dynamic range, scientific TE-cooled CCD detector Spectral Range 300 – 3100 cm Resolution 5 cm-1 typ. Integration Time 3 ms – 10 min [typ.] Fiber Probe Probe Material [in contact with sample] Focal Plane Titanium / Sapphire [brazed] 1.5, 7.5 and none [parallel beam] from front window Length of Fibers 5 m [standard], other lengths available on request Temperature Range 5-180°C Pressure Range -1 - 100 bar [without Flange] Interlock Connector on the probe body Laser Status LED, yellow Miscellaneous Power Supply 110 / 220 V; 50 / 60 Hz Weight Operating Temperature 132.55 x 448.90 x 375.5 12 – 15 kg 5 °C – 35 °C [ Alternatively, a user may take advantage of software development kits provided for the modular product range to fully program for any application. ] Headquarters tec5 AG | In der Au 27 61440 Oberursel, Germany T. +49.(0)6171.97 58-0 [email protected] | www.tec5.com MultiSpec® is a registered trademark of the tec5 AG. www.tec5uk.com | www.tec5usa.com tec5_PI_Systems_MultiSpec Raman_e_2014|09 Dimensions [mm ] 3
© Copyright 2026 Paperzz