Rechargeable and Primary Cell DBS Systems St. Jude Medical is focused on reducing risk by continuously finding ways to put more control into the hands of those who save and enhance lives. Constant Current for Constant Symptom Control. The St. Jude Medical Neuromodulation Division is constantly working to find ways to put more control into the hands of those who treat and manage neurological disorders. Our innovative portfolio of deep brain stimulation (DBS) systems features both primary cell and rechargeable implantable pulse generators (IPGs) that use constant current pulse delivery to maintain consistent therapy. Our comprehensive offering allows you to tailor therapy to meet each patient’s specific needs. 1. 2. 3. 4. Medtronic. Activa RC Rechargeable Neurostimulator Implant Manual. Minneapolis, Minn.; 2009. Advanced Neuromodulation Systems. Brio™ Neurostimulation System Clinician’s Manual. Plano, Tex.; 2009. Data on file. Merrill DR, Bikson M, Jefferys JGR. Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods. 2005;141(2):171-198. ATRIAL FIBRILLATION Global Headquarters One St. Jude Medical Drive St. Paul, Minnesota 55117 USA +1 651 756 2000 +1 651 756 3310 Fax CARDIAC RHYTHM MANAGEMENT Neuromodulation Division 6901 Preston Road Plano, Texas 75024 USA +1 972 309 8000 +1 972 309 8150 Fax CARDIOVASCULAR St. Jude Medical Europe, Inc. The Corporate Village Figueras Building Avenue Da vinci Iaan, 11 Box F1 B-1935 Zaventem Belgium +32 2 774 68 11 +32 2 772 83 84 Fax NEUROMODULATION St. Jude Medical Australia Pty. Ltd. 17 Orion Road, Lane Cove NSW Australia 2066 +61 2 8912 6300 +61 2 8912 6320 Fax St. Jude Medical Brasil Ltda. Rua Frei Caneca, 1380 7º ao 9º andares 01307-002 - São Paulo (SP) Brasil +55 11 5080 5400 +55 11 5080 5423 Fax sjmneuro.com Indications: St. Jude Medical Deep Brain Stimulation (DBS) Systems are indicated for use in unilateral or bilateral stimulation of the thalamus, internal globus pallidus (GPi), or subthalamic nucleus (STN) in patients with levodopa-responsive Parkinson’s disease. ActiveTip, Brio, Guardian, Libra, and LibraXP are trademarks of Advanced Neuromodulation Systems, Inc. doing business as St. Jude Medical Neuromodulation Division. ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are trademarks and service marks of St. Jude Medical, Inc. and its related companies. ©2009 St. Jude Medical. All rights reserved. Item No. 4101-02 Innovative Technology for Consistent Therapy Brio™ Rechargeable IPG Increased Surgical Efficiencies The smallest, longest-lasting DBS IPG for enhanced patient satisfaction. 1, 2 The Brio IPG offers numerous configuration options and an easy-to-use charging system to maximize success in therapy management. With its small size and 2.5-cm allowable implant depth, it provides flexibility in pocket placement, reduces palpability and improves cosmesis. It also features an easy-to-use wireless charging system. Approved for at least 10 years of use with no manufacturer-imposed shut-off date, the Brio IPG is intended to reduce replacement procedures and is ideal for patients with low to high power requirements who will benefit from an extended battery life and are willing to follow a recharge protocol. St. Jude Medical DBS systems are designed to maximize procedural efficiency. All St. Jude Medical DBS IPGs feature constant current pulse delivery, which automatically compensates for changes in impedance to maintain a consistent stimulation field. They are also capable of using electrode arrays with more than one active cathode (a multipolar array), providing more options to match the stimulation field to the needs of the patient than systems that support only single cathode arrays. The Constant Current Difference LibraXP ™ IPG The LibraXP IPG offers exceptional flexibility. It features the highest battery capacity in a DBS IPG by at least 40%, which may result in fewer replacement surgeries and thus fewer interruptions in therapy. The LibraXP IPG is also the thinnest dual-channel primary cell DBS IPG on the market. With an implant depth of up to 4.0 cm and the ability to support unilateral or bilateral stimulation, it offers a broad range of implant and programming options. The LibraXP IPG is the ideal choice for those who require bilateral stimulation with the benefits of a primary cell IPG. Collapse-resistant Tunneling Tool Fast, easy connections require the tightening of only one setscrew, improving the efficiency of the procedure. As stimulation is delivered to the tissue, electrochemical reactions occur at the electrodes, causing the tissue impedance to increase as the pulse is delivered. onstant current devices automatically compensate for rising impedance by C increasing the voltage within each pulse, thereby maintaining a consistent stimulation field for the full duration of the pulse. onstant voltage devices do not compensate for this increasing impedance; C therefore, the stimulation field gets smaller as the pulse is delivered. Solid yet shapeable, the tunneler is designed to enhance pushability and maneuverability. Bootless Extensions Built-in Strain Relief Highest-capacity DBS IPG for maximum flexibility.3 Single Setscrew Connections An integrated strain relief system is designed to reduce steps during surgery by eliminating the need for suturing. Self-sealing septum and individually sealed compartments eliminate the need for an outer boot, saving procedure time and minimizing device profile. Broad Programming Options St. Jude Medical DBS systems are designed to provide more control to both the physician and the patient. Versatile Clinician Programmers Constant Current Delivers a Constant Stimulation Field.4 Featuring multiple programming options, the clinician programmers are designed to enable a closer match between patients’ needs and the stimulation settings for better symptom management and more efficient use of battery power. A broad frequency range with a 2-Hz step size provides options to fine-tune treatment. A wide amplitude range, featuring 256 settings, is designed to optimize therapy and maximize battery longevity. Constant Voltage Easy-to-use Patient Controllers The patient controllers empower patients to adjust stimulation within clinician-prescribed limits. With the ability to self-manage stimulation settings, patients have more control over their therapy, which may reduce the number of reprogramming visits. Complementary Leads and Accessories St. Jude Medical DBS IPGs are compatible with a full complement of leads and accessories for enhanced precision, efficiency and patient comfort. Libra™ IPG Highest battery capacity in its class for extended therapy delivery.3 Low-profile Extensions ActiveTip ™ Lead Technology The Libra IPG is designed to be long-lasting, easy to implant and simple to manage. It features the highest battery capacity in its class (by 40%), which may result in fewer replacement procedures. With an allowable implant depth of 4.0 cm, the Libra IPG offers broad flexibility during the implant procedure and may improve patient cosmesis. It is an excellent choice for smaller patients, patients receiving a unilateral implant, or patients receiving a bilateral implant who would benefit from the programming flexibility and confidence that two independent IPGs provide. Constant Current Electrically active tips provide more options for placement of the stimulation field. Lower-profile extensions are designed to improve patient comfort, cosmesis and satisfaction. The low-profile design may reduce risk of erosion, thereby decreasing the risk of having to reoperate. Highly Efficient Leads and Extensions Intrapulse Time (µs) Neural Target Constant Voltage Stimulation Constant Current Stimulation Leads feature stranded wiring for minimal impedance. With low-impedance leads and extensions, the DBS systems are designed for efficiency, which may prolong battery life and extend the time between battery replacements or recharging. Auto-capture Lead Fixation System The Guardian™ burr hole cover system features a self-locking clip and flexible base to reduce complexity and enhance control in DBS lead fixation. St. Jude Medical’s exceptional portfolio of DBS products provides more choice in therapy optimization to help you better meet your patients’ unique needs
© Copyright 2026 Paperzz