12 Madrid Road - 003 Rev P - Electrical

N
0
1
2
3
Please note: drawings are only indicative / preliminary.
Exact layouts to be determined.
Height of plug sockets TBC.
Contractor to liaise with Saunders Interiors prior to First fix
plumbing/electrics or determination of any walls.
4
Metres
WiFi extender
positioned here
Free
standing
Dryer
Free
standing
W/M
Wire for
Extractor Fan
Wire for
Fridge Freezer
1
SAT
TV/FM
3
2
3
Wire for
Door bell
Cloak
Storage for plates & glasses
900
900
900
900
1
50
1
1
S3
1100
1000
Wine
Fridge
D/W
Sink
H
Island Unit
2200
Wet underfloor
heating in whole of
kitchen extension
Heated
Towel Rail
with summer
element
up
Reinstate
original
porch
pendant
50
Playroom
1
1
Move Electrical
fuseboard to
left as much as
possible.
Fridge Freezer
1200
New alarm control
panel location
Extractor
Fan
Storage
900
50
Floor to ceiling storage cupboards
Cupboard
housing
Mega Flow
BT
C6
C
music wiring
C6 All
located here.
5
600
S
SAT
TV/FM
Utility Room
TV - 700mm
Bicycle to lean against this wall
Living Room
Electrical underfloor
heating in Utility
Wire for Dishwasher
Gas Hob
1250
Switch for outside lights.
1 x double USB
socket
Wire for Quooker hot water tap
Wire for Fridge
Wire for 2 x Ovens
& Warming drawer
Sink
LED strip below and
above wall units
1000
Cupboard
housing
Boiler
SAT C6
TV/FM
Security Light
position TBC
Wire for
W/M & Dryer
LED Strip lighting
for shelves
1 x outside plug
socket reinstated
LED strip below and
above wall units
5
2698
Dining Table
2200 L
x 1200 W
Electrical underfloor
heating in hallway
1000
Wire for
Boiler
already existing plug sockets
2 x double sockets to be reinstated
2 x existing
security
lights to be
checked and
working
Cupboard
housing
underfloor
heating
manifold
TBC
SAT
TV/FMC6
TV - 1000mm
Radiator
W600 x H600mm
3 x low level stair lights
above skirting - to first floor
landing - position TBC
2 x outside garden speakers
to be located on the party wall
1 x unswitched fuse spur required next to alarm control panel
&
1 x tel extension cable located adjacent to alarm control panel
Client wants this moved
to storage side if possible
Electrical Installation Key:
LUMINAIRES
COMMUNICATIONS SOCKETS
Pendant
Wall Light
Recessed Downlighter
Sensor light
Directional Spot Light
Low level Light
LED Strip Lighting
Waterproof Light
Reading Light
Flush Floor Light
SAT
TV/FM
BT
C5 C6
Do not scale from this drawing.
Rev
Issue Status/Notes
Date
1
Television
Master BT Socket
Cat 5 or Cat 6 Outlet
POWER
SWITCHES
1
Music Speaker - wall
or ceiling mounted
Key
2
2
3
Double Socket
1, 2, 3 or 5 gang
5 dimmer switch
3
FIRE DETECTION
Single 5-amp Socket
1, 2 or 3 gang
single switch
H
S
Heat Detector
C
Carbon Monoxide
Detector
Smoke Detector
Wiring for Doorbell
All dimensions must be checked on site
by the contractors with Saunders Interiors.
Change of Ceiling Height
Saunders Interiors Ltd
Party Wall
[email protected]
All dimensions in millimetres unless
otherwise stated.
New Wall Fabric
07717 841 640
Project Title:
Drawing Title:
Issue Date:
12 Madrid Road, London SW13 9PD
12 Madrid Road - 003
18.08.2015
Client Name:
Scale:
Drawing Name:
Rev:
Trish & Ian Barrigan
1:50 at A3
Ground Floor Electrical Plan Proposed
P
LED strip below and
above wall units
Wire for
Extractor Fan
900
552
1100
595
1000
327
1000
2125
1000
1168
SAT
TV/FMC6
623
649
1500
1000
Dining Table
2200 L
x 1200 W
963
969
1000
613
2698
613
2125
752
1377
1500
1098
752
1000
486
1000
1000
Wet underfloor
heating in whole of
kitchen extension
550
5
752
2000
2000
1
752
1000
500
Island Unit
2200
595
450
500
1300
H
1000
Sink
500
500
D/W
450
1000
Fridge Freezer
1200
50
888
1
Wine
Fridge
888
Playroom
1000
1
1000
900
500
600
900
500
50
900
552
50
SAT
TV/FM
Storage for plates & glasses
687
C6
1374
313
1100
900
2000
5
Gas Hob
1250
TV - 700mm
437
327
SAT
TV/FM
687
Wire for Dishwasher
5700
Switch for outside lights.
327
Wire for Fridge
Wire for 2 x Ovens
& Warming drawer
1 x double USB
socket
Wire for Quooker hot water tap
327
Wire for
Fridge Freezer
281
WiFi extender
positioned here
LED strip below and
above wall units
TV - 1000mm
2125
8498
250
1 x unswitched fuse spur required next to alarm control panel
&
1 x tel extension cable located adjacent to alarm control panel
2700
2 x outside garden speakers
to be located on the party wall
already existing plug sockets
2 x double sockets to be reinstated
Wire for
W/M & Dryer
Living Room
1937
2044
820
C997
997
S
997
Floor to ceiling storage cupboards
music wiring
C6 All
located here.
New alarm control
panel location
Extractor
Fan
Cupboard
housing
Mega Flow
446
892
446
563
BT
Storage
Cloak
up
613
487
1200
1200
475
475
1200
613
746
Electrical underfloor
heating in hallway
1414
475
S3
746
487
1414
475
Heated
Towel Rail
with summer
element
Move Electrical
fuseboard to
left as much as
possible.
2
3
Reinstate
original
porch
pendant
3
1
1
535
563
541
Utility Room
475
820
1710
Bicycle to lean against this wall
926
Electrical underfloor
heating in Utility
410
Wire for
Door bell
997
475
TV - 700mm
997
367
997
926
535
710
535
1
Sink
475
541
Free
standing
W/M
Free
standing
Dryer
928
Cupboard
housing
Boiler
475
541
563
563
LED Strip lighting
for shelves
SAT C6
TV/FM
Security Light
position TBC
463
2 x existing
security
lights to be
checked and
working
Cupboard
housing
underfloor
heating
manifold
TBC
Wire for
Boiler
1414
1414
1414
Radiator
W600 x H600mm
3 x low level stair lights
above skirting - to first floor
landing - position TBC
Client wants this moved
to storage side if possible
N
0
1
2
3
Please note: drawings are only indicative / preliminary.
Exact layouts to be determined.
Contractor to liaise with Saunders Interiors prior to First fix
plumbing/electrics or determination of any walls.
4
Metres
Exact position of
reading lights TBC
Wire for
illuminated
mirror
C5
3
3
Extractor Fan
Shaver socket
inside bathroom
cabinet
C5
Existing lighting remains.
All needs to be checked as
the current spots flicker and
central pendant is not working.
Super King Bed
1800W x 2000L
Walk-in
Wardrobe
950
Electric under
floor heating
Master Bedroom
Heated
Towel Rail
with summer
element
Heated
Towel Rail
with summer
element
3
Ensuite
3
2
up
3
Electric under
floor heating
2
Bedroom 3
800
C5
1
Shower
S
1
C5
2
Bedroom 2
Bathroom
Existing
switch for
upstairs
lighting
341
3
274
Extractor Fan
1400
Shaver
socket
position
Wire for
illuminated
mirror
Alcove lighting
Patch panel to be located in
eaves of office 2nd floor
- router to remain in office.
BT master telephone socket
fitted in eaves of office.
Existing Cat 5 cables to
remain on 1st floor.
Points positioned as
per drawing.
Alcove lights
Electrical Installation Key:
LUMINAIRES
COMMUNICATIONS SOCKETS
Pendant
Wall Light
Recessed Downlighter
Sensor light
Directional Spot Light
Low level Light
LED Strip Lighting
Waterproof Light
Reading Light
Flush Floor Light
SAT
TV/FM
BT
C5 C6
Do not scale from this drawing.
All dimensions must be checked on site
by the contractors with Saunders Interiors.
Rev
Issue Status/Notes
Date
All dimensions in millimetres unless
otherwise stated.
SWITCHES
1
Television
Master BT Socket
2
1
Cat 5 or Cat 6 Outlet
Music Speaker - wall
or ceiling mounted
2
3
POWER
Double Socket
1, 2, 3 or 5 gang
5 dimmer switch
3
FIRE DETECTION
Single 5-amp Socket
1, 2 or 3 gang
single switch
H
S
Heat Detector
C
Carbon Monoxide
Detector
Smoke Detector
Wiring for Doorbell
Key
Change of Ceiling Height
Saunders Interiors Ltd
Party Wall
[email protected]
New Wall Fabric
07717 841 640
Project Title:
Drawing Title:
Issue Date:
12 Madrid Road, London SW13 9PD
12 Madrid Road - 003
18.08.2015
Client Name:
Scale:
Drawing Name:
Rev:
Trish & Ian Barrigan
1:50 at A3
First Floor Electrical Plan Proposed
P
1106
C5
1715
W
illum
1094
3
3
C5
Existing lighting remains.
All needs to be checked as
the current spots flicker and
central pendant is not working.
1724
Super King Bed
1800W x 2000L
Walk-in
Wardrobe
900
900
Electric under
floor heating
Master Bedroom
Heated
Towel Rail
with summer
element
Heated
Towel Rail
with summer
element
3
Ensuite
628
Electric under
floor heating
3
Shower
3033
S
1802
274
Extractor Fan
1166
1166
717
341
800
375
858
912
2
up
858
912
329
2
483
Existing
switch for
upstairs
lighting
1400
Shaver
socket
position
Wire for
illuminated
mirror
Alcove lighting
Existing Cat 5 cables to
remain on 1st floor.
Points positioned as
per drawing.
Patch panel to be located in
eaves of office 2nd floor
- router to remain in office.
BT master telephone socket
fitted in eaves of office.
3
Wire for
illuminated
mirror
Extractor Fan
Shaver socket
inside bathroom
cabinet
500
1534
Bedroom 2
500
Bathroom
1597
1597
Bedroom 3
2
1722
1376
1722
1105
3
Alcove lights
1921
1105
C5
1802
482
1
482
1802
C5
482
1
482
3
1921
772
1376
439
950
1000
150
Switch for outside lights.
Outside plug
socket
1
wall light to be centered on wall
and height of 1800mm
4000
150
Flush
floor
lights
Outside plug
socket
wall light to be centered on wall
and height of 1800mm
150
400
400
2 x garden speakers
positioned on party wall
Garden Electrical Plan
Do not scale from this drawing.
Rev
Issue Status/Notes
Date
Key
All dimensions must be checked on site
by the contractors with Saunders Interiors.
Change of Ceiling Height
Saunders Interiors Ltd
Party Wall
[email protected]
All dimensions in millimetres unless
otherwise stated.
New Wall Fabric
07717 841 640
Project Title:
Drawing Title:
Issue Date:
12 Madrid Road, London SW13 9PD
12 Madrid Road -
18.08.2015
Client Name:
Scale:
Drawing Name:
Rev:
Trish & Ian Barrigan
1:50 at A3
Garden Electrical Plan
P