6000-50 / 6000-51 The New Norgren Automatic drain • New and improved autodrain, which will fit all previous models • Higher operating pressure than previous units • Can be used on all mediums • 6mm / ¼ “ Push In Fitting to allow easy drain away of the condensate • Lever actuated design provides improved performance and durability* • Accessible Manual Override to comply with UK Water Board Condensate regulations Technical Data Fluid: Compressed air: Lubricated or non Lubricated Maximum Pressure:20 bar (300psig) Recommended Operating Pressure: 0.7 bar (10.5psig) to 17 bar (255psig) o o Operating Temperature: 1.5 C to 80 C Automatic Drain Connection: 6mm / ¼” PIF Drain Operation Pressure to close drain: Greater than 0.3bar Pressure to open drain: Less than 0.2bar 3 Minimum air flow to close drain: 0.6dm /s Twist from 0 to I to actuate manual override *Note : Drains should be used in the upright condition. Norgren recommend using Norgren specified tube tolerances and minimum bend radius where the condensate is piped away. This helps avoid blockage of the downstream system. Also the sealing gasket must be correctly assembled onto the autodrain unit before attaching to the bowl. Materials Manual Override, Bonnet, Main Body and Piston: acetal Lever: glass filled acetal Float: Engineering Polyamide Gaskets: silicon free nitrile rubber Valve body: polycarbonate and geolast Valve Seat: brass Spring: stainless steel PIF collet: nickel plated brass O ring: silicon free nitrile rubber Body: brass Part Number 6000-50 6000-51 PIF 6mm ¼” OD 16mm Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in event of such failure. System designers must provide a warning to ends users in the system instruction manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Water vapour will pass through these units and will condense into liquid if air temperature drops in the downstream system. Install an air dryer if water condensation could have a detrimental effect on the application 02/03 Our policy is one of continuous research and development. We th erefore reserve the right to amend, without notice, the specifications given in this document. For your local Norgren Technical Sales Centre phone 0345 662266. For your local Norgren Distributor phone 0345 227777. N/AL.X.ADT.100.01
© Copyright 2026 Paperzz