Version: 1 Revision Date: 11/30/2012 PE anti-human CD55 Antibody Catalog# / Size 311308 / 100 tests Clone JS11 (See other available formats) Other Names DAF (Decay Accelerating Factor) Isotype Mouse IgG1, κ Ave. Rating ★★★★★ 0 reviews Description CD55 is a 60-70 kD glycosylphosphatidylinositol (GPI)-anchored single chain glycoprotein also known as decay-accelerating factor (DAF). It is expressed on hematopoietic cells including erythrocytes and many non-hematopoietic cells. CD55 accelerates the dissociation of the components of the C3convertases (namely C2a from C4b in the C4bC2a complex, a C3-convertase of the classical pathway, and factor Bb from the C3bBb complex, a C3convertase of the alternative pathway) to protect cells from inappropriate damage caused by autologous complement. CD55 has been reported to reduce the efficiency of NK cell lysis and induce signal transduction in T cells. CD55 has also been shown to interact with CD97 and bind to Coxsackie and Echovirus. Reactivity Human Human peripheral blood lymphocytes stained with JS11 PE, then detected with anti-mouse IgG FITC See PE spectral data View Moxi Flow Data Formulation Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and 0.2% (w/v) BSA (origin USA). Preparation The antibody was purified by affinity chromatography, and conjugated with PE under optimal conditions. The solution is free of unconjugated PE and unconjugated antibody. Concentration Lot-specific (please contact technical support for concentration and total µg amount, or use our Lookup tool if you have a lot number.) Storage & Handling The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze. Application FC - Quality tested Recommended Usage Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. Test size products are transitioning from 20 µl to 5 µl per test. Please check your vial or your CoA to find the suggested use of this reagent per million cells in 100 µl staining volume or per 100 µl of whole blood. It is recommended that the reagent be titrated for optimal performance for each application. Read more at www.biolegend.com/testsize regarding the test size change. Excitation Laser Blue Laser (488 nm) Green Laser (532 nm)/Yellow-Green Laser (561 nm) Application References 1. Kishimoto T, et al. Eds. 1997. Leucocyte Typing VI. Garland Publishing Inc. London. 2. Peyron P, et al. 2000. J. Immunol. 165:5186 3. DeZern AE, et al. 2014. Exp Hematol. 42:857. PubMed (PubMed link indicates BioLegend citation) Publication Library RRID AB_314865 (BioLegend Cat. No. 311308) Antigen Details Structure GPI-achored regulator of complement activation (RCA), type I membrane glycoprotein, 60-70 kD Distribution Hematopoietic cells including erythrocytes and many non-hematopoietic cells Function Protects against inappropriate complement activation and cell damage, induces signal transduction, reduces the efficiency of NK cell lysis Ligand Receptor C3b, C4b, CD97, Coxsackie viruses Antigen References 1. Schlossman S, et al. Eds. 1995. Leucocyte Typing V. Oxford University Press. New York. 2. Hamann J, et al. 1996. J. Exp. Med. 184:1185. 3. Fujita T, et al. 1987. J. Exp. Med. 166:1221 Workshop VI N-L060 Gene ID 1604 UniProt View information about CD55 on UniProt.org Documentation Technical data sheet Certificate of Analysis Safety Data Sheet Related Protocols Cell Surface Immunofluorescence Staining Protocol Related FAQs There are no FAQs for this product. Related Categories NeuroscienceProducts > Neuroinflammation > Neuroinflammation Antibodies > Immunology > Human Immunology > Stem Cells > CD55 (DAF) > Immunology > Human Immunology > CD and Related Molecules > CD55 (Decay Accelerating Factor) > JS-11 > Other Formats Description Clone Applications APC anti-human CD55 JS11 FC Biotin anti-human CD55 JS11 FC FITC anti-human CD55 JS11 FC Purified anti-human CD55 JS11 FC PE/Cy7 anti-human CD55 JS11 FC PerCP/Cy5.5 anti-human CD55 JS11 FC For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products. *These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use. BioLegend Inc., 9727 Pacific Heights Blvd, San Diego, CA 92121 www.biolegend.com Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587
© Copyright 2026 Paperzz