LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience and Comfort 1.1 What is Multi V Water II? 1. Introduction LG Water Cooled system Air Cooled System Water Cooled System Cooling Tower Water pipe Refrigerant pipe Outdoor Unit Indoor unit Boiler 1.2 External Appearance 1. Introduction 3Ø, 380-415V, 50Hz & 3Ø, 380V, 60Hz ARWN100LA2 ARWN200LA2 ARWN500LA2 ARWN600LA2 ARWN300LA2 ARWN400LA2 1.3 Product Background 1. Introduction High Performance 1.3 Product Background 1. Introduction High Performance 5 5 4.5 4.5 Water cooled outside Water cooled outside 4 4 3.5 COP COP 3.5 Air cooled outdoor 3 3 Air cooled outdoor 29%↓ 2.5 2.5 49%↓ 2 1.5 2 0 10 20 Floor Indoor temperature(℃) 30 1.5 30 40 50 Outdoor temperature [oc] Outdoor temperature(℃) 60 1.3 Product Background 1. Introduction 1.4 System Layout 1. Introduction Beautiful Exterior 1.4 System Layout 1. Introduction Cooling Tower Water pipe Refrigerant pipe Refrigerant pipe Outdoor Unit Indoor unit Boiler Water pipe 1.4 System Layout 1. Introduction ■ High Rising Building Discharge air circulation expected site Efficiency down Efficiency down Efficiency down • Solve the outside air flow problems • Aesthetic external appearance • Energy Saving Water cooled system is the optimal solution 1.4 System Layout 1. Introduction ■ Office Building 100m Or more Shops • The solution of discharge air circulation and indoor unit height difference limits • Energy saving • Aesthetic Appearance • Simultaneous operation during interim season • No external installation space for ODU • Height difference is 50m or more Water cooled system is the right solution 2.1 Product Line up 2. Line up 2.1.1 Outdoor Unit Outdoor unit Power 10HP 20HP 30HP 40HP 50HP 60HP 8HP 16HP 24HP 32HP 40HP 48HP 3Ø 380~415V 50Hz 3Ø 380V 60Hz 3Ø 460V 60Hz Outdoor unit Power 3Ø 220V, 60Hz 2.1 Product Line up 2. Line up 2.1.2 Indoor Unit kW 1.6 2.2 2.8 3.6 4.2 5.6 7.1 8.2 10.6 12.3 14.1 23.9 30.2 Btu/h 5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k ART COOL Series Gallery SRAC Wall Mounted Mirror 1Way Ceiling Cassette 2Way 4Way Ceiling & Floor Ceiling Suspended Ceiling Concealed Duct High Static Low Static Built-in Floor Standing With Case Without Case Console Fresh air Intake 3.1 USP 3. USP 3.1.1 Multiple Heat Source Various heat source Cooling Tower Direct Expansion AHU Local power plant Boiler Heat Source Multi V IDU Water-cooled Multi V ODU 3.1 USP 3. USP 3.1.2 Wider Operation Range Cooling Heating 3.1 USP 3. USP 3.1.3 Installation Space / Reduced Installation Area Compact Size and excellent space efficiency 1,120mm 547mm 772mm ※ Water Source Multi V 20HP - Weight : 238 kg ※ Stacking is possible which further saves space. 3.1 USP 3. USP 3.1.5 DC Inverter Compressor Oil injection Mechanism Optimized Scroll Shape For R410A High reliability in low rpm operation High Efficiency in partial-load operation Oil Discharge Reduction LG DC Inverter Motor High reliability in high rpm operation Enhanced Oil Circulation Teflon Coated Bearing High-performance Oil Pump High Efficiency Low Noise 3.1 USP 3. USP Unit: mm 3.1.6 Plate Type Sub-cooler Plate type Heat Exchanger Double Pipe Plate HEX Remark 20.1 D42.7 169.4 H 187 47.6 200 Shape 225.4 130.6 370 521.1 W 72 H254 x W521 x D47.6 H197 x W107 x D40 Increased Sub cooling 3.1 USP 3. USP 3.1.7 Synchronized Operation Zone A Optimal solution on simultaneous operation Heating or cooling mode according to OSU. Heat exhausting Cooling Need not separate Heating/Cooling pipe. (Central A/C : 4 pipe, W/C Multi V : 2 pipe) Heat exhausting Cooling If the cooling & heating capacity are same, it operates only with the circulation of water. High efficiency system Heat Absorption Heating Linear control with inverter system Heat Absorption Heating Zone B 40% higher COP compared with Air-cooled type Max. 80% higher COP in the case of simultaneous operation 3.1 USP 3. USP 3.1.8 Better Performance 5.0 DC Inverter Compressor 4.7 4.3 DC Inverter Unit Combination Plate Type Heat Exchanger S Co. LG M Co. * Based on 10HP model 3.1 USP 3. USP 3.1.9 Long Piping Longest Piping Length 150m, Total Piping Length 300m Comparison with Competitor ▶ The longest piping length : 150m ▶ The total piping length : 300m LG A Co. Actual Piping Length 150 m 120 m Equivalent Piping Length 170 m 140 m Total Piping Length 300 m 300 m Outdoor Unit Elevation 50m Longest pipe length after 1 branch : 40m Water Pipe Refrigerant Pipe Between Indoor Units 15m Indoor unit 3.1 USP 3. USP 3.1.10 Black Box and Back-up Function Black Box - Recording operation data history before system failure (3 min.) - Precise Analysis & Decision - Fast trouble-shooting Back up function Compressor failure situation 1. Inverter Comp. failure Failure 2. CH21(Error code) is displayed Inverter Comp. Constant Comp. 3. Back-up by field setting (Dip S/W) 3.1 USP 3. USP 3.1.11 BLDC Inverter Units 38dB(A) AC Motor 28dB(A) [ BLDC motor for 4way ] [ BLDC motor for 1way ] 33dB(A) BLDC Motor 70% 90% 100% 110% [ Wide operation range ] 130% AC motor BLDC Inverter [ Weight comparison ] 3.1 USP 3. USP 3.1.12 Network Solution • User-setting Auto Changeover • Mode Override (Master / Slave) Master Slave Slave • Free Access of Group control • Indoor Control - Each IDU Lock Function - Each IDU Temp. Range Setting 3.2 USP 3. USP 3.2.1 High Energy Efficiency 5.0 [128%] 3.90 [100%] ARUN100LT2 Multi V PLUS II ARWN100LA2 Multi V Water II Better Performance and Stable than the same capacity air cooled system 3.2 USP 3. USP 3.2.2 High Efficiency High Efficiency Volume 86% down Increase Sub Cooling : 100m height Installation - Optimization for EEV flow control factor Ensure Field Reliability - Stable Flow Rate, Refrigerant Noise down Existing control Target temperature Fuzzy control 3.2 USP 3. USP 3.2.3 Self Diagnosis Function Boiler ☞ ‘Flow S/W Error’ caused by the water flow shortage [CH24] - Check the cooling tower & pump - Check the water pipe - Check the strainer Cooling tower ☞ ‘High pressure Error’ [CH43] - Water flow shortage - Raise of water temperature (Check the cooling tower) - Check the cooling cycle of product Pump Flow S/W error Strainer Flow S/W High/Low Presser error 3.3 Product Comparison 3. USP 3.3.1 System Comparison Compact Design High Efficient System Cost Comparison 1,120mm 125% 100% 81% 130% 100% 547mm 772mm Front SVC panel Weight (170kg) Pile up (60HP) W/C Multi V W/C MultiV + AHU Central A/C + AHU Central A/C Initial Cost Running Cost ※B1F~F Office Building Case in Kazakhstan 62% less footprint 3.4 Benefits 3. USP 3.4.1 Low Running Cost End-user Low Running Cost 3.4 Benefits 3. USP 3.4.2 Multiple Applications End-user Water cooled system is suitable for High rising building difficult to apply air cooled system, remodeling building installed central air conditioning system, severe cold area. etc. Economical installation, maintenance cost simultaneous Cooling heating load facility Government & public office Underground space Premium/ high rise apartments Partial / special load Places requiring Individual A/C. Existing equipment remodeling 3.4 Benefits 3. USP 3.4.3 LG Air Conditioner Technical Solutions (LATS) - Multi V Consultant • Convenient model selection • Highly user-friendly design (Autocad Version) • Automatic piping design & check Download & auto upgrade from Sales Supporting System (http://www.lgeaircon.com) <Multi V model selection> Consultant 3.4 Benefits 3. USP 3.4.4 LG Monitoring Viewer (LGMV) Installer • Easy start-up, Easy trouble shooting • Monitoring whole system such as compressor, fan, valves, etc USB - Operation State - Indoor Controller - Cycle View
© Copyright 2026 Paperzz