Product description:
The Fluorescence TrayCell is an accessory for fluorescence spectrometers.
Inserted into the spectrometer’s cell holder, it expands the capabilities of the spectrometer by
enabling fluorimetric examinations of samples at volumes of only 2 µl. Due to this, a breakdown, or reconstruction of the unit, is not required.
Advantages and benefits:
// Low sample consumption due to a minimum volume requirement of only 2 µl – samples can also be retrieved.
// High sensitivity because samples can be measured undiluted.
// Classic cell measurements as well as drop analysis can be
carried out due to high flexibility.
// Complete cost control as the system can be compiled made-to-order.
// Uncomplicated handling: pipette the sample, put the lid on,
start the measurement.
// Maintenance-free: no movable parts can wear out or be misaligned.
// The simple “plug and play” accessory upgrades and broadens
existing systems by quickly converting them to a ‘drop analysis system’.
// Broadens the spectrometers testing capabilities by opening up
new application fields and addressing new target groups.
Fields of application:
Users of molecular biological fluorescence assays and fluorescence spectrometers in the field of molecular biology required to
examine small sample volumes and valuable samples.
Specification:
2 µl sample volume
Size: cell dimensions 51.5 x 12.5 x 12.5 mm (height x width x depth)
With lid, quartz glass measuring head, anodised aluminium
holder and stainless steel lid with glued-in mirror.
“Right-turn” emission geometry (other geometries possible)
Center height 8.5 mm, adapters for 15 mm and 20 mm are
enclosed.
Scope of delivery:
Including lid, centre height adapters and screw driver packaged in a Peli Case.
Patent
Pending
High Precision in
Spectro-Optics
Sample
New
// Functional principle
The Fluorescence TrayCell can be inserted into the cuvette holder like
a standard cuvette and can be fitted to the height of the light beam
by using adapters. By way of the Fluorescence TrayCells optical elements, the excitation light is channelled directly onto the sample drop
with high efficiency. Through the mirror inside the lid, the fluorescent
light, emitted in every spatial direction, is then collected in large numbers and lead to detection. Valuable samples can easily be pipetted off
again and processed further.