Membrane two- and three- way regulation valves – line 515 line Use - in regulation circuits of heating, air-conditioning and waterworks systems for accurate flowage regulation of non-aggressive liquids, gases, and fumes up to a temperature of 200°C. The piping is clean, free of pressure impacts. Design - two-way or three-way – two-way a) direct function – D the higher the entry signal is, the lower the flowage via the valve is b) restoring function – R the higher the entry signal is, the higher the flowage via the valve is – three-way a) mixing function – Y the higher the entry signal is, the flowage either decreases or increases at the same time TECHNICAL DATA – Valve regulation Nominal diameter and connection threads in body DN15 1/2", DN25 1" Nominal pressure PN 16 0.16 až 6 m3/h Nominal flowage KV Regulation lift DN15 10 mm DN25 16 mm Function direct D restoring R mixturing Y Flowage characteristics linear L app. linear ≈ L (Y) equal-percentage E Temperature of reg. media max. 200°C Max. pressure gradient p=0.6 MPa Cone untightness into the seat max 0.2% at KV Type Material body brass casting cone and seat stainless steel Group DN Function sealings PTFE Membrane power unit H10 and H16 Entry signal Regulation lift H10 DN15 H16 DN25 Climatic resistance 20 – 100 kPa 10 mm 16 mm T23 signal entry Flowage flowage characteristics K (m3/h) V 515 Membrane regulation valve PN16 DN15 Regul. lift 2 DN25 4 1 D direct 3 Table 1: Combination survey of DN and KV Nominal diameter 0.16 0.25 DN 0.6 1.0 1.6 2.5 4.0 6.0 15 Function Table 2: Combination of flowage characteristics, function and KV D R Y D App. R linear ≈L Y D Equalpercentage R E Y Linear L 5 Y mixing T23 20 – 100 kPa 6 individual linear L approx. linear ≈L equal-percentage E 9 25 Flowage characteristics R restore Nominal flowage KV (m3/h) 0.4 Nominal flowage KV (m3/h) 0.16 0.25 0.4 0.6 1.0 1.6 2.5 4.0 6.0 H=10 DN combination and nominal H=16 flowage KV acc. to tab. 1 1 2 3 01 02 03 04 05 06 07 08 09 0.16 0.25 0.4 0.6 1.0 1.6 2.5 4.0 6.0 Combination of nominal flowage KV, flowage characteristics and function according to table 2 405 Meaning of individual numbers JKPOV Middle Nomin. LARM a.s., Triumf 413, 384 11 Netolice, ČR Tel.:+420 388 386 211, Fax:+420 388 386 212, e-mail: [email protected] Connector 6/ M 14x1,5 PAN 13 0120,30 D Data required for an order In your order, it is necessary to indicate number of pieces, name of the device, nominal diameter, function, flowage characteristics, nominal flowage, JKPOV number if available, and time of delivery. Sample order H1 All technical parameters subjects to change without notice d d H2 H We are ordering 10 pieces of MRV515, nominal diameter DN 15, direct function D, flowage characteristics - L, nominal flowage KV 0.6m3/h, JKPOV 405 515 216 104, with time of delivery 14 days. d L DN d D H L H1 H2 15 G1/2” ∅ 170 200 90 240 255 20 G1” ∅ 230 270 120 320 335 H1 – for two-way design H2 – for three-way design Relationship graph between cone positioning and pressure ∆p two-way MRV KV Subservience three-way Meaning of labelled connection spots on the valve body Function D R Y Entry AB A A/B 0.16 – 1.0 1.6 – 2.5 4.0 – 6.0 Outlet A AB AB A B C Sealed B B – Change of technical parameters reserved.
© Copyright 2026 Paperzz