ES-500 Battery Energy Storage System (BESS) The ES-500 BESS is a fully integrated storage system designed to limit the customer’s capacity demand from their local utility and thereby reduce the peak load demand charge on their monthly electric bill. This Behind The Meter (BTM) system can shave your peak demand between 200 – 500kW per month. With kW demand charges ranging between $10 - $30 you could realize a savings of up to $100,000 per year. This is dependent upon local utility charges and customer monthly capacity demand. Without ES-500 ES-500 BESS includes: • • • • • • • Ten Li-Ion battery racks 500 kW Bi-directional inverter External mounted air conditioning system Novec-1230 fire suppression system IHI Energy Storage control rack running ESWare™ ES/Pilot software Security camera All configured in a 20’ ISO container Features of the ES-500 With ES-500 • Runs autonomously on its own – Set it and forget it • Comes with full system warranty o 2 years hardware/software o 1 year service Remotely manageable using your browser Ten year system life Requires Minimal Preventive Maintenance (PM) Customizable to your requirements • • • • IHI Energy Storage 1027 W. Jackson Blvd. Chicago, IL 60607 Phone: +1.312.724.7924 Email: [email protected] Web: www.ihi-energystorage.com ES-500 System Specifications: Absolute Power: Real Power: Reactive Power: Output Voltage: Frequency: Harmonic Distortion: AC to AC Efficiency: DC to DC Efficiency: Altitude: Cooling: Humidity: Ambient Temperature: Annual Throughput: Annual Cycle Count: Response Time: Communications: Environmental: Electrical: Safety EMC: 500kW 500 kW (Charge/Discharge) +/- 500kVAR 480VAC +/- 10%. 57 to 63 Hz, 60Hz Nominal. 50Hz Available <3% at rated power 87 % at rated power 93 % at rated power, 96% at C/4 < 1000m, de-rating of 1.2 % / 100 m >1000m apply as standard) Forced air, self-contained 0-95% -30 ºC to +50 ºC 300MWh per year 300 cycles, one cycle per day max. <250ms IEC61850, DNP3, Modbus/TCP, HTTP(S), SSH EN60529 NFPA 70: National Electrical Code® (Cond 1 Work Space Clearances Para 110.34) UL 1778 Emergency power off ANSI/BHMA A156.3 Egress Panic Hardware Underwriters Laboratories (UL) Recognized components where available Designed to CE mark requirements EN61000-6-2 Dimensions: Mass: Wind Load: Control System: 6.1m x 2.6m x 2.6m 13,500kg >38 m/s ESWare™ ES/Pilot Version 1.1 IHI Energy Storage 1027 W. Jackson Blvd. Chicago, IL 60607 Phone: +1.312.724.7924 Email: [email protected] Web: www.ihi-energystorage.com
© Copyright 2026 Paperzz