CT-V900-A Door HArDwAre New Version 5.1 Programmable outPuts reader 1 reader 2 out 1 (Default: Green LED) out 3 (Default: Green LED) out 2 (Default: Red LED) out 4 (Default: Red LED) out 5 (Default: Buzzer) out 6 (Default: Buzzer) In Constant Evolution to fulfill your needs Zone inPuts Without atZ (Zone doubling) in access control With atZ (Zone doubling) Z1 Default: Contact door 1 Z2 Z3 Default: REX door 1 Z4 Z5 Z6 Z7 Z8 Z9 Default: Contact door 2 Z10 Z11 Default: REX door 2 Z12 Z13 Z14 Z15 Z16 New features in CeNTAUr Version 5.1: Guard Tour Feature Live interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports. Asset Management Feature Whybuysomethingthatyoualreadyhave? Keeptrackofyourassetsandsavetimeand money.Findquicklywhoisinpossessionof yourassets.Areportcanbegeneratedand sentautomaticallyviaemail. Biometric Integration Centaurisapowerfulsolutionforareasrequiring enhancedsecuritybyauthenticatingfingerprints. Capturing,managingandtransferringbiometric dataisnoweffortlesswithworld-renowned fingerprintreaderssuchasCDVI’sDGID/W/US, L-1(model4G),Sagemandmore. relays Relay 1 (Onboard) Relay 2 (Onboard) adding one relay expansion adding a second relay expansion Relay 3 Relay 10 Relay 4 Relay 11 Relay 5 Relay 12 Relay 6 Relay 13 Relay 7 Relay 14 Relay 8 Relay 15 Relay 9 Relay 16 cdvi.ca CeNTAUr 5.1 now supports the following DVr manufacturers: • • • • • • • • • • • • • • • • • Capture Dahua Dedicated Micros Digiop Digital WatchDog Eneo Everfocus HIK Vision Infinova Microcom Milestone NUUO Samsung Sphere ViewGate Vivotek IP Camera Vivotek Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format. Improvements and built-in features: Centaur improvements: Parking Management Print or e-mail reports of your activities • Automaticallye-mailscheduledreports TheCentaurParkingManagementallowsyouto quicklyseehowmanyparkingplacesareused, bywhichuserandhowmanyparkingspacesare availableinrealtime. Tracktheaccessesofaspecificemployee,verify whoaccessedaspecificdoorataprecisedateand timeorcalculatehowmanyhoursofovertimeyou willpay.Centaurreportwizardallowsyoutocreate yourownreportseasily. • CardUsage/CardCounteroptions (useacardupto255timesonadoor) • Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput) Visitor Management CentaurVisitorManagementwillallowyoutosecurelycontrolthecomingsandgoingsof allvisitors. Locator Monitorthelocation(inside/outside)ofeachcard holderinreal-time.View/Printreportswithaclickof abutton.Obtaindetailedcardholderinformation withadouble-clickofthemousebutton.Excellent formuster-pointapplications. manufacturing access Control since 1985 Live Interactive Floor Plans • Createorimportupto512floorplans • Fulllibraryoficons(orcreateyourown) • Event-basedtrigger-actions sITe CoNFIgUrATIoN QUICK Form aCCess leVels and sChedules deFinition Access level 1:__________________________ Access level 3:__________________________ Schedule 1*: ___________________________ Schedule 3*: ___________________________ Period: S M T W T F S qqqqqqq Period: S M T W T F S qqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq H1 H2 H3 H4 qqqq H1 H2 H3 H4 qqqq Access level 2:__________________________ Access level 4:__________________________ Schedule 2*: ___________________________ Schedule 4*: ___________________________ Period: S M T W T F S qqqqqqq Period: S M T W T F S qqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq H1 H2 H3 H4 qqqq H1 H2 H3 H4 qqqq * HH:MM to HH:MM Card user name Card number Family : Number 1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: : cdvi.ca aCCess leVel INTEGRATED ACCESS CONTROL Key FeATUres IN VersIoN 5.1 • Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. • Asset Management, find quickly who is in possession of your assets and for how long. • Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more) • Alarm integration: Arm/disarm an alarm system with a double card swipe • Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail • Unassign card on period of inactivity (up to 365 days) • New DVR support (see the list on the front page) • Import/export users, cards and all related objects • Manually control doors from event window • New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application) • Play waves on alarm from the administration console • Additional filters in Locator • Now support DNS in the controller properties • Added French support in WavePlayer • Parking group: Reset parking count • SAP import for users/cards • When User/Visitor status is changed, it is now reflected on the cards • Support TELACCESS • Support DGLM magnetic stripe reader • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only) imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles. Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below: R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards cdvi.ca CT-V900-A Door HArDwAre INTEGRATED ACCESS CONTROL lite Cs-aC-lite Version 5.1 Project: _______________________________ standard Professional enterprise Door Name:_______________________ Free** Cs-aC-std Cs-aC-Pro* Cs-aC-ent* starter PaCk DOUBLE-DOOR OPTION sites 1 64 64 64 1 serial Ports 1 1 1 4 4 dial up connection Yes Yes Yes Yes Yes tCP/iP connection Yes Yes Yes Yes Yes Cards 512 2,048 per site 8,196 per site 16,384 per site 512 Controllers 16 32 per site 64 per site 256 per site 1 doors 16 128 per site 512 per site 2048 per site 8 elevator Control - Yes Yes Yes Yes elevator Cabs - 64 per site 128 per site 512 per site 2 Floors per cab - 64 64 64 64 Floor groups - 128 per site 128 per site 128 per site 128 dVr module - Yes Yes Yes Yes Visitor management - Yes Yes Yes Yes Parking management - Yes Yes Yes Yes guard tour - Yes Yes Yes Yes door Programming asset management - Yes Yes Yes Yes door type unlock schedule (optional) q Access (Most common setting) q Elevator q Entry Anti-passback (1 CT-V900-A only, 8 readers) q Exit Anti-passback (1 CT-V900-A only, 8 readers) q Global Entry Anti-passback (multiple doors) q Global Exit Anti-passback (multiple doors) q Parking Global Entry Anti-passback q Parking Global Exit Anti-passback q Two Card Rule Schedule time (HH:MM): __________________ * Comes with a workstation license (131,072 max.) (2,048 max.) (8,192 max.) (4,096 max.) (8,192 max.) (524,544 max.) (1,048,576 max.) (4,096 max.) (16,384 max.) (32,768 max.) (131,072 max.) (8,192 max.) (32,768 max.) (8,192 max.) (8,192 max.) ** New Free from our web site, www.cdvi.ca Security dongle not required every Centaur edition includes a Centaur server with an administration console plus all these software modules: Pro-report with tracker: On demand, scheduled or customized reports FrontView: Live interactive floor plans Frontguard: Display real-time visual authentication Frontdesk: Create, modify, delete and print cards, include Photo-ID locator: Monitor real-time location of each card holder WavePlayer: Play a sound on any system event Door contact � Surface � Flush Door contact Electromagnet � 24V � 12V � � Flush � Electromagnet � 24V � 12V � Door Strike � 24V � 12V � Fail Safe � Fail Secure REQUEST-TO-EXIT (REX) � Motion Detector � Pull Station � Push Button � Push Bar/Crash Bar READING DEVICE (ENTRY) � Reader Technology:_______________ � Keypad Technology:_______________ READING DEVICE (EXIT) � Reader Technology:_______________ � Keypad Technology:_______________ Fixed Door � � Fixed Door Days: q Unlock on late open Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules. q Time and attendance q Sign-Out reader (Visitor) S M T W T F S q qqqqqq interlock (man-trap) With door (input): _________________________ options Workstation license (Cs-WsliC): (Ignore the unlock schedule until the first person arrives) enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1 cdvi.ca � Surface cdvi.ca Centaur System Architecture JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT Printer CT-V900-A END POINT of the RS-485 E-bus network Bias High/Low Jumpers A+= High B-= High CA-A480-A CA-A480-A Relay Expansion Module CA-A460-P (Max. 2 per CT-V900-A) cdvi.ca R1/D1 R1/D0 R1/0V R1/+5V RL16 DRM MODULE RL15 RL14 RL13 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 R1/D1 R1/D0 R1/0V R1/+5V R2/D1 R2/D0 R2/0V R2/+5V OUT2 OUT1 OUT4 OUT3 SP +12V R1/KPD R1/KPC R1/KPB R1/KPA SP +12V R2/KPD R2/KPC R2/KPB R2/KPA NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 RL12 2 3 4 5 6 7 8 1 2 3 PWR OFF/ON N/D Elevator Controller CA-A480-A (Max. 8 per CT-V900-A) RL11 DRM ENABLED 1 ON 4 5 6 7 8 ON OFF OFF ON OFF 6 7 8 In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A. The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before. ON LCD Display CK-TRAK-L (Max. 8 per CT-V900-A) ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON ADDRESS 8 OUT2 OUT1 RL10 RLY OFF/ON 8 ADDRESS 4 R2/D1 R2/D0 R2/0V R2/+5V RL9 RLY COMMS 7 ADDRESS 2 6 ADDRESS 1 5 RLY OFF/ON 4 PWR OFF/ON 3 DRM ENABLED 2 ADDRESS 8 1 ADDRESS 4 OUT4 OUT3 RL8 Addressable dipswitch RLY COMMS SP +12V R1/KPD R1/KPC R1/KPB R1/KPA RL7 1 2 3 4 5 6 7 8 RL6 ON STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL4 RL5 Addressable dipswitch ADDRESS 2 SP +12V R2/KPD R2/KPC R2/KPB R2/KPA Elevator Controller CA - A480 - P RL3 1 2 3 4 5 6 7 8 ON RL4 NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 RL12 RL2 RL3 BACKUP2 BACKUP1 5 PULSE 5&6 ADD 2 L2 Energize ADD 1 L1 Energize 4 RL11 Addressable dipswitch ADDRESS 1 Addressable dipswitch 3 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL10 Bias High/Low A+= High B-= High N/D TMP TMP Bias High/Low A+= Low B-= Low 2 TMP TMP BACKUP2 A+ BGND TX RX E-BUS E-bus Network Jumper settings EOL= ON 1 RL9 FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX A+ BGND TX RX E-BUS PULSE 5&6 3 RL8 350mA/700mA EOL Bias High/Low A+= High B-= High BACKUP1 EOL STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL7 B LOW HIGH Bias High/Low A+= High B-= High ADD 2 2 LOW HIGH BA+ READER#1 DATA 3 Elevator Controller CA - A480 - P RL6 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 E-bus Network Jumper settings EOL= ON L2 Energize to other Ct-V900-a controllers AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA EOL RL5 A+ BGND TAMPER TAMPER E-bus Network Jumper settings EOL= OFF L1 Energize Furthest modules can be up to 1220m (4000ft) away from the CT-V900-A JP120 350mA/700mA 4 5 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC AC BAT+ BATV+ V+ VVOUT5 OUT6 + 1 STATUS LOCK#2 1 2 3 4 5 6 7 8 to PC Centaur server See diagram above D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 ON E- bus N Etwork ModulE CapaCity CA-A470-A 2-Door Expansion Module 2 LOW HIGH BA+ READER#1 DATA FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation. CA-A470-A LOCK#1 READER#2 DATA 350mA/700mA EOL E-bus Network Jumper settings EOL= OFF ADD 1 Centaur Door Controller Burglar Alarm Integration START POINT of the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point) AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D B LOW HIGH RL2 IP Camera ON Pro-report: Print detailed report FrontView: Live interactive floor plans Frontguard: Display real-time visual authentication Frontdesk: Create, modify, delete and print cards locator: Monitor card holder location in real-time WavePlayer: Play a sound on any system event Direct or dial-up (modem) connections also supported JP120 350mA/700mA 4 5 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC AC BAT+ BATV+ V+ VVOUT5 OUT6 + 1 STATUS LOCK#2 1 2 3 4 5 6 7 8 Centaur built-in modules: CA-A470-A 2-Door Expansion Module LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 RL1 Digital Video Recorder (DVR) E-BUS A+ BGND TAMPER TAMPER RL1 CA-A470-A AC AC BAT+ BAT+12V +12V GND GND FC FC RL16 E-BUS DRM MODULE 2-Door Controller RL15 CT-V900-A RL14 Optional Workstation(s) E-bus Network Jumper settings EOL= OFF RL13 (Also direct connection can be use) COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 TCP/IP Connection (LAN/WAN) OFF This permits you to have a 30m (100ft) cable run instead of 914m (3000ft). 2-Door Expansion Module CA-A470-A (Max. 3 per CT-V900-A) cdvi.ca sITe CoNFIgUrATIoN QUICK Form JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 CONTROLLER NETWORK USING DIRECT CONNECT CONFIGURATION Company name: ___________________________ Contact 2: ________________________________ Address: _________________________________ Tel: ______________________________________ City: _____________________________________ Contact 3: ________________________________ State: ____________________________________ Tel: ______________________________________ Zip Code: _________________________________ Contact 1: ________________________________ Dealer: ________________________________ Tel: ______________________________________ Tel: ___________________________________ PC (Centaur server) to controller communication type RS-232 7.6m (25ft) max. At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF START POINT of the RS-485 controller network. (Furthest module can be up to 1220m (4000ft) from start point) Controller Network Jumper settings EOL= ON Bias High/Low Jumpers A+= Low B-= Low At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CT-V900-A CT-V900-A CUT VIEW CT-V900-A 2-Door Controller Addressable dipswitch ADD 1 ADD 2 ADD 4 ADD 8 ADD 16 ADD 32 9.6K/19.2K DEF/RUN 1 2 3 4 5 6 7 8 ON OFF ADDRESSABLE DIPSWITCH CT-V900-A Controller Network Jumper settings EOL= OFF Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller ADD 8 ADD 16 4 5 ADD 32 ADD 4 3 DEF/RUN ADD 2 2 9.6K/19.2K ADD 1 1 6 7 8 E-BUS NETWORK JUMPERS CONTROLLER NETWORK JUMPERS Addressable dipswitch qDirect serial port qRS-232 NULL modem cable qDial Up (modem) Modem number: ____________________________________ qTCP/IP IP Address: ________________________________________ doors name EOL Controller Network Jumper settings EOL= ON Bias High/Low Jumpers A+= High B-= High ADD 32 DEF/RUN 9.6K/19.2K ADD 8 ADD 16 ADD 4 ADD 2 ADD 1 1 2 3 4 5 6 7 8 OFF door strike maglock Pull station q Exit q q q q q 2: q Entry q Exit q q q q q 3: q Entry q Exit q q q q q 4: q Entry q Exit q q q q q 5: q Entry q Exit q q q q q 6: q Entry q Exit q q q q q 7: q Entry q Exit q q q q q 8: q Entry q Exit q q q q q installation diagram 2 Reader/Keypads per CT-V900-A or CA-A470-A Jumper set to EOL OFF EOL Jumper set to EOL ON CT-V900-A Jumper set to HIGH 2-Door Controller HIGH LOW HIGH LOW Addressable dipswitch ON request to exit q Entry Example of Jumper Settings CT-V900-A door Contact 1: ON OFF reader qConverter (25’ and more) Jumper set to LOW END POINT of the RS-485 controller network cdvi.ca Ct-V900-a (1) Ct-a470-a (2) Ct-a470-a (1) Ct-a470-a (3) Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ cdvi.ca HArDwAre LIsT Proximity Card and badges qCS: Clamshell card Controller Network Jumper settings EOL= ON qISO: Printable card qBTAG: Blue polycarbonate key ring badge Bias High/Low Jumpers A+= Low B-= Low qPP: Stylish black polycarbonate tear drop badge rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI24 (24VCC) qARI (12VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI24 (24VCC) qAGI (12VCC) Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller 9.6K/19.2K DEF/RUN 3 ADD 32 2 ADD 8 1 ADD 16 Addressable dipswitch ADD 4 eleCtromagnets GND TX RX GND BA+ GND +12V CT-V900-A ADD 2 qAGCC (12VCC) 4 5 6 7 8 ON V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc OFF V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc Pull station loCk Control module - Ca-a110-P door ContaCt CT-V900-A Controller Network Jumper settings EOL= OFF Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller Addressable dipswitch 9.6K/19.2K DEF/RUN 3 ADD 32 2 ADD 8 1 ADD 16 ADD 4 reQuest to exit ADD 2 qSurface mount ADD 1 qFlush mount START POINT of the RS-485 controller network. (Furthest modules can be up to 1220m (4000ft) from start point) Controller Network Jumper settings EOL= OFF ADD 1 Strike EFF-EFF continous fail secure: RS-232 7.6m (25ft) max. POWER qBP: leather key ring badge TRANSMIT galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper) JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 CONTROLLER NETWORK USING A CA-A360-A CONVERTER RECEIVE 26-bits Wiegand keyPads CA-A360-A Quantity POSITION ProduCts 4 5 6 7 8 ON Motion detector OFF BPEST: Touch-to-Exit button CT-V900-A BEI: Stainless steel touch-sensitive handle POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm) EST: Transforms any metallic surface into a request-to-exit device Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller Addressable dipswitch 9.6K/19.2K DEF/RUN 3 ADD 8 ADD 4 2 ADD 32 ADD 2 1 ADD 16 ADD 1 rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other: Controller Network Jumper settings EOL= ON 4 5 6 7 8 ON OFF END POINT of the RS-485 controller network cdvi.ca cdvi.ca Since the converter is now the closest to the server, it is the START POINT. The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default. HArDwAre LIsT JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 E-BUS NETWORK START POINT of the RS-485 E-bus network (Furthest module can be up to 1220m (4000ft) from start point) At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF E-bus Network Jumper settings EOL= ON At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CT-V900-A Company Name: ________________________ Name: ________________________________ Address: ______________________________ Title: __________________________________ City: __________________________________ Tel: ___________________________________ State: _________________________________ Cell: __________________________________ Zip Code: ______________________________ E-mail: ________________________________ door tyPe Controlled entry with Free exit To access control server 2-Door Controller Bias High/Low Jumpers A+= Low B-= Low CA-A480-A END POINT of the RS-485 E-bus network Request to exit Entry reader E-BUS TX RX E-BUS JP120 350mA/700mA 4 5 + 1 STATUS LOCK#2 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA 2 LOW HIGH BA+ READER#1 DATA 3 EOL R1/D1 R1/D0 R1/0V R1/+5V TMP TMP E-bus Network Jumper settings EOL= ON Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Addressable dipswitch Addressable dipswitch Addressable dipswitch Addressable dipswitch 4 5 N/D 3 BACKUP2 2 BACKUP1 1 6 7 8 ON OFF OFF Entry reader * Can be replace by electromagnet * Can be replace by electromagnet ProduCts 2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) PULSE 5&6 8 L2 Energize 7 ADD 2 6 ADD 1 5 ON L1 Energize 4 N/D 3 BACKUP2 2 PULSE 5&6 1 BACKUP1 8 L2 Energize 7 ADD 2 OFF L1 Energize 6 ON ADD 1 5 RLY OFF/ON 4 PWR OFF/ON 3 DRM ENABLED 2 ADDRESS 8 1 RLY COMMS 8 ADDRESS 4 7 ADDRESS 2 6 ADDRESS 1 RLY OFF/ON PWR OFF/ON 5 DRM ENABLED ADDRESS 4 ADDRESS 8 ADDRESS 2 RLY COMMS ADDRESS 1 4 Door strike* Door strike* TMP TMP E-bus Network Jumper settings EOL= OFF 3 Door strike* A+ BGND E-bus Network Jumper settings EOL= OFF 2 Protected Door Entry reader TX RX E-BUS E-bus Network Jumper settings EOL= OFF 1 Employees Door Exit reader AC AC BAT+ BATV+ V+ VVOUT5 OUT6 OUT2 OUT1 3 EOL LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 A+ BGND R2/D1 R2/D0 R2/0V R2/+5V 2 LOW HIGH BA+ READER#1 DATA OUT4 OUT3 AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA SP +12V R1/KPD R1/KPC R1/KPB R1/KPA JP120 350mA/700mA 4 5 + 1 STATUS LOCK#2 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR SP +12V R2/KPD R2/KPC R2/KPB R2/KPA LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 R1/D1 R1/D0 R1/0V R1/+5V RL12 OUT2 OUT1 RL11 R2/D1 R2/D0 R2/0V R2/+5V ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL10 OUT4 OUT3 RL9 SP +12V R1/KPD R1/KPC R1/KPB R1/KPA RL8 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 RL7 SP +12V R2/KPD R2/KPC R2/KPB R2/KPA RL16 DRM MODULE RL15 RL16 RL15 RL14 RL13 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL6 CA-A470-A 2-Door Expansion Module 1 2 3 4 5 6 7 8 RL5 Door contact CA-A470-A AC AC BAT+ BATV+ V+ VVOUT5 OUT6 ON RL12 CA-A470-A 2-Door Expansion Module 1 2 3 4 5 6 7 8 RL11 CA-A470-A NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 ON ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON Elevator Controller CA - A480 - P 1 2 3 4 5 6 7 8 RL10 FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX ON RL9 350mA/700mA EOL RL4 1 2 3 4 5 6 7 8 RL8 ON RL4 RL7 B LOW HIGH RL3 RL3 STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL6 NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 RL2 RL2 Elevator Controller CA - A480 - P A+ BGND TAMPER TAMPER RL1 RL1 RL5 DRM MODULE FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX RL14 350mA/700mA EOL RL13 B LOW HIGH COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A) ON OFF Proximity reader With multiPle ProtoColes built-in DGLP FN WLC: Multi-Technology Polycarbonate proximity reader DGLP WLC: Multi-Technology Polycarbonate proximity reader DGLI F WLC: Multi-Technology Stainless steel proximity reader DGLI WLC: Multi-Technology Stainless steel proximity reader cdvi.ca To next controller CT-V900-A Controller #1 Request to exit Front Door RS-485 Communication bus AC CT-V900 Controller #1 CA-A480-A E-BUS COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 To access control server To next controller AC CT-V900-A A+ BGND TAMPER TAMPER Controlled entry and exit cdvi.ca Qty Centaur System Architecture JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT Printer CT-V900-A END POINT of the RS-485 E-bus network Bias High/Low Jumpers A+= High B-= High CA-A480-A CA-A480-A Relay Expansion Module CA-A460-P (Max. 2 per CT-V900-A) cdvi.ca R1/D1 R1/D0 R1/0V R1/+5V RL16 DRM MODULE RL15 RL14 RL13 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 R1/D1 R1/D0 R1/0V R1/+5V R2/D1 R2/D0 R2/0V R2/+5V OUT2 OUT1 OUT4 OUT3 SP +12V R1/KPD R1/KPC R1/KPB R1/KPA SP +12V R2/KPD R2/KPC R2/KPB R2/KPA NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 RL12 2 3 4 5 6 7 8 1 2 3 PWR OFF/ON N/D Elevator Controller CA-A480-A (Max. 8 per CT-V900-A) RL11 DRM ENABLED 1 ON 4 5 6 7 8 ON OFF OFF ON OFF 6 7 8 In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A. The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before. ON LCD Display CK-TRAK-L (Max. 8 per CT-V900-A) ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON ADDRESS 8 OUT2 OUT1 RL10 RLY OFF/ON 8 ADDRESS 4 R2/D1 R2/D0 R2/0V R2/+5V RL9 RLY COMMS 7 ADDRESS 2 6 ADDRESS 1 5 RLY OFF/ON 4 PWR OFF/ON 3 DRM ENABLED 2 ADDRESS 8 1 ADDRESS 4 OUT4 OUT3 RL8 Addressable dipswitch RLY COMMS SP +12V R1/KPD R1/KPC R1/KPB R1/KPA RL7 1 2 3 4 5 6 7 8 RL6 ON STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL4 RL5 Addressable dipswitch ADDRESS 2 SP +12V R2/KPD R2/KPC R2/KPB R2/KPA Elevator Controller CA - A480 - P RL3 1 2 3 4 5 6 7 8 ON RL4 NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 RL12 RL2 RL3 BACKUP2 BACKUP1 5 PULSE 5&6 ADD 2 L2 Energize ADD 1 L1 Energize 4 RL11 Addressable dipswitch ADDRESS 1 Addressable dipswitch 3 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL10 Bias High/Low A+= High B-= High N/D TMP TMP Bias High/Low A+= Low B-= Low 2 TMP TMP BACKUP2 A+ BGND TX RX E-BUS E-bus Network Jumper settings EOL= ON 1 RL9 FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX A+ BGND TX RX E-BUS PULSE 5&6 3 RL8 350mA/700mA EOL Bias High/Low A+= High B-= High BACKUP1 EOL STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL7 B LOW HIGH Bias High/Low A+= High B-= High ADD 2 2 LOW HIGH BA+ READER#1 DATA 3 Elevator Controller CA - A480 - P RL6 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 E-bus Network Jumper settings EOL= ON L2 Energize to other Ct-V900-a controllers AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA EOL RL5 A+ BGND TAMPER TAMPER E-bus Network Jumper settings EOL= OFF L1 Energize Furthest modules can be up to 1220m (4000ft) away from the CT-V900-A JP120 350mA/700mA 4 5 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC AC BAT+ BATV+ V+ VVOUT5 OUT6 + 1 STATUS LOCK#2 1 2 3 4 5 6 7 8 to PC Centaur server See diagram above D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 ON E- bus N Etwork ModulE CapaCity CA-A470-A 2-Door Expansion Module 2 LOW HIGH BA+ READER#1 DATA FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation. CA-A470-A LOCK#1 READER#2 DATA 350mA/700mA EOL E-bus Network Jumper settings EOL= OFF ADD 1 Centaur Door Controller Burglar Alarm Integration START POINT of the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point) AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D B LOW HIGH RL2 IP Camera ON Pro-report: Print detailed report FrontView: Live interactive floor plans Frontguard: Display real-time visual authentication Frontdesk: Create, modify, delete and print cards locator: Monitor card holder location in real-time WavePlayer: Play a sound on any system event Direct or dial-up (modem) connections also supported JP120 350mA/700mA 4 5 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC AC BAT+ BATV+ V+ VVOUT5 OUT6 + 1 STATUS LOCK#2 1 2 3 4 5 6 7 8 Centaur built-in modules: CA-A470-A 2-Door Expansion Module LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 RL1 Digital Video Recorder (DVR) E-BUS A+ BGND TAMPER TAMPER RL1 CA-A470-A AC AC BAT+ BAT+12V +12V GND GND FC FC RL16 E-BUS DRM MODULE 2-Door Controller RL15 CT-V900-A RL14 Optional Workstation(s) E-bus Network Jumper settings EOL= OFF RL13 (Also direct connection can be use) COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 TCP/IP Connection (LAN/WAN) OFF This permits you to have a 30m (100ft) cable run instead of 914m (3000ft). 2-Door Expansion Module CA-A470-A (Max. 3 per CT-V900-A) cdvi.ca sITe CoNFIgUrATIoN QUICK Form JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 CONTROLLER NETWORK USING DIRECT CONNECT CONFIGURATION Company name: ___________________________ Contact 2: ________________________________ Address: _________________________________ Tel: ______________________________________ City: _____________________________________ Contact 3: ________________________________ State: ____________________________________ Tel: ______________________________________ Zip Code: _________________________________ Contact 1: ________________________________ Dealer: ________________________________ Tel: ______________________________________ Tel: ___________________________________ PC (Centaur server) to controller communication type RS-232 7.6m (25ft) max. At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF START POINT of the RS-485 controller network. (Furthest module can be up to 1220m (4000ft) from start point) Controller Network Jumper settings EOL= ON Bias High/Low Jumpers A+= Low B-= Low At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CT-V900-A CT-V900-A CUT VIEW CT-V900-A 2-Door Controller Addressable dipswitch ADD 1 ADD 2 ADD 4 ADD 8 ADD 16 ADD 32 9.6K/19.2K DEF/RUN 1 2 3 4 5 6 7 8 ON OFF ADDRESSABLE DIPSWITCH CT-V900-A Controller Network Jumper settings EOL= OFF Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller ADD 8 ADD 16 4 5 ADD 32 ADD 4 3 DEF/RUN ADD 2 2 9.6K/19.2K ADD 1 1 6 7 8 E-BUS NETWORK JUMPERS CONTROLLER NETWORK JUMPERS Addressable dipswitch qDirect serial port qRS-232 NULL modem cable qDial Up (modem) Modem number: ____________________________________ qTCP/IP IP Address: ________________________________________ doors name EOL Controller Network Jumper settings EOL= ON Bias High/Low Jumpers A+= High B-= High ADD 32 DEF/RUN 9.6K/19.2K ADD 8 ADD 16 ADD 4 ADD 2 ADD 1 1 2 3 4 5 6 7 8 OFF door strike maglock Pull station q Exit q q q q q 2: q Entry q Exit q q q q q 3: q Entry q Exit q q q q q 4: q Entry q Exit q q q q q 5: q Entry q Exit q q q q q 6: q Entry q Exit q q q q q 7: q Entry q Exit q q q q q 8: q Entry q Exit q q q q q installation diagram 2 Reader/Keypads per CT-V900-A or CA-A470-A Jumper set to EOL OFF EOL Jumper set to EOL ON CT-V900-A Jumper set to HIGH 2-Door Controller HIGH LOW HIGH LOW Addressable dipswitch ON request to exit q Entry Example of Jumper Settings CT-V900-A door Contact 1: ON OFF reader qConverter (25’ and more) Jumper set to LOW END POINT of the RS-485 controller network cdvi.ca Ct-V900-a (1) Ct-a470-a (2) Ct-a470-a (1) Ct-a470-a (3) Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ Door: ____________ cdvi.ca sITe CoNFIgUrATIoN QUICK Form aCCess leVels and sChedules deFinition Access level 1:__________________________ Access level 3:__________________________ Schedule 1*: ___________________________ Schedule 3*: ___________________________ Period: S M T W T F S qqqqqqq Period: S M T W T F S qqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq H1 H2 H3 H4 qqqq H1 H2 H3 H4 qqqq Access level 2:__________________________ Access level 4:__________________________ Schedule 2*: ___________________________ Schedule 4*: ___________________________ Period: S M T W T F S qqqqqqq Period: S M T W T F S qqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq Door: 1 2 3 4 5 6 7 8 qqqqqqqq H1 H2 H3 H4 qqqq H1 H2 H3 H4 qqqq * HH:MM to HH:MM Card user name Card number Family : Number 1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: : cdvi.ca aCCess leVel INTEGRATED ACCESS CONTROL Key FeATUres IN VersIoN 5.1 • Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. • Asset Management, find quickly who is in possession of your assets and for how long. • Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more) • Alarm integration: Arm/disarm an alarm system with a double card swipe • Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail • Unassign card on period of inactivity (up to 365 days) • New DVR support (see the list on the front page) • Import/export users, cards and all related objects • Manually control doors from event window • New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application) • Play waves on alarm from the administration console • Additional filters in Locator • Now support DNS in the controller properties • Added French support in WavePlayer • Parking group: Reset parking count • SAP import for users/cards • When User/Visitor status is changed, it is now reflected on the cards • Support TELACCESS • Support DGLM magnetic stripe reader • Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only) imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles. Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below: R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards cdvi.ca HArDwAre LIsT JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 E-BUS NETWORK START POINT of the RS-485 E-bus network (Furthest module can be up to 1220m (4000ft) from start point) At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF E-bus Network Jumper settings EOL= ON At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CT-V900-A Company Name: ________________________ Name: ________________________________ Address: ______________________________ Title: __________________________________ City: __________________________________ Tel: ___________________________________ State: _________________________________ Cell: __________________________________ Zip Code: ______________________________ E-mail: ________________________________ door tyPe Controlled entry with Free exit To access control server 2-Door Controller Bias High/Low Jumpers A+= Low B-= Low CA-A480-A END POINT of the RS-485 E-bus network Request to exit Entry reader E-BUS TX RX E-BUS JP120 350mA/700mA 4 5 + 1 STATUS LOCK#2 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA 2 LOW HIGH BA+ READER#1 DATA 3 EOL R1/D1 R1/D0 R1/0V R1/+5V TMP TMP E-bus Network Jumper settings EOL= ON Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Bias High/Low A+= High B-= High Addressable dipswitch Addressable dipswitch Addressable dipswitch Addressable dipswitch 4 5 N/D 3 BACKUP2 2 BACKUP1 1 6 7 8 ON OFF OFF Entry reader * Can be replace by electromagnet * Can be replace by electromagnet ProduCts 2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) PULSE 5&6 8 L2 Energize 7 ADD 2 6 ADD 1 5 ON L1 Energize 4 N/D 3 BACKUP2 2 PULSE 5&6 1 BACKUP1 8 L2 Energize 7 ADD 2 OFF L1 Energize 6 ON ADD 1 5 RLY OFF/ON 4 PWR OFF/ON 3 DRM ENABLED 2 ADDRESS 8 1 RLY COMMS 8 ADDRESS 4 7 ADDRESS 2 6 ADDRESS 1 RLY OFF/ON PWR OFF/ON 5 DRM ENABLED ADDRESS 4 ADDRESS 8 ADDRESS 2 RLY COMMS ADDRESS 1 4 Door strike* Door strike* TMP TMP E-bus Network Jumper settings EOL= OFF 3 Door strike* A+ BGND E-bus Network Jumper settings EOL= OFF 2 Protected Door Entry reader TX RX E-BUS E-bus Network Jumper settings EOL= OFF 1 Employees Door Exit reader AC AC BAT+ BATV+ V+ VVOUT5 OUT6 OUT2 OUT1 3 EOL LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 A+ BGND R2/D1 R2/D0 R2/0V R2/+5V 2 LOW HIGH BA+ READER#1 DATA OUT4 OUT3 AC OK AUX OK COMM CHECK BATT BATT TRBL SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#2 DATA SP +12V R1/KPD R1/KPC R1/KPB R1/KPA JP120 350mA/700mA 4 5 + 1 STATUS LOCK#2 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR SP +12V R2/KPD R2/KPC R2/KPB R2/KPA LOCK#1 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 R1/D1 R1/D0 R1/0V R1/+5V RL12 OUT2 OUT1 RL11 R2/D1 R2/D0 R2/0V R2/+5V ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL10 OUT4 OUT3 RL9 SP +12V R1/KPD R1/KPC R1/KPB R1/KPA RL8 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 RL7 SP +12V R2/KPD R2/KPC R2/KPB R2/KPA RL16 DRM MODULE RL15 RL16 RL15 RL14 RL13 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL6 CA-A470-A 2-Door Expansion Module 1 2 3 4 5 6 7 8 RL5 Door contact CA-A470-A AC AC BAT+ BATV+ V+ VVOUT5 OUT6 ON RL12 CA-A470-A 2-Door Expansion Module 1 2 3 4 5 6 7 8 RL11 CA-A470-A NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 ON ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON Elevator Controller CA - A480 - P 1 2 3 4 5 6 7 8 RL10 FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX ON RL9 350mA/700mA EOL RL4 1 2 3 4 5 6 7 8 RL8 ON RL4 RL7 B LOW HIGH RL3 RL3 STATUS FREE ACCESS COMM FAILURE BATT TROUBLE RL6 NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 RL2 RL2 Elevator Controller CA - A480 - P A+ BGND TAMPER TAMPER RL1 RL1 RL5 DRM MODULE FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX RL14 350mA/700mA EOL RL13 B LOW HIGH COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 AC AC BAT+ BAT+12V +12V GND GND FC FC A LOW HIGH CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A) ON OFF Proximity reader With multiPle ProtoColes built-in DGLP FN WLC: Multi-Technology Polycarbonate proximity reader DGLP WLC: Multi-Technology Polycarbonate proximity reader DGLI F WLC: Multi-Technology Stainless steel proximity reader DGLI WLC: Multi-Technology Stainless steel proximity reader cdvi.ca To next controller CT-V900-A Controller #1 Request to exit Front Door RS-485 Communication bus AC CT-V900 Controller #1 CA-A480-A E-BUS COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 To access control server To next controller AC CT-V900-A A+ BGND TAMPER TAMPER Controlled entry and exit cdvi.ca Qty HArDwAre LIsT Proximity Card and badges qCS: Clamshell card Controller Network Jumper settings EOL= ON qISO: Printable card qBTAG: Blue polycarbonate key ring badge Bias High/Low Jumpers A+= Low B-= Low qPP: Stylish black polycarbonate tear drop badge rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI24 (24VCC) qARI (12VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI24 (24VCC) qAGI (12VCC) Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller 9.6K/19.2K DEF/RUN 3 ADD 32 2 ADD 8 1 ADD 16 Addressable dipswitch ADD 4 eleCtromagnets GND TX RX GND BA+ GND +12V CT-V900-A ADD 2 qAGCC (12VCC) 4 5 6 7 8 ON V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc OFF V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc Pull station loCk Control module - Ca-a110-P door ContaCt CT-V900-A Controller Network Jumper settings EOL= OFF Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller Addressable dipswitch 9.6K/19.2K DEF/RUN 3 ADD 32 2 ADD 8 1 ADD 16 ADD 4 reQuest to exit ADD 2 qSurface mount ADD 1 qFlush mount START POINT of the RS-485 controller network. (Furthest modules can be up to 1220m (4000ft) from start point) Controller Network Jumper settings EOL= OFF ADD 1 Strike EFF-EFF continous fail secure: RS-232 7.6m (25ft) max. POWER qBP: leather key ring badge TRANSMIT galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper) JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS: EXAMPLE OF RS-485 CONTROLLER NETWORK USING A CA-A360-A CONVERTER RECEIVE 26-bits Wiegand keyPads CA-A360-A Quantity POSITION ProduCts 4 5 6 7 8 ON Motion detector OFF BPEST: Touch-to-Exit button CT-V900-A BEI: Stainless steel touch-sensitive handle POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm) EST: Transforms any metallic surface into a request-to-exit device Bias High/Low Jumpers A+= High B-= High CT-V900-A 2-Door Controller Addressable dipswitch 9.6K/19.2K DEF/RUN 3 ADD 8 ADD 4 2 ADD 32 ADD 2 1 ADD 16 ADD 1 rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other: Controller Network Jumper settings EOL= ON 4 5 6 7 8 ON OFF END POINT of the RS-485 controller network cdvi.ca cdvi.ca Since the converter is now the closest to the server, it is the START POINT. The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default. CT-V900-A Door HArDwAre INTEGRATED ACCESS CONTROL lite Cs-aC-lite Version 5.1 Project: _______________________________ standard Professional enterprise Door Name:_______________________ Free** Cs-aC-std Cs-aC-Pro* Cs-aC-ent* starter PaCk DOUBLE-DOOR OPTION sites 1 64 64 64 1 serial Ports 1 1 1 4 4 dial up connection Yes Yes Yes Yes Yes tCP/iP connection Yes Yes Yes Yes Yes Cards 512 2,048 per site 8,196 per site 16,384 per site 512 Controllers 16 32 per site 64 per site 256 per site 1 doors 16 128 per site 512 per site 2048 per site 8 elevator Control - Yes Yes Yes Yes elevator Cabs - 64 per site 128 per site 512 per site 2 Floors per cab - 64 64 64 64 Floor groups - 128 per site 128 per site 128 per site 128 dVr module - Yes Yes Yes Yes Visitor management - Yes Yes Yes Yes Parking management - Yes Yes Yes Yes guard tour - Yes Yes Yes Yes door Programming asset management - Yes Yes Yes Yes door type unlock schedule (optional) q Access (Most common setting) q Elevator q Entry Anti-passback (1 CT-V900-A only, 8 readers) q Exit Anti-passback (1 CT-V900-A only, 8 readers) q Global Entry Anti-passback (multiple doors) q Global Exit Anti-passback (multiple doors) q Parking Global Entry Anti-passback q Parking Global Exit Anti-passback q Two Card Rule Schedule time (HH:MM): __________________ * Comes with a workstation license (131,072 max.) (2,048 max.) (8,192 max.) (4,096 max.) (8,192 max.) (524,544 max.) (1,048,576 max.) (4,096 max.) (16,384 max.) (32,768 max.) (131,072 max.) (8,192 max.) (32,768 max.) (8,192 max.) (8,192 max.) ** New Free from our web site, www.cdvi.ca Security dongle not required every Centaur edition includes a Centaur server with an administration console plus all these software modules: Pro-report with tracker: On demand, scheduled or customized reports FrontView: Live interactive floor plans Frontguard: Display real-time visual authentication Frontdesk: Create, modify, delete and print cards, include Photo-ID locator: Monitor real-time location of each card holder WavePlayer: Play a sound on any system event Door contact � Surface � Flush Door contact Electromagnet � 24V � 12V � � Flush � Electromagnet � 24V � 12V � Door Strike � 24V � 12V � Fail Safe � Fail Secure REQUEST-TO-EXIT (REX) � Motion Detector � Pull Station � Push Button � Push Bar/Crash Bar READING DEVICE (ENTRY) � Reader Technology:_______________ � Keypad Technology:_______________ READING DEVICE (EXIT) � Reader Technology:_______________ � Keypad Technology:_______________ Fixed Door � � Fixed Door Days: q Unlock on late open Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules. q Time and attendance q Sign-Out reader (Visitor) S M T W T F S q qqqqqq interlock (man-trap) With door (input): _________________________ options Workstation license (Cs-WsliC): (Ignore the unlock schedule until the first person arrives) enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1 cdvi.ca � Surface cdvi.ca CT-V900-A Door HArDwAre New Version 5.1 Programmable outPuts reader 1 reader 2 out 1 (Default: Green LED) out 3 (Default: Green LED) out 2 (Default: Red LED) out 4 (Default: Red LED) out 5 (Default: Buzzer) out 6 (Default: Buzzer) In Constant Evolution to fulfill your needs Zone inPuts Without atZ (Zone doubling) in access control With atZ (Zone doubling) Z1 Default: Contact door 1 Z2 Z3 Default: REX door 1 Z4 Z5 Z6 Z7 Z8 Z9 Default: Contact door 2 Z10 Z11 Default: REX door 2 Z12 Z13 Z14 Z15 Z16 New features in CeNTAUr Version 5.1: Guard Tour Feature Live interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports. Asset Management Feature Whybuysomethingthatyoualreadyhave? Keeptrackofyourassetsandsavetimeand money.Findquicklywhoisinpossessionof yourassets.Areportcanbegeneratedand sentautomaticallyviaemail. Biometric Integration Centaurisapowerfulsolutionforareasrequiring enhancedsecuritybyauthenticatingfingerprints. Capturing,managingandtransferringbiometric dataisnoweffortlesswithworld-renowned fingerprintreaderssuchasCDVI’sDGID/W/US, L-1(model4G),Sagemandmore. relays Relay 1 (Onboard) Relay 2 (Onboard) adding one relay expansion adding a second relay expansion Relay 3 Relay 10 Relay 4 Relay 11 Relay 5 Relay 12 Relay 6 Relay 13 Relay 7 Relay 14 Relay 8 Relay 15 Relay 9 Relay 16 cdvi.ca CeNTAUr 5.1 now supports the following DVr manufacturers: • • • • • • • • • • • • • • • • • Capture Dahua Dedicated Micros Digiop Digital WatchDog Eneo Everfocus HIK Vision Infinova Microcom Milestone NUUO Samsung Sphere ViewGate Vivotek IP Camera Vivotek Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format. Improvements and built-in features: Centaur improvements: Parking Management Print or e-mail reports of your activities • Automaticallye-mailscheduledreports TheCentaurParkingManagementallowsyouto quicklyseehowmanyparkingplacesareused, bywhichuserandhowmanyparkingspacesare availableinrealtime. Tracktheaccessesofaspecificemployee,verify whoaccessedaspecificdoorataprecisedateand timeorcalculatehowmanyhoursofovertimeyou willpay.Centaurreportwizardallowsyoutocreate yourownreportseasily. • CardUsage/CardCounteroptions (useacardupto255timesonadoor) • Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput) Visitor Management CentaurVisitorManagementwillallowyoutosecurelycontrolthecomingsandgoingsof allvisitors. Locator Monitorthelocation(inside/outside)ofeachcard holderinreal-time.View/Printreportswithaclickof abutton.Obtaindetailedcardholderinformation withadouble-clickofthemousebutton.Excellent formuster-pointapplications. manufacturing access Control since 1985 Live Interactive Floor Plans • Createorimportupto512floorplans • Fulllibraryoficons(orcreateyourown) • Event-basedtrigger-actions INTEGRATED ACCESS CONTROL E lECtroMagNEtiC l oCk or - Power Supply ! - Also includes an output of 16 VAC (75 VA) that can power up to 3 2-door expansion modules CA-A470-A + ISO - Thin card for printing - + 2 batteries (12V, 7AH) connected in series for 24V backup Connect earth terminal to a certified earth ground CS - Standard clamshell card Fire alarm contact for Lock1 & Lock2 Connect directly to controller lock terminals + + Lock Control Module (optional) CA-A110-P C oNtrollEr i Nputs + - (u p to 16 pEr CoNtrollEr ) Request-to-Exit Button (EXIT-BLP) Z1: 1K Ohm Z2: 2.2K Ohm EOL 1K Ohm To next controller of a site. GREEN GND BLACK R1/D1 12V OUT1 WHITE RED YELLOW (green LED) OUT2 OUT5 ORANGE (red LED) BROWN (buzzer) R2/DO DO GND - R2/D1 12V OUT3 D1 Polycarbonate Proximity reader dglP Fn WlC26 dgl OUT4 OUT6 R (red LED) B (buzzer) + V (green LED) H (Clock) Not applicable with Centaur System C oNtrollEr N Etwork (rs-485) R1/DO Blue (Clock) Not applicable with Centaur System a larM s ouNdEr Always consult the regulatory agency in your area for existing regulations regarding doors designated as emergency exits. Magnetic Door Contact + - + - Power Supply + Transformater CDVI150 24 Vac, 75VA 2-d oor C oNtrollEr Ct-V900-a d oor s trikE o ptioN + - stainless steel Proximity reader dgli WlC26 A2+ B2A1+ GND B1- GND module netWork (e-bus rs-485) Furthest module can be installed up to 1220M (4000ft) away from the CT-V900-A controller GND GND Optional Loop Supervision ! Reader wiring may differ from diagram. Please consult your documentation for details. Tamper Switch N.C. Contact eQuiPment Wire tyPe siZe max. length Card reader (1 LED or 1 LED & Buzzer) and Wiegand keypad 6 conductors, stranded, shielded (foil), drain conductor, Belden: 5304FE 18AWG 150m (500ft.) Card reader (2 LEDs & Buzzer) 8 conductors, stranded, shielded (foil), drain conductor, Belden: 5306FE 18AWG 150m (500ft.) Zone input 4 conductors, copper (JKT) 22AWG 600m (2000ft.) Door strike & AC transformer for controller 2 conductors, solid copper 18AWG 150m (500ft.), AC transformer: 8m (25ft.) RS-485 bus Ethernet CAT 5 , 4 pairs 24AWG 1220m (4000ft.) e cdvi.ca e-bus exPansion module CaPaCity 2-Door Expansion Module (CA-A470-A) 3 Relay Expansion Module (CA-A460-P) 2 Elevator Controller (CA-A480-A) 8 LCD Keypad (CK-TRAK-L) 8 cdvi.ca
© Copyright 2026 Paperzz